• Title/Summary/Keyword: Experimental point of View

Search Result 487, Processing Time 0.022 seconds

Numerical and experimental study on the scale effect of internal solitary wave loads on spar platforms

  • Wang, Xu;Zhou, Ji-Fu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.569-577
    • /
    • 2020
  • Based on laboratory experiments and numerical simulations, the scale effect of Internal Solitary Wave (ISW) loads on spar platforms is investigated. First, the waveforms, loads, and torques on the spar model at a laboratory obtained by the experiments and simulations agree well with each other. Then, a prototype spar platform is simulated numerically to elucidate the scale effect. The scale effect for the horizontal forces is significant owing to the viscosity effect, whereas it is insignificant and can be neglected for the vertical forces. From the similarity point of view, the Froude number was the same for the scaled model and its prototype, while the Reynolds number increased significantly. The results show that the Morison equation with the same set of drag and inertia coefficients is not applicable to estimate the ISW loads for both the prototype and laboratory scale model. The coefficients should be modified to account for the scale effect. In conclusion, the dimensionless vertical forces on experimental models can be applied to the prototype, but the dimensionless horizontal forces of the experimental model are larger than those of the prototype, which will lead to overestimation of the horizontal force of the prototype if direct conversion is implemented.

Experimental and Computational Study on Separation Control Performance of Synthetic Jets with Circular Exit

  • Kim, Minhee;Lee, Byunghyun;Lee, Junhee;Kim, Chongam
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.296-314
    • /
    • 2016
  • This paper presents experimental and computational investigations of synthetic jets with a circular exit for improving flow control performance. First, the flow feature and vortex structure of a multiple serial circular exit were numerically analyzed from the view point of flow control effect under a cross flow condition. In order to improve separation control performance, experimental and numerical studies were conducted according to several key parameters, such as hole diameter, hole gap, the number of hole, jet array, and phase difference. Experiments were carried out in a quiescent condition and a forced separated flow condition using piezoelectrically driven synthetic jets. Jet characteristics were compared by measuring velocity profiles and pressure distributions. The interaction of synthetic jets with a freestream was examined by analyzing vortical structure characteristics. For separation control performance, separated flow over an airfoil at high angles of attack was employed and the flow control performance of the proposed synthetic jet was verified by measuring aerodynamic coefficient. The circular exit with a suitable hole parameter provides stable and persistent jet vortices that do beneficially affect separation control. This demonstrates the flow control performance of circular exit array could be remarkably improved by applying a set of suitable hole parameters.

Pulse Density Modulated Zero Voltage Soft-Switching High-Frequency Inverter with Single Switch for Xenon Gas Dielectric Barrier Discharge Lamp Dimming

  • Sugimura, Hisayuki;Suh, Ki-Young;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.391-394
    • /
    • 2006
  • This paper presents soft switching zero voltage switching high frequency inverter for rare gas fluorescent lamp using dielectric-barrier discharge phenomenon. The simple high-frequency inverter can completely achieve stable zero voltage soft switching (ZVS) commutation for wide its output power regulation ranges and load variations under its constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operating principle is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZVS operation commutation, together with its output effective power regulation characteristics-based on the high frequency PDM strategy. The experimental operating performances of this high frequency Inverter are illustrated as compared with computer simulation results and experimental ones. Its light dimming characteristics due to power regulation scheme are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliance implemented here is proven from the practical point of view.

  • PDF

A Study on the Properties and the Applying method of the HWANGTO GUDUL in View of an Environmental Ecological House (환경생태주택의 관점에서 본 황토구들의 일반적 특성과 적용)

  • Kim, June-Bong;Rhee, Shin-Ho;Yeo, Min;Jang, Moon-Ki
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.63-70
    • /
    • 2002
  • This study aims to provide the fundamental date of HUANGTO GUDUL for applying to current house heating system. It has been used as a traditional heating system in Korea for a long time and disappeared in the course of industrialization in Korea last a few decades and these days is tend to be widely adopted as house heating system. Even though it is known that the traditional heating system of HUANGTO GUDUL is good for ecological environment house and a kind of the natural friendly heating system for optimum residential heating environment, there are few systematic researches and analysed data of it. In order to analyse the characteristics of HUANGTO GUDUL, the existing materials of it's historical change was studied. And the architectural prospects of the use of GUDUL on the point of view of environmental ecology. The data of relationship between the mechanic properties and the workability of GUDUL materials and the environmental index such as the heating environment, relative humidity, and deodorization ratio and so on. And the heating effectiveness of GUDUL was compared with existing modem materials by experimental analysis. The results stated above can be grafted architecture and will be offered the optimum heating environment.

A Study on the Characteristics of Expression of Time-Space Concept in Media Art (미디어 아트에 나타난 시공간 개념의 표현 특성에 관한 연구)

  • Seo, Kyoung-Won;Lim, Kyung-Ran
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.347-356
    • /
    • 2007
  • The concept of time-space to be seen in the modem society has complex features at the points of scientific, philosophical, artistic, religious point of view. It has been brought up at a points of neo centric religious, philosophical view and then after, phenomenal approach and scientific approach were rendered through Newton and Einstein and so many scholar approaches affected the artistic field significantly. With such visual expression, it has affected the paintings for a long time till the 19th century, and then has affected various fields such as photography, film, video, computer, architecture and has currently affected the various space expressive of our daily lives and virtual space of digital. This study is to extract a visual and expressionistic characteristic through historical examination and multi-scholar analysis of time-space concept. Especially, by expanding the previous time and space concept, experimental cases and expressionistic characteristics has come up on the media art that offers various experience and by analyzing the expressionistic characteristics of the time-space concept expressed in media art, it is to extract the basic factors for the diversity of space experience.

A Study on Smoke Movement in Room Fires with Various Pool Fire Location

  • Jeong, Jin-Yong;Ryou, Hong-Sun
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1485-1496
    • /
    • 2002
  • In order to investigate the fire-induced smoke movement in a three-dimensional room with an open door, numerical and experimental study was performed. The center, wall, and corner fire plumes for various sized fires were studied experimentally in a rectangular pool fire using methanol as a fuel. The numerical results from a self-developed SMEP (Smoke Movement Estimating Program) field model were compared with experimental results obtained in this and from literature. Comparisons of SMEP and experimental results have shown reasonable agreement. As the fire strength became larger for the center fires, the air mass flow rate in the door, average hot layer temperature, flame angle and mean flame height were observed to increase but the doorway-neutral-planeheight and the steady-state time were observed to decrease. Also as the wall effect became larger in room fires, the hot layer temperature, mean flame height, doorway-neutral-planeheight and steady-state time were observed to increase. In the egress point of view considering the smoke filling time and the early spread of plume in the room space, the results of the center fire appeared to be more dangerous as compared with the wall and the corner fire. Thus it is necessary to consider the wall effect as an important factor in designing efficient fire protection systems.

The Experimental Study on Performance Improvement under frost conditions of the Heat Pump with Corrugate Shaped Fin and Two Compressors (저 착상 휜과 두 대 압축기 사이클을 이용한 히트펌프 난방성능 개선에 관한 연구)

  • Hwang Yoon-Jei;Cho Eun-Jun;Chung Baik-Young;Lee Gam-gue
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.201-208
    • /
    • 2005
  • This study presents the experimental study on improvement of frost/defrost performance in an heat pump system with newly developed fin and multiple compressors. As multiple compressors system, the variable and single speed compressor combinations has been introduced and compared with single speed 1-compressor system in a view point of improvement of frost/defrost performance. Also, newly developed corrugate shaped fin has been compared with conventional louver shaped fin. The frost/defrost performance is defined and some parameters are compared to discuss the effect of each combination. From this experimental study, it is known that if the variable and single speed compressor combination system equipped with corrugate shaped fin, the system performance has greatly improved not only for heating capacity, but also for frost performance.

A Study on the Characteristics of the Flow around a Sunken Vessel (침선어초 주위의 유동특성에 관한 연구)

  • 양찬규;김현주
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.9-16
    • /
    • 2000
  • This paper deals with the numerical and experimental study on the characteristics of the flow around a sunken vessel. Numerical simulation of the two dimensional steady flow on the midship section are carried out by the CFD code which is developed by using finite volume method and which includes the standard $textsc{k}$-$\varepsilon$ model with standard wall function. A experimental study is also carried out for the 1/100 scale model in circulating water channel. A velocity fields around the ship are measuremed by using particle image velocimetry technique. And the fluid forces acting on the ship hull by uniform current are measured by two axis load cell. The computed and measured velocity fields on the midship section are compared with each other in the view point of velocity dstribution and reattachement length, which shows good agreement in quality. The drag force on the vessel also showed the same tendency in both computational and experimental results. However, the quantitative disagreements are shown due to the three dimensional effect of the experiment. The result are used to determine the functional efficiency and stability of the vessel as a artificial reef.

  • PDF

Video Augmentation by Image-based Rendering

  • Seo, Yong-Duek;Kim, Seung-Jin;Sang, Hong-Ki
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1998.06b
    • /
    • pp.147-153
    • /
    • 1998
  • This paper provides a method for video augmentation using image interpolation. In computer graphics or augmented reality, 3D information of a model object is necessary to generate 2D views of the model, which are then inserted into or overlayed on environmental views or real video frames. However, we do not require any three dimensional model but images of the model object at some locations to render views according to the motion of video camera which is calculated by an SFM algorithm using point matches under weak-perspective (scaled-orthographic) projection model. Thus, a linear view interpolation algorithm is applied rather than a 3D ray-tracing method to get a view of the model at different viewpoints from model views. In order to get novel views in a way that agrees with the camera motion the camera coordinate system is embedded into model coordinate system at initialization time on the basis of 3D information recovered from video images and model views, respectively. During the sequence, motion parameters from video frames are used to compute interpolation parameters, and rendered model views are overlayed on corresponding video frames. Experimental results for real video frames and model views are given. Finally, discussion on the limitations of the method and subjects for future research are provided.

  • PDF

Electrowetting of a droplet under an AC Electric Fields (교류전압 하에서의 액적의 전기습윤현상)

  • Hong, Jin-Seok;Ko, Sung-Hee;Kang, Kwan-Hyung;Kang, In-Seok
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.175-176
    • /
    • 2006
  • Electrowetting is prevailing for its various applicability on lap-on-a-chip, and MEMS devices, such as a pump, lens, micro-actuator in the micro-TAS technology. In the usual electrowetting, an AC power is preferred to DC practically. The AC electric field delays the contact angle-saturation, decreases the hysterisis, and is more stable in the view point of dielectric strength. But researches for AC electric field on electrowetting have not been reported very much yet. The different effect of AC on the electrowetting system, especially the effect of a frequency needs to be understood more concretely. In this work, the usual system for electrowetting, water droplet on the dielectric coated electrode (EWOD) is analyzed. Experimental study on the response of contact angles on input frequencies is performed. The simple circuit-model for EWOD system is considered to explain the experimental results. For more concrete understanding, the system is analyzed numerically, where simple AC-conduction model is used. Wetting tensions are analyzed under various input frequency to excavate the experimental results for the responses of the system on input frequencies.