• Title/Summary/Keyword: Extended chamber

Search Result 67, Processing Time 0.035 seconds

A Study on Development of Ferrite Wave Absorber with Cutting Corn-Shaped Type (원추절단형 페라이트 전파흡수체의 최적설계 및 제작에 관한 연구)

  • 김동일;박종구;정세모;이영구
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.721-726
    • /
    • 2000
  • The remarkable progress of electronics and radio communications technology has made our life abundant. On the other hand, the countermeasure of EMC becomes more important socially according to the increased use of electromagnetic waves. It had been required that the absorbing ability of an electromagnetic wave absorber is mote than 20 dB, the bandwidth of which is required through 30 MHz to 1,000 MHB for satisfying the international standard about an anechoic chamber lot EMl/EMS measurement. From November of 1998, however, the CISPR11 has accepted the extended frequency band from 30 MHz to 18 GHz in the bandwidth of EMI measurement. In this paper, we proposed the cutting corn-shaped type satisfying the above requirements and carried out broadband design using the equivalent material constants method. Moreover, we have fabricated it and compared its characteristics with simulated one.

  • PDF

Cardiac Tumors (심장종양 6례 보고)

  • 김병주
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.667-672
    • /
    • 1985
  • Primary cardiac tumors are uncommon in all age group. In contrast, tumors metastatic to the heart are significantly more common. On rare occasions, tumor may extend into the heart chamber via inferior vena cava from other parts of the body, such as liver, kidney, and uterus cava. With recent advancement in diagnostic imaging modalities and surgical techniques, cardiac tumors are now potentially curably form of heart disease. The most important factor in diagnosing the tumor is a high index of clinical suspicion. Six patients underwent surgical removal of intracardiac tumor during a 5-year period. The mean age of the 4 women and two men was 40 years [range 23 to 60]. All patients were operated on in the last five years of the studied period. All patients had symptoms varying in duration from 1 month to 4 years [average 13 months]. 2-Dimensional echocardiography contributed most to preoperative diagnosis, confirming presence of an intracardiac tumor in all examined patients. Of the six intracardiac tumor, 5 were myxomas [4 left atrial and 1 right ventricular] and one right atrial metastasis from hepatocellular carcinoma of the liver. In all cases, tumor masses were successfully excised. One patient expired after the operation on account of low cardiac out-put syndrome. Remained one patient among six, tumor mass extended into RA and RV with a stalk via IVC. On later follow-up study showed cold area on liver scan [hepatocellular ca.], so she was transferred to internal medicine, department for chemotherapy. Follow up results showed no signs of tumor recurrence in 4 myxoma cases.

  • PDF

Optimization of Flow Uniformity in an Electrostatic Precipitator (ESP) Duct (전기집진기 (ESP) 덕트 내부 유동 균일화를 위한 연구)

  • Junhyung, Hong;Minseung, Hwang;Joungho, Han;Woongchul, Choi;Jeongmo, Seong;Wontae, Hwang
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.86-93
    • /
    • 2022
  • An electrostatic precipitator (ESP) is an industrial post processing facility for high efficiency dust mitigation. Uniformity of the flow passing through the inlet duct leading into the main chamber is important for efficient reduction of dust. To examine flow uniformity, this study conducted a numerical analysis of the flow within a scale-down ESP inlet duct. Magnetic resonance velocimetry (MRV) results from a prior study were utilized to validate the Reynolds-averaged Navier-Stokes (RANS) numerical simulations. Both the experimental and computational results displayed a similar recirculation zone shape and normalized velocity profile near the duct outlet for the baseline geometry. To optimize the uniformity of the flow, the number of guide vanes was modified, and the guide vanes were partially extended straight upward. Design evaluation is done based on the outlet velocity distribution and mass flowrate balance between the two outlets. Simulation results indicate that the vane extension is critical for flow optimization in curved ESP ducts.

Effect of Pressure and Stoichiometric Air Ratio on NOx Emissions in Gas-Turbine Dump Combustor with Double Cone Burner (이중원추형 모형연소기에서 압력과 공기비에 따른 NOx 배출특성)

  • Nam, Dong-Hyun;Nam, Hyun-Su;Han, Dong-Sik;Kim, Gyu-Bo;Cho, Seung-Wan;Kim, Han-Suk;Jeon, Chung-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.251-257
    • /
    • 2012
  • This work presents an experimental investigation of NOx emissions according to inlet air temperature (550-660 K), stoichiometric air ratio (${\lambda}$, 1.4-2.1), and elevated pressure (2-5 bar) in a High Press Combustor (HPC) equipped with a double cone burner, which was designed by Pusan Clean Coal Center (PC3). The exhaust-gas temperature and NOx emissions were measured at the end of the combustion chamber. The NOx emissions generally decreased as a function of increasing ${\lambda}$. On the other hand, NOx emissions were influenced by ${\lambda}$, inlet air temperature and pressure of the combustion chamber. In particular, when the inlet air temperature increased, the flammability limit was extended to leaner conditions. As a result, a higher adiabatic temperature and lower NOx emissions could be achieved under these operation conditions. The NOx emissions that were governed by thermal NOx were greatly increased under elevated pressures, and slightly increased at sufficiently low fuel concentrations (${\lambda}$ >1.8).

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

AN IMMUNOHISTOCHEMICAL STUDY ON THE DISTRIBUTION OF CGRP CONTAINING NERVE FIBERS AFTER PULP EXPOSURE IN RAT MOLAR (흰쥐대구치 치수노출후 치수조직내 CGRP함유 신경섬유의 분포에 관한 면역조직화학적 연구)

  • Kim, Eun-Soung;Park, Il-Yoon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.372-380
    • /
    • 1999
  • The purpose of this study was to investigate the distribution of calcitonin gene-related peptide(CGRP) containing nerve fivers after pulp exposure in rats. The Spague-Dawley rats weighing about 250 - 300g were used. The animals were devided into normal control group and experimental groups. Experimental animals were sacrified on 2, 4, 7, 10 days after pulp exposure. The maxillary teeth and alveolar bone were removed and immersed in the 4% paraformaldehyde plus 0.1M phosphate buffer (pH 7.4). Serial frozen $50{\mu}m$ thick sections were cut with a cryostat. In the immunohistochemical staining procedure, the rabbit CGRP antibody was used as a primary antibody. The sections were incubated for 48 hours at $4^{\circ}C$, and placed into biotinylated anti-rabbit IgG as a secondary antibody and incubated in ABC (avidin-biotin complex), The sections were visualized by 0.05% 3.3 diaminobenzidine tetrahydrochloride. The results of this study were as follows: 1. In control group, CGRP containing nerve fibers ran parallel to the long axis of root and reached the coronal pulp. They were distributed on Raschkow plexus under the odontoblastic layer. 2. In 2 day group after pulp exposure, tissue necrosis and acute inflammation occurred and CGRP containing nerve fibers increased. In 4 day group, the necrotic tissue extended to the pulp and CGRP containing nerve fibers were distributed around the inflammation zone. 3. In 7 day group after pulp exposure, pulp necrosis occurred, and in 10 day group, the abscess under the necrotic pulp extended to the root apex area and CGRP containing nerve fibers were not observed in root canals. 4.The sprouting of CGRP nerve fibers was most remarkable at the pulp chamber under injury in 4 day group, and it was found at inflammation zone under the necrotic tissue in 7 day group and the remaining root pulp tissue in 10 day group. As mentioned above, CGRP nerve fibers had a tendency to increase around the inflammatory zone, especially around the acute inflammation tissue, when compared with control group. It is suggested that CGRP nerve fibers maybe related to the control of inflammatory response of pulp tissue.

  • PDF

Change of Sperm Viability and Acrosome Integrity of Post-thawed Korean Jeju Black Bull Spermatozoa according to Glycerol Concentration (제주 흑우 동결 정액 제조에 있어 Glycerol의 농도에 따른 생존율 및 정자 첨체 양상의 변화)

  • Choi, Sun-Ho;Ko, Min-Hee;Kang, Tae-Young;Cho, Sang-Rae;Park, Yong-Sang;Oh, Shin-Ae
    • Journal of Embryo Transfer
    • /
    • v.26 no.3
    • /
    • pp.187-193
    • /
    • 2011
  • This study was carried out to establish most suitable freezing condition, to evaluate the different glycerol concentration of freezing and thawing rates on motility, viability, membrane integrity and acrosome intecrity of frozen Korean Jeju Black Bull spermatozoa, Semen was collected from a Korean Jeju Black Bull using an artificial vagina and transported to the laboratory. The semen was extended gradually 1:5 then cooled slowly for 2 hrs to 4$^{\circ}C$. The semen was diluted 1:1 with cryoprotectant extenders (3%, 5% and 7% glycerol) and equilibrated for 2 hrs at cold chamber and packed to 0.5 ml straws. The semen straws were located above 3 cm of liquid nitrogen for 5 minutes, above 5 cm for 10 min and above 8 cm for 10 min. And then the frozen straw was plunged into LN$_2$. The presented straws were examined the viability and motility after thawed at 37$^{\circ}C$ water bath. The viability and membrane integrity immediately post-thawing were significantly higher in samples frozen in 7% glycerol than 3% and 5% glycerol (p<0.05). After CTC staining to assess acrosome integrity, F pattern was significantly increased, but B pattern was significantly decreased in 7% glycerol (p<0.05). Freezing distance of 5 cm from liquid nitrogen and pre-cooling for 10 min yield better survival and membrane integrity, but not significant difference. However, AR pattern according to CTC staining was significantly decreased in 3 cm for 5 min.

A Study on the Dieless Wire Drawing Using Microwave (마이크로웨이브를 이용한 Dieless Wire Drawing 에 대한 연구)

  • Huh You;Kim S.H.;Kim J.S.;Kim I.S.;Paik Y.N.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.942-945
    • /
    • 2005
  • Micron-sized metal wires are widely used in industries such as filtration, catalyst and composite materials, etc. In the wire drawing process, the die that is used conventionally is an effective and, at the same time, sensitive component. However, a typical array of the dies has caused many problems in the wire drawing process, e.g., large frictional force on the interface between wire and the resulting high heat generation, precise adjustment of the dies, extended cooling system, die abrasion, etc.. Because of these problems, there have been many works that are aiming at improving the efficiency of wire drawing process by analyzing the die geometry and by applying advanced die material to prolong the die life or even at developing a dieless wire drawing system. This paper is dealing with developing a new wire drawing system that is applicable to reduce the wire drawing steps with high draw ratio. The new wire drawing system does not use the dies, but use the self-induced heater that works on the basis of the resonant phenomenon of wire material. The electromagnetic wave is the heating source. The results of the study on the diameter reduction and microwave flow analysis show that the heating effectiveness of the wire is influenced by the energy distribution in the microwave propagation chamber. We can obtain diameter-reduced wires by using microwave in the dieless drawing process. Microwave as a heating source is capable of producing wires without applying dies in wire drawing process.

  • PDF

Development of Calibration System of Helium Permeation Type Standard Leaks (헬륨 투과형 표준리크 교정장치 개발)

  • Hong S.S.;Lim I.T.;Shin Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.347-353
    • /
    • 2006
  • A helium permeation type standard leak calibration system has newly developed by using dynamic gas expansion method. The measurement range was extended lower to $10^{-6}$ Pa L/s for participating CCM (Consultative Committee for Mass and Related Quantities) standard leak key comparison. For the system, pressure ratios of high and ultra-high vacuum chamber and porous plug conductance for helium gas were determined. By using the system, a permeation type standard leak of $5.6{\times}10^{-4}$ Pa L/s range was calibrated. The calibration result showed that the difference between standard commercial leak was 11.1 %.