• Title/Summary/Keyword: Explosion proof

Search Result 78, Processing Time 0.02 seconds

Heat Dissipation of Sealed LED Light Fixtures Using Pulsating Heat Pipe Technology

  • Kim, Hyung-Tak;Park, Hae-Kyun;Bang, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.64-71
    • /
    • 2012
  • An efficient cooling system is an essential part of the electronic packaging such as a high-luminance LED lighting. A special technology, Pulsating Heat Pipe (PHP), can be applied to improve cooling of a sealed, explosion-proof LED light fixture. In this paper, the characteristics of the pulsating heat pipes in the imposed thermal boundary conditions of LED lightings were experimentally investigated and a PHP device that works free of alignment angle was investigated for cooling of explosion-proof LED lights. Five working fluids of ethanol, FC-72, R-123, water, and acetone were chosen for comparison. The experimental pulsating heat pipe was made of copper tubes of internal diameter of 2.1 mm, 26 turns. A variable heat source of electric heater and an array of cooling fins were attached to the pulsating heat pipe. For the alignment of the heating part at bottom, an optimum charging ratio (liquid fluid volume to total volume) was about 50% for most of the fluids and water showed the highest heat transfer performance. For the alignment of the heating part on top, however, only R-123 worked in an un-looped construction. This unique advantage of R-123 is attributed to its high vapor pressure gradient. Applying these findings, a cooling device for an explosion-proof type of LED light rated 30 W was constructed and tested successfully.

Experimental Study on Marine oil Skimmer Applying the Vapor Explosion-proof Equipment (유증기 방폭 장치를 적용한 해상 오일 유출 회수장치(Oil skimmer)에 대한 실험적 연구)

  • Ham, Seong-Hun;Jung, Chan-sub
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.105-109
    • /
    • 2015
  • In this paper is proposed for the oil return device developed to perform efficient emergency operation in the event the sea oil spill. Oil recovery apparatus for spilled oil on marine aims to quickly purged with high recovery. Oil recovery apparatus can prevent secondary pollution which may occur in the purification method using the adhesion agent and chemicals. Also it has excellent properties oil recovery. Adopted by the vapor explosion-proof mechanism to remove the risks that may occur during oil recovery operations.

Explosionproof Properties of High Strength Steel Fiber Reinforced Concrete with the Contents of Steel Fiber (섬유혼입율 변화에 따른 고강도 섬유보강 콘크리트의 방폭특성)

  • 이광설;안영준;박구병;김성수;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.303-306
    • /
    • 1999
  • For the purpose of Military means, explosion proof concrete, which protect the structures from the damage due to the explosion of bomb and maintain its shape, is required to develop. Therefore, in this paper, mechanical and explosionproof properties of concrete are tested under various steel fiber contents and member size. According to the experimental results, compressive, tensile and flexural strength go up with the increase of fiber contents. Energy bearing capacities is higher with the increase of fiber contents. Especially, it is confirmed that slurry infiltrated fiber concrete (SIFCON) gains in high strength and has high energy bearing capacities. SIFCON is expected to apply in the construction of explosion proof structures.

  • PDF

Valve monitoring system design and implementation using an infrared sensor and ZigBee (Zigbee와 적외선 센서를 활용한 밸브 개폐 모니터링 시스템 설계 및 구현)

  • Sim, Hyun;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.1
    • /
    • pp.73-80
    • /
    • 2015
  • The valve device is installed in hazardous areas, such as a chemical plant explosion has been sealed with fire protection device to prevent the risk of explosion. In this paper, due to the explosion-proof devices using external power the device can not be used in infrared sensors and Zigbee sensor valve device by measuring the open degree of valve opening and closing of the danger zone to check whether. Valve opening and closing operation log screen time, we propose a low-power operation monitoring system administrators to manage and control the plant. Develop power control relay board apply an improved algorithm to apply the asynchronous LPL power management. The plant monitoring system and explosion-proof valve opening and closing the valve system with the intelligent device designed and implemented and tested it.

Automation System of Explosion-Proof Panel Condition (방폭 패널 컨디션 자동화 시스템(1))

  • Hwang, Dae-Hyeon;Choi, Kwang-Il;Bae, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.253-258
    • /
    • 2020
  • Petrochemical industry complex in Korea always has high riskiness due to explosive and inflammable gases. To prevent these explosion, most facility of petrochemical industry complex requires the performance of explosive proof. The control panel, which is used as explosive proof, has been used the air injection method by manually from outside to constantly keep the temperature and pressure between inside and outside of the panel. In this paper, we propose the automatic temperature controller, which performs automatic heating and cooling according to temperature inside the panel in order to control temperature automatically.

Methodology Study of Design Related to Accidental Explosion of Simple Explosive Storage Facility (화약류 간이저장소의 우발적 폭발을 고려한 안전설계 방법 연구)

  • Jung-Gyu, Kim;Seung-Won, Jung;Jun-Ha, Kim;Byung-Hee, Choi
    • Explosives and Blasting
    • /
    • v.40 no.4
    • /
    • pp.1-14
    • /
    • 2022
  • To review the appropriateness of current regulations on the simple explosive storage facility, the effects of internal explosion on the structural stability of the standard storage facility were analyzed by means of both FEM analyses and field experiments. As a result, it was found that the explosion-proof performance of the existing storage structure was not sufficient for 15 kg of emulsion-type explosive. Thus, an alternative method of splitting explosives was tested by conducting sympathetic detonation experiments. This method worked properly as expected, and the proper amount of splitted explosive was determined according to the test results. In addition, a storage structure with open ceiling was found to be very effective because explosion pressure was released so rapidly that the damage of the facility could be reduced significantly. Hence, such a structural pattern was proposed as a new design scheme for simple explosive storage facility.

A Study for Development and Characteristics of Electrostatic Eliminator for Charged Particles (대전된 분체의 정전기제거장치 개발 및 특성에 관한 연구)

  • Jung, Yong-Chul;Kim, Joon-Sam;Lee, Dong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.22-30
    • /
    • 2006
  • On this study, we developed the electrostatic eliminator for charged particles in manufacturing process. The characteristics of the electrostatic eliminator were investigated, which is two kinds. The first one is Electrical Corona Discharged Type Ionizer. The second one is Photo Ionizer in using soft X-ray. From the experiment, we have obtained the following results. In case of Electrical Corona Discharged Ionizer, neutralization efficiency of charged particles were approximately saturated to 98% over 6.0kV, but as it is non-explosion proof, can not be used in flammable particle treatment process. While in case of photo Ionizer in using soft X-Ray, neutralization efficiency of charged particles were approximately 95%, and more its structure is explosion proof, could be used in flammable particle treatment process.

Design and evaluation of the thermal capability to secure a working time of cryogenic explosion-proof camera in LNG carrier tank

  • Kang, Geun-Il;Kwak, Si-Young;Park, Chun-Seong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.9 no.5
    • /
    • pp.568-576
    • /
    • 2017
  • With an increase in the usage of LNG, there is a heightened interest about its safety aspects regarding the explosion of LNG carrier tank. The need for a cryogenic explosion-proof camera has increased. The camera has to work in cryogenic environment (below $-160^{\circ}C$) in LNG carrier. This study conducted design and heat transfer analysis of cryogenic camera to secure working time in limitation of heat source. The design with gap width of double pane windows was conducted based on simple vertical cavity model to insulate from cryogenic environment. The optimal gap width was 12.5 mm. For effective analysis considering convection within the camera, equivalent thermal conductivity method was adopted with ABAQUS. The working time of the camera predicted was over 10 h at warm-start condition. In cold-start condition, it required about 5 h of pre-warming time to work. The results of analysis were compared with the ones of the actual cryogenic test.

A Study on the Design and Real-Time Implementation of Robust Sensor Monitoring Device in Explosion Proof Industrial Site (방폭 산업 현장에 강인한 센서 모니터링 장치 설계 및 실시간 구현에 대한 연구)

  • Jeong-Hyun Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.867-874
    • /
    • 2023
  • In this paper, a wireless communication-based sensor data monitoring device with an explosion-proof (Exd IIC) case was implemented to enable installation at explosion-risk industrial sites such as plants. In existing industrial plant sites, most of the temperature sensors and vibration and impact sensors are wired up to several kilometers, which takes a lot of time and money to bury long pipes and cables. In addition, there are not many cases where some wireless devices have been applied to actual plant industry sites due to communication quality problems. Therefore, in order to solve this problem, zigbee mesh wireless communication was applied to provide high reliability wireless communication quality to industrial plant sites, and the time and cost incurred in new or additional installation of sensors could be greatly reduced. In particular, in the event of loss or error of some wireless communication devices, the communication network is automatically bypassed or recovered to enable real-time data monitoring.