Development of the EGS4 Control Code to Calculate the Dose Distributions in a Strong Magnetic Field (자기장이 인가된 물팬텀 속의 전자선 선량분포 계산을 위한 EGS4 제어코드의 개발과 응용)

  • 정동혁;오영기;신교철;김진기;김기환;김정기;이강규;문성록;김성규
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • In this work we developed a EGS4 control code to calculate the dose distributions for high energy electron beams in water phantom applied longitudinal magnetic field. We reviewed the electron's motion in magnetic field and delivered equations for direction changs of the electron by the external magnetic field. The mathematical results are inserted into the EGS4 code system to account for the presence of external magnetic fields in phantom. The electron pencil beam paths of 6 MeV in water phantom are calculated for magnetic fields of 1-3 T and the dose distributions for a field of 1.0 cm in diameter are calculated for magnetic fields of 0.6-1 T using the code. From the results of path calculations we found that the lateral ranges of the electrons are reduced in the magnetic field of 3 T. For a field of 1 cm diameter and a magnetic field of 1 T, the small dose enhancement near the range of the electrons on the depth dose and the penumbra reduction of 0.15 cm on the beam profile are observed. We discussed and evaluated the results from the theoretical concepts.

  • PDF

A Study on Reducing of Entrance Surface Dose with the Eye in the Computed Radiography by Using High Kilo Voltage Peak Technique (컴퓨터 방사선영상에서 고 관전압 기법을 이용한 안구 입사표면선량 감소에 관한 연구)

  • Seoung, Youl-Hun;Rhim, Jea-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to minimize of entrance surface dose (ESD) at the eye using high kVp technique in the computed radiography. We used REX-650R (Listem, Korea) general X-ray unit, and external detector with ESD dosimeter of Piranha 657 (RTI Electronics, Sweden). We used head of the whole body phantom. The total 64 images of X-ray anterior-posterior of skull were acquired using the film/screen (F/S) method and the digital of computed radiography method. The three radiology professor of more 10 years of clinical career evaluated a X-rays images in the same space by 5-point scale. The external detector was performed measurement of ESD of three times by same condition on the eye of the head phantom. The good image quality in the F/S method (90 kVp, 2.5 mAs) showed at the minimized ESD of 0.310 ${\pm}$ 0.001 mGy. the good image quality in the computed radiography method (90 kVp, 2.0 mAs) showed at the minimized ESD of 0.180 ${\pm}$ 0.002 mGy (P = 0.002). Finally the radiation dose could reduced about 50% in the computed radiography method more than the F/S method. In addition the eye entrance surface dose using high kVp technique with the computed radiography was reduced 92% more than conventional technique (F/S method).

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.

Evaluation of Embryotoxic Potential of Olaquindox and Vitamin A in Micromass Culture and in Rats

  • Kang, Hwan-Goo;Ku, Hyun-Ok;Jeong, Sang-Hee;Cho, Joon-Hyoung;Son, Seong-Wan
    • Toxicological Research
    • /
    • v.26 no.3
    • /
    • pp.209-216
    • /
    • 2010
  • Limb bud (LB) and central nerve system (CNS) cells were prepared from 12.5 day old pregnant female Crj:CD (SD) rats and treated with olaquindox and vitamin A. Cytotoxicity and inhibition on differentiation were measured in each cell. Three doses of olaquindox (4, 21 and 100 mgkg), and 0.2 and 75 mg/kg of vitamin A were administered to pregnant rat for 11 days from $6^{th}$ to $16^{th}$ of pregnancy. $IC_{50}$ values of olaquindox for proliferation and differentiation in CNS cell were 22.74 and $28.32\;{\mu}g/ml$ and 79.34 and $23.29\;{\mu}g/ml$ in LB cell and those values of vitamin A were 8.13 and $5.94\;{\mu}g/ml$ in CNS cell and 0.81 and $0.05\;{\mu}g/ml$ in LB cell, respectively. Mean body weights of pregnant rats were decreased at high dose of olaquindox (110 mg/kg) but relative ovary weight, number of corpus lutea, and number of implantation were not changed. Resorption and dead fetus were increased at high dose of olaquindox, and relative ovary weight, the number of corpus lutea and implantation, and sex ratio of male to female were not significantly changed in all dose of olaquindox. Mean fetal and placenta weights were significantly (p < 0.01) decreased in rats of high group. Seven fetuses out of 103 showed external anomaly like bent tail, and 10 out of 114 fetuses showed visceral anomalies at high group. The ossification of sternebrae and metacarpals were significantly (p < 0.01) increased by low and middle dose of olaquindox but it was significantly (p < 0.01) prohibited by high dose of olaquindox. In rats treated with vitamin A, the resorption and dead fetus were increased by high dose. Mean fetal weights were significantly (p < 0.01) increased by low dose but significantly (p < 0.01) decreased by high dose. Thirty four fetuses out of 52 showed external anomaly; bent tail (1), cranioarchschisis (14), exencephaly (14), dome shaped head (22), anophthalmia (15), brcahynathia (10) and others (19). Forty five fetuses out of 52 showed soft tissue anomaly; cleft palate (42/52) and anophthalmia (22/52) by high dose of vitamin A. Sixty one fetuses out of 61 (85.2%) showed skull anomaly; defect of frontal, partial and occipital bone (21/61), defect of palatine bone (52/61) and others (50/61). In summary, we support that vitamin A is strong teratogen based on our micromass and in vivo data, and olaquindox has a weak teratogenic potential in LB cell but not in CNS cell. We provide the in vivo evidence that a high dose of olaquindox could have weak embryotoxic potential in rats.

The Effect of External Radiation Therapy in Management of Malignant Obstructive Jaundice due to Porta Hepatis Metastasis from Stomach Cancer (위암의 간문맥 전이로 발생한 악성 폐쇄성 황달에 대한 외부 방사선치료 효과)

  • Yang, Kwang-Mo;Kim, Joon-Hee;Kim, Chul-Soo;Suh, Hyun-Suk;Kim, Re-Hwe
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.339-348
    • /
    • 1995
  • Purpose : Since 1983, authors have conducted a study to evaluate the effect of external radiation therapy and to determine affected factors in management of the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. Materials and Methods : Thirty two patients with malignant obstructive jaundice due to porta hepatis metastasis from gastric cancer were presented. We have analysed 23 patients who were treated with external radiation therapy of more than 3000cGy. The radiation dose, disease extent at developement of jaundice, total bilirubin levels before radiation therapy, differentiation of histology, combind treatment, intent of primary surgery, initial stage of gastric cancer were analyzed to determine affected factors in radiation therapy. External radiation therapy was delivered with a daily dose of 180-300cGy, 5 times a week fractionation using 4 MeV linear accelerator. The radiation field included the porta hepatis with tumor mass by the abdominal ultrasonography or CT scan. In twenty three patients received more than 3000cGy, total irradiation dose was ranged from 3000cGy to 5480cGy, median 3770cGy. Among 23 patients, 13 patients were delivered more than equivalant dose of TDF 65(4140cGy/23fx). Results : Among 23 patients, complete, partial and no response were observed in 13, 5, 5 patients, respectively. The median survival for all patients was 5 momths. The significant prolongation of median survival was observed in complete responders(11 months) as compared to partial and no responders(5 months, 5 months respectively) Out of 13 patients with complete response, 6 patients lived more than a year Among 13 patients receiving more than 4140cGy equivalent dose, complete, partial and no response were observed in 10, 2 and 1 patients, respectively. The median survival for all these patients was 9.5 months. The median survival for complete responders(10/13) was 11.5 months. Among 10 patients receiving less than 4140cGy equivalent dose, complete, partial and no response were observed in 3, 3, 4 patients, respetively. The median survival for all these patients was 4.3 months Therefore, the radiation dose affected the results of treatment. For the complete response with prolongation of survival duration, at least 4140cGy equivalant dose should be delivered to porta hepatis. In evaluation of the disease extent, 7 patients of 13 complete responders showed localized disease in porta hepatis or peripancreatic area, but all patients with partial and no response showed wide extensive disease or persistant disease of primary gastric cancer. Therefore. the patients with the localized disease were the higher probability of complete response and long term survival. This study suggested that the radiation dose and the disease extent at developement of jaundice affected in radiation therapy for malignant obstructive jaundice. There were no serious complications related to external radiation therapy. Conclusion : External radiation therapy only could achieve the palliative effect in the patients with malignant obstructive jaundice due to porta hepatis metastasis from stomach cancer. This study suggested that the prolongation of survival duration could be achived in complete responders and radiation dose, extent of disease affected the results of treatment of malignant obstructive jaundice.

  • PDF

Brachytherapy for Head and Neck Cancer (두경부암의 근접방사선 치료)

  • Yoo Seong-Yul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.7 no.1
    • /
    • pp.3-9
    • /
    • 1991
  • Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. The main characteristics of brachytherapy are delivering of higher dose to target volume shortening of total treatment period and sparing of normal tissue. Recent development of iridium ribbons for low dose rate implant provides improvement of technology of brachytherapy in terms of safety and efficiency. High dose rate method. on the other hand, is effective to avoid unnecessary expoure of medical personnel.

  • PDF

Prenatal Deaths and External Malformations Caused by X-Irradiation during the Preimplantation Period of ddy Mice (임신 ddy Mice에서 착상전기 방사선 조사에 따른 산전 사망 및 외부 기형 발현)

  • Ro, Hee-Jeong;Choi, Ihl-Bhong;Gu, Yeun-Wh
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.233-243
    • /
    • 1998
  • Purpose : To evaluate the effects of X-irradiation on prenatal deaths, i.e., preimplantation deaths, embryonic deaths and fetal deaths, and on external malformations in precompacted preimplantation ddy mice Materials and Methods : Pregnant mice (n=85) obtained by limiting the mating time to from 6 to 9 A.M., were segregated into 11 groups. The first five groups (n=26) were irradiated with X-ray doses of 0.1 0.5, 0.75, 1.5, and 3 Gy, respectively, at 24 h post conception (p.c.) of the preimplantation Period. The second five (n=27) groups were irradiated at the same X-ray doses, respectively, but at 48 h p.c. of the preimplantation period. The last group (n=32) was the control group. The uterine contents were examined on the 18th day of gestation for prenatal deaths and external malformations. Results : 1) A statistically significant increase in preimplantation deaths with increasing dose was observed in the experimental groups irradiated at 24 h p.c. and in the groups irradiated at 48 h p.c., as compared to the control group. The threshold dose was close to 0.05 Gy and 0.075 Gy for the irradiations at 24 h p.c. and 48 h p.c. respectively. 2) A statistically significant increase in embryonic deaths with increasing dose was observed in all irradiation groups, except the group irradiated with a dose of 0.1 Gy at 48 h p.c.. 3) No fetal deaths were found in any experimental group. 4) In the experimental groups irradiated at 24 h p.c. anomalies increased with statistical significance, as compared with the control group : 2 exencephalies, 2 open eyelids, 3 anophthalmias, 2 cleft Palates, 2 gastroschisis, 1 abdominal wall defect. 1 leg defect, and 2 short tail anomalies: the threshold dose for external malformations was close to 0.2 Gy at 24 h p.c.. In the groups irradiated at 48 h p.c., 1 open eyelid and 2 short tail anomalies were observed, but there was no statistical significance in those malformations. Conclusion : The results of this study reveal that X-irradiation of precompacted preimplantation ddy mice causes not only preimplantation deaths and embryonic deaths but also external malformations. In addition, external malformations were observed in our experiments at diagnostic doses, including 0.1 and 0.5 Gy. For this reason, we recommend that irradiation should be avoided during the preimplantation period by applying Rugh's 10-day rule.

  • PDF

External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities (고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사)

  • Choi, Chang-Heon;Kim, Jung-In;Park, Jong-Min;Park, Yang-Kyun;Cho, Kun-Woo;Cho, Woon-Kap;Lim, Chun-Il;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Purpose: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. Materials and Methods: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party’s American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Results: Most of the beams (74%) were within ${\pm}2%$ of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (${\pm}3%$), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be ${\pm}1.5%$. Conclusion: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

The moderating effects of organizational culture on the relationship among open information innovation, strategic alliance and export performance of SMEs (중소 수출기업의 개방형 정보 혁신, 전략적 제휴, 수출성과의 관계에서 조직문화의 조절효과)

  • Cho, Yeon-Sung;Khoe, Kyung-Il
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.2
    • /
    • pp.219-225
    • /
    • 2018
  • The objectives of this study is to analyze the impact of open information innovation which consisted of external technology acquisition and external technology exploitation on export performance by integrating with strategic alliance factors. This study empirically analyzed six hypotheses in 201 sample using the PLS (Partial Least Square) of the structural equation model to verify the moderating effects of organizational culture on the relationship among open information innovation, strategic alliance and export performance. As a result, external technology acquisition dose not affect strategic alliances. On the other hand, external technology exploitation has a positive impact on strategic alliances. Strategic alliances also have a positive impact on export performance. As a result of the moderating effect analysis, the interaction between organizational culture and external technology acquisition has positively influenced strategic alliances. In addition, the moderating effect of organizational culture and external technology exploitation has a significant effect on strategic alliances. However, moderating effect of organizational culture and strategic alliance dose not affect export performance. This study has a contribution to the analysis of the moderating effects of organizational culture. In the future, integrated analysis of open information innovation and external factors is needed.

National trends in radiation dose escalation for glioblastoma

  • Wegner, Rodney E.;Abel, Stephen;Horne, Zachary D.;Hasan, Shaakir;Verma, Vivek;Ranjan, Tulika;Williamson, Richard W.;Karlovits, Stephen M.
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.13-21
    • /
    • 2019
  • Purpose: Glioblastoma (GBM) carries a high propensity for in-field failure despite trimodality management. Past studies have failed to show outcome improvements with dose-escalation. Herein, we examined trends and outcomes associated with dose-escalation for GBM. Materials and Methods: The National Cancer Database was queried for GBM patients who underwent surgical resection and external-beam radiation with chemotherapy. Patients were excluded if doses were less than 59.4 Gy; dose-escalation referred to doses ≥66 Gy. Odds ratios identified predictors of dose-escalation. Univariable and multivariable Cox regressions determined potential predictors of overall survival (OS). Propensity-adjusted multivariable analysis better accounted for indication biases. Results: Of 33,991 patients, 1,223 patients received dose-escalation. Median dose in the escalation group was 70 Gy (range, 66 to 89.4 Gy). The use of dose-escalation decreased from 8% in 2004 to 2% in 2014. Predictors of escalated dose were African American race, lower comorbidity score, treatment at community centers, decreased income, and more remote treatment year. Median OS was 16.2 months and 15.8 months for the standard and dose-escalated cohorts, respectively (p = 0.35). On multivariable analysis, age >60 years, higher comorbidity score, treatment at community centers, decreased education, lower income, government insurance, Caucasian race, male gender, and more remote year of treatment predicted for worse OS. On propensity-adjusted multivariable analysis, age >60 years, distance from center >12 miles, decreased education, government insurance, and male gender predicted for worse outcome. Conclusion: Dose-escalated radiotherapy for GBM has decreased over time across the United States, in concordance with guidelines and the available evidence. Similarly, this large study did not discern survival improvements with dose-escalation.