• Title/Summary/Keyword: Exposure doses

Search Result 554, Processing Time 0.027 seconds

A Basic Study on the Radiological Characteristics and Disposal Methods of NORM Wastes (공정부산물의 방사선적 특성과 처분방안에 관한 기본 연구)

  • Jeong, Jongtae;Baik, Min-Hoon;Park, Chung-Kyun;Park, Tae-Jin;Ko, Nak-Youl;Yoon, Ki Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.3
    • /
    • pp.217-233
    • /
    • 2014
  • Securing the radiological safety is a prerequisite for the safe management of the naturally occurring radioactive materials (NORM) which cannot be reused. This becomes a crucial focus of our R&D efforts upon the implementation of the Act on Protective Action Guidelines against Radiation in the Natural Environment. To secure the safety, the establishment of technical bases and procedures for securing radiological safety related to the disposal of NORM is required. Thus, it is necessary to analyze the characteristics, to collect the data, to have the radiological safety assessment methodologies and tools, to investigate disposal methods and facilities, and to study the effects of the input data on the safety for the NORM wastes. Here, we assess the environmental impact of the NORM waste disposal with respect to the major domestic and foreign NORM characteristics. The data associated with major industries are collected/analyzed and the status of disposal facilities and methodologies relevant to the NORM wastes is investigated. We also suggest the conceptual design concept of a landfill disposal facility and the management plan with respect to the major NORM wastes characteristics. The radionuclide pathways are identified for the atmospheric transport and leachate release and the environmental impact assessment methodology for the NORM waste disposal is established using a relevant code. The assessment and analysis on the exposure doses and excessive cancer risks for the NORM waste disposal are performed using the characteristics of the representative domestic NORM wastes including flying ash, phosphor gypsum, and redmud. The results show that the exposure dose and the excessive cancer risks are very low to consider any radiation effects. This study will contribute to development in the areas of the regulatory technology for securing radiological safety relevant to NORM waste disposal and to the implementation technology for the Act.

Comparison of Average Glandular Dose in Screen-Film and Digital Mammography Using Breast Tissue-Equivalent Phantom (유방조직등가 팬텀을 이용한 Screen-Film과 Digital Mammography에서의 평균 유선선량)

  • Shin, Gwi-Soon;Kim, Jung-Min;Kim, You-Hyun;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.13-23
    • /
    • 2007
  • In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate(IP). We measured average glandular doses(AGD) in screen-film mammography(SFM) system with slow screen-film combination, computed mammography(CM) system, indirect digital mammography(IDM) system and direct digital mammography(DDM) system using brest tissue-equivalent phantom(glandularity 30%, 50% and 70%). The results were shown as follows : AGD values for DDM system were highest than those for other systems. Although automatic exposure control(AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter(Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in oder to estimate a patient radiation dose.

  • PDF

Evaluation on Usefulness of Abdomen and Chest Motion Control Device (ABCHES) for the Tumor with a Large Respiratory Motion in Radiotherapy (호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdomen and Chest Motion Control Device (ABCHES)의 유용성 평가)

  • Cho, Yoon-Jin;Jeon, Mi-Jin;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Sook;Im, Jung-Ho;Lee, Ik-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: It is essential to minimize the respiratory-induced motion of involved organs in the Tomotherapy for tumor located in the chest and abdominal region. However, the application of breathing control system to Tomotherapy is limited. This study was aimed to investigate the possible application of the ABCHES system and its efficacy as a means of breathing control in the tomotherapy treatment. Materials and Methods: Five subjects who were treated with a Hi-Art Tomotherapy system for lung, liver, gallbladder and pancreatic tumors. All patients undertook trained on two breathing methodes using an ABCHES, free breathing methode and shallow breathing methode. When the patients could carry out the breathing control, 4D-CT scan was a total of 10 4D tomographic images were acquired. A radiologist resident manually drew the tumor region, including surrounding nomal organs, on each of CT images at the inhalation phase, the exhalation phase and the 40% phase (mid-inhalation) and average CT image. Those CT images were then exported to the Tomotherapy planning station. Data exported from the Tomotherapy planning station was analyzed to quantify characteristics of dose-volume histograms and motion of tumors. Organ motions under free breathing and shallow breathing were examined six directions, respectively. Radiation exposure to the surrounding organs were also measured and compared. Results: Organ motion is in the six directions with more than a 5 mm displacement. A total of 12 Organ motions occurred during free breathing while organ motions decreased to 2 times during shallow breathing under the use of Abches. Based on the quantitative analysis of the dose-volume histograms shallow breathing showed lower resulting values, compared to free breathing, in every measure. That is, treatment volume, the dose of radiation to the tumor and two surrounding normal organs (mean doses), the volume of healthy tissue exposed to radiation were lower at the shallow breathing state. Conclusion: This study proposes that the use of ABCHES is effective for the Tomotherapy treatment as it makes shortness of breathing easy for patients. Respiratory-induced tumor motion is minimized, and radiation exposure to surrounding normal tissues is also reduced as a result.

  • PDF

Accuracy evaluation of treatment plan according to CT scan range in Head and Neck Tomotherapy (두경부 토모테라피 치료 시 CT scan range에 따른 치료계획의 정확성 평가)

  • Kwon, Dong Yeol;Kim, Jin Man;Chae, Moon Ki;Park, Tae Yang;Seo, Sung Gook;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.13-24
    • /
    • 2019
  • Purpose: CT scan range is insufficient for various reasons in head and neck Tomotherapy®. To solve that problem, Re-CT simulation is good because CT scan range affects accurate dose calculations, but there are problems such as increased exposure dose, inconvenience, and a change in treatment schedule. We would like to evaluate the minimum CT scan range required by changing the plan setup parameter of the existing CT scan range. Materials and methods: CT Simulator(Discovery CT590 RT, GE, USA) and In House Head & Neck Phantom are used, CT image was acquired by increasing the image range from 0.25cm to 3.0cm at the end of the target. The target and normal organs were registered in the Head & Neck Phantom and the treatment plan was designed using ACCURAY Precision®. Prescription doses are Daily 2.2Gy, 27 Fxs, Total Dose 59.4Gy. Target is designed to 95%~107% of prescription dose and normal organ dose is designed according to SMC Protocol. Under the same treatment plan conditions, Treatment plans were designed by using five methods(Fixed-1cm, Fixed-2.5cm, Fixed-5cm, Dynamic-2.5cm Dynamic-5cm) and two pitches(0.43, 0.287). The accuracy of dose delivery for each treatment plan was analyzed by using EBT3 film and RIT(Complete Version 6.7, RIT, USA). Results: The accurate treatment plan that satisfying the prescribed dose of Target and the tolerance dose in normal organs(SMC Protocol) require scan range of at least 0.25cm for Fixed-1cm, 0.75cm for Fixed-2.5cm, 1cm for Dynamic-2.5cm, and 1.75cm for Fixed-5cm and Dynamic-5cm. As a result of AnalysisAnalysis by RIT. The accuracy of dose delivery was less than 3% error in the treatment plan that satisfied the SMC Protocol. Conclusion: In case of insufficient CT scan range in head and neck Tomotherapy®, It was possible to make an accurate treatment plan by adjusting the FW among the setup parameter. If the parameter recommended by this author is applied according to CT scan range and is decide whether to re-CT or not, the efficiency of the task and the exposure dose of the patient are reduced.

A Study on Dose Assessment by 18F-FDG injected into Patients (환자에게 주입된 18F-FDG 의한 선량 평가에 대한 연구)

  • Kim, Chang-Ju;Kim, Jang-Oh;Jeong, Geun-Woo;Shin, Ji-Hey;Lee, Ji-Eun;Jeon, Chan-Hee;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.467-475
    • /
    • 2020
  • The purpose of this study is to assess doses to 18F-FDG, a radioactive drug, during PET examinations, to alleviate anxiety about radiation in patients and carers, to minimize the indiscriminate examination progress caused by medical institution personnel and space clearance problems, and health examination. The dose assessment was measured using a thermo-fluorescent dosimeter (TLD) and an electronic personal dosimeter (EPD) at the location of the cervical (hypothyroid), thorax (heart), and lower abdomen (breeding line) which are the three highest tissue areas of the radiation tissue weighting. In addition, spatial dose rates and radioactivity in urine were measured using GM counters and ion boxes. The results are as follows: First, the personal dosimeter TLD was measured 0.0425±0.0277 mSv in the cervical region, 0.0440±0.0386 mSv in the thorax and 0.0485±0.0436 mSv in the lower abdomen, with little difference in the heart dose depending on radiation sensitivity. The EPD was measured at 0.942±0.141 mSv/h immediately after the cervical position, and 0.192±0.031 mSv/h after 120 minutes. Immediately after the thorax position, 0.516±0.085 mSv/h, 120 minutes later 0.128±0.040 mSv/h. Immediately after the lower abdomen position, 0.468±0.091 mSv/h, and after 120 minutes 0.105±0.021 mSv/h were measured. The spatial dose rate at the GM counter was measured immediately at 0.041±0.005 mSv/h, 120 minutes later at 0.014±0.002 mSv/h. The radioactivity in urine using ion chamber was measured at 0.113±0.24 MBq/cc after 60 minutes and 0.063±0.13 MBq/cc after 120 minutes. As a result, 18F-FDG should be administered, dose re-evaluated two hours after the PET test is completed, and caregivers should be avoided. In addition, it is deemed necessary to provide patients and carers with sufficient explanations and expected values of exposure dose to avoid reckless testing. It is hoped that the data tested in this study will help patients and families relieve anxiety about radiation, and that the radiation workers' exposure management system and institutional improvements will contribute to the development of medical radiation.

Preliminary Post-closure Safety Assessment of Disposal Options for Disused Sealed Radioactive Source (폐밀봉선원 처분방식별 폐쇄후 예비안전성평가)

  • Lee, Seunghee;Kim, Juyoul;Kim, Sukhoon
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.301-314
    • /
    • 2016
  • Disused Sealed Radioactive Sources (DSRSs) are stored temporally in the centralized storage facility of Korea Radioactive Waste Agency (KORAD) and planned to be disposed in the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju city. In this study, preliminary post-closure safety assessment was performed for DSRSs in order to draw up an optimum disposal plan. Two types of disposal options were considered, i.e. engineered vault type disposal and rock cavern type disposal which were planned to be constructed and operated respectively in LILW disposal facility in Gyeongju city. Assessment end-point was individual effective dose of critical group and calculated by using GoldSim code. In normal scenario, the maximum dose was estimated to be approximately $1{\times}10^{-7}mSv/yr$ for both disposal options. It meant that both options had sufficient safety margin when compared with regulatory limit (0.1 mSv/yr). Otherwise, in well scenario, the maximum dose exceeded regulatory limit of 1 mSv/yr in engineered vault type disposal and the exposure dose was mainly contributed by $^{226}Ra$, $^{210}Pb$ (daughter nuclide of $^{226}Ra$) and $^{237}Np$ (daughter nuclide of $^{241}Am$). For rock cavern type disposal, even though the peak dose satisfied regulatory limit, the exposure doses by $^{14}C$ and $^{237}Np$ were relatively high above 10% of regulatory limit. Therefore, it is necessary to exclude $^{14}C$, $^{226}Ra$ and $^{241}Am$ for two type of disposal options and additional management such as long-term storage and development of disposal container for those radionuclides should be performed before permanent disposal for conservative safety and security.

Packing effects on the intracavitary radiation therapy of the utaine lervix cancer ($^{192}Ir$source를 이용할 자궁경부암 강내치료시 사용하는 packing의 효과에 대한 고찰)

  • Cho, Jung-Kun;Lee, Du-Hyun;Si, Chang-Kun;Choi, Yoon-Kyung;Kim, Tae-Yoon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.73-77
    • /
    • 2004
  • Purpose of the radio-therapy is maximize the radiation dose to the tumor while minimizing the dose to the critical organ. Carcinoma of the uterine cervix treatment are external irradiation or an interstitial brachtheraphy make use of isotope. Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. Authors make use of the patients data which 192Ir gives medical treatment intrcavity. Intracavitary radiation of the uterine cervix cancer, critical organ take $20\%$ below than exposure dose of A point in the ICRU report. None the less of the advice, Radiation proctitis and radiation cystitis are frequent and problematic early complications in patients treated with radiation for the uterine cervix cancer. In brachytherapy of uterine cervical cancer using a high dose rate remote afterloading system, it is of prime importance to deliver a accurate dose in each fractionated treatment by minimizing the difference between the pre-treatment planned and post-treatment calculated doses. Use of packing to reduce late complications intracavitary radiation of the uterine cervix cancer. Bladder and rectum changes exposure dose rate by radiotherphy make use of packing.

  • PDF

Photoprotection and Anti-inflammatory Effects of Chinese Medical Plants (약용식물추출물의 광보호 효과와 항염증 효과 연구)

  • Jin-Hwa, Kim;Sung-Min, Park;Gwan-Sub, Sim;Bum-Chun , Lee;Hyeong-Bae, Pyo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.227-233
    • /
    • 2004
  • Chronic exposure to solar radiation, particularly ultraviolet (UV) light, causes a variety of adverse reactions on human skin, such as sunburn, photoaging and photocarcinogenesis. Free radicals and reactive oxygen species (ROS) caused by UV exposure or other environmental facts play critical roles in cellular damage. And, repeated-UV irradiation activated the expression of the matrix metalloproteinase (MMP) and induced skin irritation. Therefore, the development of effective and safe photoprotectants that can reduce and improve the skin damage has been required. The purpose of this study was to investigate the photo-protective effect of several chinese medical plants (Juniperus chinensis) on the UV -induced skin cell damages. We tested free radical and superoxide scavenging effect in vitro. Fluorometric assays of the proteolytic activities of MMP-1 (collagenase) were performed using fluorescent collagen substrates. UVA induced MMP-1 synthesis and activity were analyzed by enzyme-linked immunosorbent assay (ELISA) and gelatin-based zymography in skin fibroblasts. We also examined anti-inflammatory effects by the determination test of proinflammatory cytokine, interleukin 6 in HaCaT keratinocytes. Expression of prostaglandin E$_2$ (PGE$_2$) after UVB irradiation was measured by competitive enzyme immunoassay(EIA) using PGE$_2$ monoclonal antibody. In the human skin we tested anti-irritation effect on the SLS-induced damage skin after appling the extract containing emulsion. We found that Juniperus chinensis extract had potent radical scavenging effect by 98% at 100$\mu\textrm{g}$/mL. The extract of Juniperus chinensis showed strong inhibitory effect on MMP-1 activities by 97% at 100 $\mu\textrm{g}$/mL and suppressed the UVA induced expression of MMP-1 by 79% at 25$\mu\textrm{g}$/mL. This extract also showed strong inhibition on MMP-2 activity in UVA irradiated fibroblast by zymography. In the test of proinflammatory cytokines of human keratinocytes Juniperus chinensis extract decreased expression of interleukin 6 about 30%. The amount of PGE$_2$ by HaCaT keratinocytes was significantly increased at the doses of above 10 mJ/$\textrm{cm}^2$ of UVB (p < 0.05). At the concentrations of 3.2-25$\mu\textrm{g}$/mL of this extract, the production of PGE$_2$ by HaCaT keratinocytes (24 h after 10mJ/$\textrm{cm}^2$ UVB irradiation) was significantly inhibited in culture supernatants (p < 0.05). In SLS-induced skin irritation model in vivo, we found to reduce skin erythema and improve barrier recovery after appling Juniperus chinensis extract containing emulsion when compared to irritated non-treated and placebo-treated skin. Our results suggest that Juniperus chinensis extract can be effectively used for the prevention of UV and SLS-induced adverse skin reactions and applied as anti-aging and anti-irritation cosmetics.

Post-Exposure Prophylaxis of Varicella in Family Contact by Oral Acyclovir (가족 내 수두 환자와 접촉 후 경구 Acyclovir의 예방효과)

  • Kim, Sang Hee;Kim, Jong Hyun;Oh, Jin Hee;Hur, Jae Kyun;Kang, Jin Han;Koh, Dae Kyun
    • Pediatric Infection and Vaccine
    • /
    • v.9 no.1
    • /
    • pp.61-66
    • /
    • 2002
  • Purpose : To determine wether varicella can be prevented by administration of oral acyclovir(ACV) during the incubation period of the disease. Methods : Starting 9 days after exposure to the index case in their families, ACV(40 mg/kg/day in four divided doses) was given orally to 20 exposed children for 5 days. Their clinical features was compared with those of 20 control subjects. Antibody titers to VZV were measured in both group 1 week and 4 weeks after finishing the oral ACV administration. Results : The mean age of family members with varicella(51.4 months) were significantly high compared to that of ACV prophylaxis group(28.5 months) and control group(31 months) (P<0.05). Among the 12 children with ACV prophylaxis who completed follow up blood sampling, nine children were diagnosed as VZV infection on the serologic test(75%). Among them six children showed positive VZV IgM on the first blood sample and two children showed serocoversion to positive IgM on the second test after ACV prophylaxis. One child who was negative on both IgM and IgG, showed positive IgG on the second test. The incidence of fever and severity of skin rashes were significantly low in children received oral ACV than in the control group. No or reduced number of maculopapular eruption were observed in the oral ACV group compared to multiple vesicles of the control group. Conclusion : In the present study, we observed that oral ACV prophylaxis to the family contacts is effective in reducing severity of skin lesion. It is likely that oral ACV 9 days after contact prevents or reduces blood dissemination of VZV. Little is known about clinical effect and immunity to the virus in exposed children with no varicella symptom after treatment. We propose the checking up antibody to VZV some period after oral ACV, and considering vaccination to whom with no antibody. But further more studies are needed to practical application of oral ACV for the postexposure prophylaxis of varicella.

  • PDF

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.