• 제목/요약/키워드: Extensor indicis proprius

검색결과 5건 처리시간 0.017초

수배부의 신전건에 대한 해부학적 연구 (An Anatomic Study of the Extensor Tendons of the Human Hand)

  • 강문석;정성균;남승민;신호성;김용배
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.836-844
    • /
    • 2011
  • Purpose: Hands are the chief organs for physically manipulating the environment, using anywhere from the roughest motor skills to the finest, and since the fingertips contain some of the densest areas of nerve endings on the human body, they are continuously used organ with complex functions, and therefore, often gets injured. To prevent any functional loss, a detailed anatomical knowledge is required to have a perfect surgical treatment. Also it is necessary to have a thorough understanding of arrangements of the human extensor tendons and intertendinous connections when tenoplasty or tendon transfer is required. We performed a study of the arrangements of the human extensor tendons and the configuration of the intertendinous connections over the dorsum of the wrist and hand. Methods: A total of 58 hands from Korean cadavers were dissected. The arrangements of extensor indicis proprius, extensor digitorum communis, and extensor digiti minimi tendons and intertendinous connections were studied. Results: The most common distribution patterns of the extensor tendons of the fingers were as follows: a single extensor indicis proprius (EIP) tendon which inserted ulnar to the extensor digitorum-index (EDC-index); a single EDC-index; a single EDC-middle; a double EDC-ring; an absent EDC-little; a double extensor digiti minimi (EDM), a single EDC-index (98.3%), a single EDC-middle (62%), a double EDC-ring (50%), and an absent (65.5%) or a single (32.8%) EDC-little. A double (70.6%) EDM tendons were seen. Intertendinous connections were classified into 3 types: type 1 with thin filamentous type, type 2 with a thick filamentous type, and type 3 with a tendinous type subdivided to r shaped 3r type and y shaped 3y type. The most common patterns were type 1 in the 2nd intermetacarpal space, type 2 in the 3rd intermetacarpal space, and type 3r in the 4th intermetacarpal space. And in the present study, we observed one case of the extensor digitorum brevis manus (EDBM) on the boht side. Conclusion: A knowledge of both the usual and possible variations of the extensor tendon and the intertendinous connection is useful in the identification and repair of these structures.

Closed extensor tendon rupture caused by Kienbock disease: a case report

  • Choi, Jong Yun;Cha, Won Jin;Jung, Ee Room;Seo, Bommie F.;Jung, Sung-No
    • Archives of Plastic Surgery
    • /
    • 제49권1호
    • /
    • pp.76-79
    • /
    • 2022
  • Kienböck disease, a rare disease that can cause chronic pain and motor dysfunction, occurs due to avascular necrosis of the lunate bone, which leads to dislocation of the carpal bone. Among various other etiologies, Kienböck disease can cause closed tendon rupture of the finger. In this report, we introduce a case of total rupture of the second extensor digitorum communis and the extensor indicis proprius tendons caused by undiagnosed Kienböck disease in an elderly female patient.

Bilateral Digital Extensor Hypoplasia Correction: A Case Report and Systematic Review

  • Marudeen Aivaz;Esperanza Mantilla-Rivas;Ashleigh Brennan;John Thomas;Elizabeth L. Malphrus;Monica Manrique;Albert K. Oh;Gary F. Rogers
    • Archives of Plastic Surgery
    • /
    • 제50권2호
    • /
    • pp.177-181
    • /
    • 2023
  • Digital extensor hypoplasia (DEH) is a rare malformation that presents with loss of active finger extension at the metacarpophalangeal (MCP) joints. Descriptions of optimal treatment and outcomes in this population are sparse. We describe successful operative treatment of a child with DEH involving the extensor digitorum communis, extensor digiti minimi, and the extensor indicis proprius tendons. The 5-year-old male patient was referred for severe limitation on bilateral finger extension since birth. He had been previously diagnosed with arthrogryposis and managed conservatively. Due to lack of improvement, magnetic resonance imaging was done evidencing hypoplasia/aplasia of the extensor tendons. The patient underwent successful tendon transfers using extensor carpi radialis longus to the common extensor tendons, and one hand required an additional tenolysis procedure. 2 years postoperatively, his MCP position and finger extension are markedly improved, and he is able to grip objects without limitation or difficulty. The patient returned to full activity without restriction.

Reconstruction of Hand Dorsum Defect Using Double Perforators-Based Anterior Interosseous Artery Island Flap: A Case Report and Description of a New Anterior Interosseous Artery Perforator

  • Inho Kang;Hyun Rok Lee;Gyu Yong Jung;Joon Ho Lee
    • Archives of Plastic Surgery
    • /
    • 제50권4호
    • /
    • pp.409-414
    • /
    • 2023
  • The anterior interosseous artery (AIA) perforator flap is not commonly used in hand dorsum reconstruction compared with alternatives. However, it is a versatile flap with several advantages. Literature on the AIA perforator flap is based on the dorsal septocutaneous branch (DSB), which branches from the AIA and passes through fascia between the extensor pollicis longus (EPL) and extensor pollicis brevis muscles. In the described case, the authors reconstructed a hand dorsum defect in a 78-year-old man using an AIA perforator flap with double perforators supplied by the DSB and a new perforator branching from the distal than DSB. No complication was encountered, and the flap survived completely. A retrospective computed tomography review revealed the presence of the new perforator in 14 of 21 patients. Two types of new perforator were observed. One passed through the ulnar side of the extensor indicis proprius (EIP) muscle and penetrated fascia between the extensor digitorum minimi and extensor digitorum communis tendons, whereas the other passed between the EPL and EIP muscles. This report describes the anatomical location and clinical application of the new AIA perforators. The double perforators-based AIA flap provides a straightforward, reliable means of reconstructing hand dorsum defects.

대표근육 자극을 통한 EMS 기반 역감 제어방법론 제안 (EMS based Force Feedback Methodology through Major Muscle Group Activation)

  • 김효민;권재성;오용환;양우성
    • 로봇학회논문지
    • /
    • 제12권3호
    • /
    • pp.270-278
    • /
    • 2017
  • The electrical muscle stimulator (EMS) based human machine interface (HMI) free to mechanical constraint and muscle fatigue problems are proposed for force feedback in a virtual reality. The device was designed to provide force feedback up to 4.8 N and 2.6 N each to the thumb and forefingers. The main objective of the HMI is to make unnecessary mechanical structures to attach on the hand or fingers. It employs custom EMSs and an interface arranged in the forearm. In this work, major muscle groups such as extensor pollicis brevis (EPB), extensor indicis proprius (EIP), flexor pollicis longus (FPL) and flexor digitorum profundus (FDP) are selected for efficient force feedback and controlled individually. For this, a human muscular-skeletal analysis was performed and verified. The validity of the proposed multi-channel EMS based HMI was evaluated thorough various experiments with ten human subjects, interacting with a virtual environment.