• Title/Summary/Keyword: Extended Frequency Response

Search Result 91, Processing Time 0.029 seconds

Quantitative Flood Forecasting Using Remotely-Sensed Data and Neural Networks

  • Kim, Gwangseob
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2002.05a
    • /
    • pp.43-50
    • /
    • 2002
  • Accurate quantitative forecasting of rainfall for basins with a short response time is essential to predict streamflow and flash floods. Previously, neural networks were used to develop a Quantitative Precipitation Forecasting (QPF) model that highly improved forecasting skill at specific locations in Pennsylvania, using both Numerical Weather Prediction (NWP) output and rainfall and radiosonde data. The objective of this study was to improve an existing artificial neural network model and incorporate the evolving structure and frequency of intense weather systems in the mid-Atlantic region of the United States for improved flood forecasting. Besides using radiosonde and rainfall data, the model also used the satellite-derived characteristics of storm systems such as tropical cyclones, mesoscale convective complex systems and convective cloud clusters as input. The convective classification and tracking system (CCATS) was used to identify and quantify storm properties such as life time, area, eccentricity, and track. As in standard expert prediction systems, the fundamental structure of the neural network model was learned from the hydroclimatology of the relationships between weather system, rainfall production and streamflow response in the study area. The new Quantitative Flood Forecasting (QFF) model was applied to predict streamflow peaks with lead-times of 18 and 24 hours over a five year period in 4 watersheds on the leeward side of the Appalachian mountains in the mid-Atlantic region. Threat scores consistently above .6 and close to 0.8 ∼ 0.9 were obtained fur 18 hour lead-time forecasts, and skill scores of at least 4% and up to 6% were attained for the 24 hour lead-time forecasts. This work demonstrates that multisensor data cast into an expert information system such as neural networks, if built upon scientific understanding of regional hydrometeorology, can lead to significant gains in the forecast skill of extreme rainfall and associated floods. In particular, this study validates our hypothesis that accurate and extended flood forecast lead-times can be attained by taking into consideration the synoptic evolution of atmospheric conditions extracted from the analysis of large-area remotely sensed imagery While physically-based numerical weather prediction and river routing models cannot accurately depict complex natural non-linear processes, and thus have difficulty in simulating extreme events such as heavy rainfall and floods, data-driven approaches should be viewed as a strong alternative in operational hydrology. This is especially more pertinent at a time when the diversity of sensors in satellites and ground-based operational weather monitoring systems provide large volumes of data on a real-time basis.

  • PDF

A study on influential factors for dental hygiene students' image of dental hygienist (치위생과 학생들의 치과위생사 이미지에 영향을 미치는 요인 연구)

  • Lee, Kyeong-Hee;Yoon, Mi-Sook;Ha, Myung-Ok
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.5
    • /
    • pp.831-839
    • /
    • 2010
  • Objectives : The purpose of this study was to examine dental hygiene students' image of dental hygienist and factors affecting the image of dental hygienist in an effort to provide some information useful for dental hygiene education. It's basically meant to recreate the image of dental hygienist as a professional. Methods : The subjects in this study were 310 sophomores and seniors who ere selected by convenience sampling from three different three-year-course colleges located in Gyeonggi Province, Chungcheong Province and Gwangju. After a survey was conducted, the answer sheets from 277 respondents were analyzed except for 33 incomplete ones. The collected data were analyzed with a SPSSWIN 17.0 program, and statistical data on frequency and percentage were obtained to find out the general characteristics of the subjects, and another statistical data on mean and standard deviation for each item were acquired to check their image of dental hygienist. Besides, t-test, ANOVA and Kruscal-Wallis test, one of nonparametric test, were utilized to look for connections between their general characteristics and image of dental hygienist. Results : 1. They gave a mean of 3.53 to the image of dental hygienist, which showed that the dental hygiene students took a favorable view of dental hygienists in general. 2. Their response to four items showed that they looked at the image of dental hygienist in a positive manner. The four items respectively described dental hygienists as professionals, as ones who played a crucial role in the improvement of national oral health, as ones with professional knowledge and sophisticated knowhow, and as neat and decent people. And their response to the following five items indicated that they looked at the image of dental hygienists in a negative way. One was that dental hygienists were considered to be dental nurses, and another was that the occupation of dental hygienist was a demanding and stressful job. The third was that there was no single, fixed title to call dental hygienists, and the fourth was that dental hygiene wasn't recognized as an independent area. The fifth was that the social standing of dental hygienists was sort of high. 3. In regard to the impact of the general characteristics of the dental hygiene students on their image of dental hygienist, they had a more favorable image of dental hygienist when they perceived dental hygiene in a more positive manner(p<0.001). Conclusions : In order to boost the image of dental hygienist, the working conditions of dental hygienists should be improved, and educational programs should be prepared to provided them extended continuing educational opportunities. And the kind of educational environments that could nurture dental hygienists who are convinced and have a vision should be created.

Propagation characteristics of blast-induced vibration to fractured zone (파쇄영역에 따른 발파진동 전파특성)

  • Ahn, Jae-Kwang;Park, Duhee;Park, Ki-Chun;Yoon, Ji Nam
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.959-972
    • /
    • 2017
  • In evaluation of blast-induced vibration, peak particle velocity (PPV) is generally calculated by using attenuation relation curve. Calculated velocity is compared with the value in legal requirements or the standards to determine the stability. Attenuation relation curve varies depending on frequency of test blasting, geological structure of the site and blasting condition, so it is difficult to predict accurately using such an equation. Since PPV is response value from the ground, direct evaluation of the structure is impractical. Because of such a limit, engineers tend to use the commercial numerical analysis program in evaluating the stability of the structure more accurately. However, when simulate the explosion process using existing numerical analysis program, it's never easy to accurately simulate the complex conditions (fracture, crushing, cracks and plastic deformation) around blasting hole. For simulating such a process, the range for modelling will be limited due to the maximum node count and it requires extended calculation time as well. Thus, this study is intended to simulate the elastic energy after fractured zone only, instead of simulating the complex conditions of the rock that results from the blast, and the analysis of response characteristics of the velocity depending on shape and size of the fractured zone was conducted. As a result, difference in velocity and attenuation character were calculated depending on fractured zone around the blast source appeared. Propagation of vibration tended to spread spherically as it is distanced farther from the blast source.

Parishioner's role Expectations of Parish Nursing (한국 교인들의 목회간호 역할기대)

  • Kim, Chung-Nam;Kwon, Young-Sook
    • Research in Community and Public Health Nursing
    • /
    • v.11 no.1
    • /
    • pp.231-244
    • /
    • 2000
  • Parish nursing is a community health nursing role developed in 1983 by Lutheran Chaplain Granger Westberg. An increasing emphasis on holistic care, personal responsibility for a healthy lifestyle, and changes in healthcare delivery systems have undoubtedly facilitated the establishment of an innovative nursing role in the community. Parish nurses are functioning in a variety of church congregations of various denominations. The parish nurse is a educator, a personal health counselor, a coordinator of volunteers. The parish nurses helps people relate to the complexed medical care system and assists people to integrate faith and health. The purpose of this study is to investigate what the korean parishioners want in parish nursing and what type of role expectation from parish nurse. The subjects were 1138 parishioners of 23 churches of various denominations in nationwide Korea. Data were collected by self-reported question naires from Feb 4 to June 25. 1999. The data were analyzed by using percentage. frequency. $x^2-test$. multiple Response set with SPSS program. The results are as follows: 1. Desired parish nursing contents by parish nurses are: psychological counselling(23.4%) out of private counselling. stress management(21.1 %) out of private health education. Emergency care(14.1%) out of group health education. Blood Pressure check-ups (19.0%) out of Health check ups. home visiting(44.9%) out of patient visiting method. B T. pulse, respiration and blood pressure check(15.0%) in Care to serve in home visiting. spiritual preparation to accept the death(41.7%) in hospice care, advices to choice of medical treatment using guide(50.1%) in introducing and guiding of health care facilities, pray(21.7%) in spiritual care' faith support. 2. Desired Health Teaching Content According to Period of Clients by Parish Nurse are: Vaccination(22.5%) in infant and toddler health management. sexual education(25.3%) in adolescent health management. prenatal care (29.5%) in pregnant health management. osteoporosis prevention and management (22.4%) in Middle aged health management. dementia prevention and management(25.5%) in elderly health management. 3. The expectant role from parish nurse is spiritual care faith support(14.1%). patient visiting care(13.2%), hospice care(12.9%), private counseling(12.8%), health check ups (11.1 %), volunteer organization and training out of believer(11.0%), private health education (9.3%), group health education (8.3%). 4. In Necessity of Performing Parish Nursing according to Region, Most(over 95%) responded that nursing program is needed. so there is no significance between regions. In Performing Parish Nursing in their church, Most(92.2%) responded they want to perform program. 5. In case of performing parish nursing, 52% out of the subjects responded they want to participated in parish nursing volunteer's activity, for example. to be in active to be a companion to chat(42.1%), necessity support (25.3%), donation support(25.0%), exercise support(18.2%), vehicles support (9.9%). As a result. in holistic care and spiritual care, the need of parish nursing and the role expectation from parish nurse are very high among korean believers. Therefore, I suggest parish nursing centering around Taegu and Kyungbuk province should be extended to nationwide. For extending parish nursing program. more active advertisement and research is needed. After performing parish nursing program through out the country, further comparative research between regions should be practiced and Korean parish nursing program will be developed and activated.

  • PDF

Recent Research Trends of Supercapacitors for Energy Storage Systems (에너지 저장시스템을 위한 슈퍼커패시터 최신 연구 동향)

  • Son, MyungSuk;Ryu, JunHyung
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.277-290
    • /
    • 2021
  • A supercapacitor, also called an ultracapacitor or an electrochemical capacitor, stores electrochemical energy by the adsorption/desorption of electrolytic ions or a fast and reversible redox reaction at the electrode surface, which is distinct from the chemical reaction of a battery. A supercapacitor features high specific power, high capacitance, almost infinite cyclability (~ 100,000 cycle), short charging time, good stability, low maintenance cost, and fast frequency response. Supercapacitors have been used in electronic devices to meet the requirements of rapid charging/discharging, such as for memory back-up, and uninterruptible power supply (UPS). Also, their use is being extended to transportation and large industry applications that require high power/energy density, such as for electric vehicles and power quality systems of smart grids. In power generation using intermittent power sources such as solar and wind, a supercapacitor is configured in the energy storage system together with a battery to compensate for the relatively slow charging/discharging time of the battery, to contribute to extending the lifecycle of the battery, and to improve the system power quality. This article provides a concise overview of the principles, mechanisms, and classification of energy storage of supercapacitors in accordance with the electrode materials. Also, it provides a review of the status of recent research and patent, product, and market trends in supercapacitor technology. There are many challenges to be solved to meet industrial demands such as for high voltage module technologies, high efficiency charging, safety, performance improvement, and competitive prices.

Application of a Geographically Weighted Poisson Regression Analysis to Explore Spatial Varying Relationship Between Highly Pathogenic Avian Influenza Incidence and Associated Determinants (공간가중 포아송 회귀모형을 이용한 고병원성 조류인플루엔자 발생에 영향을 미치는 결정인자의 공간이질성 분석)

  • Choi, Sung-Hyun;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.36 no.1
    • /
    • pp.7-14
    • /
    • 2019
  • In South Korea, six large outbreaks of highly pathogenic avian influenza (HPAI) have occurred since the first confirmation in 2003 from chickens. For the past 15 years, HPAI outbreaks have become an annual phenomenon throughout the country and has extended to wider regions, across rural and urban environments. An understanding of the spatial epidemiology of HPAI occurrence is essential in assessing and managing the risk of the infection; however, local spatial variations of relationship between HPAI incidences in Korea and related risk factors have rarely been derived. This study examined whether spatial heterogeneity exists in this relationship, using a geographically weighted Poisson regression (GWPR) model. The outcome variable was the number of HPAI-positive farms at 252 Si-Gun-Gu (administrative boundaries in Korea) level notified to government authority during the period from January 2014 to April 2016. This response variable was regressed to a set of sociodemographic and topographic predictors, including the number of wild birds infected with HPAI virus, the number of wintering birds and their species migrated into Korea, the movement frequency of vehicles carrying animals, the volume of manure treated per day, the number of livestock farms, and mean elevation. Both global and local modeling techniques were employed to fit the model. From 2014 to 2016, a total of 403 HPAI-positive farms were reported with high incidence especially in western coastal regions, ranging from 0 to 74. The results of this study show that local model (adjusted R-square = 0.801, AIC = 954.5) has great advantages over corresponding global model (adjusted R-square = 0.408, AIC = 2323.1) in terms of model fitting and performance. The relationship between HPAI incidence in Korea and seven predictors under consideration were significantly spatially non-stationary, contrary to assumptions in the global model. The comparison between global Poisson and GWPR results indicated that a place-specific spatial analysis not only fit the data better, but also provided insights into understanding the non-stationarity of the associations between the HPAI and associated determinants. We demonstrated that an empirically derived GWPR model has the potential to serve as a useful tool for assessing spatially varying characteristics of HPAI incidences for a given local area and predicting the risk area of HPAI occurrence. Considering the prominent burden of HPAI this study provides more insights into spatial targeting of enhanced surveillance and control strategies in high-risk regions against HPAI outbreaks.

의료인의 호스피스가정간호에 대한 지식과 태도 조사연구

  • Kim, Ok-Gyeom
    • Korean Journal of Hospice Care
    • /
    • v.2 no.2
    • /
    • pp.28-48
    • /
    • 2002
  • The advances of medical technologies have not only prolonged human life span, but also extended suffering period for the patients with incurable medical diseases. Hospice movement was developed to help these patients keep dignity and lives peaceful at the end of their life. Since many patients prefer to spend the last moment of life at home with their family, hospice home care has become very popular worldwide. The purpose of this study for a promotion and development of hospice home care in Korea, and features basic research on medical profession's knowledge and attitudes to hospice home care. This study which was used for the research questionnaires developed by the researcher that were answered by 100 physicians and 127 nurses in a general hospital. Data were collected from April 22, 2002 to May 10, 2002. The SPSS was used to make a comparative analysis of the frequency, percentile, ANOVA, and x2-test. The results of the study were as follows; 1.The medical profession showed high level of knowledge of the definition and philosophy of hospice. However, the physician group of the examinees showed insufficient knowledge of the fact that hospice care includes bereavement care, while the nurse group's response to the same question showed a significant difference(x2=10.752, p=.001). 2.For whom the hospice home care is provided, 95.6% of the respondents showed very high level of knowledge as answering that the incurable terminal illness patients and their families are the beneficiaries of hospice care. The respondents counted nurses, volunteers, pastors, physicians and social workers, consecutively, as hospice care providers. More nurse were positive toward pastors than physicians in regarding as a hospice care provider by a significant difference(x2=11.634, p=.001). 3.For when to referral hospice home care to the patients, only 34.2% answered that patients with less than 6 months of survival time are advised to receive hospice care, reflecting very low level of knowledge. 23.0% of the physicians and 48.0% of the nurses answered that hospice care should be provided when death is imminent, making a significant difference between the two groups(x2=6.413, p=.000). 4.To promote hospice activities, 87.2% pointed out that it is crucial to make general people, including those engaging in the medical field, more aware of hospice. 79.7% answered that a national hospice management should be developed, marking a significant difference between the physician group and nurse group(x2=10.485, p=.001). 5.Advantages of hospice home care are 87.2% responded that patients can have better rest at home receiving hospice home care. Economical merit was brought forward as one of the advantages also, where there was a significant difference between the physicians group and nurse group(x2=7.009, p=.008). 6.The medical professions' attitude to hospice home care are 92.8% of the physicians answered that they would advise incurable terminally ill patients to be discharged from hospital, with 44.3% of them advising the patients to receive hospice home care after leaving the hospital. From the nurses' point of view, 20.9% of the terminally ill patients are being referred to hospice home care after discharge, which makes a significant difference from the physicians' response(x2=19.121, p=.001). 7. 30.6% of physicians have referred terminally ill patients to hospice home care, 75.9% of whom were satisfied with their decision. Those physicians who have never referred their patients to hospice home care either did not know how to do it(66.7%) or were afraid of losing trust by giving the patients an impression of giving up(27.3%). 94.9% of the physicians responded that they would refer their last stage patients to a doctor who is involving palliative care. 8.Only 36.2% of nurses have suggested to physicians that refer the terminally ill patients discharged from the hospital to hospice home care. Once suggested, 95.8% of the physicians have accepted the suggestion. Nurses were reluctant to suggest hospice home care to the physicians, as 48.8% of the nurses said they did not want to. From the result of this study the following conclusion can be drawn, the medical profession's awareness of general hospice care has been increased greatly compared to the results of the previously performed studies. However, this study result also shows that their knowledge of hospice home care is not good enough yet. There is a need for high recommended that medical education institute and develop regular courses on various types of hospice care. Medical field training courses for physicians and nurses will be very helpful as well. It is also important to train hospice experts such as palliative physicians and develop a national hospice management urgently in order to improve the hospice care in Korea.

  • PDF

Aesthetic study on significance of equal temperament of Siakhwaseong (『시악화성(詩樂和聲)』의 평균율(平均律)의 의의(意義)에 관한 미학적(美學的) 탐구(探究))

  • Lee, jong jin
    • (The)Study of the Eastern Classic
    • /
    • no.62
    • /
    • pp.291-319
    • /
    • 2016
  • The purpose of this study is aesthetical inquiry on agreement inherent in the 'Pyeongkunyul of "Siakhwaseong" "Yulryo" is to have come from the 'Taekuk'. as the structure of 'Yumyaungdaedae' which 'represents a "Dosu". it becomes "Habsanweil" and it consists of "HwangjongYul" on it. There are two kinds of ways to "Pyeongkunyul" and "Sambunsonikyul". "PyeongkunYul is characterized by soundly solving the challenges of the "Jueibulban". "Yulryo" is to pursue a 'Hwa' through that "Eum" response each other. The human ear to listen to "Yul" and can be divided "Yul" because the same "Eum" is to meet with one another. The other two 'Eum' at the same time the "Maeknory" is caused by the ratio of the frequency. because "Hwaibudong". In the "DongEum" and 'octave of Eum' is not a "Maeknory" when listening ear of a person 'Dong'. In contrast, "Hwa" is a sound relationship revealed in "12Yul" in "Dong Eum" with the exception of 'octaves of Eum', that is the most easy to hear 4Do(5Do) at "Yulryo" From the point of view for "Joenchecaeyong", 4do forms a pure sound there is no Maeknory, such as "Dongeum", only partial ones in the "12Yul" by "Sambunsonik". 4Do(5Do) in "Pyeongkunyul" although though the "Maeknory" of about times put to 3 seconds to occur, so that makes the perfect "Hwa" in all of the "12Yul" "Yulryo" is apparent to the sound. "YangYul" and "Eumryo" that began from "Taekuk" which must be extended to the same "Eumga" Therefore "12Yul" consisting "Pyeongkunyul" is based on the "Yackry" of "Habsanweil" As a whole to achieve the overall Harmony and based on the As aesthetical on agreement inherent of "Hwa".

A Study on Modernization of International Conventions Relating to Aviation Security and Implementation of National Legislation (항공보안 관련 국제협약의 현대화와 국내입법의 이행 연구)

  • Lee, Kang-Bin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.30 no.2
    • /
    • pp.201-248
    • /
    • 2015
  • In Korea the number of unlawful interference act on board aircrafts has been increased continuously according to the growth of aviation demand, and there were 55 incidents in 2000, followed by 354 incidents in 2014, and an average of 211 incidents a year over the past five years. In 1963, a number of states adopted the Convention on Offences and Certain Other Acts Committed on Board Aircraft (the Tokyo Convention 1963) as the first worldwide international legal instrument on aviation security. The Tokyo Convention took effect in 1969 and, shortly afterward, in 1970 the Convention for the Suppression of Unlawful Seizure of Aircraft(the Hague Convention 1970) was adopted, and the Convention for the Suppression of Unlawful Acts Against the Safety of Civil Aviation(the Montreal Convention 1971) was adopted in 1971. After 9/11 incidents in 2001, to amend and supplement the Montreal Convention 1971, the Convention on the Suppression of Unlawful Acts Relating to International Civil Aviation(the Beijing Convention 2010) was adopted in 2010, and to supplement the Hague Convention 1970, the Protocol Supplementary to the Convention for the Suppression of Unlawful Seizure of Aircraft(the Beijing Protocol 2010) was adopted in 2010. Since then, in response to increased cases of unruly behavior on board aircrafts which escalated in both severity and frequency,, the Montreal Protocol which is seen as an amendment to the Convention on Offences and Certain Other Acts Committed on Board Aircraft(the Tokyo Convention 1963) was adopted in 2014. Korea ratified the Tokyo Convention 1963, the Hague Convention 1970, the Montreal Convention 1971, the Montreal Supplementary Protocol 1988, and the Convention on the Marking of Plastic Explosive 1991 which have proven to be effective. Under the Tokyo Convention ratified in 1970, Korea further enacted the Aircraft Navigation Safety Act in 1974, as well as the Aviation Safety and Security Act that replaced the Aircraft Navigation Safety Act in August 2002. Meanwhile, the title of the Aviation Safety and Security Act was changed to the Aviation Security Act in April 2014. The Aviation Security Act is essentially an implementing legislation of the Tokyo Convention and Hague Convention. Also the language of the Aviation Security Act is generally broader than the unruly and disruptive behavior in Sections 1-3 of the model legislation in ICAO Circular 288. The Aviation Security Act has reflected the considerable parts of the implementation of national legislation under the Beijing Convention and Beijing Protocol 2010, and the Montreal Protocol 2014 that are the modernized international conventions relating to aviation security. However, in future, when these international conventions would come into effect and Korea would ratify them, the national legislation that should be amended or provided newly in the Aviation Security Act are as followings : The jurisdiction, the definition of 'in flight', the immunity from the actions against the aircraft commander, etc., the compulsory delivery of the offender by the aircraft commander, etc., the strengthening of penalty on the person breaking the law, the enlargement of application to the accomplice, and the observance of international convention. Among them, particularly the Korean legislation is silent on the scope of the jurisdiction. Therefore, in order for jurisdiction to be extended to the extra-territorial cases of unruly and disruptive offences, it is desirable that either the Aviation Security Act or the general Crime Codes should be revised. In conclusion, in order to meet the intelligent and diverse aviation threats, the Korean government should review closely the contents of international conventions relating to aviation security and the current ratification status of international conventions by each state, and make effort to improve the legislation relating to aviation security and the aviation security system for the ratification of international conventions and the implementation of national legislation under international conventions.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF