• Title/Summary/Keyword: Explosion hazards

Search Result 112, Processing Time 0.026 seconds

Factors Associating Major Burn in Chemical Injury Patients due to Industrial Place Incident : A Retrospective study (산업장 화학 손상 환자에서 중증 화상에 영향을 미치는 요인)

  • Shin, Hee-Jun;Oh, Se-Kwang;Lee, Han-You
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.332-339
    • /
    • 2016
  • This study examined the intensity of the association of factors affecting major burns by statistical analysis for patients injured by the release of chemical hazards. A total of 446 patients were evaluated as chemical injury patients, who had visited the emergency room from 1/Jan/2010 to 31/Dec/2014. The major burn was used as a dependent variable representing the severity of chemical injury. A chi-square test (CST) and binary logistic regression test (BLRA) were used as the statistical analysis method for determining the association between major burns and the independent variables. In CST, female and their presence at an incident scene, multiple site injury were associated with major burn (p<0.05). In BLRA, the presence at an incident scene and spills (comparing explosion), discharge (comparing admission) were associated with major burns (p<0.05). In this study, the presence at an incident scene was the most significant factor concerning major burns. Furthermore, gender and injury number, exposure mechanism (spill comparing explosion), and disposition (discharge comparing admission) were also associated with major burns.

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

Measurement and Prediction of Flash Points of Acetic Acid-Formic Acid System using Cleveland Open Cup Apparatus (Cleveland 개방식 장치를 이용한 Acetic acid+Formic acid 계의 인화점 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.67-72
    • /
    • 2013
  • The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. The flash point is a major physical property used to analyse the fire and explosion hazards of a flammable liquid solution. The flash point data for pure components are easily available in several literature. But the flash points of the flammable binary solutions appear to be scarce in the literature. The objective of this study is to measure and estimate the flash point of acetic acid-formic acid system. Cleveland open cup tester was used to measure the flash point. The experimental data were compared with the values estimated by the Raoult's law and the optimization methods based on van Laar and Wilson equations. As a result, the estmated values by optimization methods were found to be better than those based on the Raoult's law.

A Study on Fire Protection of Chemical Plants Using FRA (Fire Risk Assessment) Method (FRA(Fire Risk Assessment)기법을 이용한 화학공장의 Fire Protection에 관한 연구)

  • Han, Seung-Hoon;Yoo, Byung-Tae;Tae, Chan-Ho;Chae, Chung Keun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.17-26
    • /
    • 2016
  • Chemical plants and oil gas refinery facilities are intrinsically vulnerable to industrial hazards, such as explosion or fire. Especially, the fire is extremely dangerous to facility structures and plant personnel because of direct flame, radiant heat and smoke. In addition, it has the ripple effect of destroying infra-structures and polluting the environment. In an effort to tackle these potential industrial risks, the procedure of FRA techniques in chemical plants were investigated. The main focus was put on the time variation of physical properties of the main building, i.e. control rooms, warehouses and electrical substations, from a direct flame contact and radiant heat. The deformation of a building due to fire was monitored and modeled with respect to time variable. A variety of case studies, domestic and abroad, was tested in the model to verify the FRA procedure. The developed model was proven to be highly effective to reduce the possible risks at chemical plants. An accurate accident frequency prediction and damage quantification was made by the developed model.

A Study on Flash Points of a Flammable Substancea - Focused on Prediction of Flash Points in Ternary System by Solution Theory - (가연성물질의 인화점에 관한 연구 -용액론에 의한 3성분계의 인화점 예측을 중심으로-)

  • 하동명;이수경
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.14-20
    • /
    • 2001
  • The flash points are one of the most important fundamental properties used to determine the potential for fire and explosion hazards of flammable substances. A classification of the flash points is important for the safe handling of flammable liquids which constitute the solvent mixtures. Basic to all flash points behavior are vapor pressure and explosive limits(lower explosive limit and upper explosive limit). The flash points of flammable solvent mixtures can be calculated with the appropriate use of the fundamental laws of Raoult, Dalton, Le Chatelier and activity coefficient models. In this study, the reference values of lower flash points were compared with the calculated values by using Raoult's law and MRSM(modified response surface methodology) model. The lower flash points were in agreement with the predicted by Raoult's law and MRSM model. By means of this methodology, it is possible to evaluate reliability of experimental data of the flash points of the flammable mixtures.

  • PDF

The Measurement of Lower Flash Point for tert-Pentanol+n-Decane System Using Tag Open-Cup Tester (Tag 개방식 장치를 이용한 tert-Pentanol+n-Decane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.41-46
    • /
    • 2012
  • The flash point the lowest temperature at which the concentration of vapor of the substance in the air reaches the lower flammability limit(LFL), and is one of the most important physical properties used to determine the potential for fire and explosion hazards of industrial materials. The most published flash point data was for pure components and the flash points of the binary solutions that have flammable components, appear to be scarce in the literature. In the present study, the flash points of tert-pentanol+n-decane system were measured by Tag open-cup tester. The measured data were compared with the values calculated by the Raoult's law and the optimization methods based on the Wilson and NRTL equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

A Study on Ignition Hazard Caused by Electrostatic Discharge of Gasoline Used in the Gas Station (주유소에서 사용하는 휘발유의 정전기 방전으로 인한 점화위험성에 관한 연구)

  • Moon, Kyoon-Tae;Chung, Jae-Hee;Mizuki, Yamaguma;Choi, Kwang-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.13-18
    • /
    • 2010
  • To investigate electrostatic ignition hazards of commercial gasoline used in the gas station, experiments were conducted dealing with the minimum ignition energy(MIE) of several kinds of gasoline under the various temperature. The conductivity of gasoline that was required for an accurate risk assessment as well as the MIE were also examined. The solvent ignitability apparatus which can heat up the inside of the vessels up to $210^{\circ}C$ was used in this study. Four kinds of premium gasoline and four kinds of regular gasoline, differing with respect to the companies, were used as test specimens. The following results were obtained: (1) all gasoline specimens were so sensitive that even an electrostatic discharge with a very low energy, such as about 0.5mJ, could ignite them. The ignitability of premium gasoline was constant irrespective of the companies. On the other hand, the ignitability of regular gasoline was variable depending on the company. (2) The MIE of all specimens depended markedly on the temperature; in other words, an increase in temperature decreases the ignition energy value. (3) The conductivity values of all specimens were low. Those must be taken into consideration in electrostatic risk assessment.

A Study on Flash Points and Fire Points of Acids Using Closed Cup and Open-cup Apparatus (밀폐식과 개방식 장치를 이용한 Acid류의 인화점과 연소점에 관한 연구)

  • Ha, Dong-Myeong;Han, Jong-Geun;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.29-34
    • /
    • 2006
  • The flash and fire point are the most important combustible properties used to determine the potential for the fire and explosion hazards of flammable material. The flash point is defined as the lowest temperature at which a flammable liquid gives off sufficient vapor to form an ignitable mixture with air near its surface or within a vessel. The fire point is the temperature of the flammable liquid at which there will be flaming combustion, sustained 5 seconds in response to the pilot flame. In this study, the flash points and fire points were measured to present raw data of the flammable risk assessment for acids, using Pensky-Martens Closed Cup(C.C.) apparatus (ASTM-D93) and Tag Open-cup (O.C.) apparatus(ASTM D 1310-86). The measured fire points were compared with the estimated values based on 1.11 times stoichiometric concentration. The values calculated by the proposed equation were in good agreement with measured values.

Combustion Characteristics of Ionized Fuels for Battery System Safety (배터리 시스템 안전을 위한 이온화 연료의 연소 특성)

  • Ko, Hyeok Ju;Lee, Eui Ju
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.22-27
    • /
    • 2018
  • Many electronic devices are powered by various rechargeable batteries such as lithium-ion recently, and occasionally the batteries undergo thermal runaway and cause fire, explosion, and other hazards. If a battery fire should occur in an electronic device of vehicle and aircraft cabin, it is important to quickly extinguish the fire and cool the batteries to minimize safety risks. Attempts to minimize these risks have been carried out by many researchers but the results have been still unsatisfied. Because most rechargeable batteries are operated on the ion state during charge and discharge of electricity and the combustion of ion state has big difference with normal combustion. Here we focused on the effect of ions including an electron during combustion process. The effects of an ionized fuel on the flame stability and the combustion products were experimentally investigated in the propane jet diffusion flames. The burner used in this experiment consisted of 7.5 mm diameter tube for fuel and the propane was ionized with th ionizer (SUNJE, SPN-11). The results show that toe overall flame stability and shape such as flame length has no significant difference even in the higher ion concentration. However the fuel ionization affects to the pollutant emissions such as NOx and soot. NOx and CO emissions measured in post flame region decreased by fuel ionization, especially high fuel velocity, i.e. high ion density. TGA analysis and morphology of soot by TEM indicates that the fuel ionization makes soot to be matured.

Prediction of the Detonation Limit of the Flammable Gas and Vapor (가연성가스와 증기의 폭굉한계 예측)

  • Ha, D.M.;Yoo, H.S.;Kang, S.H.;Park, D.J.;Jeong, J.Y.;Lee, M.H.;Choi, W.Y.;Han, S.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.131-134
    • /
    • 2008
  • In this study, the lower detonation limits(LDL) and the upper detonation limits(UDL) of the flammable substances predicted with the appropriate use of the heat of combustion and the stoichiometric coefficient. The values calculated by the proposed equations were a good agreement with literature data within a few percent. From a given results, It is to be hoped that this methodology will contribute to the estimation of the detonation limits of for other flammable substances.

  • PDF