• Title/Summary/Keyword: Exposure Rates

Search Result 682, Processing Time 0.027 seconds

Association between Antacid Exposure and Risk of Interstitial Lung Diseases

  • Soohyun Bae;Gjustina Loloci;Dong Yoon Lee;Hye Jin Jang;Jihyeon Jeong;Won-Il Choi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.2
    • /
    • pp.185-193
    • /
    • 2024
  • Background: The mechanisms leading to lung fibrosis are still under investigation. This study aimed to demonstrate whether antacids could prevent the development of interstitial lung disease (ILD). Methods: This population-based longitudinal cohort study was conducted between January 2006 and December 2010 in South Korea. Eligible subjects were ≥40 years of age, exposed to proton pump inhibitors (PPI)±histamine-2 receptor antagonists (H-2 blockers) or H-2 blockers only, and had no history of ILD between 2004 and 2005. Exposure to antacids was defined as the administration of either PPI or H-2 receptor antagonists for >14 days, whereas underexposure was defined as antacid treatment administered for less than 14 days. Newly developed ILDs, including idiopathic pulmonary fibrosis (IPF), were counted during the 5-year observation period. The association between antacid exposure and ILD development was evaluated using adjusted Cox regression models with variables, such as age, sex, smoking history, and comorbidities. Results: The incidence rates of ILD with/without antacid use were 43.2 and 33.8/100,000 person-years, respectively and those of IPF were 14.9 and 22.9/100,000 person-years, respectively. In multivariable analysis, exposure to antacid before the diagnosis of ILD was independently associated with a reduced development of ILD (hazard ratio [HR], 0.57; 95% confidence interval [CI], 0.45 to 0.71; p<0.001), while antacid exposure was not associated with development of IPF (HR, 0.88; 95% CI, 0.72 to 1.09; p=0.06). Conclusion: Antacid exposure may be independently associated with a decreased risk of ILD development.

Fluoroscopic Radiation Exposure during Percutaneous Kyphoplasty

  • Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • Objective: The author measured levels of fluoroscopic radiation exposure to the surgeon's body based on the different beam directions during kyphoplasty. Methods: This is an observational study. A series of 84 patients (96 vertebral bodies) were treated with kyphoplasty over one year. The patients were divided into four groups based on the horizontal and vertical directions of the X-Ray beams. We measured radiation exposure with the seven dosimetry badges which were worn by the surgeon in each group (total of 28 badges). Twenty-four procedures were measured in each group. Cumulative dose and dose rates were compared between groups. Results: Fluoroscopic radiation is received by the operator in real-time for approximately 50% (half) of the operation time. Thyroid protectors and lead aprons can block radiation almost completely. The largest dose was received in the chest irrespective of beam directions. The lowest level of radiation were received when X-ray tube was away from the surgeon and beneath the bed (dose rate of head, neck, chest, abdomen and knee: 0.2986, 0.2828, 0.9711, 0.8977, 0.8168 mSv, respectively). The radiation differences between each group were approximately 2.7-10 folds. Conclusion: When fluoroscopic guided-KP is performed, the X-Ray tube should be positioned on the opposite side of the operator and below the table, otherwise the received radiation to the surgeon's body would be 2.7-10 times higher than such condition.

Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray (엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성)

  • Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

A Study on exposure-Worker to Formaldehyde in the Endoscopy Unit of Hospitals (일부 종합병원 내시경실 근무자의 포름알데히드 노출에 관한 연구)

  • Kim, Jeong Hun;Kim, Dae-Jong;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.195-201
    • /
    • 2009
  • To identify relationship between the airborne concentrations of formaldehyde and the causal factors in the endoscope unit of hospitals, a total of 48 workers selected from 4 hospitals (3 university hospitals and 1 national hospital) were investigated. Airborne formaldehyde samples were collected using passive samplers and subsequently analyzed by HPLC according to the OSHA method 1007. The geometric mean(GM) of airborne formaldehyde concentrations was 0.056 ppm (range: 0.003~0.923 ppm). The rates of exceeding exposure limits of OSHA PEL-TWA and NIOSH REL-TWA were 4.2 % and 83.3%, respectively. The STEL GM concentration was 1.428 ppm(range: 0.103~14.773 ppm). Ventilation condition (p=0.001) and temperature (p=0.017) were statistically significant causal factors for the airborne exposure concentration of formaldehyde in the endoscope unit of hospitals. In conclusion, the workers in the endoscope unit of hospitals were highly exposed to formaldehyde, and adequate controls such as appropriate management of ventilation and temperature are recommended to reduce over exposure to formaldehyde.

Feasibility Study of UV-Disinfection for Water Reuse of Effluent from Wastewater Treatment Plant (용수재이용을 위한 하수처리 유출수의 UV 소독 효율 연구)

  • 윤춘경;정광욱;함종화;전지홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.126-137
    • /
    • 2003
  • The feasibility study of UV-disinfection system was performed for disinfection of effluent from wastewater treatment plant. Three low-pressure UV lamps of 17, 25, and 41 W were examined with various flow rates. Low-pressure UV lamps of 17W were examined with various turbidity, DOM (dissolved organic matter), and SS (suspended solid). The pilot plant was a flow-through type UV-disinfection system, and the range of exposure time varied from 5 to 40 seconds, turbidity from 0 to 40 NTU, DOM from 0 to 30 mg/L, and SS from 10 to 40 mg/L. The 41W lamp demonstrated complete disinfection showing no survival ratio in all the experimental conditions, and generally 17W and 25W lamps also showed high removal ratio over 97%. For the same UV dose (UV intensity times exposure time), high intensity-short exposure conditions showed better disinfection efficiency than low intensity-long exposure conditions. While the effects of turbidity and DOM were not apparent, the effects of SS was significant on the disinfection efficiency which indicates that SS control before UV-disinfection appears to be necessary to increase removal efficiency. Considering characteristics of effluent from existing wastewater treatment plants, cost-effectiveness, stable performance, and minimum maintenance, the flow-through type UV-disinfection system with high intensity and low-pressure lamps was thought to be a competitive disinfection system for wastewater reclamation.

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

Effect of $TO_3$ and $NO_2$ on Net Photosynthesis, Transpiration and Accumulation of Nitrite in Sunflower Leaves

  • Park, Shin-Young;Lee, Sang-Chul
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.2
    • /
    • pp.121-129
    • /
    • 1999
  • Photosynthesis and transpiration rates were simultaneously measured in attached sunflower leaves(Helianthus annuusL. cv. Russian Mammoth) during exposure to $NO_2$ and $O_3$ to determine the effect of mixed gan on photosynthesis and the stomatal aperture. The application of $O_3$ alone reduced both the net photosynthetic and transpiration rates. An analysis of the $CO_2$ diffusive resistances indicated that the main cause affecting photosynthesis reduction during $O_3$ exposure was not the internal gas phase of the leaf $(rCO_2^{liq})$ but rather the liquid phase or mesophyll diffusive resistance $(rCO_2^{liq})$, suggesting that there is a very concomitant relation between photosynthetic reduction and $rCO_2^{liq}$. The application of NO2 alone caused a marked reduction of the net photosynthesis yet no significant reduction of transpiration, indicating that NO2 affects the $CO_2$ fixation processes with no inluence on the stomatal aperture. A greter reduction in the photosynthesis of sunflower plants was caused by the application of $NO_2$ alone as compared to a combination of $NO_2$ and $O_3$. $NO_2$ alone reduced the photosynthetic rate by 90%, whereas a mixture of NO2 and O3 reduced it by 50%.

  • PDF

Development of Moving Alternating Magnetic Filter Using Permanent Magnet for Removal of Radioactive Corrosion Product from Nuclear Power Plant

  • M. C. Song;Kim, S. I.;Lee, K. J.
    • Nuclear Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.494-501
    • /
    • 2002
  • Radioactive Corrosion Products (CRUD) which are generated by the neutron activation of general corrosion products at the nuclear power plant are the major source of occupational radiation exposure. Most of the CRUD has a characteristic of showing strong ferrimagnetisms. Along with the new development and production of permanent magnet (rare earth magnet) which generates much stronger magnetic field than the conventional magnet, new type of magnetic filter that can separate CRUD efficiently and eventually reduce radiation exposure of personnel at nuclear power plant is suggested. This separator consists of inner and outer magnet assemblies, coolant channel and container surrounding the outer magnet assembly. The rotational motion of the inner and outer permanent magnet assemblies surrounding the coolant channel by driving motor system produces moving alternating magnetic fields in the coolant channel. The CRUD can be separated from the coolant by the moving alternating magnetic field. This study describes the results of preliminary experiment performed with the different flow rates of coolant and rotation velocities of magnet assemblies. This new magnetic filter shows better performance results of filtering the magnetite at coolant (water). How rates, rotating velocities of magnet assemblies and particle sizes turn out to be very important design parameters.

Serial Changes in the Rate of Respiratory Metabolism of Olive Flounder, Paralichthys olivaceus Exposed to Intermittent Chlorination of Chlorine Dioxide ($CIO_2$) (이산화염소 (CIO2)의 간헐적 처리에 따른 넙치, Paralichthys olivaceus 호흡대사율의 경시적 변화)

  • Kim, Heung-Yun
    • Journal of fish pathology
    • /
    • v.16 no.2
    • /
    • pp.91-102
    • /
    • 2003
  • The present study was investigated the effects of chlorine dioxide ($CIO_2$) on the rcspimtory metabolism of olive flounder (Parolichlhys olivaceus) imtermittently exposed to seawater chlorinated by $CIO_2$:. Oxygen consumption of flounder before and after once or twice $CIO_2$-treatment with 12 hr- or/and 24 hr-interval were serially measured with automatic intenniteent-flow respirometer system (AIRS). The oxygen consumption rates of flowKier exposed to 0.10 and 0.20 ppm$CIO_2$, were not different from the control fish prior to the once or twice chlorinations . On the other hand, the respiratory metabolic rates of flounder exposed to 0.30 ppm$CIO_2$ were significantly increased 15% and 22 - 23% after the once and twice chlorinations compared to the control fish. respectively. The flounder exposed In 0.40 and 0.50 ppm$CIO_2$: died within 4 hr and I hr. respectively. The elevation( respiratory metabolism in flounder exposed toO.30 ppm$CIO_2$ and above is considered due to physiological stress caused by $CIO_2$ exposure.

Atmospheric Corrosion of 7B04 Aluminum Alloy in Marine Environments

  • Zhang, Xiaoyun;Liu, Ming;Lu, Feng;Liu, Minghui;Sun, Zhihua;Tang, Zhihui
    • Corrosion Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.6-11
    • /
    • 2018
  • Outdoor exposure tests using of 7B04 aluminium alloy samples including plate, tensile and various SCC samples were carried out in Tuandao station, Shandong province (East of China) and Wanning station, Hainan province (South of China). Corrosion characteristics including weight loss, microstructure, tensile strength and SCC susceptibility were investigated. The corrosion rates in Tuandao and Wanning showed high to low and the corrosion rates changed to the following equation of $w=at^b$ (b<1). The corrosion of 7B04 aluminium alloy in Wanning was more serious than that in Tuandao. Pitting appeared at early stage of expose test, and it can be changed to general corrosion with test time extension. The 7B04 aluminium alloy of which specimen shapes are forging and thick plate also showed SCC (Stress corrosion cracking) in the marine atmosphere. The higher SCC sensitivity was observed in Wanning station than in Tuandao station. The 7B04 aluminium alloy with a high stress level was more sensitive to SCC. Intergranular and transgranular or a mixed mode of cracking can be observed in different marine exposure.