• Title/Summary/Keyword: Exposure Measure

Search Result 573, Processing Time 0.027 seconds

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Comparison of Dustiness of Eleven Nanomaterials using Voltex Shaker Method (볼텍스쉐이커를 이용한 11개 나노물질의 분진날림 비교)

  • Lee, Naroo;Park, Jinwoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.3
    • /
    • pp.273-282
    • /
    • 2018
  • Objectives: Dustiness of nanomaterials is considered as exposure index of essential material. Research on dustiness of nanomaterial is needed to control exposure in workplaces. Method: Dustiness measurement using vortex shaker were installed in the laboratory. Nanomaterials, 1 g, was put in the glass test tube and shaked using vortex shaker. Aerosol dispersed was measured using scanning mobility particle sizer(SMPS) and optical particle counter(OPC). Mass concentration using PVC filter and cassette was measured and TEM grid sampling was conducted. Total particle concentration and size distribution were calculated. Image and chemical composition of particles in the air were observed using transmission electron microscopy and energy dispersive X-ray spectrometer. Eleven different test nanomaterials were used in the study. Results: Rank of mass concentration and particle number concentration were coincided in most cases. Rank of nanomateirals with low concentration were not coincided. Two types of fumed silica had the highest mass concentration and particle number concentration. Indium tin oxide, a mixture of indium oxide and tin oxide, had high mass concentration and particle number concentration. Indium oxide had very low mass concentration and particle number concentration. Agglomeration of nanoparticles in the air were observed in TEM analysis and size distribution. In this study, mass concentration and particle number concentration were coincided and two index can be used together. The range of dustiness in particle number concentration were too wide to measure in one method. Conclusion: Particle number concentration ranged from low concentration to high concentration depend on type of nanomaterial, and varied by preparation and amount of nanomaterial used. Further study is needed to measure dustiness of all nanomaterial as one reference method.

A Study on the Measurement Linearity of Photoluminescent Dosimeter (형광유리선량계의 계측 직선성 연구)

  • Jeong, Kyeong-Hwan;Jung, Dong-Kyung;Seo, Jeong-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.841-847
    • /
    • 2021
  • Related institutions that use radiation are diverse in Korea, such as research, medical care, and education. Recently, the number of examinations and visits to medical institutions is increasing. As a result, the number of radiological examinations in medical institutions is increasing. Radiation safety management is necessary as well as exposure of radiation workers. For safety management, first of all, it is necessary to wear the personal exposure dosimeter correctly and measure it accurately after wearing it. This study tries to evaluate and verify the measurement straightness of PLD devices by radiation of a diagnostic generator. Radiation division irradiation time interval was measured after irradiating 10 times at 10, 30, and 60 sec and irradiating the irradiation distance from 30 to 100 cm at 10 cm intervals to measure the change in absorbed dose depending on the distance. As a result, there was no difference in absorbed dose by time interval. This is considered to be helpful in various studies by using a diagnostic generator for the study of high absorbed dose.

Entrance Skin Dose According to Age and Body Size for Pediatric Chest Radiography (소아 흉부촬영 시 나이와 체격에 따른 입사피부선량)

  • Shin, Gwi-Soon;Min, Ki-Yeul;Kim, Doo-Han;Lee, Kwang-Jae;Park, Ji-Hwan;Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.327-334
    • /
    • 2010
  • Exposure during childhood results in higher risk for certain detrimental cancers than exposure during adulthood. We measured entrance skin dose (ESD) under 7-year children undergoing chest imaging and compared the relationship between ESD and age, height, weight, chest thickness. Though it is important to measure chest thickness for setting up the exposure condition of chest examination, it is difficult to measure chest thickness of children. We set up exposure parameters according to age because chest thickness of children has correlation with age. In the exposure parameters, for chest A-P examination under 2 year-children, tube voltage (kVp) in hospital A was higher than that in hospital B while tube current (mAs) was higher in hospital B, thus the ESD values were about 1.7 times higher in hospital B. However, for chest P-A examination over 4 year-children, the tube voltage was 7 kVp higher in hospital B, the tube current were same in all two systems, and focus to image receptor distance (FID) in hospital B (180 cm) was longer than that in hospital A (130 cm), thus the ESD values were 1.4 times higher in hospital A. For same ages, the ESD values for chest A-P examinations were higher than those for chest P-A examinations. Comparing ESD according to age, ESD values were $154{\mu}Gy$, $194{\mu}Gy$ and $138{\mu}Gy$ for children under 1 year, 1 to under 4 years and 4 to under 7 years of age, respectively. These values were lower than reference level ($200{\mu}Gy$) recommended in JART (japan association of radiological technologists), however these were higher than reference values recommended by EC (european commission), NRPB (national radiological protection board) and NIFDS (national institute of food & drug safety evaluation). In conclusion, the values of ESD were affected by exposure parameters from radiographer's past experience more than x-ray system. ESD values for older children were not always higher than those for younger children. Therefore we need to establish our own DRLs (diagnostic reference levels) according to age of the children in order to optimize pediatric patient protection.

Reduction of the Useless Radiation Exposure to Patients and Improvement of the Skill to Manage the Test according to Minimizing Changes of Posture in Bone Mineral Density (골밀도 검사에서 환자 자세 변경 최소화에 따른 수검자의 불필요한 피폭선량 감소 및 생산성 향상)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Kim, Chang-Bok
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.228-235
    • /
    • 2009
  • As we recognize the health care, test of BMD is increased. There are various methods in BMD, Dual Energy X-ray absorptiometry (DEXA) which has high precision and accuracy, and low medical exposure dose has been widely used. To measure the changes of BMD, the test must be done as same posture at first and follow up study performed a year. we analyze the difference in the hour taken before and after the examination by radiologic technologist, frequency of scout scan, and the amount of the radiation exposure. The hour of the examination and frequency of the scout scan were shorten and the dose of the radiation exposure is reduced. As the numerical value of total subjects is converted into that of one person, the duration for the test was 52 seconds, the frequency for the scout scan 0.79 time, and the dose for the radiation exposure $13{\mu}Sv$. When the health care provider perform the precise and easy methods to minimize changes of posture and the skillful ability to manage the test, useless radiation is decreased.

The Association of Lead Biomarkers of Lead Workers with Airborne Lead Concentration in Lead Industries (납 사업장의 공기 중 납 농도 및 납 노출 근로자들의 납 관련 생물학적 노출 지표의 관련성에 관한 조사)

  • Kim, Nam-Soo;Kim, Jin-Ho;Jang, Bong-Ki;Kim, Hwa-Sung;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • This study was designed to investigate the difference of airborne lead concentration by type of lead industries and type of lead exposure and to evaluate their association with lead biomarkers of lead workers in 11 lead using industries. Total of 182 lead workers (male: 167, female: 15) from 11 lead industries were participated for this study from March, 2004 to August, 2005. Airborne lead concentration were measured by representative personal sampling of workers in each unit workplace and applied same concentration value to the workers in the same unit workplace who did not measure their airborne lead with personal air sampling. Tibia lead, blood lead, zinc protoporphyrin in whole blood, ${\delta}$-aminolevulinic acid in urine, hemoglobin and hematocrit were selected as study variables of indices of lead exposure. Information about type of lead exposure (fume or non-fume other), age, work duration, smoking & drinking habit were also collected. Significant differences were seen in the means of zinc protoporphyrin, blood lead and tibia lead in lead workers by different airborne lead concentration in workplace. While blood lead and tibia lead in lead workers were significantly higher in secondary smelting than other types of lead industries, zinc protoporphyrin, ${\delta}$-aminolevulinic acid in urine and airborne lead concentration were significantly higher in litharge manufacturing. While the mean blood lead was significantly higher in the lead workers working in fume type unit workplace than those of non-fume lead workers, the mean airborne lead concentration of fume workers was significantly lower than non-fume lead workers. In the multiple regression analysis of airborne lead concentration and the type of lead exposure on tibia lead and lead exposure indices after adjustment of related covariates, airborne lead concentration was statistically significantly associated with blood lead and tibia lead, but the type of lead exposure was only associated with blood lead. To verify the causal association of airborne lead concentration on blood lead and tibia lead, further studies are needed.

The Relationship between Exposure to Benzene and the Excretion of Urinary Trans, Trans-muconic Acid in Petrochemical Factory Turnaround Process Workers (석유화학공장 대정비 작업 근로자의 벤젠 노출과 요중 trans, trans-muconic acid 배설과의 관계)

  • Lee, Seung Min;Won, Jong Uk;Kim, Chi Nyon;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Objectives: Using laborers participating in the petrochemical factory turnaround process as subjects, this study aims to identify exposure to benzene in the air and examine the relationship between exposure and the excretion of urinary metabolites by measuring concentrations of urinary trans, trans-muconic acid (t,t-MA). Methods: A passive sampler was used to measure the level of benzene in the air. In order to analyze urinary metabolites, the urine of laborers participating in the turnaround process was collected twice daily, both before and after work. In addition, a survey was conducted on work factors and lifestyle habits as factors affecting the concentration of urinary metabolites. Results: During the survey period, benzene was detected in the samples from all workers, and its average concentration was $0.16{\pm}0.22ppm$. The average concentration of t,t-MA after work was $1.20{\pm}1.86mg/g$ creatinine, and the results of analyzing urinary metabolites concentration before and after work showed statistically significant differences(p=0.003). There was also a statistically significant correlation (r=0.52, p=0.002) between benzene in the air and the concentration of after-work urinary t,t-MA. Conclusions: During the turnaround process, the average benzene concentration in workers was $0.16{\pm}0.22ppm$, which was below the exposure limit. However, their average t,t-MA concentration was $1.20{\pm}1.86mg/g$ creatinine, which exceeded the exposure limit of 1mg/g creatinine. The characteristics of turnaround process work require considerations such as underestimating the passive sampler being used and the skin absorption of benzene, and there needs to be a simultaneous assessment of working environment measurements and biological monitoring.

Effect of Body Exposure and Color of Suit on the Impression of Modesty (의복의 색과 신체노출이 정숙성인상에 미치는 영향)

  • Koh AeRan;Kahng Hewon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.3 s.43
    • /
    • pp.181-195
    • /
    • 1992
  • The purposes of this study were to investigate 1) the effect of body exposure and color of a woman's suit on the perception of modesty, and 2) the effect of perceiver's sex and age on impression formed by the function of clothing variables. The instrument of this study consisted of a response scale and stimuli. Thirteen items of 7-point semantic differential scales were developed to measure the perceiver's impression on wearer's modesty. Stimuli were color pictures of a model wearing one of 8 types of suit constructed by a 2 $\times$ 2 $\times$ 2 factorial design. The manipulation of each level of the clothing variables were: color of the suit by black and red, leg exposure by varying skirt lengths to a Chanel-line and mini skirt, and neck exposure by shirt collar blouse and scarf. Two models, representing typical female college students living in Seoul, were selected to eliminate model effect. The sample include 384 subjects, consisting of 4 groups of male and female college students and middle aged men and women. Eight experimental groups were randomly assigned to one of eight stimuli based on between-subject design. One half of each group responded to model 1 and the other half to model 2 of same stimulus. Responses to the semantic differential scales were factor analyzed (pc model, Varimax rotation) to identify factors constructing impression of modesty. Two factors emerged regard­less of subgroups; Elegance and Extroversion factor. The first factor was found to be dominant, accounting for 60 percent of the total variance. The other accounted for just 11 percent. Multidimensional ANOVA (5-way, 3-way) was conducted to test the effect of the clothing variables against two factors identified from the factor analysis. Leg exposure was the most powerful variable affecting the impression of Elegance and Extroversion factor for all per. ceiver subgroups. Neck exposure had primary effect on the impression of Elegance, whereas it partially influenced that of Extroversion. Color of suit had only partial effect on the impression of Extroversion. Hypothesis I was partially supported from the findings above. The effect of perceiver's age and sex on impression by the function of clothing variables was tested by comparing the result between four subgroups. In forming an impression of the wearer's modesty, male college students were least affected by the manipulation of clothing variables, while middle aged males were affected most. In the female groups, there was no age difference and they fell between the male groups in the degree to which they were affected. Hypothesis II was supported only by age difference in two male groups, and by sex difference in two student groups.

  • PDF

Durability of Carbon/Epoxy Composites for Train Carbody under Salt Water Environment (염수환경에 노출된 철도차량용 탄소섬유/에폭시 복합재의 내구성 평가)

  • Yoon, Sung-Ho;Hwang, Young-Eun;Kim, Jung-Seok;Yoon, Hyuk-Jin;Kessler, Michael R.
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.4
    • /
    • pp.357-363
    • /
    • 2008
  • This study investigates the durability of carbon/epoxy composites for use on train car bodies under a salt water spray environment. Salt water solution with 5% NaCl, similar to natural salt water, was used for the salt water environmental tests. The specimens were obtained from a composite panel consisting of an epoxy matrix reinforced with T700 carbon fabric. The specimens were exposed to the salt water environment for up to 12 months. Mechanical tests were performed to obtain tensile properties, flexural properties, and shear properties. Dynamic mechanical analysis was used to measure such thermal properties as storage modulus, loss modulus, and tan $\delta$. Also FT/IR tests were conducted to investigate changes in chemical structure with exposure. The results revealed that fiber-dominated mechanical properties were not affected much by exposure time, but matrix-dominated mechanical properties decreased with increasing exposure time. Storage modulus was not very sensitive to exposure time, but glass transition temperature was affected, slightly decreasing with increasing exposure time. Although the peak intensity of FT/IR curves was affected slightly by exposure time, the peak shape and peak location of FT/IR curves were not noticeably changed. Carbon/epoxy composites used for this study were relatively stable to the salt water environment.

Exposure to Dithiopyr Alters Swimming Performance Parameters in Zebrafish (Dithiopyr에 노출이 zebrafish의 유영 행동에 미치는 영향)

  • Oh, Junyoung;Park, Eun-Jin;Kang, Seongeun;Lee, Seungheon
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.181-189
    • /
    • 2016
  • The aim of this study was to identify the effects of dithiopyr (DTP), a herbicide, on behavior in zebrafish. The toxicity of DTP has rarely been investigated in fish. In the present study, zebrafish were exposed to different concentrations of DTP in the range of 10-20 μM for 48 h in a test container, in order to measure the value of median lethal concentrations (LC50). Behavioral experiments were performed, including the novel tank test (NTT) and the open field test (OFT), to assess stress responses or locomotion. After exposure to the DTP solution at a sublethal concentration of 2.5–10 μM for 6 min, the behavior of the zebrafish was observed for 6 min. In the acute toxicity test, the LC50 value of DTP showed as 14.49 μM in the zebrafish. The NTT showed that the duration of immobility and the velocity were significantly increased by exposure at a concentration of 5 μM of DTP, compared with a control group (p<0.05). However, compared with the control group, DTP significantly decreased the distance moved and the frequency at the top of the tank, and significantly increased the turn angle and duration at the bottom, in a concentration-dependent manner (p<0.05). In addition, in the OFT, exposure to DTP significantly decreased the distance moved and velocity compared with the control group (p<0.05). Exposure to DTP also significantly increased the duration of immobility, the turn angle, and the meandering movement, in a concentration-dependent manner (p<0.05). Further, exposure to DTP at a low concentration elevated whole-body cortisol levels in the zebrafish. The results of this study thus suggest that DTP induces a toxic response and negative effects on behavior and the endocrine system in zebrafish.