Extreme Ultraviolet Plasma and its Emission Characteristics Generated from the Plasma Focus in Accordance with Gas Pressure for Biological Applications

  • Kim, Jin Han;Lee, Jin Young;Kim, Sung Hee;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.178.2-178.2
    • /
    • 2013
  • Conventional ultraviolets A,B,C are known to be very important factor of killing, changing surface properties of biological cells and materials. It is of great importance to investigate the influence of extreme ultraviolet (EUV) exposure on the biological cell. Here we have studied high density EUV plasma and its emission characteristics, which have been generated by plasma focus device with hypercycloidal pinch (HCP) electrode under various Ar gas pressures ranged from 30~500 mTorr in this experiment. We have also measured the plasma characteristics generated from the HCP plasma focus device such as electron temperature by the Boltzman plot, plasma density by the Stark broading method, discharge images by open-shuttered pin hole camera, and EUV emission signals by using the photodiode AXUV-100 Zr/C.

  • PDF

디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안 (Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography)

  • 신성규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제36권2호
    • /
    • pp.111-122
    • /
    • 2013
  • 본 연구는 디지털방사선장비에서 자동노출제어장치 사용 시 초점-검출기간의 거리, 관전압, 구리필터의 조합을 이용해 환자의 피폭을 감소하고자 시행 하였다. 경추, 요추측면검사, 두개골 전후검사법을 대상으로 관전 압은 60~100 kV, 초점-검출기간의 거리는 100~200 cm으로 변화시키고 구리필터를 추가하면서 입사선량을 측정하고 영상을 평가하였다. 입사선량은 경추측면검사에서 90 kV, 0.3 mmCu, 200 cm일 경우에 0.06 mGy, 요추측면검사에서는 100 kV, 0.3 mmCu, 200 cm일 경우 0.40 mGy, 두개골전후검사에서는 90 kV, 0.3 mmCu, 140 cm일 경우 0.24 mGy로 가장 낮았다. 입사선량은 0.1 mmCu, 150 cm, 70 kV (경추측면검사), 81 kV (요추측면검사)로 변화 시켰을 경우에 가장 큰 폭으로 감소했다. 초점-검출기간의 거리가 늘어날수록 영상의 확대가 줄었고 180 cm 이상에서는 차이가 적었다. 두개골전후검사에서는 80 kV, 0.1 mmCu, 120 cm으로 변화했을 경우에 입사선량이 가장 많이 감소했다. 따라서 자동노출제어장치를 사용할 시 영상의 품질을 고려한 범위에서 최대한 높은 관전압을 사용하고 초점-검출기간의 거리는 검사실의 구조, 방사선사의 신체조건을 감안하여 선 검사대(Wall)에서는 150~200 cm, 누운 검사대(Table)에서는 120~140 cm으로 늘리고 0.1~0.3 mm Cu의 부가필터를 적절히 조합하여 사용하는 것이 영상의 왜곡 방지와 입사선량을 감소시켜 환자의 피폭을 줄일 수 있을 것이다.

치과용 초소형 X-선 튜브의 선량평가 (Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging)

  • 지윤서;김연우;이레나
    • 한국의학물리학회지:의학물리
    • /
    • 제26권3호
    • /
    • pp.160-167
    • /
    • 2015
  • 의료용 x선 촬영 장치에 있어서 환자에게 피폭되는 선량이 가장 중요한 관심사 중의 하나이다. 본 연구팀에서는 전 세계 최초로 입안에 삽입이 가능한 초소형 x-선 영상 장치가 개발되었는데 이러한 영상장치를 임상에서 사용하기 위해서는 피폭 선량의 평가가 필수적이다. 따라서 본 연구에서는 신개념 치과용 영상장치의 선량을 평가하기 위하여 1) 돼지 턱뼈 팬텀을 직접 제작하여 영상의 질을 평가 하였고, 2) 실제 임상에서 사용가능한 촬영 조건을 결정하였으며, 3) 결정된 촬영 조건에서의 선량을 평가 하였다. 한국 식약처에서 제시하는 치근단 촬영에 대한 환자 선량 권고량(DRLs) 기준에 근거하여 새 개발 장비의 입사표면선량(ESD)와 면적선량(DAP) 측정 방법을 고안하고 각각의 선량 값을 측정하였다. 관전압이 45~55 kV, 관전류가 300 mA 까지 사용 가능한 xoft 사의 초소형 x선 튜브를 사용하였다. 사용된 검출기는 active area가 $72{\times}72mm$ 이고 픽셀 사이즈는 $48{\mu}m$ 이다. 제작된 돼지턱뼈 팬텀은 1 frame/sec의 조건하에 영상을 획득 하였으며, 촬영 조건 최적화를 위하여 관전류를 $20{\sim}80{\mu}A$로 변화시키면서 50 frame씩 영상을 획득하였다. 또한, 상용화 치과용 영상시스템(모델명: CS 2100, 제조사: Carestream Dental LLC 및 모델명: EXARO, 제조사: HIOSSEN)을 이용하여 돼지턱뼈 팬텀의 비교영상 평가를 시행하였다. CS 2100는 60 kV, 7 mA (노출시간:0.125 s)로 하였으며, EXARO는 60 kV, 2 mA로 설정하였다. 선량 평가는 광자극 형광 선량계를 이용하여 입사표면선량을 측정하였으며, 팬텀은 PMMA 재질의 제작된 원통형 팬텀을 이용하였다. 선량계는 팬텀 표면상의 조사야 내부에 2개 및 소스와의 5 cm 거리상에 1개를 위치하여 측정하였다. 빔 조사 조건은 51, 101, 141, $196{\mu}As$로 설정하였다. 면적선량은 소스와 검출기간의 거리가 5 cm 위치에 배치하여 측정하였으며, 이 때 촬영조건은, 관전류 41, 99, 144, 207, $276{\mu}As$의 조건하에서 측정하였다. 임상에서 적용 가능한 관전압과 관전류는 X-선 세기 8000~9000인 지점에서의 관전류 값인 0.051 mAs 이다. 상용화 장비와 영상비교를 한 결과, 개발 장비의 조사야가 훨씬 작음에도 불구하고 치아 및 치아 주위 조직의 영상이 더 우수함을 확인하였다. 또한, 영상 최적화 조사조건인 $51{\mu}As$에서 입사표면선량(ESD)은 식약처 및 IAEA의 권고치보다 훨씬 낮은 1.369 mGy 이다. 조사야 내부의 선량 분포는 표준편차 5~10% 내외로 균일성이 우수 하였다. 측정된 면적선량(DAP)은 $82.4mGy*cm^2$으로 상용화 장비보다 조사야가 훨씬 작음에도 불구하고 식약처의 권고치보다 낮은 값을 보였다. 이러한 연구를 통해서 새 개발 장비의 영상의 우수성과 기존 장비 대비 방사선량에 대한 저감 효과를 확인 할 수 있었으며 치과 장비 개발에 있어서 X선 특성 연구에 대한 기술과 노하우를 축적할 수 있었다.

몰입형 가상교육을 위한 입력장치 (Input Device for Immersive Virtual Education)

  • 정구철;임성민;김상연
    • 한국실천공학교육학회논문지
    • /
    • 제5권1호
    • /
    • pp.34-39
    • /
    • 2013
  • 본 연구에서는 사용자에게 가상환경에 존재하는 교육컨텐츠와 자연스럽게 안터랙션 할 뿐 아니라 인터랙션 양에 따라서 사용자에게 햅틱 정보를 전달해 줄수 있는 휴대용 입력장치를 제시한다. 제안하는 시스템은 사용자의 움직임을 측정하고 움직임에 따라서 사용자에게 햅틱 정보를 되돌려 준다. 교육 컨텐츠와 사용자의 인터랙션에 따른 햅틱 감각을 생성하기 위해 제안하는 입력장치는 모션 제어기, 햅틱 액츄에이터, 무선 통신 모듈, 그리고 모션센서로 구성한다. 사용자의 모션 입력을 측정하기 위해서 가속도 선서를 사용한다. 실험을 통해 제안하는 시스템이 떨림없이 안정적이고 연속적인 햅틱 감각이 생성됨을 파악한다.

  • PDF

스마트폰 관리 표준(OMA DM)에 관한 연구 (A Study on the smartphone management standards(OMA DM))

  • 배정민;정성재;배유미;장래영;소우영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.253-255
    • /
    • 2013
  • 이동통신 산업의 기술 및 보급이 급격하게 발전함에 따라 개인 및 기업의 정보가 위험에 노출 되고 있다. 현재 우리는 이렇게 노출 된 정보들로 인해 개인의 신변을 위협하고, 기업 및 연구소 등의 기술 유출로 인해 국가적으로 막대한 손해를 입을 수 있는 상황에 직면하고 있다. 이를 해결하기 위해 본 연구에서는 모바일 서비스 표준화 단체인 OMA(Open Mobile Alliance)에서 모바일 장치의 소프트웨어 관리 및 디바이스 장치를 관리하기 위해 프로토콜과 메커니즘을 지정한 DM(Device Management) 표준에 대한 스마트폰의 어플리케이션 관리 및 디바이스 장치 제어 기술의 원리에 관하여 연구하였다.

  • PDF

Reduced Graphene Oxide Field-Effect Transistor for Temperature and Infrared Sensing

  • Trung, Tran Quang;Tien, Nguyen Thanh;Kim, Do-Il;Lee, Nae-Eung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.552-552
    • /
    • 2012
  • We fabricated reduced graphene oxide field-effect transistor (RGO-FET) on glass for highly sensitive temperature and IR detection. The device has the channels of RGO responsive to physical stimuli such as temperature and IR. The RGO sensing layers are fabricated from exfoliated graphene oxide sheets that are deposited to form a thin continuous network by electrostatic assembly. These graphene oxide networks are reduced toward reduce graphene oxide by exposure to a hydrazine hydrate vapor. To improve performance and eliminate interferences from oxygen and water vapor absorption to electrical properties of RGO-FET, the sensor devices were encapsulated by the tetratetracontane layer after annealing treatment. The device with encapsulation layer showed lower hysteresis, improved stability, and better repeatability. The temperature response of RGO-FET is examined by measuring changing the temperature, the device exhibited the high sensitivity and repeatability even with the temperature interval of 1 K. We also demonstrated that our devices have capability of IR sensing.

  • PDF

동물병원 방사선 안전관리체계에 대한 연구 (Study of Radiation Safety Management of Veterinary Hospital in Korea)

  • 채수영;최호정;이영원
    • 한국임상수의학회지
    • /
    • 제37권1호
    • /
    • pp.15-22
    • /
    • 2020
  • This study investigated the effectiveness of radiation safety rules in animal hospital and the awareness and behavior of veterinary radiation workers. With the questionnaires, the data was collected from randomly selected veterinarians in animal hospitals and animal medical imaging centers. Collected data were about radiation device, shielding device, regulations, safety management, education, knowledge, behavior and awareness. Frequency, correlation and multiple regression analysis were performed. The medical devices related with radiation in animal hospital were X-ray (59%), CT (15%), fluoroscopy (12%), mobile X-ray (12%) and others (2%). The number of people using radiation shielding device is high. The answers were low on knowing radiation related regulation and receiving radiation protection education. The group with higher knowledge and awareness shows positive correlation with safety behavior. The increase of use of the radiation related medical devices in veterinary hospital causes the increase of radiation exposure risk. This study suggests that radiation safety management system and policies need to be developed to protect radiation workers and give them correct information and consciousness.

Spectral-shape-controllable Chirped Fiber Bragg Grating with a Photomechanical Microactuator: Simulation and Experiment

  • Moon, Jong-Ju;Ko, Youngmin;Park, Su-Jeong;Ahn, Tae-Jung
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.477-482
    • /
    • 2020
  • Recently, one of the authors has been reported an optically tunable fiber Bragg grating (FBG) with a photomechanical polymer. It was based on a typical FBG with a downsized diameter of 60 ㎛, coated with azobenzene-containing polymer material. Azobenzene is a well-known reversibly photomechanical stretchable material under ultraviolet (UV) light. The small part of the functional-coating region on the FBG absorbed UV light, which pulled the UV-exposed part of the grating. It was selectable as tunable FBG or tunable chirped FBG, by adjusting the position of UV exposure on the grating. As proof of concept for the tunable FBG device, the characteristics just including UV-induced center-wavelength shift and spectral-width changes of the device were reported. In this paper, we report for the first time that the microactuator makes it possible to control the spectral shape of the FBG reflection, according to the specifications (shape and intensity) of the UV beam that reaches the FBG coated with the azobenzene polymer. In addition, we provide the group-delay profiles for the chirped FBG, so that the sign of its dispersion (normal or anomalous) can be tailored by simply selecting the moving direction of the UV light's displacement in the experiment.

흉부 CR 영상에서 선량이 화질에 미치는 영향에 대한 평가 (Assessment of dose effects on image quality at chest computed radiography)

  • 강보선
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.421-426
    • /
    • 2011
  • 본 연구는 CR영상에서 선량이 화질에 미치는 영향을 평가하기위해 수행되었다. 본 연구의 궁극적인 목적은 임상 흉부진단에 필요한 영상화질을 얻을 수 있는 최적 선량을 찾는 것이다. 영상화질 평가를 위해서 다양한 선량에서의 MTF, NNPS, 그리고 NEQ를 측정하였으며, MTF 측정과 실험장치 구성은 International Electrotechnical Commission(IEC)에서 제시한 절차에 따라 수행하였다. 실험 결과를 통해 흉부진단의 경우 자동노출조절 (Automatic Exposure Control, AEC) 제어반에서 자동으로 설정해주는 선량의 절반 선량으로도 필요한 영상화질이 얻어짐을 알 수 있었다. 본 연구를 통해 AEC에서 제시하는 선량이 최적 선량이 아니며 화질평가를 통해서 얻어진 최적 선량을 사용하면 환자의 피폭을 상당량 줄일 수 있음을 보였다.

직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구 (Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement)

  • 여진희;최광민
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.