• Title/Summary/Keyword: Extended head

Search Result 186, Processing Time 0.038 seconds

Analysis of dismantling process and disposal cost of waste RVCH

  • Younkyu Kim;Sunkyu Park ;TaeWon Seo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.45-51
    • /
    • 2023
  • During the operation of a nuclear power plant (NPP), the waste reactor vessel closure head (RVCH) that is replaced owing to design or manufacturing defects is buried in a designated area or temporarily stored in a radiation shielding facility within the NPP. In such cases, storing it for extended periods proves a challenge owing to space constraints in the power plant and a safety risk associated with radiation exposure; therefore, dismantling it quickly and safely is crucial. However, not much research has been done on the dismantling of the RVCH in an operational power plant. This study proposes a dismantling process based on the radioactive contamination level measured for the Kori #1 RVCH, which is currently being discarded and stored, and examines the decontamination and cutting according to this process. In addition, the amount of secondary waste and dismantling cost are evaluated, and the dismantling effect of the reactor closure head is analyzed.

Pre-cluster HEAD Selection Scheme based on Node Distance in Chain-Based Protocol (체인기반 프로토콜에서 노드의 거리에 따른 예비 헤드노드 선출 방법)

  • Kim, Hyun-Duk;Choi, Won-Ik
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1273-1287
    • /
    • 2009
  • PEGASIS, a chain-based protocol, forms chains from sensor nodes so that each node transmits and receives from a neighbor. In this way, only one node (known as a HEAD) is selected from that chain to transmit to the sink. Although PEGASIS is able to balance the workload among all of the nodes by selecting the HEAD node in turn, a considerable amount of energy may be wasted when nodes which are far away from sink node act as the HEAD. In this study, DERP (Distance-based Energy-efficient Routing Protocol) is proposed to address this problem. DERP is a chain-based protocol that improves the greedy-algorithm in PEGASIS by taking into account the distance from the HEAD to the sink node. The main idea of DERP is to adopt a pre-HEAD (P-HD) to distribute the energy load evenly among sensor nodes. In addition, to scale DERP to a large network, it can be extended to a multi-hop clustering protocol by selecting a "relay node" according to the distance between the P-HD and SINK. Analysis and simulation studies of DERP show that it consumes up to 80% less energy, and has less of a transmission delay compared to PEGASIS.

  • PDF

Extended Technology Acceptance Model of VR Head-Mounted Display in Early Stage of Diffusion (기술수용모델을 이용한 초기이용자들의 가상현실기기 채택 행동 연구)

  • Jang, Han-Jin;Noh, Ghee-Young
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.353-361
    • /
    • 2017
  • As one of Virtual Reality devices, HMD(Head-Mounted Device) helps users to experience an extended actual environment by providing them with virtual environment flexibly through the device. HMD considers user experience as importance as well as technical factors. Therefore, this study intended to analyze how the factors such as information quality, enjoyment, self-efficacy can have influence on the adoption of VR device using the extended technology acceptance model. The results showed that information quality and enjoyment have significant influences on perceived ease of use and usefulness. Self-efficacy only affect perceived ease of use. In addition, perceived ease of use and usefulness have influences on intention to use.

Electromyographic Activities of the Sternocleidomastoid Muscle during Masticatory Function (저작기능이 흉쇄유돌근의 근활성도에 미치는 영향)

  • Sang-Cheol Yoon;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.18 no.1
    • /
    • pp.55-62
    • /
    • 1993
  • The author has synchronously recorded the average electromyographic activities of the sternocleidomastoid muscles, the anterior temporal muacles and the masseter muscles. The marious levels of occlusal force were checked during clenching the resin plates which are made to fit each of the maxillary and the mandibular teeth. These activities were recorded in order to study the EMG activity pattern of the sternocleidomastoid muscle during the masticatory function of the jaw in 11 healthy subjects. The obtined results were as follows : 1. The electromyographic activities of the sternocleidomastoid muscles, the anterior temporal muscles and the masseter muscles were increased as the occlusal force increased, and the sternocleidomastoid muscles have a lineal correlationship with the occlusal force. 2. The sternocleidomastoid muscles and the masseter muscles showed higher EMG activity during clenching at the ventroflexed head position rather than at the extended head position. (p<0.05) However the EMG activities of the anterior temporal muscles showed no difference between the ventroflexed position and the extended position of the head. 3. The electromyographic activities of the sternocleidomastoid muscles, the anterior temporal muscles and the masseter muscles during clenching are similar at the habitual position and at the retruded condylar position. 4. The electromyographic activities of the sternocleidomastoid muscles, the anterior temporal muscles and the masseter muscles on the working side during mastication of gum and almonds are significantly higher than on the balancing side except the masseter muscles during mastication of almonds. (p<0.05, P<0.01) 5. The asymmetry of gum are lower than that during mastication of almonds. (p<0.05) The asymmetry indices of the sternocleidomastoid muscles are higher than those of the anterior temporal muscles and masseter muscles.

  • PDF

Study on Uncertainty Factors of Head Vibration Measurements

  • Cheung, Wan-Sup;Ryu, Je-Dam;Hong, Dong-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.101-104
    • /
    • 2004
  • This paper addresses uncertainty issues encountered recently in measuring head vibration using the conventional 6-axis or 9-axis bite-bar Those conventional bite-bars are shown to present insufficient information to measure a complete 6 degree-of-freedom motion of head vibration. In order to overcome such limit, a theoretical measurement model that consists of four 3-axis linear accelerometers is suggested (Theoretical backgrounds presented in this paper shall have been addressed in the international congress of ICA 2004 in this April). It is shown to enable the direct measurement of three angular acceleration components and six angular velocity-dependent nonlinear terms. In audition to the three linear acceleration terms, those nine angular motion-dependent ones are found to make it possible to evaluate the general head vibration for a given position. To examine the feasibility of the proposed method, a newly designed 12-axis bite-bar was developed. Detailed experimental results obtained using the developed 12-axis bite-bar are illustrated in the presentation of this paper, which illustrates what amount of measurement accuracy provides. But, this paper provides more detailed experimental data and extended uncertainty factors.

  • PDF

Extended inverse impedance method for multiple branches or loops pipeline systems (복합 관수로에서 인버스 임피던스 확장연구)

  • Dongwon Ko;Sanghyun Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.437-446
    • /
    • 2023
  • We propose a transient evaluation scheme using a pressure measurement in a complicate pipeline systems. Conservation of mass and momentum equations in time domain can be transformed into a pressure head and flowrate relationship between upstream and downstream point in frequency domain. The impedance formulations were derived to address measured pressure at downstream to evaluate of flowrate or pressure head at any point of system. Both branched pipeline element and looped pipeline element can be generally addressed in the platform of the basic reservoir pipeline valve system. The convolution of time domain response function with measured pressure head from a downstream point provides flowrate or pressure head response in any point of the designated pipeline system. The proposed method was validated through comparison between traditional method of characteristics and the proposed method in several hypothetical systems.

Secure and Energy Efficient Protocol based on Cluster for Wireless Sensor Networks (무선 센서 네트워크에서 안전하고 에너지 효율적인 클러스터 기반 프로토콜)

  • Kim, Jin-Su;Lee, Jung-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.14-24
    • /
    • 2010
  • Because WSNs operate with limited resources of sensor nodes, its life is extended by cluster-based routing methods. In this study, we use data on direction, distance, density and residual energy in order to maximize the energy efficiency of cluster-based routing methods. Through this study, we expect to minimize the frequency of isolated nodes when selecting a new cluster head autonomously using information on the direction of the upper cluster head, and to reduce energy consumption by switching sensor nodes, which are included in both of the new cluster and the previous cluster and thus do not need to update information, into the sleep mode and updating information only for newly included sensor nodes at the setup phase using distance data. Furthermore, we enhance overall network efficiency by implementing secure and energy-efficient communication through key management robust against internal and external attacks in cluster-based routing techniques. This study suggests the modified cluster head selection scheme which uses the conserved energy in the steady-state phase by reducing unnecessary communications of unchanged nodes between selected cluster head and previous cluster head in the setup phase, and thus prolongs the network lifetime and provides secure and equal opportunity for being cluster head.

Image Evaluation of Resolution Parameter and Reconstitution Filter in 256 Multi Detector Computed Tomography by Using Head Phantom (256 다중 검출기 전산화단층촬영에서 두개부 전용 팬톰을 이용한 분해능 파라메터와 재구성 필터의 영상 평가)

  • Gu, Bon-Seung;Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.814-821
    • /
    • 2011
  • The purpose of this study was to evaluate of resolution parameter and reconstitution filter in the 256 multi detector computed tomography(MDCT) by using the head phantom. We used 256 MDCT, and head phantom of philips system. We evaluated to image quality by using Extended Brilliance Workspace. The protocol were axial scan method with 120 kVp, 0.5 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of field of view(FOV), $512{\times}512$ of matrix size, 1.0 of pitch, $128{\times}0.625$ mm of collimations. The resolution parameter was applied for 'Standard', 'High' and 'Ultrahigh'. The reconstitution filters were changed to seven type of 'A', 'B', 'C', 'D', 'UA', 'UB', 'UC'. The assesment factors of image quality were the uniformity, the noise, the linearity and 50% and 10% of the modulation transfer function(MTF). Finally The good image quality in 'High' resolution parameter showed at the uniformity, the linearity and 50% and 10% of MTF. The 'UA', 'UB' reconstitution filter showed at the good image quality of the uniformity and the noise and 'C' reconstitution filter showed at the same result of the linearity and 50% and 10% of MTF.

A Study of Form Measurement using Noncontact Sensor (비접촉식 센서를 사용한 형상 측정 연구)

  • 송정섭;황윤호;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone (표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성)

  • Chung Se Young;Chung Hui Young;Kim Young Bum;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF