• Title/Summary/Keyword: Exterior Noise

Search Result 102, Processing Time 0.022 seconds

Active Control of External Noise Radiated From Duct Using Sound Intensity (음향 인텐시티를 이용한 관 외부 방사 소음의 능동 제어)

  • 강성우;김양한
    • Journal of KSNVE
    • /
    • v.7 no.3
    • /
    • pp.427-437
    • /
    • 1997
  • Mean active intensity based active control for the cancellation of radiated noise out of the duct exit is studied. The active intensity control strategy is drerived based on the relation of the exterior sound field out of the duct termination and interior sound field of the duct. One of the characteristics of this control strategy is that the control performance can be maintained regardless of the sensor loction, compared with the conventional local pressure control methods at either interior downstream or exterior field positions. It is also suggested that the digital filtering for the active intensity control can be achieved by time-domain filtered-x LMP (Lest-Mean-Product) adaptive algorithm. Experiments for an open-ended duct are performed to compare the active intensity control performance with conventional pressure control one. Active control experiment of local sound pressure is conducted by widely used filtered-x LMS adaptive Algorithm and active intensity control implementaion uses the derived filter d-x LMP algorithm. It is shown that the exterior sound fileds was much better observable by sensing of the active intensity than by just sound pressure. It is also demonstrated that the global control performance of external field by acoustic intensity is superior to the conventional sound pressure control performance.

  • PDF

A study on the Application of Inorganic Reinforced Non-Flammable Molding to Building Exterior (무기계보강 CLC 불연몰딩의 건축물 외벽적용 연구)

  • Kwon, Hae-Won;Gong, Min-Ho;Lee, Chang-Woo;Choi, Byung-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.61-62
    • /
    • 2021
  • Exterior wall molding, which is widely applied as a design element of the exterior wall of domestic apartment, should be applied as a nonflammable or semi-nonflammable material grade according to the rules on standards for evacuation/fire protection structures of buildings. For this reason, stone and AL sheet are mainly used, but stone is expensive and design autonomy is low. Inorganic reinforced CLC nonflammable molding was applied to the exterior wall of the building through tests of nonflammable performance, noise reduction, and installation stability.

  • PDF

The Effect of Road Distribution Around the School Buildings on the Status of Study on the Effect of Noise (주변도로 분포가 학교건축물의 소음실태에 미치는 영향에 관한 연구)

  • Kim, Tae-Woo;Lee, Kang-Guk;Hong, Won-Hwa
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.4
    • /
    • pp.3-12
    • /
    • 2011
  • This study investigates interior and exterior environments and arrangement forms of school buildings from elementary to high school which were recently built in Daegu since the 7th Educational Curriculum. In addition, this study analyses how outside noise affects inside environment of schools. This study found that the noise level criteria of school facilities(such as exterior learning sites and outer walls of school buildings) adjacent to street of one side satisfiedly corresponded to the level and criteria, 65dB(A), of school health law. However, the noise level and vibration criteria of school facilities adjacent to street of two sides did not satisfiedly corresponded to the level or criteria, 65dB(A). In case of classrooms, the inner noise of educational facilities with windows closed and also close to both the street of one side and of two sides satisfiedly corresponded to the level or criteria. 55dB(A), of school health law. In spring and tall, the windows are more open them usual for ventilation, and leaving windows open can lead to noise from outside. Thus, it is urgent to prepare for this situation.

  • PDF

Predicting Noise inside a Trimmed Cavity Due to Exterior Flow (외부 유동에 의한 흡차음재 공간내의 소음 예측)

  • Jeong, ChanHee;Ganty, Bastien;Choi, EuiSung;Cho, MunHwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.466-471
    • /
    • 2014
  • The interior vehicle noise due to the exterior aerodynamic field is an important topic in the acoustic design of a car. The air flow detached from the A-pillar and impacting the side windows are of particular interest as they are located close to the driver / passenger and provides a lower insulation index than the trimmed car body parts. This paper presents a numerical analysis method for a simplified vehicle model. The internal air cavity including trim component are included in the simulation. The car body includes the windshield and two side windows. The body is made of aluminum and trimmed with porous layers. The methodology proposed in this paper relies on two steps: the first step involves the computation of the exterior flow and turbulence induced non-linear acoustic field using PowerFlow. The second step consists in the computation of the vibro-acoustic transmission through the window using the finite element vibro-acoustic solver Actran. Additionally in order to validate the numerical process, an experimental set-up has been created based on the simplified vehicle. The vibration of the windshield and windows, the total wind noise level results and the relative contributions of the different windows are then presented and compared to measurements. The influence of the flow yaw angle (different wind orientation) is also assessed.

  • PDF

Active Window to Reduce the Exterior Noise Flowed Through the Open Window (열린 창문을 통해 유입되는 소음을 저감하는 능동소음제어 창문)

  • Kwon, Byoung-Ho;Park, Young-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.820-827
    • /
    • 2011
  • Recently, noise has been regarded as one of the most notorious and frequent environmental pollutions which can be often encountered not only in the living space but also in the industrial site. Studies on physiological and psychological effects of long-term noise exposure to human being have commanded the public interest on noise issues. Since environmental noises such as traffic noise and construction noise is mainly flowed through the open window, it is necessary to develop the active noise control system to reduce it inside the building. Although control speakers and microphones for the noise signal measurement in the control region are essential for the conventional active noise control methods, it is impossible to implement them in the control region in the building environment because the control region is the living quarter and they may hinder activities of the residents. Therefore, we proposed the active window system to reduce the exterior noise flowed through the open window with microphones installed outside the window and control speakers installed at the frame of the window. To confirm the performance of the proposed active window, we carried out the simulation and experiment using active window system with 8 control speakers. Simulation results showed the noticeable noise reduction effect inside the control region within the frequency range without the spatial aliasing. Experimental result showed that the total acoustic potential energy inside the room of the scale model is reduced to about 10dB within the interest of frequency range.

Airborne Sound Insulation Performance of Window and Indoor Noise Level in the Balcony Expanded Apartments

  • Park, Hyeon Ku
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.61-67
    • /
    • 2015
  • Purpose: The balcony in the apartment is important space not only as a fire escape but also as a buffer for heat and sound insulation. However, with the legalization of balcony expansion for residential apartments in Korea in 2006, many households have eliminated the balcony space altogether to increase the inner space, often without sufficient consideration for the effects on the indoor environment. This study examined the sound insulation performance of exterior-facing windows in enclosed balconies and the changes in the indoor acoustic environment due to expansion to provide a basis for appropriate balcony expansion. The apartments for the field test were chosen where two balcony types can be compared, and the sound insulation performance for the eighteen balcony windows was measured. The windows installed were typical double window with thickness 16 mm or 22 mm. Measurements of the weighted standard sound pressure level difference showed a decrease of about 3 dB in sound insulation performance due to expansion. For common exterior noise levels of 70-85 dB(A), the indoor noise level can exceed 45 dB(A), the limit level regulated in Korea. However, it was found that the sound insulation performance of the window and the quality of the construction have more influence on indoor noise levels than balcony expansion itself.