• 제목/요약/키워드: Experiments and CFD analysis

검색결과 186건 처리시간 0.031초

화력발전소 순환수펌프 흡입관 주위에서의 유동특성에 관한 연구 (A study on the flow characteristics around a suction pipe of circulation water pump in thermal power plant)

  • 최성룡;안중현;문승재;이재헌;유호선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.201-204
    • /
    • 2008
  • Vortex and swirl occurring in a pump suction intake sump normally reduce the performance and disturb the safe operation of the circulation water pump in thermal power plants. This paper presents a case study of one particular intake sump design via a CFD analysis and a hydraulic model testing. The physical experiments and numerical analysis were performed under two flow and three level variation conditions. The vortex patterns around the pump suction pipe have been predicted by a commercial CFD code with the k-${\varepsilon}$ model. The model tests were conducted on a 1/10 model for a practical intake sump. The location, number and general pattern of the free surface vortex and submerged vortex predicted by CFD simulation were found to be a good agreement with those observed in the model testing.

  • PDF

CFD를 이용한 C-GIS의 열해석 (Thermal Analysis using CFD of Cubicle type Gas Insulated Switchgear)

  • 안희섭;홍두영;이한신;김영근;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.882-884
    • /
    • 2003
  • In this paper, thermal analysis of Cubicle type Gas Insulated Switchgear(C-GIS) was investigated through experiments and numerical analysis. To predict 3-dimensional temperature and velocity distribution, the commercial package was used. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF

전산유동 해석을 이용한 수동의 유동 균질성 평가 (Estimation of Flow Uniformity in Water Tunnel by Using CFD Analysis)

  • 임영택;장조원;김문상
    • 한국항공운항학회지
    • /
    • 제12권3호
    • /
    • pp.13-24
    • /
    • 2004
  • It is easier to view flow visualization by using a water tunnel rather than a smoke wind tunnel because of low speed at same Reynolds number. Using a water tunnel also produces more definite flow visualization by the use of various color dyes. The flow uniformity in test section is very significant for accuracy of the test because most flow experiments elicit results through the installation of a model in uniform flow. The purpose of small-size desktop-type water tunnel is not to produce quantitative measurements, but rather to give a visualization of the fluid flow phenomenon. However, uniformity in the test section affects the accuracy of the results. Accordingly, this research estimates uniformity in a water tunnel test section by using the commercially available CFD code FLUENT. Results of the CFD analysis show that the flow uniformity of the test section is good.

  • PDF

CFD-CAD 통합해석을 이용한 전력기기 온도상승 예측 (Prediction of temperature rise of Electric Switching Device Using CFD-CAD Integrated Analysis)

  • 안희섭;이종철;최종웅;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.808-810
    • /
    • 2002
  • Higher current-rating and improved thermal performance are being sought for existing medium-voltage vacuum circuit breakers(VCB) in order to meet market needs which require to be compact and downsized. In this paper, thermal performance of medium voltage vacuum circuit breaker was investigated through experiments and numerical analysis. We changed several major parameters of current-rating and heat sink affecting on thermal behaviors in the breaker and observed the results. To predict the temperature distribution in complex three-dimensional (3-D) VCB components and gas, the commercial package was used to simulate conjugate heat transfer. Although some assumptions and simplifications were introduced to simulate the model, results from the computational model were in good agreement with actual temperature rise measurements obtained from experiments.

  • PDF

전산유체역학 (CFD)을 이용한 PEMFC의 성능분석 (Performance Analysis of PEMFC Using Computational Flow Dynamics (CFD))

  • 김선회
    • 디지털융복합연구
    • /
    • 제11권8호
    • /
    • pp.199-204
    • /
    • 2013
  • 단순한 모델링이 아닌 3차원의 정밀한 모델링을 이용하여 연료전지 내부에서의 상황을 모사하였다. 자동차 엔진, 비행기 등의 설계에 있어서 실제 실험의 횟수를 줄여주기 위하여 매우 정밀한 전산유체역학(CFD)이 사용된다. 본 연구에서는 CD-ADAPCO사의 STAR-CD를 이용하여 고체고분자전해질형 연료전지(PEMFC)의 성능을 분석하였다. PEMFC 단위전지의 형상과 유로의 흐름의 변화에 따른 성능의 영향성을 분석하였다. 그 결과 rectangular cell 의 성능이 square cell 보다 높게 나타났으며 유체흐름의 방향은 성능에 큰 영향을 미치지 못했다. 또한 공기의 과잉률에 따른 전체적인 연료전지의 성능을 비교하였으며, 또한 PEMFC 내부에서의 전류밀도의 분포에 관한 분석을 실시하여 그 결과를 비교, 분석하였다. 그 결과 flip-flow의 경우가 co-flow의 경우에 비하여 최대치와 최고치의 값의 편차가 작은 것으로 확인되어 보다 균일한 분포를 가지는 것을 확인할 수 있었다.

전산유체해석을 이용한 축류펌프의 성능예측 (Prediction of Axial Pump Performance Using CFD Analysis)

  • 김민환;김종인;박진석
    • 한국전산유체공학회지
    • /
    • 제6권1호
    • /
    • pp.14-20
    • /
    • 2001
  • The CFD analysis of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump was performed. Not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicted the experimental head value. In the range of the higher flow rates, the results were also in very good agreement with the experimental data, not only in absolute value but also in term of slope. Although experimental data to be compared were not available in the range of the lower flow rates, the results well described the S-shape performance curve of the axial pump characteristic.

  • PDF

무창 육성.비육돈사의 공기유동 특성 분석 (Analysis of Airflow Characteristics in an Enclosed Growing-Finishing Pig House)

  • 송준익;최홍림;최희철;이덕수;전병수;전중환;유용희
    • 한국축산시설환경학회지
    • /
    • 제14권1호
    • /
    • pp.39-46
    • /
    • 2008
  • 본 실험은 무창육성 비육돈사에 있어서 여름과 겨울철 환기를 할 때 공기 유입구에서의 공기속도가 환경에 미치는 영향을 조사하고자 CFD를 이용한 모델을 설정하였고, 현장실험을 통한 결과와 CFD 모델의 공기유속 결과를 서로 비교하였다. 공기속도에 있어서 수학적인 모델은 현장실험 결과와 매우 유사하게 나타났다. 환기시스템에서의 공기흐름은 양쪽 측벽 슬롯 판넬을 통하여 공급하였으며 겨울철은 $2{\sim}2.5m/s$ 였고, 여름철은 0.8 m/s 전후였다. 이상의 연구 결과 여름철과 겨울철 모두 해석 Model과 실험 무창육성 비육돈사내 측정 결과 평균 유속은 근소한 차이로 나타나 공기유동 해석 연구에 있어서 CFD 시뮬레이션의 적용으로 합리적인 결과를 도출할 수 있음을 확인하였다.

  • PDF

CFD 해석을 이용한 실내 온도 최적 측정 위치 선정 방법 (Optimal Measuring Point Selection Method of Indoor Temperature using CFD Analysis)

  • 이민구;정경권
    • 한국정보통신학회논문지
    • /
    • 제16권7호
    • /
    • pp.1559-1566
    • /
    • 2012
  • 본 논문에서는 실거주 환경과 같이 구축된 테스트베드에 온도 센서를 설치하여 최적의 온도 측정 위치를 설정하는 방법을 제안한다. 테스트베드를 CFD(Computational Fluid Dynamics) 방법으로 온도 변화를 시뮬레이션하고, 온도 변화와 기류 변화를 확인하여 최적 온도 측정 위치를 선정한다. 디자인빌더 소프트웨어를 이용하여 테스트베드를 3차원 모델링을 하고 CFD를 실행하였다. 최적위치는 바닥에서 높이 1.5m이고, 온도 변화가 적은 곳을 선택하였다. 실제 공간에 30개의 온습도센서를 설치하여 실험을 진행하였고 온도변화 결과를 확인하였다.

곡관 연결 조건에 따른 디젤엔진 매연여과장치 입구 유속 분포의 CFD 해석 (A CFD Analysis of Flow Velocity at Inlet of a Diesel Particulate Filter according to the Curved Duct Connection Conditions)

  • 이수룡;고영남;이충훈
    • 한국철도학회논문집
    • /
    • 제12권4호
    • /
    • pp.457-464
    • /
    • 2009
  • 디젤 엔진 매연 필터의 입구부와 배출 가스 배출을 위한 배기관 연결을 직선 또는 곡선으로 형태로 연결하였을 때의 DPF 입구 유속 분포를 $STAR-CD^{(R)}$ 전산해석 프로그램을 사용하여 시뮬레이션하였다. 곡관의 형상을 나타내는 3 종류의 수치해석 용 격자 모델을 사용하여 DPF 입구에서의 유속 분포를 시뮬레이션 하였다. 피토관을 2차원 이송장치에 탑재하고 위치를 이동시키며 측정한 유속 분포와 동일한 조건에서 시뮬레이션한 결과와 비교하였다. DPF 입구와 $90^{\circ}$의 곡관이 연결된 조건에서 CFD 해석을 수행한 결과 입구 단면에서의 유속 분포가 말발굽 형태를 나타내었으며 최대 유속값이 DPF 중심축에서 약간 벗어난 위치에서 나타나고 있다. 이러한 CFD 해석결과는 실험 결과와 비교적 잘 일치하였다.

풍자원 평가를 위한 건축물 주변의 유동특성 (Characteristic of Wind Flow around Building Structures for Wind Resource Assessment)

  • 조강표;정승환;신승화
    • 한국유체기계학회 논문집
    • /
    • 제14권3호
    • /
    • pp.50-58
    • /
    • 2011
  • To utilize wind resources effectively around buildings in urban area, the magnitudes of wind velocity and turbulence intensity are important, which means the need of the information about the relationship between the magnitude of wind velocity and that of fluctuating wind velocity. In the paper, wind-tunnel experiments were performed to provide the information about Characteristic of Wind flow around buildings with the spanwise distance and the side ratio of buildings as variables. For a single building with the side ratios of one and two, the average velocity ratio was 1.4 and the velocity standard deviation ratio ranged from 1.4 to 2.6 at the height of 0.02m at the corner of the windward side, in which flow separation occurred. For twin buildings with the side ratios of one and two, the velocity ratio ranged from 2 to 2.5 as the spanwise distance varied at the height of 0.02m, and the velocity standard deviation ratio varied near 1.25. For twin buildings with the side ratios of one and two, the maximum velocity ratio was 1.75 at the height of 0.6m, and the maximum velocity standard deviation ratio was 2.1. It was also found from the results of CFD analysis and wind-tunnel experiments that for twin buildings with the side ratios of one and two, the difference between the velocity ratio of CFD analysis and that of wind-tunnel experiments at streamwise distances was near 0.75.