• 제목/요약/키워드: Experiments with Mixtures

검색결과 251건 처리시간 0.022초

이산화탄소/프로판 혼합냉매의 수평평활관 및 마이크로 핀관에서의 증발열전달에 관한 실험적 연구 (Experimental Studies on the Evaporative Heat Transfer Characteristics of CO2/Propane Refrigerant Mixtures in Horizontal Smooth and Micro-fin Tubes)

  • 조진민;김용진;김민수
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.290-299
    • /
    • 2008
  • Evaporation heat transfer characteristics of $CO_2$/propane mixtures in horizontal smooth and micro-fin tubes have been investigated by experiment. The experiments were carried out for several test conditions of mass fluxes, heat fluxes, compositions of $CO_2$/propane refrigerant mixtures and tube geometries. Direct heating method was used for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. Heat transfer coefficient data during evaporation process of $CO_2$/propane mixtures were measured for 5 m long smooth and micro-fin tubes with outer diameters of 5 mm, respectively. The tests were conducted at mass fluxes of 318 to 997 $kg/m^2s$, heat fluxes of 6 to 20 $kW/m^2$ and for several mixture compositions (100/0, 75/25, 50/50, 25/75, 100/0 by wt% of $CO_2$/propane). The differences of heat transfer characteristics between smooth and micro-fin tubes for various compositions of $CO_2$/propane refrigerant mixtures and the effect of mass flux, and heat flux on enhancement factor (EF) and penalty factor (PF) were presented.

평등전계에서 AC 및 표준 뇌 임펄스 전압의 $SF_6/CF_4$ 혼합 가스 절연 파괴 특성 (Breakdown Characteristics of $SF_6/CF_4$ Mixtures Under AC and Standard Lightning Impulse Voltages in Uniform Field)

  • 성허경;박신우;황청호;김남렬;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.227-228
    • /
    • 2007
  • Although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of SFJCF4 mixtures in uniform field was performed. The experiments were carried out under AC and standard lightning impulse (SLI) voltages. The sphere-sphere electrode whose gap distance was 1 mm was used in a test chamber. $SF_6/CF_4$ mixtures contained from 0 to 100% $SF_6$ and the experimental gas pressure ranged from 0.1 to 0.4 MPa. The results show that addition of $SF_6$ to $CF_4$ increase AC and SLI breakdown voltages. Under AC voltages the breakdown voltages of each mixture were linearly increased according to the quantity of $SF_6$. However under SLI voltages the breakdown voltages of each mixture were similar.

  • PDF

무시멘트 첨가제를 활용한 상온 재활용 아스팔트 혼합물의 성능 분석 (Performance Evaluation of Cold Recycled Asphalt Mixtures with Asphalt Emulsion and Inorganic Additives)

  • 박창규;김경수;김원재;이현종
    • 한국도로학회논문집
    • /
    • 제19권2호
    • /
    • pp.137-142
    • /
    • 2017
  • PURPOSES :The objective of this study is to evaluate the performance of asphalt mixtures containing inorganic additive and a high content of reclaimed asphalt pavement (RAP). METHODS : The laboratory tests verified the superior laboratory performance of inorganic additive compared to cement, in cold recycled asphalt mixtures. To investigate the moisture susceptibility of the specimens, tensile strength ratio (TSR) tests were performed. In addition, dynamic modulus test was conducted to evaluate the performance of cold recycled asphalt mixture. RESULTS :It was determined that NaOH solution mixed with $Na_2SiO_3$ in the ratio 75:10 provides optimum performance. Compared to Type B and C counterparts, Type A mixtures consisting of an inorganic additive performed better in the Indirect tensile strength test, tensile strength ratio test, and dynamic modulus test. CONCLUSIONS : The use of inorganic additive enhances the indirect strength and dynamic modulus performance of the asphalt mixture. However, additional experiments are to be conducted to improve the reliability of the result with respect to the effect of inorganic additive.

Experimental Designs for Computer Experiments and for Industrial Experiments with Model Unknown

  • Fang, Kai-Tai
    • Journal of the Korean Statistical Society
    • /
    • 제31권3호
    • /
    • pp.277-299
    • /
    • 2002
  • Most statistical designs, such as orthogonal designs and optimal designs, are based on a specific statistical model. It is very often that the experimenter does not completely know the underlying model between the response and the factors. In computer experiments, the underlying model is known, but too complicated. In this case we can treat the model as a black box, or model to be unknown. Both cases need a space filling design. The uniform design is one of space filling designs and seeks experimental points to be uniformly scattered on the domain. The uniform design can be used for computer experiments and also for industrial experiments when the underlying model is unknown. In this paper we shall introduce the theory and method of the uniform design and related data analysis and modelling methods. Applications of the uniform design to industry and other areas are discussed.

수평증발관내 R22/R114 혼합냉매의 열전달 특성에 관한 연구 (A Study for Evaporation Heat Transfer Characteristic of R22/Rl14 Refrigerant Mixtures in a Horizontal Tube)

  • 윤치한;이종인;하옥남
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.502-510
    • /
    • 2000
  • Evaporation heat transfer characteristics were studied in a horizontal tube using R22/R114 non-azotropic refrigerant mixture. the heat transfer coefficient was high in the upper part for pure refrigerants, and heat transfer coefficient was low in the lower part for refrigerant mixtures. In the low quality region where nucleate boiling was dominant, the average heat transfer coefficient was low. In the region where forced convection was dominant, heat transfer coefficient was high. Results show that the heat transfer coefficient for pure refrigerants obtained by experiments were lower than those of Yoshida et al. but agreed well with Jung et al., and Chen et al. data. But the heat transfer coefficients for refrigerant mixtures were lower about 20% than those predicted by the equation for pure refrigerant.

  • PDF

방향족 유기용매의 촉매산화공정에서 이성분계 혼합물의 속도특성 예측 (Kinetics Prediction of Binary Aromatic Solvent Mixtures in Catalytic Oxidation Process)

  • 이승범;윤용수;홍인권;이재동
    • 환경위생공학
    • /
    • 제16권1호
    • /
    • pp.66-71
    • /
    • 2001
  • The objective of this study was to depict the kinetic behavior of the platinum catalyst for the deep oxidation of aromatic solvents and their binary mixtures. The oxidation kinetics of aromatic solvents, which were benzene, toluene and m-xylene, was studied on a 0.5% $Pt/{\gamma}-Al_2O_3$ catalyst. Deep oxidation of binary mixtures, which were 1:1 in volume, was carried out and the inlet concentration was controlled in the range of 133 and 333ppmv. An approach based on the two-stage redox model was used to analysis the results. The deep oxidation conversion of aromatic solvents was inversely proportional to inlet concentration in plug flow reactor. This trend is due to the zeroth-order kinetics with respect to inlet concentration. The kinetic parameters of multicomponent model were independently evaluated from the single compound oxidation experiments. A simple multicomponent model based on two-stage redox rate model made reasonably good predictions of conversion over the range of parameters studied.

  • PDF

Selection of Variables for Response Surface Experiments with Mixtures

  • Park, Sung H.
    • Journal of the Korean Statistical Society
    • /
    • 제6권2호
    • /
    • pp.103-115
    • /
    • 1977
  • A strategy for selecting subsets of variables from a given linear model in a mixture system is discussed. The purpose is to achieve better fitting surfaces for estimation of the response in an experimental region of interest. A criterion is proposed for screening variables and illustrated with an example.

  • PDF

전기로 제강 환원 슬래그 혼합토의 지반공학적 특성 (Geotechnical Characteristics of Reduced Slag-soil Mixtures in Electric Furnace)

  • 신재원;윤여원;윤길림
    • 한국지반환경공학회 논문집
    • /
    • 제12권7호
    • /
    • pp.31-37
    • /
    • 2011
  • 철강의 생산 중에 부산물로 발생하는 전기로 제강 환원슬래그는 토질안정제로서의 적용성, 결합재 및 팽창재로서 활용법에 대한 약간의 연구 보고만 있을 뿐, 전기로 제강 환원슬래그 재활용에 관한 연구 및 시공실적은 거의 없는 실정이다. 본 연구는 전기로 제강 환원슬래그를 토목 분야에 재활용할 수 있는 방법을 모색하는데 이러한 목적을 달성하기 위하여 SEM, XRF 시험을 수행하였다. 이를 바탕으로 풍화토 및 점토와 환원슬래그를 일정한 혼합율로 혼합한 후, 환원슬래그 혼합토의 물리 공학적 특성을 고찰하기 위한 다양한 지반공학적 실내시험을 수행하였다. 다짐시험에서는 환원슬래그의 혼합율이 증가할수록 최대건조단위중량이 감소하고 최적함수비는 증가하였다. 이것은 환원슬래그를 성토재 및 재하재로 사용할 경우, 환원슬래그가 혼합된 풍화토는 지내력의 증가 등의 관점에서는 성토재 및 재하재로 적합하지 않음을 의미한다. 환원슬래그와 풍화토를 혼합한 환원슬래그 혼합토의 전단강도 특성은 일반적인 모래의 내부마찰각보다 약간 크거나 비슷하였고, 투수특성 또한 실트 또는 모래와 비슷한 결과를 확인하였다. 환원슬래그와 점토를 혼합한 환원슬래그 혼합토의 일축압축강도는 순수점토의 일축압축강도보다 크게 나타났고, 재령일수가 증가함에 따라 증가하는 경향을 보였다. 따라서 연약점토 지반의 표층개량에 적용할 경우 개량효과가 있을 것으로 판단된다.

수평 평활관내에서 비공비혼합냉매의 강제대류 증발열전달 (Forced Convective Evaporating Heat Transfer of Non-azeotropic Refrigerant Mixtures in a Horizontal Smoothed Tube)

  • 박기원;오후규
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.225-233
    • /
    • 1995
  • Experiments were performed to investigate the heat transfer characteristics of nonazeotropic mixture R-22+R-114 in a heat pump system. The ranges of parameter, such as heat flux, mass flow rate, and quality were $8,141{\sim}32,564W/m^2$, 24~58kg/h, and 0~1, respectively. The overall compositions of the mixtures were 50 and 100 per-cent of R-22 by weight for R-22+R-114 mixture. The results indicated that there were distinct different heat transfer phenomena between the pure substance and the mixture. In case of pure refrigerant the heat transfer rates for cooling were strongly dependent upon quality of the refrigerant. Overall evaporating heat transfer coefficients for the mixture were somewhat lower than pure R-22 values in the forced convective boiling region. For a given flow rate, the heat transfer coefficient at the circumferential tube wall(top, side, and bottom of the test tube) for R-22/R-114(50/50wt%)mixture, however, was higher than for pure R-22 at side and bottom of the tube. Furthermore, a prediction for the evaporating heat transfer coefficient of the mixtures was developed based on the method of Yoshida et.al.'s. The resulting correlation yielded a good agreement with the data for the refrigerant mixtures.

  • PDF

불평등 전계에서 SF6/N2 혼합가스의 AC 절연파괴전압 시뮬레이션 및 실험값와의 비교 (AC Breakdown Voltage Simulation of SF6/N2 Mixture in Non-Uniform Field and Its Comparison with Experimental Values)

  • 이병택;황청호;이태호;허창수;장용무
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1416-1422
    • /
    • 2010
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/N_2$ mixtures. At present study the breakdown characteristics of $SF_6/N_2$ mixtures in Non-uniform field was performed. In this paper, The simulation value are compared with experiment values. Streamer breakdown criterion was used for predicting breakdown voltage. For accurate simulation this simulation apply utilization factor using CST(computer simulation technology) EM $studio^{tm}$ program. AC breakdown experiments in non-uniform field was performed to compare with the breakdown simulation values. The pressure range of gas mixtures was 0.4 MPa to 0.7 MPa. The rod-plane was used and mixture ratio is $SF_6$ 20% : $N_2$ 80%. The gap lengths are 10mm to 70mm. As the pressure increase, this simulation value does not correspond to the experiment value. So this simulation need surface roughness factor. As a result of applying surface roughness factor this simulation decrease a relative error (|experiment value - simulation value| /simulation value).