• Title/Summary/Keyword: Exposure Device

Search Result 432, Processing Time 0.032 seconds

A Brief Review on Variables and Test Priorities of Photovoltaic Module Life Expectancy

  • Padi, Siva Parvathi;Chowdhury, Sanchari;Zahid, Muhammad Aleem;Kim, Jaeun;Cho, Eun-Chel;Yi, Junsin
    • Current Photovoltaic Research
    • /
    • v.9 no.2
    • /
    • pp.36-44
    • /
    • 2021
  • To endorse the reliability and durability of the solar photovoltaic (PV) device several tests were conducted before exposing to the outdoor field in a non-ideal condition. The PV module has high probability that intend to perform adequately for 30 years under operating conditions. To evaluate the long term performance of the PV module in diversified terrestrial conditions, one should use the outdoor performance data. However, no one wants to wait for 25 years to determine the module reliability. The accelerating stress tests performing in the laboratory by mimicking different field conditions are thus important to understand the performance of a PV module. In this review, we will discuss briefly about different accelerating stress types, levels and prioritization that are used to evaluate the PV module reliability and durability before using them in real field.

Basic Performance Evaluation of the Ecotoxicity Detection Device for Heavy Metals (중금속류 생태독성 검출장치의 기초성능 평가)

  • Kim, IlHo;Kim, Ji-Sung;Yoon, Young-Han;Ban, Hyo-Jin;Kim, Seok-Gu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.828-834
    • /
    • 2012
  • The ecotoxicity detection device for preliminary test (Test jig) was manufactured to develop the biological early warning system using Vibrio fischeri. In this study, the ecotoxicity detection charateristics of the Test jig was investigated for 6 heavy metals (Cr, Zn, Pb, Cd, Cu and Hg). It was observed that relative luminescence unit (RLU) of Vibrio fischeri constantly decreased by the concentrations of the tested heavy metals. In contrast with other heavy metals, RLUs of Pb and Hg constantly decreased even at low concentrations. RLU of Hg drastically decreased when its concentration increased from 0.13 mg/L to 0.25 mg/L. $EC_{50}$ values of Cr, Zn, Pb and Cd gradually decreased with exposure time, whereas there was no significant change in $EC_{50}$ values of Cu and Hg with time. On the other hand, $EC_{50}$ values between the Test jig and Reference device were compared to evaluate the ecotoxicity detection performance of the Test jig. No big difference was found in $EC_{50}$ vlaues between the two devices, indicating that the Test jig could be applied as the ecotoxicity detection device for heavy metals.

Development of High Energy X-ray Dose Measuring Device based Ion Chamber for Cargo Container Inspection System (이온전리함 기반의 컨테이너 검색용 고에너지 X-선 선량 측정장치 개발)

  • Lee, Junghee;Lim, Chang Hwy;Park, Jong-Won;Lee, Sang Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1711-1717
    • /
    • 2020
  • X-ray of up to 9MeV are used for container inspection. X-ray intensity must be maintained stably regardless of changes in time. If dose is not constant, it may affect the image quality, and as a result, may affect the inspection of abnormal cargo. Therefore, to acquire high-quality images, continuous dose monitoring is required. In this study, the ion-chamber based device was developed for monitoring the dose change in high-energy x-ray. And to estimate the performance of signal-processing device change according to the environmental change, the output changing due to the change of temperature and humidity was observed. In addition, verification of the device was performed by measuring the output change. As a result of the measurement, there was no significant difference in performance due to changes in temperature and humidity, and the change in output according to the change in exposure was linear. Therefore, it was found that the developed device is suitable for the dose monitoring of high-energy x-ray.

Development of Geometrical Quality Control Real-time Analysis Program using an Electronic Portal Imaging (전자포탈영상을 이용한 기하학적 정도관리 실시간 분석 프로그램의 개발)

  • Lee, Sang-Rok;Jung, Kyung-Yong;Jang, Min-Sun;Lee, Byung-Gu;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.77-84
    • /
    • 2012
  • Purpose: To develop a geometrical quality control real-time analysis program using an electronic portal imaging to replace film evaluation method. Materials and Methods: A geometrical quality control item was established with the Eclipse treatment planning system (Version 8.1, Varian, USA) after the Electronic Portal Imaging Device (EPID) took care of the problems occurring from the fixed substructure of the linear accelerator (CL-iX, Varian, USA). Electronic portal image (single exposure before plan) was created at the treatment room's 4DTC (Version 10.2, Varian, USA) and a beam was irradiated in accordance with each item. The gaining the entire electronic portal imaging at the Off-line review and was evaluated by a self-developed geometrical quality control real-time analysis program. As for evaluation methods, the intra-fraction error was analyzed by executing 5 times in a row under identical conditions and procedures on the same day, and in order to confirm the infer-fraction error, it was executed for 10 days under identical conditions of all procedures and was compared with the film evaluation method using an Iso-align$^{TM}$ quality control device. Measurement and analysis time was measured by sorting the time into from the device setup to data achievement and the time amount after the time until the completion of analysis and the convenience of the users and execution processes were compared. Results: The intra-fraction error values for each average 0.1, 0.2, 0.3, 0.2 mm at light-radiation field coincidence, collimator rotation axis, couch rotation axis and gantry rotation axis. By checking the infer-fraction error through 10 days of continuous quality control, the error values obtained were average 1.7, 1.4, 0.7, 1.1 mm for each item. Also, the measurement times were average 36 minutes, 15 minutes for the film evaluation method and electronic portal imaging system, and the analysis times were average 30 minutes, 22 minutes. Conclusion: When conducting a geometrical quality control using an electronic portal imaging, it was found that it is efficient as a quality control tool. It not only reduces costs through not using films, but also reduces the measurement and analysis time which enhances user convenience and can improve the execution process by leaving out film developing procedures etc. Also, images done with evaluation from the self-developed geometrical quality control real-time analysis program, data processing is capable which supports the storage of information.

  • PDF

Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners (투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구)

  • Yang, Hae-Doo;Hong, Seon-Sook;Seong, Min-Sook;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Applicability of CATIS as a Postharvest Phytosanitation Technology against the Peach Fruit Moth, Carposina sasakii Matsumura (복숭아심식나방(Carposina sasakil)의 수확 후 소독 처리로서 CATTS 기술의 적용 가능성)

  • Son, Ye-Rim;Choi, Kyung-Hee;Kim, Yong;Kim, Yong-Gyun
    • Korean journal of applied entomology
    • /
    • v.49 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • As an environment-friendly phytosanitary measure, CATTS (controlled atmosphere temperature treatment system) has been developed to kill several quarantine insect pests infesting subtropical agricultural commodities. This study tested any possibility to apply CATTS to apples to effectively eliminate the peach fruit moth, Carposina sasakii, which has been regarded as a quarantine insect from the imported countries. When the larvae of C. sasakii were directly exposed to $46^{\circ}C$ (an installed lethal temperature of CATTS), they showed a median lethal time at 14.66 min. Addition of high carbon dioxide to the temperature treatment enhanced the thermal limit susceptibility of C. sasakii to $46^{\circ}C$. CATTS device was constructed to automatically control $CO_2$ concentration and temperature with real-time monitoring both in the chamber and in the fruit. The larvae internally infesting apples were tested using the CATTS device and showed 100% lethality after 60 min exposure to a treatment of $46^{\circ}C$ under 15% $CO_2$ in the chamber. Relatively long exposure may be due to the deviation between the ramping temperature ($0.35^{\circ}C$/min) of the chamber and the ramping temperature (0.12-$0.23^{\circ}C$/min) inside apple fruit, where the tested larvae were located. This study suggests a possibility that CATTS can be applied as a quarantine measure to kill the larvae of C. sasakii locating inside the apples.

Effects of Organic Passivation Films on Properties of Polymer Solar Cells with P3HT:PC61BM Active Layers (유기 패시베이션 박막이 P3HT:PC61BM 활성층을 갖는 고분자 태양전지의 특성에 미치는 영향)

  • Lee, Sang Hee;Park, Byung Min;Cho, Yang Keun;Chang, Ho Jung;Jung, Jae Jin;Pyee, Jaeho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.4
    • /
    • pp.105-110
    • /
    • 2014
  • It is required to improve the efficiency and the reliability of the polymer solar cells (PSCs) as the energy saving optical device for the future application of the smart farm facilities. In this study, we fabricated the bulk hetero junction PSCs with organic passivation film layer for the reliability improvement of the devices. The effects of the passivation layer on the electrical properties of the PSCs were studied. The materials of passivation layer are composed of poly vinyl alcohol (PVA) and ammonium dichromate, and the passivation films were fabricated by the spin coating method on the P3HT:$PC_{61}BM$/LiF/Al substrate. The prepared structure of the device is the glass/ITO/PEDOT:PSS/P3HT:$PC_{61}BM$/LiF/Al/passivation layer. The performances of the PSCs with the organic passivation film showed better electrical properties compared with the PSCs without passivation layers. The power conversion efficiency (PCE) values of passivated PSCs decreased from 3.0 to 1.3% after air exposure for 140 hrs. In contrast, the PCE values for the devices without passivation decreased sharply from 3.5 to 0.1% under the same exposure condition.

Study on Research for Reducing Radiation Dose of Head and Neck for Cephalometric Radiography System (두부규격방사선촬영장치의 두경부 피폭 저감에 대한 연구)

  • OH, Yoonjin;Shin, Jae-won;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.291-298
    • /
    • 2016
  • Recently, the interest in the orthodontic treatment for children is increased by a rise in national income level. The number of cephalometric radiography that could diagnose a malocclusion and malposition between teeth and jawbone increased. It required attention to radiation exposure, because the subject of dental examination is children which are more sensitive to radiation and the head and neck, the object of that include radiation sensitive organ such as the thyroid, bone marrow, eyes, salivary gland, and so on. In this study, we measured two-dimensional dose distribution in cephalometric radiography system (VATEC Pax-400C) using Agfa CP-G Plus film and MagicMax Dosimeter, and calculated radiation organ dose of head and neck through MCNPX simulation. And then we designed a radiation protective device to decrease radiation dose. The dose distribution of the cephalometric radiography system irradiated the head and neck overall as well as the oral and maxillofacial parts. The radiation organ dose calculated that thyroid, oesophagus and eyes are irradiated high, and the radiation organ dose decreased about 70 ~ 80% by the application of the radiation protective device. The results of this study will be used construction of database for dental radiation exposure and research of reducing radiation dose.

Investigation of Physical Imaging Properties in Various Digital Radiography Systems (다양한 디지털 방사선 시스템의 물리적 영상 특성 조사)

  • Jeong, Hoi-Woun;Min, Jung-Hwan;Yoon, Yong-Su;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.363-370
    • /
    • 2017
  • We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

Changes of Acoustic Reflex Thresholds and Speech-In-Noise Perception Using Personal Listening Device Under Subway Interior Noise (지하철 실내 소음 하에서 음향기기 사용에 따른 음향반사역치와 소음 속 어음인지 변화)

  • Han, Woojae;Chun, Hyungi;Ma, Sunmi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.138-145
    • /
    • 2015
  • Although it is well-known that environmental noise can lead to hearing loss in individuals, the true extent of subway noise effects in the general population remains poorly understood. The purpose of the present study is to see changes of acoustic reflex thresholds and speech perception scores when passengers listen to music presented from their personal listening device in the subway. Forty subjects with normal hearing participated being divided into two groups, experimental and control groups. As a baseline, all subjects were measured by acoustic reflex thresholds in five test frequencies and Korean speech perception in noise (KSPIN) test at 0 and -5 dB SNR. In the experiment, the control group read newspaper or magazine in the subway noise, whereas the experimental group listened to music presented from their smartphone under the subway noise through speakers at 73.45 dBA for 60 min. After completing the experiment, two groups also conducted both acoustic reflex thresholds and KSPIN tests in the same condition as the baseline. The results showed that there was a significant difference of correct percent in speech-in-noise test between experimental and control groups and of that between two signal-to-noise ratios, which means the double noise exposure of 60 min might cause some degradation of speech perception when noise increases compared to only subway noise condition that was not statistically significant difference. We concluded that a risk of some degraded speech perception ability would be expected when passengers have a habit of listening to music in the subway noisy situation for a long duration.