• Title/Summary/Keyword: Exposure fire

Search Result 266, Processing Time 0.03 seconds

Expected Damage Analysis of Risk Exposure Object by Violation Rate of Safety Distance in Explosion of Ground Type Magazine (지상형 탄약고 폭발 시 안전거리 위반율에 따른 위험노출대상의 피해 수준 분석 연구)

  • Ham, Tae Yuun;Lee, Jae Joon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.92-100
    • /
    • 2022
  • Of the Korean military's 3,959 ammunition depots, 1,007 - more than 25% - violate safety requirements for distance and equipment. There is a risk of explosion in old depots that are vulnerable to various interior and exterior accidents. This paper examines 10 scenarios, with varying values for ammunition amount and safety distance. The study calculated the overpressure that can be applied to risk-exposure objects, based on the safety distance; expected damage was predicted using constructed spatial information from 3D explosion simulations. The simulations confirmed that explosion overpressure increased the most when the safety distance violation rate increased from 80% to 90%. It also confirmed that secondary damage such as fire and explosion can cause casualties and property damage when the violation rate is 60% or higher. The results show that building collapse becomes a risk with a violation rate of 70% or higher. We conclude that taking ammunition depot safety distance violation into account when planning military facilities and their land utilization could better protect life and property.

The Combustion Gases Toxicity Evaluation of Plastics Material by Colorimetric Gas Detector Tubes (가스검지관법에 의한 플라스틱재료의 연소가스 독성평가)

  • 박영근;김동일;현성호
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.77-84
    • /
    • 2002
  • In this paper, we had analyzed comsbustion gases using a GASTEC colorimetric gas detector tube according to the method of NES 713 in order to combustion gases toxicity evaluation for beads polystyrene foam, extruded polystyrene foam, rigid polyurethane foam, flexible polyurethane foam, flexible polyvinyl chloride pipe, vinyl floor cover, polyethyelene foam(flame retardant untreated) and polyethyelene foam (flame retardant treated) of plastics material. As results of gas analyses by using this method, comsbustion gases producted from small specimens of plastics material had reached fatal to man at 30 minutes exposure time that had possesed toxicity index of more than 1. Toxicity indexes of each specimen were estimated range of 4.3∼179.2, flexible polyvinyl chloride showed the hightest toxicity index at 179.2, and beads polystyrene foams showed the lowest toxicity index at 4.3.

Mock-Up Test for the Fire Resistance Analysis of High Strength RC Beam and Slab Using the Polylon Fiber (폴리론 화이버를 혼입한 고강도 RC 보 및 슬래브의 내화특성 분석을 위한 Mock-Up 실험)

  • Son, Ho Jung;Hwang, Dong Gyu;Hann, Chang Pyung;Han, Min Cheol;Yang, Seong Hwan;Han, Cheon Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.93-96
    • /
    • 2009
  • The objective of this study is to analyze the insulation characteristics of the polylon hybrid fiber inserted high-strength RC beam and slab produced as a single body and the results of this study can be summarized as follows. In the spalling mechanism as an insulation characteristic, the slab of the single body type specimen shows an exposure in concrete covers at the center of slab and that leads to the spalling, which exposures reinforcing bars. In the case of the beam, the spalling was presented at several sections as a type of peel spalling before and after 10 minutes from the insulation test. Whereas, although the internal temperature history of concrete represents the highest range as 581℃ in the case of the center of the bottom of beam base, it can be considered that it satisfies the regulation of insulation certification.

  • PDF

Low Temperature Plasma Treatment of Linseed Oil for Immobilization of Silica as Flame-resistant Material (방염용 실리카의 고정화를 위한 아마인유의 저온플라즈마처리)

  • Seo, Eun-Deock
    • Textile Coloration and Finishing
    • /
    • v.24 no.4
    • /
    • pp.313-320
    • /
    • 2012
  • For the preparation of hardened films which can be applied as a binder for flame-resistant materials such as silica, linseed oil was subjected to a low temperature plasma treatment with argon, or oxygen gas. The film was produced much faster than so-called drying of oil in air. The SEM analysis for silica particles embedded in the hardened film after plasma treatment showed that the silica particles were immobilized on substrate and were evenly dispersed. The FT-IR spectral analysis for the plasma-treated linseed oil films demonstrated that the radicals which were formed during the plasma treatments caused the linseed oil to be cross-linked, and the plasmas attacked carbon chains of the oil randomly without focusing on specific vulnerable bonds such carbon double and carbonyl bonds intensively unless exposure times of the plasmas were prolonged too much, while the cross-linking of the air-dried film was considered to occur at the well-known typical sites, i.e., carbon-carbon double bond and ${\alpha}$-methylene carbon. Burning times, as a measure of flame/fire resistance, of silica-filled cellulose substrates, increased with increasing contents of silica.

Analysis of Fire Damaged Concrete Ca(OH)2 by Heating Temperature Using Scanning Electron Microscope and X-ray Diffraction (SEM과 XRD를 이용한 수열온도별 화재피해 콘크리트의 Ca(OH)2 분석)

  • Lim, Gun-Su;Han, Soo-Hwan;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.149-150
    • /
    • 2022
  • In Korea, there is no clearly established technology for diagnosing and evaluating the damage depth of concrete structures created by fire. There have been cases of repairing, reinforcing, and demolishing degraded structures without diagnosing the damage depth. The commonly used phenolphthalein-based carbonate thickness measurement does not satisfy the complete disappearance condition of Ca(OH)2 in the interval where the relatively stationary flow declines after exposure to high temperatures. Even a small amount of Portlandite[Ca(OH)2] reacts with a red color, and the damage depth is misjudged. It was confirmed by X-ray diffraction and scanning electron microscope that Ca(OH)2 existed from 300℃ to 500℃ where the residual compressive strength decreased.

  • PDF

Scientific Analysis of Firing Characteristics for Walls and Rooftiles Excavated from Jeseoksa Dump-site, Iksan (익산 제석사지 폐기유적 벽체 및 기와의 피열특성)

  • Ahn, Kyoung Suk;Lee, Min Hye;Han, Min Su
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.567-578
    • /
    • 2021
  • In this study, the physicochemical properties of 21 wall fragments and rooftile pieces excavated from Jeseoksa Dump-site were analyzed, and the possibility of heat exposure, such as the fire reported in the literature, was investigated by estimating the firing temperature. From the results, it was estimated that the rooftiles were composed of refined materials, and the walls were composed of materials having different particle sizes depending on the layer. Unlike ordinary rooftiles and walls, they exhibited an uneven surface with traces of bloating phenomenon in the cross section. It was estimated from the blackening of some portions that firing was not performed in a controlled state in a constant firing environment. In addition, the estimated firing temperature showed that the non-overfired rooftiles had endured a firing temperature of 900℃ or less, but the over-fired samples were subjected to a temperature of 1,000℃ or higher and were fired at a temperature higher than the manufacturing temperature at that time. Additionally, the rooftiles probably became defective during firing or molding at the time of production, but the non-overfired rooftiles exhibited an intact shape and showed the possibility of heat exposure due to fire. Therefore, the analytical results of this study confirm that the defective architectural components damaged by the fire, as reported in the literature, were discarded in the Jeseoksa dump-site.

Radiological Safety Assessment of Transporting Radioactive Wastes to the Gyeongju Disposal Facility in Korea

  • Jeong, Jongtae;Baik, Min Hoon;Kang, Mun Ja;Ahn, Hong-Joo;Hwang, Doo-Seong;Hong, Dae Seok;Jeong, Yong-Hwan;Kim, Kyungsu
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1368-1375
    • /
    • 2016
  • A radiological safety assessment study was performed for the transportation of low level radioactive wastes which are temporarily stored in Korea Atomic Energy Research Institute (KAERI), Daejeon, Korea. We considered two kinds of wastes: (1) operation wastes generated from the routine operation of facilities; and (2) decommissioning wastes generated from the decommissioning of a research reactor in KAERI. The important part of the radiological safety assessment is related to the exposure dose assessment for the incidentfree (normal) transportation of wastes, i.e., the radiation exposure of transport personnel, radiation workers for loading and unloading of radioactive waste drums, and the general public. The effective doses were estimated based on the detailed information on the transportation plan and on the radiological characteristics of waste packages. We also estimated radiological risks and the effective doses for the general public resulting from accidents such as an impact and a fire caused by the impact during the transportation. According to the results, the effective doses for transport personnel, radiation workers, and the general public are far below the regulatory limits. Therefore, we can secure safety from the viewpoint of radiological safety for all situations during the transportation of radioactive wastes which have been stored temporarily in KAERI.

Effect of Ambient Air Pollution on Years of Life Lost from Deaths due to Injury in Seoul, South Korea (대기오염물질이 손상으로 인한 손실수명연수에 미치는 영향: 서울특별시를 중심으로)

  • Sun-Woo Kang;Subin Jeong;Hyewon Lee
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.3
    • /
    • pp.149-158
    • /
    • 2023
  • Background: Injury is one of the major health problems in South Korea. Few studies have evaluated both intentional and unintentional injury when investigating the association between exposure to air pollutants and injury. Objectives: We aimed to explore the association between short-term exposure to ambient air pollution and years of life lost (YLLs) due to injury. Methods: Data on daily YLLs for 2002~2019 were obtained from the the Death Statistics Database of the Korean National Statistical Office. This study estimated short-term exposure to particulate matter with an aerodynamic diameter of <10 ㎛ (PM10), particulate matter with an aerodynamic diameter of <2.5 ㎛ (PM2.5), sulfur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO), and ozone (O3). This time series study was conducted using a generalized additive model (GAM) assuming a Gaussian distribution. We also evaluated a delayed effect of ambient air pollution by constructing a lag structure up to seven days. The best-fitting lag was selected based on smallest generalized cross validation (GCV) value. To explore effect modification by intentionality of injury (i.e., intentional injury [self-harm, assault] and unintentional injury), we conducted stratified subgroup analyses. Additionally, we stratified unintentional injury by mechanism (traffic accident, fall, etc.). Results: During the study period, the average daily YLLs due to injury was 307.5 years. In the intentional injury, YLLs due to self-harm and assault showed positive association with air pollutants. In the unintentional injury, YLLs due to fall, electric current, fire and poisoning showed positive association with air pollutants, whereas YLLs due to traffic accident, mechanical force and drowning/submersion showed negative associations with air pollutants. Conclusions: Injury is recognized as preventable, and effective strategies to create a safe society are important. Therefore, we need to establish strategies to prevent injury and consider air pollutants in this regard.

Performance of Hybrid Fiber Reinforced Concrete at Elevated High Temperature (고온에서 하이브리드 섬유보강 콘크리트의 성능)

  • Won, Jong-Pil;Park, Kyung-Hoon;Park, Chan-Gi
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.325-333
    • /
    • 2008
  • This study evaluated the mechanical performance, shrinkage crack and fire resistance of hybrid fiber (blended steel and polypropylene fiber with different diameter and length) reinforced concrete at elevated temperature. The compressive, splitting tensile, flexural, plastic shrinkage test were conducted to the evaluate the mechanical properties and the resistance of shrinkage crack. Also, the surface investigation, reduction rate of mass and residual compressive test were performed to evaluate the physical and mechanical properties after 400$^{\circ}C$, 600$^{\circ}C$, 800$^{\circ}C$ and 1,200$^{\circ}C$ exposure. Test results showed that the hybrid fiber reinforced concrete improved the mechanical performance, shrinkage crack and fire resistance. The reduction of performance with a temperature change were high at the temperature of $600\sim800^{\circ}C$.

Risk Perception of Fire Fighters Responsible for Nuclear Power Plants : A Concept Mapping Approach (원자력발전소 관할 소방관의 위험인식 개념도 연구)

  • Choi, HaeYoun;Lee, SongKyu;Kim, MiKyong;Choi, Jong-An
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.141-149
    • /
    • 2018
  • The perception of risk that firefighters have is closely related to their performance and emergency preparedness in nuclear power plant accidents. This study investigated the unique risk perception among firefighters working in nuclear power plants (NPPs) using a concept mapping method. Thirty three firefighters in NPPs participated in this study. Two core axes, "fear and control" and "coping resource", emerged in the firefighters' risk perception. In particular, the risk perception consisted of six clusters: fear of radiation exposure and low controllability; anxiety caused by the lack of control and authority; lack of trust and cooperation; lack of authority and professionals; lack of equipment, manual, and information; and lack of knowledge and training. Catastrophic expectation and a low sense of control caused by the lack of responsive resources were the main factors that increase the risk perception. The theoretical and practical contributions of this study were discussed.