• Title/Summary/Keyword: Explosion prevention

Search Result 146, Processing Time 0.022 seconds

Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류 모니터링용 실시간 무선 원격 감시 시스템)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2729-2731
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. In this paper, results of development about Real-time Wireless Remote Monitoring System for Stray Current of Subway System are presented.

  • PDF

The Buried Type Reference Electrode for Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류의 실시간 무선 원격 감시 시스템용 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2732-2734
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development about the permanent buried type reference electrode($Cu/CuSO_4$) are presented.

  • PDF

The Development of Buried Type Reference Electrode Using Porous Ceramic(${\alpha}-Al_{2}O_{3}$) (다공성 세라믹(${\alpha}-Al_{2}O_{3}$)를 이용한 지중 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.145-147
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development of buried type reference electrode using porous ceramic$({\alpha}-Al_{2}O_{3})$ are presented.

  • PDF

Knowledge Modeling of Reliability Analysis and Safety Design for Offshore Safety Instrument System with MBSE (Model-Based Systems Engineering) (모델기반 시스템엔지니어링을 활용한 해양플랜트 안전시스템(SIS, Safety Instrumented System)의 신뢰도 분석 및 안전설계 지식 모델링)

  • Bae, Jeong-hoon;Jung, Min-jae;Shin, Sung-chul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.3
    • /
    • pp.222-235
    • /
    • 2018
  • The hydrocarbon gas leak in the offshore plant can cause large accidents and lead to significant damages to human, property and environment. For prevention of fire or explosion accidents from gas leak, a SIS(Safety Instrumented System) should be installed. In the early stage of the offshore design, required SIL(Safety Integrated Level) is determined and reliability analysis is performed to verify the design in reliability aspects. This study collected data, information related to reliability analysis and created knowledge model of safety design for the offshore system with MBSE(Model-Based Systems Engineering) concept. Knowledge model could support safety engineer's design tasks as the guidance of reliability analysis procedure of safety design and make good conversation with other engineers in yard, class, company, etc.

A Study on the Risk of Organic Solvents for Underground Area under Construction Site through a Fire Accident Case (화재사고사례를 통해서 본 건설현장 지하공간에서의 유기용제의 위험성에 대한 연구)

  • Ahn, Byung-Joon;Jung, Ki-Hyuk;Lee, Jung-Suk;Rhim, Jong-Kuk
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.9-17
    • /
    • 2018
  • In the consideration of the working conditions, which have several kinds of works operating at the same time, at construction sites, it is difficult to prevent industrial accidents. There are a number of works to employ flammable materials and hot works simultaneously operated without fire protection systems. It causes a huge fire and casualties. In this research to analyze an accident case, the reasonable prevention methods are suggested throughout the property tests for the organic solvents and the analysis of the behavior for vapour cloud in the underground area of the construction site.

A Study on Explosive Limits of Flammable Materials - Explosive Limits of Ternary System by Means of Solution Thermodynamics and MRSM Model - (가연성물질의 폭발한계에 관한 연구 - 용액열역학 및 MRSM 모델에 의한 3성분계 폭발한계 -)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.91-97
    • /
    • 2005
  • The research on the explosive limits is one of fundamental fields of combustion process, and information on the explosive limits of mixture of fuel and oxidant, with or without additives, is very important for the prevention in industrial fire and explosion accidents. Explosive limits of all compounds and solvent mixtures can be calculated with the appropriate use of the fundamental laws of Raoult, Batten, Le Chatelier and MRSM(modified response surface methodology) model. In this study, the reference values of lower explosive limits(LEL) of the ethanol+toluene+ethylacetate system were compared with the calculated values by using the solution thermodynamics and the MRSM model, respectively. The values calculated by the proposed equations were a good agreement with literature data within a few percent. By means of this methodology, it is possible to evaluate reliability of experimental data of the lower explosive limits of the flammable mixtures. Also, from given results, it is possible to predict explosive limits of the other flammable liquid mixtures used in the chemical process by the use of the proposed equations.

A Study on the Calculation of the Design Loads for Blast Doors of Underground Ammunition Facilities Using M&S (M&S를 통한 지하탄약고의 격실 방폭문 내폭력 산정 연구)

  • Park, Young Jun;Baek, Jonghyuk;Son, Kiyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.302-310
    • /
    • 2016
  • An underground ammunition facility requires less quantity distances than the aboveground counterpart. However, chamber blast doors which resist the high blast-pressures are necessary for prevention of the consecutive explosions when an accident explosion occurs at any chamber. This paper aims to propose an procedure for calculation of the design loads for the chamber blast doors. Modeling considerations are drawn through analyzing the influences of the geometrical shapes and mechanical properties of rocks on the propagation of pressure wave along with the tunnels. Additionally, the design loads for the chamber blast doors in a newly-built underground ammunition facility are calculated based on the proposed procedure.

Identifying Hazard of Fire Accidents in Domestic Manufacturing Industry Using Data Analytics (국내 제조업 화재사고 데이터 분석을 통한 복합 유해·위험요인 확인)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.23-31
    • /
    • 2023
  • Revising the Occupational Safety and Health Act led to enacting and revising related laws and systems, such as placing fire observers in hot workplaces. However, the operating standards in such cases are still ambiguous. Although fire accidents occur through multiple and multi-step factors, the hazards of fire accidents have been identified in this study as individual rather than interrelated factors. The aim has been to identify multiple factors of accidents, outlining fire and explosion accidents that recently occurred in the domestic manufacturing industry. First, major keywords were extracted through text mining. Then representative accident types were derived by combining the main keywords through the co-word network analysis to identify the hazards and their relationships. The representative fire accidents were identified as six types, and their major hazards were then addressed for improving safety measures using the identification of hazards in the "Risk Assessment" tool. It is found that various safety measures, such as professional fire observers' training and clear placement standards, are needed. This study will provide useful basic data for revising practical laws and guidelines for fire accident prevention, system supplementation, safety policy establishment, and future related research.

A Study on the Development of Self-Checklists for Small and Medium-Sized Chemical Industries (중소규모 화학업종을 위한 자율점검표 개발 연구)

  • Woo Sub Shim;Kyeong-Seok Oh
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.5
    • /
    • pp.757-763
    • /
    • 2023
  • Major industrial accidents in which workers die due to fires or explosions while working at chemical substance handling workplaces continue to occur. Among the major industrial accidents that occurred between 2005 and 2021, the accident status by work situation and equipment was analyzed. Through analysis, it was confirmed that storage, reaction, and piping facilities were the main causes of the accident, and a self-checklist for each facility was developed. Verification was conducted through the supply and use groups to evaluate the suitability of the use, duties, and items of the self-checklist. The user group showed higher satisfaction than the supplier group for all three suitability of use, job, and item. In particular, since the inspection items of the self-checklist were organized around the cause of the accident derived through the analysis of actual accident cases, the satisfaction level was high in all groups. It is expected that the self-checklist developed through this study will be useful not only for large companies but also for small and medium-sized chemical industries that lack professional manpower.

Comparison and Improvement of Domestic and Foreign Regulations for the Prevention of Suffocation Accidents (국외 질식재해 예방규정 비교를 통한 국내 규정 개선방안)

  • Lim, Dae Sung;Lee, Seung kil;Kim, Chi-Nyon;Cho, Kee Hong;Yi, Gwang Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.1
    • /
    • pp.83-93
    • /
    • 2021
  • Objectives: 'Confined space' was only defined in the Safety and Health Regulations as a place where oxygen deficiency and hydrogen sulfide must be dealt with at the time of the initial enactment (1982). The danger of fire and explosion were added in 2003. We will compare and review the regulations related to confined space work under the current safety and health rules alongside regulations in other countries and prepare a plan to improve the system through enhanced clarity and execution. Methods: In a comparison of systems for the prevention of suffocation in confined spaces in major countries (Germany, United States, Japan) different concepts of the definition of confined spaces in different countries apparently due to differences in each country's legal implementation system, accident analysis methods, the status of safety and health implementation in workplaces, the precautions against actual confined space work, and the definition of confined spaces were found to be not much different between Korea and the other foreign countries. Results: In the case of Germany and the United States, a confined space is defined as a contextual concept rather than a place, so more careful attention is needed from operators or enclosed space managers as it is often necessary to judge the actual workplace. In the case of Korea and Japan, the interior of the place is mainly defined as a place, especially in the case of Japan, which concentrates on oxygen deficiency and hydrogen sulfide poisoning. Conclusions: For measures to improve regulations on the prevention of suffocation accidents in Korea, I would like to propose three major measures to improve the system in the rules on domestic industrial safety and health standards. It is necessary to prepare and provide a guide to ensure that the 18 types of confined spaces currently defined as confined spaces are clearly understood by field management supervisors or workers.