• Title/Summary/Keyword: Explosion risk

Search Result 340, Processing Time 0.024 seconds

Monte Carlo analysis of the induced cracked zone by single-hole rock explosion

  • Shadabfar, Mahdi;Huang, Hongwei;Wang, Yuan;Wu, Chenglong
    • Geomechanics and Engineering
    • /
    • v.21 no.3
    • /
    • pp.289-300
    • /
    • 2020
  • Estimating the damage induced by an explosion around a blast hole has always been a challenging issue in geotechnical engineering. It is difficult to determine an exact dimension for damage zone since many parameters are involved in the formation of failures, and there are some uncertainties lying in these parameters. Thus, the present study adopted a probabilistic approach towards this problem. First, a reliability model of the problem was established and the failure probability of induced damage was calculated. Then, the corresponding exceedance risk curve was developed indicating the relation between the failure probability and the cracked zone radius. The obtained risk curve indicated that the failure probability drops dramatically by increasing the cracked zone radius so that the probability of exceedance for any crack length greater than 4.5 m is less than 5%. Moreover, the effect of each parameter involved in the probability of failure, including blast hole radius, explosive density, detonation velocity, and tensile strength of the rock, was evaluated by using a sensitivity analysis. Finally, the impact of the decoupling ratio on the reduction of failures was investigated and the location of its maximum influence was demonstrated around the blast point.

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.

Design and Implementation of Automatic Fan On/Off for Energy Saving (에너지 절감을 위한 선풍기 자동 ON/OFF 기능의 설계 및 구현)

  • Jang, Junewoo;Park, Seongjin;Ko, Hyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.5-8
    • /
    • 2018
  • Recently, global warming and tropical nights have caused the use of electric fans to explode. Under these circumstances, running the fan for long periods of time is not only a risk of explosion due to overloading the power but also a small amount of electricity and environmental pollution. Therefore, the research was conducted to develop devices that automatically turn fans on and off according to room temperature, reducing the risk of explosion as well as saving energy. This study suggested that electric fans turn on and off automatically and display temperature in mobile applications. The ability to turn on and off allows the fan to turn on itself if the indoor temperature rises above a certain level. Conversely, if the indoor temperature drops below a certain level, the fan should be turned off. Second, the temperature display function checks indoor temperature through mobile applications. The automatic on/off capabilities proposed in this study could contribute to reducing the risk of explosion and saving energy. However, if the indoor temperature rises above a certain temperature even though there is no one inside, the fan can be turned on. The expectation from this study is that the ability of fans to operate and turn off at appropriate temperatures can reduce the risk of explosion, electrical charges, and environmental pollution.

  • PDF

Valve monitoring system design and implementation using an infrared sensor and ZigBee (Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현)

  • Sim, Hyun;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • The valve device is installed in hazardous areas, such as a chemical plant explosion has been sealed with fire protection device to prevent the risk of explosion. In this paper, due to the explosion-proof devices using external power the device can not be used in infrared sensors and Zigbee sensor valve device by measuring the open degree of valve opening and closing of the danger zone to check whether. Valve opening and closing operation log screen time, we propose a low-power operation monitoring system administrators to manage and control the plant. Develop power control relay board apply an improved algorithm to apply the asynchronous LPL power management. The plant monitoring system and explosion-proof valve opening and closing the valve system with the intelligent device designed and implemented and tested it.

Development of Gas Detector Location Index Technique to Prevent Explosion Accidents of Offshore Plant (해양플랜트 폭발사고 방지를 위한 가스감지기 위치 선정 방법 연구)

  • Sohn, Jung Min;Paik, Jeom Kee;Kim, Sang Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.1
    • /
    • pp.63-70
    • /
    • 2017
  • Release of hazardous and flammable gas is a significant contributor to risk. The ignition of flammable gas clouds can lead to explosion accidents in the offshore installations. A gas detector, which is one of active protect systems, brings the module into a safe state through emergency shut down processes and reduces the damage by eliminating the dangerous releases. It is critical to understand the gas release, the wind field, and the complex geometry of installations to determine gas detector placement. In this paper, the Gas detector Location Index (GLI) which is a novel index for optimal detector location determination to efficiently prevent explosion accident using probabilistic approach.

Study on Prediction System Construction of Fire.Explosion Accident by NG & LPG among Domestic Gas Accidents (국내 가스 사고사례 중 NG 및 LPG의 가스 화재.폭발사고 예측시스템 구축에 관한 연구)

  • Ko Jae-Sun;Kim Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.48-55
    • /
    • 2006
  • In order to establish the comprehensively, quantitatively predictable program to the fire and explosion accidents in the urban gas system, and to set up domestic criteria of societal risk, the collected urban gas accident data have been deeply analyzed. The Poisson probability distribution functions with t=5 for the database of the gas accidents in recent 11 year shows that 'careless work-explosion-pipeline' item has the lowest frequency, whereas 'joint loosening & erosion-release-pipeline' item has the highest frequency. And thus the proper counteractions must be carried out. The further works requires setting up successive database on the fire and explosion accidents systematically to obtain reliable analyses.

  • PDF

Assessment of Gas Release Dispersion and Explosion in Pipeline (파이프라인에서의 가스누출 확산과 폭발 영향평가)

  • Jung In-Gu;Yoo Sang-Bin;Lee Su-Kyung;Kim Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.2
    • /
    • pp.61-69
    • /
    • 1998
  • The risk assessments for gas leak in underground pipeline are conducted about the explosion accident of AHYUN-DONG underground service-base on December, 1994(Gaussian gas, LNG) and the accident of TAEGU subway on April 1995(Heavy gas LPG). We have calculated the total mass of gas release and have respected the efficient of explosions with report of the spot. The dispersion zones of LNG were calculated as large as fifteen times to those of LPG by ALOHA. The effects of thermal radiation from LNG explosion were assumed less than that from LPG by PHAST.

  • PDF

A Study on Quantitative Risk Presentation of LNG Station (LNG충전시설의 위험도 표현에 관한 연구)

  • Ko, Jae-Wook;Yoo, Jin-Hwan;Kim, Bum-Su;Lee, Heon-Seok;Kim, Min-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • There are lots of energy facilities using gas(storage facility, compressed gas pipe, station, tank lorry) on the domestic. These major gas facilities cause major accidents associated with fire, explosion, toxic and etc. With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG (Liquefied Natural Gas) and CNG(Compressed Natural Gas) stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Buchen LPG (Liquefied Petroleum Gas) station, it is difficult to establish a new station. In this research, we present quantitative risk assessment for LCNG;LNG multi-station and compare it result against individual risk criteria of HSE.

  • PDF

Cases Study of Accidents in High Risk Organizations by System Dynamics (시스템 다이내믹스 기법을 활용한 고위험 조직 사고 사례 분석)

  • Oh, Youngmin;Ryu, Jin
    • Korean System Dynamics Review
    • /
    • v.16 no.3
    • /
    • pp.5-29
    • /
    • 2015
  • The importance of the concept of safety culture has increased in the security of high-risk facility after Chernobyl accident in 1986. This paper elaborated the concept of safety culture and its main factors by Causal Loop Diagram. Due to the decline of safety culture, the occurrence of incidents and accidents require more and more corrective actions to the members of high-risk facilities and thereby increasing their workloads. Employees who must complete the task within the given time have to have time pressures and don't comply with the rules and procedures. Also, a schedule pressure is a big stress for employees, causing mistakes in precision work. In order to improve these problems, CLD of the safety culture in this paper suggests hiring more workers, re-allocation of given workloads and strengthen the learning, communication capabilities and safety leadership. In addition, the two real accident cases were analyzed to test the feasibility of the System Dynamic simulation model through the process of structuring the fault trees on the stationary black out accident in Kori unit 1 in South Korea and Kleen Energy power station explosion in US. The simulation results show that the various safety factors cause the serious accident combined with mechanical failure and safety culture will reduce the possibility of the accidents in these high-risk organizations. This simulation model can contribute to analyzing the impact of the organizational and human factors of safety culture and can provide the alternatives in high-risk facilities.

A Study on Safety Guidelines for Hydrogen Refueling Stations at Expressway Service Area using Quantitative Risk Assessment (정량적 위험성 평가를 통한 고속도로 휴게소 수소 충전소 안전 가이드라인 연구)

  • KIM, HEE JIN;JANG, KYEONG MIN;KIM, SOO HYEON;KIM, GI BEOM;JUNG, EUN SANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.551-564
    • /
    • 2021
  • The use of clean energy based on the hydrogen economy is increasing rapidly due to the greenhouse gas reduction policies and the increase in the need for hydrogen. Currently, South Korea government have been considering a plan to construct hydrogen refueling stations at expressway service area for the purpose of supplying hydrogen vehicles. In the case of a hydrogen refueling stations, a quantitative risk assessment (QRA) must be performed because it includs and uses a high pressurized hydrogen storage tank. In this study, QRA was conducted using societal risk and F-N curve by the consequence assessment (CA) of jet fire and explosion according to the population density, capacity of the high pressurized hydrogen storage tank and frequency assessment (FA) data to the general hydrogen refueling stations systems in expressway service area. In the cases of jet with a leak diameter of 7.16 mm, regardless of expressway service area location, the societal risk was over 1E-04 that was acceptable for as Low As reasonably practicable (ALARP) region (workforce), but unacceptable for ALARP region (public). In the cases of gas explosion, all expressway service area satisfy ALARP region. In the case of the population density is over 0.0727, QRA for constructing the hydrogen refueling stations, must be conducted.