• 제목/요약/키워드: Exposure Device

검색결과 429건 처리시간 0.042초

A Study on Development of Power Analysing Device for PV Module (태양전지 모듈의 발전량 분석 장치 개발에 관한 연구)

  • Moon, Chae-Joo;Kwak, Seung-Hun;Jang, Yeong-Hak;Kim, Tae-Gon;Kim, Eui-Sun;Kim, Tae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • 제30권6호
    • /
    • pp.73-80
    • /
    • 2010
  • This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1~10 of M), (11~20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is-2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by $1^{\circ}C$, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by-0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced.

The Effect of Ocean Acidification on Early Growth of Juvenile Oliver Flounder (Paralichthys olivaceus): in situ Mesocosm Experiment (해양산성화가 넙치의 초기발달에 미치는 영향: 현장 메조코즘(mesocosm) 실험)

  • Shim, Jeong Hee;Kwon, Jung-No;Park, Joo Myun;Kwak, Seok Nam
    • Korean Journal of Environmental Biology
    • /
    • 제31권4호
    • /
    • pp.353-361
    • /
    • 2013
  • An in situ mesocosm experiment was designed to investigate how exposure to ocean acidification by increased carbon dioxide affected the growth of juvenile oliver flounder (Paralichthys olivaceus). A total of 447 individuals were reared in the mesocosm experimental devices deployed at sandy-muddy bottom in the southern coast of East Sea for 43 days and divided into two groups: treatment group (223 individuals, $6.32{\pm}0.75$ cm, high-$CO_2$ environment) and control group (224 individuals, $6.34{\pm}0.84$ cm, natural $CO_2$ environment). The average values of pH and $CO_2$ concentration in the treatment device were $7.63{\pm}0.13$ and $1660{\pm}540$ ${\mu}atm$, respectively, while those in the control device were $8.07{\pm}0.05$ and $514{\pm}65$ ${\mu}atm$, respectively. There was no significant difference in mortality rate between treatment and control group, and the mortalities in two groups gradually decreased during the study period. But, the increase of size and weight of juvenile oliver flounder was higher in control group than treatment group, i.e., weight gain or growth rate was higher in control group. These results suggested that high $CO_2$ environments could have a significant negative influence on the early growth of juvenile oliver flounder.

Real-time measurement of dentinal fluid flow during desensitizing agent application (상아질 지각과민 처치제의 적용 중에 일어나는 상아세관액 유동의 실시간 측정)

  • Kim, Sun-Young;Kim, Eun-Joo;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.313-320
    • /
    • 2010
  • Objectives: The aim of this study was to examine changes in the dentinal fluid flow (DFF) during desensitizing agent application and to compare permeability after application among the agents. Materials and Methods: A Class 5 cavity was prepared to exposure cervical dentin on an extracted human premolar which was connected to a sub-nanoliter fluid flow measuring device (NFMD) under 20 cm water pressure. DFF was measured from before application of desensitizing agent (Seal&Protect, SP; SuperSeal, SS; BisBlock, BB; Gluma desensitizer, GL; Bi-Fluoride 12, BF) through application procedure to 5 min after application. Results: DFF rate after each desensitizing agent application was significantly reduced when compared to initial DFF rate before application (p < 0.05). SP showed a greater reduction in DFF rate than GL and BF did (p < 0.05). SS and BB showed a greater reduction in DFF rate than BF did (p < 0.05). Conclusions: Characteristic DFF aspect of each desensitizing agent was shown in NFMD during the application procedure.

A Study on the Distribution of Microorganisms in Department of Radiography (영상의학과 촬영실의 미생물 분포에 관한 연구)

  • Chang, Jeong-Hyun;Yang, Eun-Ju;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • 제15권2호
    • /
    • pp.165-171
    • /
    • 2021
  • To prevent the secondary hospital-acquired infection (cross-infection) from occurring in the general radiographic room in the department of radiology, the microbial measurement was conducted at the points making direct close contact with radiologists and patients. For the case of radiologists, the microbial measurement and incubation were focused on the x-ray tube handle of the radiation generating device, and, for the case of patients, the microbial measurement and incubation were focused on the chin supporting device, chest-contact point, and handle. Once disinfected with Aniosurf, the sterilized media were gathered and identified, and the microorganisms were confirmed. Based on the identification results, it was confirmed that the points making direct close contact with radiologists showed a value of 103 CFU for Proteus mirabilis, Staphylococcus epidermidis, Bacillus spp. and Candida spp., and that the points making direct close contact with patients showed a value of 103~5 CFU for Proteus mirabilis, Enterococcu faecium, Pseudomonas aeruginosa, NTM(Non-Tuberculosis Mycobacteria) and Candida spp.. It was also confirmed that the types and number of microorganisms gathered from the points making direct close contact with patients were greater. Fortunately, most of the involved microorganisms were observed to be on the skin surface and are known to become extinct when disinfected in accordance with the hospital-acquired infection control rules. However, since even minor exposure to such microorganisms may be lethal for patients with reduced immunity, caution must be taken. In particular, since the points making contact with patients showed a high level of microbial measurement, it was thought that it would be necessary for radiologists and personnel having frequent access to strictly disinfect the parts, such as instruments and handles, making frequent contact with patients. The purpose of this study was to announce the importance of safe microbial control in the radiographic inspection room in hospital, and this study is expected to be used as the baseline data for preventing hospital-acquired secondary infection and Nth infectious diseases.

A STUDY ON THE APPLICATION OF DYNAMIC TOMOGRAM OF THE HUMAN HEAD (인체 두부에서 Dynamic Tomogram의 응용에 관한 연구)

  • Choi Eui Whan;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • 제21권2호
    • /
    • pp.317-326
    • /
    • 1991
  • The purpose of this study was to establish the principle and the clinical application of dynamic tomogram of a human head by using the dental machine. For this study, a block of wax with details lying at three parallel planes and a human dry skull were used. This experiment was reexamined the dynamic tomogram with specialized radiographic device and view box, and the radiograms taken by the change of exposure time according to the numbers of film used in x-ray taking and taken according to the change of kVp and the types of film were analyzed density with the densitometer. From this study, the obtained results were as follows: 1. When the underexposed radiograms taken by angulation of clockwise and counter-clockwise direction of the film and skull. were superimposed and moved laterally, it was possible to focus on right and left jaws and teeth. 2. The superimposition of the two underexposed radiograms according to each condition of x-ray taking showed some differencies in density visually, and the measurement of density with the densitometer was 1.23 to 1.57 in 75kVp and 1.34 to 1.70 in 90kVp. 3. The superimposition of the two underexposed radiograms according to the kinds of x-ray film showed almost equal density visually, and the measurement of density with the densiometer was 1.34 to 1.37. 4. When seven radiograms taken by each condition of x-ray taking were superimposed on the view box, a intense rear light of view box didn't transilluminate film density regardless of the conditions of x-ray taking. Even though seven radiograms taken according to types of film were superimposed on the view box, a more intense rear light of view box was required to transilluminate total density of films. 6. Long film-object distance resulted in the enlargement and blurring of radiographic images.

  • PDF

Service Management Scheme using Security Identification Information adopt to Big Data Environment (빅데이터 환경에 적합한 보안 인식 정보를 이용한 서비스 관리 기법)

  • Jeong, Yoon-Su;Han, Kun-Hee
    • Journal of Digital Convergence
    • /
    • 제11권12호
    • /
    • pp.393-399
    • /
    • 2013
  • Recently, the quantity and type of data that is being processed in cloud environment are varied. A method for easy access in different network in a heterogeneous environment of big data stored in the device is required. This paper propose security management method for smoothly access to big data in other network environment conjunction with attribute information between big data and user. The proposed method has a high level of safety even if user-generated random bit signal is modulated. The proposed method is sufficient to deliver any number of bits the user to share information used to secure recognition. Also, the security awareness information bit sequence generated by a third party to avoid unnecessary exposure value by passing a hash chain of the user anonymity is to be guaranteed to receive.

A study on Computer-controlled Ultrasonic Scanning Device (컴퓨터제어에 의한 자동초음파 탐상장치에 관한 연구)

  • Huh, H.;Park, C.S.;Hong, S.S.;Park, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • 제9권1호
    • /
    • pp.30-38
    • /
    • 1989
  • Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipments has been one of the important research and development(R & D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develope Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials.

  • PDF

Camera Self-Calibration from Two Ellipse Contours in Pipes

  • Jeong, Kyung-Min;Seo, Yong-Chil;Choi, Young-Soo;Cho, Jai-Wan;Lee, Sung-Uk;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1516-1519
    • /
    • 2004
  • A tele-operated robot should be used to maintain and inspect nuclear power plants to reduce the radiation exposure to the human operators. During an overhaul of the nuclear power plants in Korea, a ROV(Remotely Operated Vehicle) may enter a cold-leg connected to the reactor to examine the state of the thermal sleeve and it's position in the safety injection nozzle. To measure the positions of the thermal sleeve or scratches from the video images captured during the examination, the camera parameters should be identified. However, the focal length of the CCD camera could be increased to a close up of the target and the aspect ratio and the center of the image could also be varied with capturing devices. So, it is desired to self-calibrated the intrinsic parameters of the camera and capturing device with the video images captured during the examination. In the video image of the safety injection nozzle, two or more circular grooves around the nozzle are shown as ellipse contours. In this paper, we propose a camera self-calibration method using a single image containing two circular grooves which are the greatest circles of the cylindrical nozzle whose radius and distance are known.

  • PDF

Application of Calibration Techniques to Enhance Accuracy of Markerless Surgical Robotic System for Intracerebral Hematoma Surgery (뇌혈종 제거 수술을 위한 무마커 수술 유도 로봇 시스템의 정확도 향상을 위한 캘리브레이션 기법)

  • Park, Kyusic;Yoon, Hyon Min;Shin, Sangkyun;Cho, Hyunchul;Kim, Youngjun;Kim, Laehyun;Lee, Deukhee
    • Korean Journal of Computational Design and Engineering
    • /
    • 제20권3호
    • /
    • pp.246-253
    • /
    • 2015
  • In this paper, we propose calibration methods that can be applied to the markerless surgical robotic system for Intracerebral Hematoma (ICH) Surgery. This surgical robotic system does not require additional process of patient imaging but only uses CT images that are initially taken for a diagnosis purpose. Furthermore, the system applies markerless registration method other than using stereotactic frames. Thus, in overall, our system has many advantages when compared to other conventional ICH surgeries in that they are non-invasive, much less exposed to radiation exposure, and most importantly reduces a total operation time. In the paper, we specifically focus on the application of calibration methods and their verification which is one of the most critical factors that determine the accuracy of the system. We implemented three applications of calibration methods between the coordinates of robot's end-effector and the coordinates of 3D facial surface scanner, based on the hand-eye calibration method. Phantom tests were conducted to validate the feasibility and accuracy of our proposed calibration methods and the surgical robotic system.

Clinical Application of DIAGNOcam (DIAGNOcam의 임상적 적용)

  • Kim, Jinhyock;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제43권4호
    • /
    • pp.461-466
    • /
    • 2016
  • Dental caries is an important dental disease among children and adolescents that can continue for a lifetime. Early detection of dental caries in deciduous dentition is significant because it can influence the permanent teeth. It is also critical to prevent dental caries by performing fluoride treatment and pit-and-fissure sealant for high-risk children. Various methods have been developed for the early detection of dental caries; however, many studies are still seeking to discover more effective methods. In general, visual examination and radiographic images are used, but these techniques have several limitations such as errors and radiation exposure. In this study, clinical application of the newly developed DIAGNOcam caries identification device and its possible applications were examined. DIAGNOcam was applied to diagnose dental caries in the posterior teeth of patients in the Department of Pediatric Dentistry, and it was confirmed that it could be used to detect proximal caries, the margin of restoration, and the extent of dental caries lesions.