• 제목/요약/키워드: Explosion Resistance

검색결과 106건 처리시간 0.024초

지중선로의 분포 온도 측정 시스템 개발 (Development of optical temperature distribution measurement system for Underground Power Transmission tunnel)

  • 이근양;송우성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.766-768
    • /
    • 1998
  • Optical Temperature Distribution measurement System (OTDS) is completely different from conventional electric point sensor in that it uses the optical fiber itself as the sensor. This new concept in temperature measuring system requires only one fiber to be laid. The use of optical fiber also gives the advantage of small diameter, light weight, explosion resistance, and electromagnetic noise resistance. The OTDS is a sensor which is capable of making a precise measurement over a wide range of areas using only a single optical fiber. Since current temperature sensors, such as the thermocouple, are only used to measure temperaturea of point, they are almost impractical for measuring a wider range because of the extremely high cost. In comparision with current sensors, the optical fiber distributed temperature sensor can make much quicker and more precise measurements at a comparatively low cost.

  • PDF

재유화형 폴리머를 혼입한 폴리머 시멘트 모르타르의 내화특성 (Fundamental Properties Polymer-Modified Mortars Using Re-dispersible Polymer Powder)

  • 장건영;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.35-41
    • /
    • 2019
  • In this study, the fire resistance performance of polymer cement mortars which are used as a representative repair material for section restoration, is evaluated and residual bond strength is measured by considering unity with concrete. According to the evaluation of fire resistance performance of re-emulsification type polymer cement mortars, residual compressive strength was drastically decreased according to heating temperatures with an increase of polymer addition rate, and this seems to be attributable to the application of polymer film. In addition, an explosion phenomenon occurred frequently with an increase of addition rate, so this should be considered when selecting repair materials and processing.

정전기 방전 평가를 위한 간이형 도구 개발에 관한 연구 (A Study on the Development of Simulating Tool for Evaluation of Electrostatic Discharge)

  • 최상원
    • 한국안전학회지
    • /
    • 제26권3호
    • /
    • pp.15-22
    • /
    • 2011
  • Explosion and fire cause about 30 reported industrial major accidents a year by ignition source which discharge of electrostatic generated to flammable gas, vapor, dust and mixtures. It brings economically and humanly very large loss that accident was caused by fire and explosion from electrostatic discharge. Thus, it is very important that electrostatic discharge energy is to be control below not to be igniting flammable mixtures. There are two kinds of analysis model for electrostatic discharge, human body model and machine model. Human body model is available the parameter of human's electrical equivalent that capacitance is 100 pF, resistance is $1.5k{\Omega}$. To simulate and visualize the electrostatic discharge from human body need a very expensive and high voltage simulator. In this paper, we measured the value of capacitance and resistance concerned with test materials and sizing of specimen and the value of charged voltage concerned with test specimen and distance to develop an electrostatic charge/discharge simulating tool for teaching with which concerned industrial employee and students. The result of experiments, we conformed that the minimum ignition energy of methane-oxygen mixtures meets well the equation $W=1/2CV^2$, and found out that the insulating material and sizing of equivalent value having human body mode are the poly ethylene of 200 mm and 300 mm of diameter. Developed electrostatic charge/discharge simulating tool has many merits; simple mechanism, low cost, no need of electric power and so on.

유기섬유를 혼입한 고강도 콘크리트의 폭렬 특성에 관한 실험적 연구 (A Study on the Spalling Properties of High Strength Concrete Using Synthetic Fiber)

  • 전찬기;전중규
    • 한국재난정보학회 논문집
    • /
    • 제8권1호
    • /
    • pp.18-26
    • /
    • 2012
  • 최근 건축구조물에 있어서 초고층화, 대형화의 요구에 의해 고강도 및 고성능 콘크리트의 사용이 증가하고 있다. 하지만 고강도 및 고성능 콘크리트는 화재 시 발생하는 폭렬현상에 취약한 문제가 있다. 폭렬은 화재 시 콘크리트 피복의 손실을 초래하여 내부콘크리트와 철근의 열전달률을 높여 콘크리트와 철근의 온도를 상승시키는 작용을 한다. 이러한 고강도 콘크리트의 화재 시 폭렬을 방지하기 위하여 많은 연구들이 진행되고 있으며, 대표적으로 폴리프로필렌(polypropylene)섬유, 강섬유를 콘크리트에 혼입한 연구들에 의해 폭렬제어성능이 입증되었으나, 섬유 혼입에 따른 유동성 저하 및 시공성 불량 등의 문제점이 제기되고 있다. 따라서 본 연구에서는 이와 같은 문제를 해결하기 위하여 에스테르계 윤활제 및 비이온성 계면활성제를 포함한 코팅액으로 코팅된 Polyamide 섬유를 콘크리트에 혼입하여 내화성능 및 시공성을 확보하였으며, 강도영역별 적정 조건을 실험을 통하여 도출하였다. 그 결과, 13mm의 polyamide 섬유 적용시 강도영역별로 60MPa에서는 $0.8kg/m^3$, 80MPa에서는 $1.0kg/m^3$, 100MPa는 $1.5kg/m^3$이상 혼입시 폭렬 제어 및 시공성 확보가 가능할 것으로 사료된다.

수치해석을 활용한 가스차단문의 폭발압력저항 성능평가 (Performance Evaluation on Blast-resistant of Gastight Door using Numerical Simulation)

  • 신배근;김지유;김의수
    • 한국가스학회지
    • /
    • 제26권1호
    • /
    • pp.27-33
    • /
    • 2022
  • 가스 취급 및 저장시설의 확충과 더불어 폭발의 규모가 다양해짐에 따라 사고를 대비한 방폭 설비 관련 연구가 활발하게 이루어지고 있다. 방폭 인증시험 대상 설비 중 하나인 가스차단문은 폭풍파나 내부 화재로 인한 팽창압력을 차단하는 동시에 내부의 인원과 장비를 보호하는 역할을 한다. 현재 사용되는 가스차단문은 방폭성능 인증시험 대상 설비임에도 방폭 설계 관련 규정이 명확히 제시되지 않고 있으며 해당 설비의 폭발압력저항성능평가에 관한 연구는 미비한 실정이다. 이에 본 연구에서는 미국재료시험협회(ASTM)에서 제시하는 가스차단문 규격에 관한 규정(ASTM F-1069-87, F-1068-90)을 참고하여 가스차단문을 3D 형상으로 모델링하고 ANSYS Explicit Dynamics 해석을 통해 기준 대비 가스차단문의 영구적 변형량을 비교하였다. 또한, 방폭 설비 관련 연구에서 사용되고 있는 회전연성도·변위연성도 계산을 통한 방폭성능 평가 방법을 함께 고려하여 가스차단문의 수치해석적 폭발압력저항 성능평가를 수행하였다.

Blast resistance of a ceramic-metal armour subjected to air explosion: A parametric study

  • Rezaei, Mohammad Javad;Gerdooei, Mahdi;Nosrati, Hasan Ghaforian
    • Structural Engineering and Mechanics
    • /
    • 제74권6호
    • /
    • pp.737-745
    • /
    • 2020
  • Nowadays, composite plates are widely used as high-strength structures to fabricate a dynamic loading-resistant armours. In this study, the shock load is applied by an explosion of spherical TNT charge at a specified distance from the circular composite plate. The composite plate contains a two-layer ceramic-metal armour and a poly-methyl methacrylate (PMMA) target layer. The dynamic behavior of the composite armour has been investigated by measuring the transferred effective stress and maximum deflection into the target layer. For this purpose, the simulation of the blast loading upon the composite structure was performed by using the load-blast enhanced (LBE) procedure in Ls-Dyna software. The effect of main process parameters such as the thickness of layers, and scaled distance has been examined on the specific stiffness of the structure using response surface method. After validating the results by comparing with the experimental results, the optimal values for these parameters along with the regression equations for transferred effective stress and displacement to the target have been obtained. Finally, the optimal values of input parameters have been specified to achieve minimum transferred stress and displacement, simultaneously with reducing the weight of the structure.

Effect of one way reinforced concrete slab characteristics on structural response under blast loading

  • Kee, Jung Hun;Park, Jong Yil;Seong, Joo Hyun
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.277-283
    • /
    • 2019
  • In evaluating explosion-protection capacity, safety distance is broadly accepted as the distance at which detonation of a given explosive causes acceptable structural damage. Safety distance can be calculated based on structural response under blast loading and damage criteria. For the applicability of the safety distance, the minimum required stand-off distance should be given when the explosive size is assumed. However, because of the nature of structures, structural details and material characteristics differ, which requires sensitivity analysis of the safety distance. This study examines the safety-distance sensitivity from structural and material property variations. For the safety-distance calculation, a blast analysis module based on the Kingery and Bulmash formula, a structural response module based on a Single Degree of Freedom model, and damage criteria based on a support rotation angle were prepared. Sensitivity analysis was conducted for the Reinforced Concrete one-way slab with different thicknesses, reinforcement ratios, reinforcement yield strengths, and concrete compressive strengths. It was shown that slab thickness has the most significant influence on both inertial force and flexure resistance, but the compressive strength of the concrete is not relevant.

화재 온도를 받는 고인성.고내화성 시멘트 복합체의 거동 (Behavior of Fire Resistance Engineered Cementitious Composites(FR-ECC) under Fire Temperature)

  • 한병찬;권영진;김재환
    • 콘크리트학회논문집
    • /
    • 제19권2호
    • /
    • pp.189-197
    • /
    • 2007
  • 터널 라이닝은 대형 화재 등과 같은 고온에 노출될 경우, 폭렬이 발생하고 이로 인해 급격한 온도 전달 및 내력 저하로 구조체 붕괴의 원인이 될 수 있다는 것이 여러 사례를 통해 보고되고 있다. 본 연구는 터널라이닝의 내화뿜칠 재료로 매우 적합할 것으로 판단되는 고인성 고내화성 시멘트 복합체(FR-ECC)를 개발하고 이의 역학적 특성 및 내화 성능을 평가하고자 하였다. 이를 위하여 FR-ECC에 있어서의 배합 요인을 실험 변수로 내화 시험을 실시하였으며 비정상 온도 분포 해석 기법(nonlinear transient heat flow analysis)을 이용하여 이를 해석적으로 묘사 검증되었다. 또한, 실험 결과를 통해 검증된 해석 기법을 이용하여 터널라이닝에 대한 열전달 해석을 수행하여 FR-ECC를 내화 2차 라이닝재로 이용하는 경우의 거동 특성을 분석하였다. 실험 결과 내화 성능을 향상시키기 위한 FR-ECC의 최적 배합은 PVA 섬유 또는 PP 섬유 혼입률 $V_f=2.0%$, 다공성 세라믹재 혼입률 $V_C=3.6%$, 공기량 $V_A=15%$로 나타났으며, 검증된 비정상 온도 분포 해석 기법을 이용하여 기존 터널에 40mm FR-ECC를 추가 라이닝 한 경우에 대한 해석 결과, 콘크리트 및 철근의 온도 분포가 모두 $350^{\circ}C$ 이내에서 제어되어 터널 내 콘크리트 및 철근에 대한 화재 피해를 방지할 수 있을 것으로 판단되었다.

열해석을 이용한 가스 실린더 캐비닛의 내화성능 최적설계 (Optimum Design on Fire Resistance of Gas Cylinder Cabinets using Thermal Analysis)

  • 남민서;김지유;김의수
    • 한국가스학회지
    • /
    • 제26권1호
    • /
    • pp.34-40
    • /
    • 2022
  • 특정 고압가스 등을 사용하기 위해 배관과 안전장치 등이 일체로 구성된 가스 실린더 캐비닛은 화재 발생 시 고온의 열로 인한 급격한 압력상승으로 실린더 폭발 및 파편 비산 등의 위험성을 가지고 있다. 이러한 위험성은 용기 내부에 충전된 가스의 유출을 초래하여 중독, 질식 등의 2차 피해를 발생시킬 가능성이 크므로 내부 용기로 인한 피해를 줄이기 위해서는 가스 실린더 캐비닛의 내화성능 확보가 매우 중요하다. 국외의 경우 가스 실린더 캐비닛이 화염에 노출되는 상황에서 일정 시간동안 내부의 실린더를 보호할 수 있도록 미국 NFPA code, 유럽 EN-14470-2 등에서 가스 실린더 캐비닛 내화시험 기준을 규정하고 있다. 하지만 국내의 경우 내압성능과 기밀성능 기준만 명시되어 있고, 그 대상은 배관계로 한정되어 있으며 국외보다 가스 실린더 캐비닛의 내화성능을 위한 연구 및 규정이 미흡한 실정이다. 이에 본 연구에서는 국내 가스 실린더 캐비닛의 내화성능 기준 확립을 위해 유한요소해석 프로그램인 ANSYS를 이용하여 열해석을 수행함으로써 화재 발생 시 구조, 재질 측면에서의 최적 조건을 도출하고자 한다.

HPFRCC, 분절 복합체 및 FRP를 활용한 구조물의 내폭 성능 향상 (Enhancing the Blast Resistance of Structures Using HPFRCC, Segmented Composites, and FRP Composites)

  • 윤영수;양준모;민경환;신현오
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.745-748
    • /
    • 2008
  • 과거 건설 구조물은 사용 하중을 견딜만한 성능과 사용성, 부식에 대한 저항성 정도만이 요구되었다. 그러나 9.11 사건 이후 이러한 관점은 바뀌어, 폭발에 의한 충격 하중 및 그와 동시에 발생할 수있는 화재로 인한 열에 견딜 수 있는 구조물의 저항 성능이 기본적인 요구 조건으로써 중요시되고있다. 전 세계가 연일 테러의 위협 아래 놓여있는 현 시점에서 구조물의 내폭 성능은 매우 중요한 부분이라 할 수 있다. 이에 본 연구에서는 기존의 건설 재료로써 폭넓게 사용되고 있는 시멘트 복합체 혹은 콘크리트에인장 강도 및 연성이 뛰어난 FRP composite을 결합시켜 내폭 성능이 우수하고 기존 구조물 및 신설구조물에 모두 시공이 가능한 최적화된 분절 복합체(Segmented Composite) 및 층 구조(Layered Structure)를 개발하고, 그 성능을 평가하고자 한다. 이러한 내폭 성능의 향상을 통해, 열과 충격 하중, 동하중 및 high strain에 의한 구조물의 붕괴를 줄이고 붕괴 시점을 보다 늦출 수 있다면, 이로인해 발생되는 인명 피해 및 경제적 손실을 최소화시킬 수 있을 것이다.

  • PDF