• Title/Summary/Keyword: Exposure doses

Search Result 562, Processing Time 0.032 seconds

Cross-Resistance to Toluene and Heat in Micrococus sp. BCNU 121 (Micrococcus sp. BCNU 121균주의 toluene과 열에 대한 교차내성)

  • 주우홍;한수지;최용락;정영기
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.188-192
    • /
    • 2004
  • Toluene tolerance and therrnotolerance in Crampositive organic solvent resistant bacterium Micrococcus sp. BCNU 121 has been studied. Exposure to a sub- lethal temperature or a sub-lethal concentration of toluene conferred protection to subsequent challenges with a killing temperature or a lethal concentration of toluene, respectively. Pretreatment of Micrococcus sp. BCNU 121 with sub-lethal concentrations of toluene induced adaptative protection against heat shock. Moreover, temperature-adaptative cells also showed cross-resistance to lethal doses of toluene. These data suggested a cross-regulation between toluene tolerance and heat shock response.

A SOLUTION TO THE PROBLEM WITH ABSORBED DOSE

  • Braby, Leslie A.
    • Nuclear Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.533-538
    • /
    • 2008
  • In some situations, for example at very low doses, in microbeam irradiation experiments, or around high energy heavy ion tracks, use of the absorbed dose to describe the energy transferred to the irradiated target can be misleading. Since absorbed dose is the expected value of energy per mass it takes into account all of the targets which do not have any energy deposition. In many situations that results in numerical values, in Joules per kg, which are much less than the energy deposited in targets that have been crossed by a charged particle track. This can lead to confusion about the biochemical processes that lead to the consequences of irradiation. There are a few alternative approaches to describing radiation that avoid this potential confusion. Examples of specific situations that can lead to confusion are given. It is concluded that using the particle radiance spectrum and the exposure time, instead of absorbed dose, to describe these irradiations minimizes the potential for confusion about the actual nature of the energy deposition.

Study on the MED of Koreans (한국인의 최소홍반량에 관한 연구)

  • 김진준;박문억
    • Proceedings of the SCSK Conference
    • /
    • 1992.09a
    • /
    • pp.36-45
    • /
    • 1992
  • The dosal sites of 61 Koreans were exposed to increasing UVB doses in the 10mJ/$\textrm{cm}^2$ interval from 10mJ/$\textrm{cm}^2$ to 100mJ/$\textrm{cm}^2$ by solar-simulator, and at the 24hr after UV-B exposure we determined the first MED (Minimal Erythema Dose). For the precise measurements, we peformed the second exposures arround the first MED with 2.5mJ/$\textrm{cm}^2$ interval. The mean MED of all volunteers was 39.6 $\pm$ 15.7mJ/$\textrm{cm}^2$. As the distinction of sex, the means of male and female were 46.9 $\pm$ 18.1mJ/$\textrm{cm}^2$ and 31.5$\pm$8.5mJ/$\textrm{cm}^2$ respectively. According to the classification of skin type by Greiter. F.(1), the percent of skin type I to Ⅵ were 10.9%, 36.4%, 34.6%, 12.7%, 3.6%, and 1.8% respectively.

  • PDF

The Effects on Antioxidants for Improving to Radiation Resistance of LDPE (저밀도 폴리에틸렌의 내방사선성 향상을 위한 산화방지제 첨가효과)

  • Kim, Ki-Yup;Kim, Pyeong-Jong;Lee, Chung;Kim, Jin-Ah;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.457-460
    • /
    • 2004
  • Many of the physical and chemical properties of polymer materials can be altered by high energy radiation. In the present work the exposure to radiation of low density polyethylene(LDPE) included antioxidants was carried out at various doses up to 600kGy at a dose rate of 5kGy/hr in the presence of air at room temperature. The study of the irradiation effects on the material properties has been make by different methods in an integrated way. The experimental data indicate that the decomposition onset temperature(DOT), the crystallinity and the thermoluminescence(TL) with radiation dose. DOT, crystallinity and TL analysis from irradiated PE samples provides useful data for the characterization of radiation-induced oxidation effects on these samples.

  • PDF

Development Characteristics of PMMA fabricated by X-ray Lithography in Various Development Conditions (X-ray 식각된 PMMA의 다양한 현상조건에 따른 현상특성)

  • Kim, Yun-Ho;Park, Joon-Shik;Lee, In-Gyu;Park, Soon-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.284-287
    • /
    • 2004
  • Micro-structures fabricated by X-ray lithography are largely affected by doses, development conditions and other factors. For these reasons, PMMA development rates and its surface profiles under various development conditions were obseued. Development rates were measured in the rage from 1 to 6 $kJ/cm^3$ using the 9C1 white beamline of Pohang light source(PLS). In this experiment, we observed that development rates of stacked PMMA sheet using Si filter were relatively higher than that of not using Si filter. Furthermore, development rates in condition with the acoustic agitation(1 MHz, 3.67 $W/cm^3$) were twice than that in dipping condition with $35^{\circ}C$ developer considering the PMMA sheets-substrate bond strength

  • PDF

Basic Physical Principles and Clinical Applications of Computed Tomography

  • Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.1-17
    • /
    • 2021
  • The evolution of X-ray computed tomography (CT) has been based on the discovery of X-rays, the inception of the Radon transform, and the development of X-ray digital data acquisition systems and computer technology. Unlike conventional X-ray imaging (general radiography), CT reconstructs cross-sectional anatomical images of the internal structures according to X-ray attenuation coefficients (approximate tissue density) for almost every region in the body. This article reviews the essential physical principles and technical aspects of the CT scanner, including several notable evolutions in CT technology that resulted in the emergence of helical, multidetector, cone beam, portable, dual-energy, and phase-contrast CT, in integrated imaging modalities, such as positron-emission-tomography-CT and single-photon-emission-computed-tomography-CT, and in clinical applications, including image acquisition parameters, CT angiography, image adjustment, versatile image visualizations, volumetric/surface rendering on a computer workstation, radiation treatment planning, and target localization in radiotherapy. The understanding of CT characteristics will provide more effective and accurate patient care in the fields of diagnostics and radiotherapy, and can lead to the improvement of image quality and the optimization of exposure doses.

Co-treatment with Origanum Oil and Thyme Oil Vapours Synergistically Limits the Growth of Soil-borne Pathogens Causing Strawberry Diseases

  • Jong Hyup, Park;Min Geun, Song;Sang Woo, Lee;Sung Hwan, Choi;Jeum Kyu, Hong
    • The Plant Pathology Journal
    • /
    • v.38 no.6
    • /
    • pp.673-678
    • /
    • 2022
  • Vapours from origanum oil (O) and thyme oil (T) were applied to the four soil-borne strawberry pathogens Fusarium oxysporum f. sp. fragariae, Colletotrichum fructicola, Lasiodiplodia theobromae, and Phytophthora cactorum, causing Fusarium wilt, anthracnose, dieback, and Phytophthora rot, respectively. Increasing T vapour doses in the presence of O vapour strongly inhibited mycelial growths of the four pathogens and vice versa. When mycelia of F. oxysporum f. sp. fragariae and P. cactorum exposed to the combined O + T vapours were transferred to the fresh media, mycelial growth was restored, indicating fungistasis by vapours. However, the mycelial growth of C. fructicola and L. theobromae exposed to the combined O + T vapours have been slightly retarded in the fresh media. Prolonged exposure of strawberry pathogens to O + T vapours in soil environments may be suggested as an alternative method for eco-friendly disease management.

The Study for Optimal Exposure Condition of Chest Examination of Digital Radiography System (디지털 방사선 촬영장치의 흉부촬영 최적 조사조건에 관한 연구)

  • Park, Ji-Koon;Jung, Bong-Jae;Park, Hyong-Hu;Noh, Si-Cheol;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.109-115
    • /
    • 2016
  • Despite of increasing the use of the digital imaging device in the radiology area, the setting on the optimal irradiation conditions are insufficient. In this study, the exposure dose and image quality by exposure condition of digital radiography device were compared. The exposure doses were obtained by adjusting the exposure condition as 5 steps respectively based on the exposure conditions that are currently used of CR and DR radiography devices. The acquired image has been assessed by 20 medical image professors using the assessment method of the Japanese Society for Tuberculosis Prevent. As a result, in the case of the CR system, the better image quality was obtained in the condition of 120 kVp and 1.5 mAs~2.4 mAs (quality score 91~95.5 points) than standard exposure condition(110 kVp, 3.2 mAs, 86 points). And exposure dose was evaluated as low with $61.3{\sim}98.4{\mu}Gy$ than standard condition($105.11{\mu}Gy$). In DR system, however, the image quality score was higher as 97~98.6 points in the lower tube voltage range (112 kVp, 2.4~3.2 mAs) condition than the standard exposure condition (125 kVp, 3.2 mAs, 91 points). In addition, the exposure dose was $61.5-77.2{\mu}Gy$ lower than standard condition($93{\mu}Gy$). In addition, the exposure dose was low as $61.5-77.2{\mu}Gy$ than standard condition($93{\mu}Gy$). With the results of this study, we confirmed that it is possible to reduce the patient exposure dose with the same image quality by adjusting the optimal exposure condition of digital device.

Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan (전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석)

  • 사정호;서태석;최보영;정규회
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.59-71
    • /
    • 2000
  • It is possible to obtain a fast CT scan during breath holding with spiral technique. But the risk of radiation is increased due to detailed and repeated scans. However, the limitation of X-ray doses is not fully specified on CT, yet. Therefore, the purpose of the present study is to define the limitation of X-ray doses on CT The CT unit was somatom plus 4. Alderson Rando phantom, Solenoid water phantom, TLD, and reader were used. For determining adequate position and size of organs, the measurement of distance(${\pm}$2mm) from the midline of vertebral body was performed in 40 women(20~40 years). On the brain scan for 8:8(8mm slice thickness, 8mm/sec movement velocity of the table) and 10:10(10mm slice thickness, 10mm/sec movement velocity of the table) methods, the absorption doses of exposed area of the 10:10 were slightly higher than those of 8:8. The doses of unexposed uterus were negligible on the brain scan for both 8:8 and 10:10. On the chest scan for 8:8, 8:10(8mm slice thickness, 10mm/sec movement velocity of the table), 10:10, 10:12(10mm slice thickness, 12mm/sec movement velocity of the table) and 10:15(10mm slice thickness, 15mm/sec movement velocity of the table) methods, 8:8 method of the absorption doses of exposure area was the most highest and 10:15 method was the most lowest. The absorption doses of 8:10 method was relatively lower than those of the other methods. In conclusion, the 8:10 method is the most suitable to give a low radiation burden to patient without distorting image quality.

  • PDF

A Field Test Assessment on the Extremity Doses of Highly-Exposed Radiation Workers During Maintenance Periods at Nuclear Power Plants in Korea (원전 계획예방정비기간 고피폭 접촉작업에서 방사선작업종사자의 말단선량 평가 현장시험)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.57-62
    • /
    • 2010
  • Maintenance on the water chamber of steam generator, the change of pressurizer heater, the removal of pressure tube feeder, and so on during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, field tests on extremity dose assessment of radiation workers for contact works with high radiation exposure were conducted during the maintenance periods in Korean pressurized water reactors (PWRs) and pressurized heavy water reactors (PHWRs). In this field test, radiation workers were required to wear additional TLDs on the back and wrist, and an extremity dosimeter on fingers including a main TLD on the chest, while performing maintenance. As a result, it was found that the equivalent dose for fingers was distributed in the fixed range of deep dose and the equivalent dose for wrists.