• Title/Summary/Keyword: External AC magnetic field

Search Result 44, Processing Time 0.033 seconds

Crystal growth from melt in combined heater-magnet modules

  • Rudolph, P.;Czupalla, M.;Dropka, N.;Frank-Rotsch, Ch.;KieBling, F.M.;Klein, O.;Lux, B.;Miller, W.;Rehse, U.;Root, O.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.5
    • /
    • pp.215-222
    • /
    • 2009
  • Many concepts of external magnetic field applications in crystal growth processes have been developed to control melt convection, impurity content and growing interface shape. Especially, travelling magnetic fields (TMF) are of certain advantages. However, strong shielding effects appear when the TMF coils are placed outside the growth vessel. To achieve a solution of industrial relevance within the framework of the $KRISTMAG^{(R)}$ project inner heater-magnet modules(HMM) for simultaneous generation of temperature and magnetic field have been developed. At the same time, as the temperature is controlled as usual, e.g. by DC, the characteristics of the magnetic field can be adjusted via frequency, phase shift of the alternating current (AC) and by changing the amplitude via the AC/DC ratio. Global modelling and dummy measurements were used to optimize and validate the HMM configuration and process parameters. GaAs and Ge single crystals with improved parameters were grown in HMM-equipped industrial liquid encapsulated Czochralski (LEC) puller and commercial vertical gradient freeze (VGF) furnace, respectively. The vapour pressure controlled Czochralski (VCz) variant without boric oxide encapsulation was used to study the movement of floating particles by the TMF-driven vortices.

AC susceptibility of current-carrying iron whiskers : Effect of current variation (전류에 의한 철단결정의 교류 자기감수율 : 전류 변화에 의한 효과 )

  • Jae-Gwang Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.179-184
    • /
    • 1995
  • The ac magnetic susceptibility of {100} iron whiskers as a function of currents is studied with and without external field. The ac susceptibility depends on the magnitude and the direction of the applied dc current when a small external field is applied along the magnetization of the central domain of the whisker. Variation of the central domain size accounts for the current-dependent response. The measured magnetic responses are explained, using a micromagnetic calculation based on a simple model, as a function of applied currents over a wide range except critical values.

  • PDF

Thermo-sensitive Electrospun Fibrous Magnetic Composite Sheets

  • Choi, Jungsu;Kim, Jinu;Yang, Heejae;Ko, Frank K.;Kim, Ki Hyeon
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.215-220
    • /
    • 2015
  • The PVDF fibrous composite filled with iron oxide nanoparticles were prepared by using the electrospinning technique. The electrospun composite have the thickness in the range of $60-80{\mu}m$ with the average fibrous diameters of 500-900 nm. The magnetizations of PVDF fibrous composite filled with iron oxide nanoparticles showed 4.5 emu/g, 3.1 emu/g and 1.6 emu/g at 1.5 T of external magnetic field for 20 wt.%, 10 wt.% and 5 wt.% iron oxide nanoparticles, respectively. The heat elevation of the magnetic composite were measured under various AC magnetic fields, frequency and the ambient temperatures. The temperature reached up to $46.3^{\circ}C$ from $36^{\circ}C$ at 128 Oe and 355 kHz for 20 wt.% iron oxide nanoparticles filled in PVDF fibrous composite sheet. The specific absorption rate of theses sheets increased from 0.041 W/g to 0.236 W/g with the increment of AC magnetic field from 90 Oe to 167 Oe at 190 kHz, respectively.

Test result of striated HTS compact cables for low AC loss

  • Kim, Y.;Kim, W.S.;Lee, J.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.44-47
    • /
    • 2013
  • Large AC loss from the second generation (2G) high temperature superconducting (HTS) wires has been one of the major bottlenecks in power applications with HTS materials. Moreover, the large power applications also require the large current capacity from the HTS wires, which makes them produce larger AC losses. In order to reduce the AC loss from the HTS conductors with large current capacity, an HTS compact cable with some striations on the superconducting layers has been proposed. In this paper, we prepared some sample HTS compact conductors with striations, and measured their magnetization loss from the external magnetic field. We also made some slits on the superconducting layer of the HTS wire by laser cutting to reduce the aspect ratio of the superconducting layers. It would make the low eddy current loss and magnetic decoupling. Finally, the magnetization losses of the sample HTS compact conductors were measured and analyzed.

Experimental and numerical approaches for AC loss estimation in high $T_{c}$ superconductors

  • Amemiya, Naoyuki
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.1-6
    • /
    • 2004
  • It is important to estimate the total AC loss which is the total energy, or power, dissipated in the superconductor in the simultaneous application of AC transport current and an AC external magnetic field. Experimental and numerical works on AC loss estimation of high $T_c$ superconductors in the author's group are reviewed. The method and the set-up for total AC loss measurements are described. The experimental results for a twisted Bi-2223 multifilamentary tape and a Y-123 mm conductor are given. A general theory for numerical electromagnetic field analysis of superconductor by the finite element method is explained. The numerical results for twisted Bi-2223 multifilamentary tapes and a rectangular superconductor simulating coated conductors are presented.

RELATIONSHIP BETWEEN STATIC AND DYNAMIC MAGNETORESISTANCE BEHAVIOR OF METALLIC ARTIFICIAL SUPERLATTICES

  • Song, Yong-Jin;Joo, Seung-Ki
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.567-569
    • /
    • 1995
  • By using the ac field source which can change the applied field magnitude, frequency and dc offset field, the dynamic magnetoresistance characteristics of permalloy based multilayers which have different R-H(resistance-magnetic field) curves were monitored and compared with static magnetoresistance curves that were measured with electromagnet of VSM. Output of each sample according to the external field strength was identified and optimum bias position could be obtained.

  • PDF

Fiber-optic Mach-Zehnder Interferometer for the Detection of Small AC Magnetic Field (미소 교류 자기장 측정을 위한 Mach-Zehnder 광섬유 간섭계 자기센서 특성분석)

  • 김대연;안준태;공홍진;김병윤
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.139-148
    • /
    • 1991
  • A fiber-optic magnetic sensor system for the detection of small ac magnetic field(200Hz-2 kHz) was constructed. Magnetic field sensing part was fabricated by bonding a section of optical fiber to amorphous metallic glass(2605SC) having large magnetostriction effect. And with the directional coupler, all fiber type Mach-Zehnder interferometer was constructed to measure the variation of the external magnetic field by translating it into the optical phase shift in the interferometer. The signal fading problem of the interferometer, which is due to random phase drifts originated from the environment, i.e., temperature fluctuation, vibrations, etc., was elliminated by feedback phase compensation. This allows the sensitivity to be maintained at the maximum by keeping the interferometer in quadrature phase condition. The frequency response of metallic glass was found to be nearly flat in the range of 90 Hz-2 kHz and dc bias field for the maximum ac response was 3.5 Oe. The interferometer output showed good linearity over the range $\pm$0.5 Oe. For 1 kHz ac magnetic field the scale factor S and the minimum detectable magnetic field were measured to be 8.0 rad/Oe and $3X10^{-6} Oe/\sqrt{Hz}$at 1 Hz detection bandwidth respectively.

  • PDF

Numerical Analysis of The Coupling Loss in AC Superconducting Wires (교류용 초전도선의 결합손실해석)

  • Sim, Jung-Wook;Cha, Guee-Soo;Lee, Ji-Kwang;Choi, Kyeong-Dal;Han, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.291-293
    • /
    • 1997
  • The external magnetic field which is applied to the superconducting wire generates coupling loss. Analytical method has been used for the calculation of the coupling loss. This paper calculates the coupling loss that is generated in the matrix by the external magnetic field. Two-dimensional Finite Element Method has been used for the calculation.

  • PDF

AC loss analysis and experimental evaluation of a high temperature superconductor (고온초전도선재의 교류손실 해석 및 실험)

  • Ryu, Kyung-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.96-100
    • /
    • 2001
  • Bi-2223 tapes have been developed for low-field power applications at liquid nitrogen temperature. When the Bi-2223 tapes are used in an application such as a power transmission cable or a power transformer, they are supplied with an AC transport current and exposed to an external magnetic field generated by neighboring tape's AC currents simultaneously. AC loss taking into account such real applications is a crucial issue for power applications of the Bi-2223 tapes to be feasible. In this paper, the transport losses for different AC current levels and arrangements of the neighboring tapes have been measured in a 1.5 m long Bi-2223 tape. The significant increase of the transport losses due to neighboring tape's AC currents is observed. An increase of the transport losses caused by a decrease of the Bi-2223 tape's critical current is a minor effect. The measured transport losses could not be explained by a dynamic resistance loss based on DC voltage-current characteristics in combination with the neighboring tape's AC currents. The transport losses do not depend on the frequency of the neighboring tape's AC currents but its arrangements in the range of small current especially.

  • PDF

Magnetization Losses in YBCO Coated Conductors According to Angles of External Magnet Field (외부자장인가 방향에 따른 YBCO CC의 자화 손실 특성)

  • Lim, Hyoung-Woo;Lee, Sang-Su;Lee, Hee-Joon;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1222-1224
    • /
    • 2005
  • AC loss is an important factor in the development of superconducting tapes and superconducting power applications. In this paper, magnetization loss in YBCO coated conductor have been measured and compared with Brandt equation. Measurements of magnetization loss were performed under various angles of external magnetic field to consider the anisotropic characteristics of YBCO coated conductors. The results show that measured values of magnetization loss agreed well with the calculated value by using Brandt equation, especially at large degrees of incidence angle. The magnetization losses were strongly influenced by the direction of external magnet field as were expected.

  • PDF