• 제목/요약/키워드: Exposure doses

검색결과 554건 처리시간 0.033초

Determination of indoor doses and excess lifetime cancer risks caused by building materials containing natural radionuclides in Malaysia

  • Abdullahi, Shittu;Ismail, Aznan Fazli;Samat, Supian
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.325-336
    • /
    • 2019
  • The activity concentrations of $^{226}Ra$, $^{232}Th$, and $^{40}K$ from 102 building materials samples were determined using a high-purity germanium (HPGe) detector. The activity concentrations were evaluated for possible radiological hazards to the human health. The excess lifetime cancer risks (ELCR) were also estimated, and the average values were recorded as $0.42{\pm}0.24{\times}10^{-3}$, $3.22{\pm}1.83{\times}10^{-3}$, and $3.65{\pm}1.85{\times}10^{-3}$ for outdoor, indoor, and total ELCR respectively. The activity concentrations were further subjected to RESRAD-BUILD computer code to evaluate the long-term radiation exposure to a dweller. The indoor doses were assessed from zero up to 70 years. The simulation results were $92{\pm}59$, $689{\pm}566$, and $782{\pm}569{\mu}Sv\;y^{-1}$ for indoor external, internal, and total effective dose equivalent (TEDE) respectively. The results reported were all below the recommended maximum values. Therefore, the radiological hazards attributed to building materials under study are negligible.

소아 핵의학 검사 시 사용되는 방사성의약품의 양 산출 기준 조사 (A Research of Standards for Radiopharmaceutical Doses in Pediatric Nuclear Medicine)

  • 도용호;김계환;이홍재;김진의;김현주
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.47-50
    • /
    • 2009
  • 목적 : 현재 소아 핵의학 검사 시 사용되는 방사성의약품 선량 산출 기준은 확립되어있지 않다. 그리하여 병원들은 몸무게 기준 산출 공식(mCi/kg), 체표면적 시준 산출 공식(mCi/$m^2$) 또는 미국, 유럽, IAEA의 선량 산출 공식 등 다양한 선량 기준을 따르고 있다. 그러나 이러한 선량 산출 공식들은 1세 이하의 영아나 50 kg 이상의 어린이들에 대한 정확한 선량을 산출하는데 어려움을 격고 있으므로 국내의 선량기준을 조사하여 이를 미국, 유럽, IAEA의 기준에 비교하고 각 기준의 문제점을 비교여 적절한 선량 기준의 확립을 권고 하고자 본 논문을 시행하게 되었다. 실험재료 및 방법: 객관적인 정보의 획득을 위하여 소아핵의학 검사를 가장 많이 시행하는 국내 4개 대학병원을 선정하여 설문을 실시하였으며 이에 대한 답변을 기초로 각 몸무게 당 사용되는 방사성의약품의 양을 multiplier로 변환하여 이를 미국, 유럽, IAEA의 multiplier와 비교하였다. 결과: 국민 대부분의 병원들은 몸무게 기준 산출 공식을 이용하여 소아 핵의학 검사 시 사용되는 방사성의약품의 양을 산출하고 있었으며 1세 이하의 영아와 50 kg 이상 어린이에 대한 과소량, 과잉량 투여 문제는 고려되고 있지 않은 것으로 나타났다. 결론 및 고찰: 본 논문을 통하여 대한민국의 기준을 비롯한 여러 기준들은 소아 핵의학 검사 시 적정한 선량 산출에 어려움을 겪고 있는 것으로 나타났다. 그러므로 성공적인 검사가 가능한 최소의 선량으로 방사선 피폭을 최소화 하는 세계적으로 인정된 선량 체계를 확립하여야 할 것이다. 또한 보다 우수한 영상 재구성 프로그램의 개발을 통하여 검사 시간을 단축함과 동시에 보다 나은 영상 구현을 실현하여야 할 것이다.

  • PDF

핵의학 체내검사 업무 단계 별 피폭선량 측정 및 분석을 통한 피폭선량 감소 방안 (The Plan of Dose Reduction by Measuring and Evaluating Occupationally Exposed Dose in vivo Tests of Nuclear Medicine)

  • 길상형;임영현;박광열;조경남;김정훈;오지은;이상엽;이수정;전지탁;정의호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.26-32
    • /
    • 2010
  • 핵의학 체내검사 업무 단계 별 작업종사자의 피폭선량을 측정 및 분석하여 환자 검사 및 업무효율 저하를 발생시키지 않는 범위 내에서 종사자의 피폭선량을 최소로 감소할 수 있는 방법을 알아보고자 하였다. 방사성동위원소를 이용한 핵의학 체내검사 업무는 방사성 동위원소 분배, 방사성동위원소 주사($^{99m}Tc$, $^{18}F$-FDG), 환자 안내 및 검사로 이루어진다. RadEye-G10 측정기기(Thermo SCIENTIFIC)를 이용하여 각 업무 단계 별 피폭선량을 측정 및 분석 하였다. 방사성동위원소를 환자에게 주사하는 과정에서 많은 피폭이 발생하므로 작업종사자의 피폭선량을 최소로 줄일 수 있도록 외부피폭 방어에 대한 교육과 방사성동위원소 주사 시 보호구를 착용하도록 하였으며 주사 전 검사에 대한 설명 및 주의사항을 교육하여 주사 후 환자와의 대면시간을 단축하여 피폭선량을 줄이도록 하였다. 방사성동위원소 주사 시 보호구 착용 유무에 따른 피폭선량과 주사 전 검사에 대한 설명 및 주의사항 교육 유무에 따른 피폭선량을 측정하였다. 총 피폭선량은 icrosoft office Excel 2007을 이용하여 그래프로 나타내었으며 피폭선량의 차이는 SPSS program 12.0을 이용하여 wilcoxon signed ranks test로 분석 하였다. 이 때 p값이 0.01 이하인 경우 통계적으로 유의 하다고 판단하였다. $^{99m}Tc$-DPD 20 mCi를 보호구를 착용하고 주사 시 피폭되는 선량은 보호구를 착용하지 않고 주사 시 피폭되는 선량보다 88% 감소하였으며 통계적으로 유의한 차이가 있었다 (p<0.01). $^{18}F$-FDG 10 mCi를 보호구를 착용하고 주사 시 피폭되는 선량은 보호구를 착용하지 않고 주사 시 피폭되는 선량보다 26% 감소하였으나 통계적으로 유의한 차이는 없었다(p>0.01). $^{99m}Tc$-DPD 20 mCi를 주사 전 검사에 대한 설명 및 주의사항 교육 시 피폭되는 선량은 주사 후 검사에 대한 설명 및 주의사항 교육 시 피폭되는 선량보다 63% 감소하였으며 통계적으로 유의한 차이가 있었다(p<0.01). $^{18}F$-FDG 10 mCi를 주사 전 검사에 대한 설명 및 주의사항 교육 시 피폭 되는 선량은 주사 후 검사에 대한 설명 및 주의사항 교육 시 피폭되는 선량보다 52% 감소하였으며 통계적으로 유의한 차이가 있었다(p<0.01). 방사성동위원소 $^{99m}Tc$을 이용하는 검사에서는 보호구 착용이 피폭선량을 줄이는데 더 효과적이고 $^{18}F$-FDG를 이용하는 검사에서는 주사 후 환자와의 대면시간을 단축하는 것이 피폭선량을 줄이는데 더 효과적이다. 그러므로 이러한 방사성동위원소의 특성에 따라 차폐 방안을 모색한다면 더욱 더 효과적이고 적극적인 방사선 차폐가 될 것으로 사료된다.

  • PDF

방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가 (Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid)

  • 송요성;이정원;이호영;김석기;강건욱;국명철;박원서;이건국;홍은경;이은숙
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권4호
    • /
    • pp.309-316
    • /
    • 2007
  • 감시 림프절 생검은 유방암 수술에서 림프절 전이 상태를 알기 위한 표준 시술이다. 환자는 방사성 콜로이드를 주사 받은 후 수술을 받게 된다. 이 과정에서 검사를 하는 핵의학과, 수술장, 유방암 검체를 다루는 병리과의 관계자는 미량이나마 환자와 검체에 의해서 방사선 피폭을 받을 수 있다. 이 연구의 목적은 감시 림프절 생검 과정, 특히 병리처리 과정에서 받는 방사선피폭을 정량하여 그 안전성을 확인하고 병리 시설과 폐기물에 대해서도 방사선 관련 안전성을 확인하는 것이다. 대상 및 방법 : 감시림프절 생검은 방사성 콜로이드를 이용하여 일반적인 임상적 방법으로 시행되었다. 병리기사, 핵의학 기사 및 핵의학 의사의 피폭량을 열형광선량계를 이용하여 1달간 측정하였다. 또한 작업과정중의 잔존 방사능량, 흡수선량, 작업시간, 작업거리, 조직폐기물 및 병리검사실의 공간선량을 측정하였다. 결과 전신 및 손의 피폭량은 병리기사에서 각각 0.21 및 0.85 uSv/study이었고 핵의학과 의사 및 핵의학과 기사의 전신피폭량은 각각 0.2 및 2.3 uSv/study 이었다. 일반인 기준(1000 uSv/year)으로 병리기사는 년간 약 1100건 감시림프절 관련 검체 처리를 할 수 있었다. 각 과정의 잔존방사성 및 피폭거리, 시간으로 측정한 피폭량은 수술의사는 전신/손의 피폭량이 건당 2.47/22.4 uSv 이었고 수술장간호사는 건당 0.22/0 uSv 이었다. 병리실의 공간선량률은 0.02-0.03 mR/hr로 방사성 관리구역의 설정 기준에 도달하지 않았다. 폐기되는 검체 조직의 방사능은 거의 측정되지 않아 100 Bq/g에 훨씬 미치지 않았다. 결론: 방사성동위원소를 이용한 감시림프절 검사에 관계된 병리처리과정은 방사선안전측면에서 일반적으로 안전하며 별도의 안전관리나 시설 없이 이루어 질 수 있다.

Liver dose reduction by deep inspiration breath hold technique in right-sided breast irradiation

  • Haji, Gunel;Nabizade, Ulviye;Kazimov, Kamal;Guliyeva, Naile;Isayev, Isa
    • Radiation Oncology Journal
    • /
    • 제37권4호
    • /
    • pp.254-258
    • /
    • 2019
  • Purpose: Deep inspiration breath hold (DIBH) is a well-established technique that enables efficient cardiac sparing in patients with left-sided breast cancer. The aim of the current study was to determine if DIBH is effective for reducing radiation exposure of of liver and other organs at risk in right breast radiotherapy (RT). Materials and Methods: Twenty patients with right-sided breast cancer were enrolled in this study. Three-dimensional conformal RT plans were generated for each patient, with two different computed tomography scans of free breathing (FB) and DIBH. Nodes were contoured according to the Radiation Therapy Oncology Group contouring guidelines. Dose-volume histograms for the target volume coverage and organs at risk were evaluated and analyzed. Results: DIBH plans showed significant reduction in mean liver dose (5.59 ± 2.07 Gy vs. 2.54 ± 1.40 Gy; p = 0.0003), V20Gy (148.38 ± 73.05 vs. 64.19 ± 51.07 mL; p = 0.0003) and V10Gy (195.34 ± 93.57 vs. 89.81 ± 57.28 mL; p = 0.0003) volumes compared with FB plans. Right lung doses were also significantly reduced in DIBH plans. Heart and left lung doses showed small but statistically significant improvement with application of the DIBH technique. Conclusion: We report that the use of DIBH for right-sided breast cancer significantly reduces the radiation doses to the liver, lungs, and heart.

Comparison of Three Dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Low Radiation Exposure of Normal Tissue in Patients with Prostate Cancer

  • Cakir, Aydin;Akgun, Zuleyha;Fayda, Merdan;Agaoglu, Fulya
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3365-3370
    • /
    • 2015
  • Radiotherapy has an important role in the treatment of prostate cancer. Three-dimensional conformal radiation therapy (3D-CRT), intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) techniques are all applied for this purpose. However, the risk of secondary radiation-induced bladder cancer is significantly elevated in irradiated patients compared surgery-only or watchful waiting groups. There are also reports of risk of secondary cancer with low doses to normal tissues. This study was designed to compare received volumes of low doses among 3D-CRT, IMRT and VMAT techniques for prostate patients. Ten prostate cancer patients were selected retrospectively for this planning study. Treatment plans were generated using 3D-CRT, IMRT and VMAT techniques. Conformity index (CI), homogenity index (HI), receiving 5 Gy of the volume (V5%), receiving 2 Gy of the volume (V2%), receiving 1 Gy of the volume (V1%) and monitor units (MUs) were compared. This study confirms that VMAT has slightly better CI while thev olume of low doses was higher. VMAT had lower MUs than IMRT. 3D-CRT had the lowest MU, CI and HI. If target coverage and normal tissue sparing are comparable between different treatment techniques, the risk of second malignancy should be a important factor in the selection of treatment.

Dermal Penetration Rate and Pharmacokinetics of the Insecticide Methidathion in Sprague-Dawley Rats

  • Sung, Ha-Jung;Kim, Jeong-Han
    • Toxicological Research
    • /
    • 제17권4호
    • /
    • pp.317-323
    • /
    • 2001
  • The skin penetration rate of methidathion in vitro and pharmacokinetics of methidathion in vivo were studied with male Sprague-Dawley rats by dermal treatment. The in vitro skin penetration rates for Sprague-Dawley rats of methidathion technical (50 mg, 100 ${mu}ell$) and emulsifable concentrate (EC,40mg, 100${mu}ell$) were determined as 18.4 $\mu\textrm{g}$/c $m^2$/h (RSD : 6.5) and 18.5 $\mu\textrm{g}$/c $m^2$/h (RSD : 3.2), respectively. Dose-related systemic exposure (AUC) was observed in rats after dermal treatment. The corresponding AUC, $T_{max}$, $C_{max}$, and $T_{1}$2/ of methidathion in plasma were 1.5$\mu\textrm{g}$.hr/ml, 6 h, 0.10 $\mu\textrm{g}$/ml, and 16 h, for 116mg/kg doses, 3.2 $\mu\textrm{g}$. hr/ml, 8 h, 0.12 $\mu\textrm{g}$/ml, and 23 h, for 232 mg/kg doses and 10 $\mu\textrm{g}$. hr/ml, 12 h, 0.32 $\mu\textrm{g}$/ml, and 20 h, for 1,160 mg/kg doses respectively. The urinary excretion of methidathion, estimated wing an equation derived from the in vitro skin penetration study was 0.24~0.35% of the absorbed dose. The concentration of methidathion in kidney was higher than that in liver. Dose-dependent absorption and excretion of methidathion without saturation was observed under in vivo experimental condition.n.n.

  • PDF

Secondary Neutron Dose in Carbon-ion Radiotherapy: Investigations in QST-NIRS

  • Yonai, Shunsuke;Matsumoto, Shinnosuke
    • Journal of Radiation Protection and Research
    • /
    • 제46권2호
    • /
    • pp.39-47
    • /
    • 2021
  • Background: The National Institutes for Quantum and Radiological Science and Technology-National Institute of Radiological Sciences (QST-NIRS) has continuously investigated the undesired radiation exposure in ion beam radiotherapy mainly in carbon-ion radiotherapy (CIRT). This review introduces our investigations on the secondary neutron dose in CIRT with the broad and scanning beam methods. Materials and Methods: The neutron ambient dose equivalents in CIRT are evaluated based on rem meter (WENDI-II) measurements. The out-of-field organ doses assuming prostate cancer and pediatric brain tumor treatments are also evaluated through the Monte Carlo simulation. This evaluation of the out-of-field dose includes contributions from secondary neutrons and secondary charged particles. Results and Discussion: The measurements of the neutron ambient dose equivalents at a 90#x00B0; angle to the beam axis in CIRT with the broad beam method show that the neutron dose per treatment dose in CIRT is lower than that in proton radiotherapy (PRT). For the scanning beam with the energy scanning technique, the neutron dose per treatment dose in CIRT is lower than that in PRT. Moreover, the out-of-field organ doses in CIRT decreased with distance to the target and are less than the lower bound in intensity-modulated radiotherapy (IMRT) shown in AAPM TG-158 (American Association of Physicists in Medicine Task Group). Conclusion: The evaluation of the out-of-field doses is important from the viewpoint of secondary cancer risk after radiotherapy. Secondary neutrons are the major source in CIRT, especially in the distant area from the target volume. However, the dose level in CIRT is similar or lower than that in PRT and IMRT, even if the contributions from all radiation species are included in the evaluation.

소아 5세 표준촬영 가이드라인과 임상 촬영조건의 입사표면선량과 주요 장기흡수선량 비교 (Comparison of ESD and Major Organ Absorbed Doses of 5-Year-Old Standard Guidelines and Clinical Exposure Conditions)

  • 강아름;이인자;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.355-361
    • /
    • 2017
  • 소아는 성인보다 장기의 방사선에 대한 감수성이 크고 성장 중이기 때문에 더 민감하다. 피폭으로 인한 부작용을 겪는 기대수명이 길기 때문에 피폭선량의 관리가 어른의 경우보다 중요하게 다뤄진다. 본 연구는 10세 팬텀을 사용하여 현재 우리나라에 권고되어 있는 5세 소아의 촬영기준과 입사표면선량의 적합성을 확인하고 추가적으로 제시된 촬영기준으로 장기흡수선량을 측정해보았다. 임상에서 사용 중인 5세와 10세의 촬영조건과 장기흡수선량, 입사표면선량을 비교하였다. 임상 5세 촬영조건이 권고촬영조건보다 약간 높으며 임상 10세 촬영조건은 많이 높게 나타났다. 또한 권고 촬영조건으로 ESD를 측정한 결과 임상 촬영조건의 ESD가 43% 높게 나타났으며 10세의 ESD는 5세의 권고 촬영조건의 ESD 보다 126% 증가를 나타냈다. 5세의 권고된 ESD와 임상 촬영조건에 의한 ESD를 비교한 결과 31.6%의 차이를 나타냈다. 5세의 권고 촬영조건과 임상 촬영조건에 의한 장기흡수선량은 큰 차이는 없으나 흉부와 골반검사에서는 차이가 컸다. 그러나 10세의 임상 촬영조건에 의한 장기흡수선량을 비교하면 월등한 차이가 있었음을 알 수 있었다. 따라서 소아의 권고 선량에 대한 더욱 세분화된 기준안이 연구되어야 할 것으로 사료된다.

Low Dose Exposure to Di-2-Ethylhexylphthalate in Juvenile Rats Alters the Expression of Genes Related with Thyroid Hormone Regulation

  • Kim, Minjeong;Jeong, Ji Seong;Kim, Hyunji;Hwang, Seungwoo;Park, Il-Hyun;Lee, Byung-Chul;Yoon, Sung Il;Jee, Sun Ha;Nam, Ki Taek;Lim, Kyung-Min
    • Biomolecules & Therapeutics
    • /
    • 제26권5호
    • /
    • pp.512-519
    • /
    • 2018
  • Phthalates widely used in the manufacture of plastics have deeply penetrated into our everyday lives. Recently, a concern over the toxicity of phthalates on thyroid, has been raised but in most of cases, the doses employed were unrealistically high. To investigate the effects of phthalates on thyroid, we investigated the effects of the repeated oral exposure to low to high doses (0.3, 3, 30 and 150 mg/kg) di-2-ethylhexylphthalate (DEHP) from weaning to maturity for 90 days in juvenile rats on the thyroid. The histological examination revealed that DEHP significantly induced hyperplasia in the thyroid from the doses of 30 mg/kg, which was confirmed with Ki67 staining. In line with this finding, increased mRNA expression of thyrotropin releasing hormone (Trh) was observed in the thyroid of female at 0.3 mg/kg and 150 mg/kg as determined by RNAseq analysis. Moreover, significantly increased expression of parathyroid hormone (Pth) in the female at 0.3 mg/kg, and thyroglobulin (Tg) and thyroid hormone responsive (Thrsp) in the male at 0.3 mg/kg were noted in the blood, of which changes were substantially attenuated at 150 m/kg, alluding the meaningful effects of low dose DEHP on the thyroid hormone regulation. Urinary excretion of mono-2-ethylhexyl-phthalate (MEHP), a major metabolite of DEHP was determined to be 4.10 and 12.26 ppb in male, 6.65 and 324 ppb in female at 0.3 and 30 mg/kg DEHP, respectively, which fell within reported human urine levels. Collectively, these results suggest a potential adverse effects of low dose phthalates on the thyroid.