• Title/Summary/Keyword: Experimental measurements

Search Result 2,965, Processing Time 0.038 seconds

A COMPARATIVE STUDY OF THE PROBING ATTACHMENT LEVEL, RADIOGRAPHIC AND SURGICAL MEASUREMENT ACCORDING TO GINGIVAL INFLAMMATORY CONDITION (치은 염증 상태에 따른 치주낭 측정 깊이와 방사선학적 측정 깊이, 외과적 측정 깊이의 비교 연구)

  • Baik, Dong-Hoon;Chai, Jung-Kiu;Cho, Kyoo-Sung;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.24 no.2
    • /
    • pp.261-270
    • /
    • 1994
  • The purpose of this study was to evaluate relationship of probing attachment levels, radiographic measurements and surgical measurements according to gingival inflammatory condition. Patients with incipient to moderate periodontitis were selected. Upper and lower premolar and molar teeth excluding third molars were measured. At first visit, gingival index and bleeding on probing were taken, and subjects were grouped into 4 categories as follows : Experimental group I : gingival index 1 and no bleeding on probing. Experimental group II : gingival index 2 and no bleeding on probing absent. Experimental group III : gingival index 1 and bleeding on probing present. Experimental group IV : gingival index 2 and bleeding on probing present. Probing attachment levels were measured with manual probe on mesial and distal surfaces from cementoenamel junctions to terminal ends of probe. Radiographic measurements were made to assess bone loss by measuring the distance from cementoenamel junction to the alveolar crest. After thorough scating, a flap was raised exposing the alveolar bone and surgical measurements were made from cementoenamel junction to alveolar bone. The results were as follows: 1. Differences between probing attachment level and radiographic measurements showed $1.01{\pm}0.73mm$ for experimental group I, $0.98{\pm}0.48mm$ for experimental group II, $0.59{\pm}0.66mm$ for experimental group III, $0.98{\pm}0.38mm$ for experimental group IV and with no significant difference between groups. 2. Differences between probing attachment level and surgical measurements showed $1.36{\pm}0.80mm$ for experimental group I, $1.47{\pm}0.54mm$ for experimental group II, $1.06{\pm}0.39mm$ for experimental group III, $1.41{\pm}0.40mm$ for experimental group IV and with no significant difference between groups. 3. Differences between surgical and radiographic measurements showed $0.36{\pm}0.48mm$ for experimental group I, $0.51{\pm}0.54mm$ for experimental group II, $0.57{\pm}0.72mm$ for experimental group III, $0.41{\pm}0.49mm$ for experimental group IV and with significant difference between experimental group I and experimental group II, III, IV(P<0.05).

  • PDF

Uncertainty Analysis of Flow Measurements of Seom River Experimental Watershed (섬강시험유역의 유량측정에 대반 불확실도 해석)

  • Choi Hung Sik;Cho Min Sok;Kim Sang Ho;Park Jung Soo
    • KCID journal
    • /
    • v.11 no.2
    • /
    • pp.47-54
    • /
    • 2004
  • The flow measurements have been .carried out without the evaluation for data accuracy. For the reliable data acquisition, the experimental watershed has been operated and the uncertainty analysis for flow measurements and the developed rating curves are i

  • PDF

Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring (직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석)

  • Istook, Cynthia L.;Lim, Ho-Sun;Chun, Jong-Suk
    • The Research Journal of the Costume Culture
    • /
    • v.19 no.6
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

Experimental validation of smartphones for measuring human-induced loads

  • Chen, Jun;Tan, Huan;Pan, Ziye
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.625-642
    • /
    • 2016
  • The rapid technology developments in smartphones have created a significant opportunity for their use in structural live load measurements. This paper presents extensive experiments conducted in two stages to investigate this opportunity. Shaking table tests were carried out in the first stage using selected popular smartphones to measure the sinusoidal waves of various frequencies, the sinusoidal sweeping, and earthquake waves. Comparison between smartphone measurements and real inputs showed that the smartphones used in this study gave reliable measurements for harmonic waves in both time and frequency domains. For complex waves, smartphone measurements should be used with caution. In the second stage, three-dimensional motion capture technology was employed to explore the capacity of smartphones for measuring the movement of individuals in walking, bouncing and jumping activities. In these tests, reflective markers were attached to the test subject. The markers' trajectories were recorded by the motion capture system and were taken as references. The smartphone measurements agreed well with the references when the phone was properly fixed. Encouraged by these experimental validation results, smartphones were attached to moving participants of this study. The phones measured the acceleration near the center-of-mass of his or her body. The human-induced loads were then reconstructed by the acceleration measurements in conjunction with a biomechanical model. Satisfactory agreement between the reconstructed forces and that measured by a force plate was observed in several instances, clearly demonstrating the capability of smartphones to accurately assist in obtaining human-induced load measurements.

2.5 Inch HDD Spindle Vibration with Flexible Base Plate

  • Heo, Bae-Kho
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.210-214
    • /
    • 2005
  • The purpose of this paper is to study the effects of the flexibility of HDD base plates on spindle vibration via theoretical predictions and experimental measurements. The flexibility of the base plate can significantly affect HDD spindle vibration. This is the most prominent feature in 2.5 inch HDD. Nevertheless, theoretical analysis of the spindle vibration often neglects the flexibility of the non-rotating part including spindle, base plate, and top cover. Our theoretical model developed in University of Washington can include the flexibilities of spindle and base plate. As a result, our theoretical prediction generally agrees well with our experimental measurements in vibration analysis. Moreover, Because of its small form factor, industrial practice is to use flanged disks instead of regular disks in vibration testing of prototypes. Our experimental measurements indicate that flanged disks and regular disks have very different behavior when the frequency is above 1 KHz.

  • PDF

2.5 Inch HDD Spindle Vibration with a Flexible Base Plate

  • Heo, Baek-Ho
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.111-116
    • /
    • 2006
  • The purpose of this paper is to study the effects of the flexibility of HDD base plates on spindle vibration via theoretical predictions and experimental measurements. The flexibility of the base plate can significantly affect HDD spindle vibration. This is the most prominent feature in 2.5 inch HDD. Nevertheless, theoretical analysis of the spindle vibration often neglects the flexibility of the non-rotating part including spindle, base plate, and top cover. Our theoretical model developed in University of Washington can include the flexibilities of spindle and base plate. As a result, our theoretical prediction generally agrees well with our experimental measurements in vibration analysis. Moreover, because of its small form factor, industrial practice is to use flanged disks instead of regular disks in vibration testing of prototypes. Our experimental measurements indicate that flanged disks and regular disks have very different behavior when the frequency is above 1 KHz.

  • PDF

Men's Work Clothes Jumper Pattern-making and Its Appearance Evaluation through 3-D Clothing Simulation (3차원 가상착의 시뮬레이션을 이용한 20~50대 연령별 남성 작업복 점퍼 패턴 설계 및 외관평가)

  • Park, Gin-Ah;Lee, Woo-Kyoung
    • Journal of Fashion Business
    • /
    • v.16 no.1
    • /
    • pp.103-120
    • /
    • 2012
  • The study aimed to evaluate the appearance of the men's work clothes jumpers developed to suggest the prototype work clothes jumper patterns by using the 3-D clothing simulation technology. The 3-D simulated clothing images considered the upper body features of men in the age range between 20 and 59 in South Korea. A questionnaire survey conducted previously suggested a basic jumper style with shirt collar and snap opening cuffs for the heavy industry workers; and discomforting parts of the work clothes jumper of the subject workers have been referred to for the experimental jumper appearance test. Besides, defining the measurements of men's upper bodies enabled to generate the men's 3-D virtual models representing each age group's average body feature. The significant body measurement factors for men's 3-D body modeling and jumper pattern-making were stature for the height factor; chest, waist and hip circumferences for the circumference factor; waist back, hip and arm lengths and interscye front/back for the length factor; and back neck breadth for the breadth factor and armscye and scye depths for the depth factor. The men's body measurements of 30's were implemented to three experimental jumper pattern-making methods, i.e. the 1st method using the relations based on stature and chest circumference; the 2nd method using the direct body measurements; and the 3rd method adopting the maximum ease amount of given body measurements whether relations or direct measurements except the direct measurement of scye depth. A comparison among the three experimental jumpers' simulated images highlighted that the appropriate ease amount of the jumper gained higher scores in terms of the jumpers' front, side, back and sleeve parts and the total silhouettes. Therefore the 3rd experimental jumper was finally selected for the heavy industry workers.

Experimental and theoretical study of BF3 detector response for thermal neutrons in reflecting materials

  • Nasir, Rubina;Aziz, Faiza;Mirza, Sikander M.;Mirza, Nasir M.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.439-445
    • /
    • 2018
  • Experimental measurements of the response of $BF_3$ detector to a 3 Ci Am-Be neutron source for three different reflecting materials, i.e., aluminum, wood, and Perspex of varying thicknesses have been carried out. The varying contribution of wall effect to the response due to change in active volume of the detector has also been determined experimentally. Then, a Monte Carlo code has been developed for the calculation of the neutron response function of the $BF_3$ detector using source biasing and importance sampling. This code simulates the $BF_3$ detector response exposed to the neutron field in a three-dimensional source, detector, and reflecting medium configurations. The results of simulation have been compared with the corresponding experimental measurements and are found to be in good agreement. The experimental neutron albedo measurements for various values of Perspex thickness show saturating behavior, and results agree very well with the data obtained by Monte Carlo simulation.

Effect of Spiral Elastic Band on Gait Function in Patients with Chronic Stroke

  • Baek, Ki hyun;Lim, Hyoung won
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.4
    • /
    • pp.169-175
    • /
    • 2019
  • Purpose: This study examined the effects of a spiral elastic band for the walking function on patients with chronic stroke. Methods: Twenty one chronic stroke patients were recruited and divided randomly into the experimental group and control group. Both groups performed mat exercises and gait training three times a week for four weeks, and gait training was applied to the experimental group with additional spinal elastic bands. Results: The results of this research were as follows. The 10MWT measurements showed that the velocities within and between the groups decreased significantly, and the results of TUG showed significant decreases in velocities after the interventions in both the control group and experimental group. On the other hand, there were no significant differences between the control and experimental group. The FRT measurements showed significantly increased stride lengths within and between the groups. The measurements of the stride length, stride velocity, cadence, and step length showed significant improvement within the groups, but there was no significant difference between the groups. The measurement of stance showed that the non-paralytic patients had a significant increase in the rates within the groups and a significant difference was observed between the groups. Conclusion: Spiral elastic bands are an effective intervention method for rehabilitation programs to enhance the walking function in the clinical field. A treatment needs to be developed for patients with walking problems due to various disorders by investigating the action mechanism of spiral elastic bands.

A comparison of condyle in malocclusion patients using 3D program

  • Jeon, Eun-Young;Park, Jong-Tae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2019.05a
    • /
    • pp.275-276
    • /
    • 2019
  • The purpose of this study was to assess condylar size in volumetric 3D imaging in patients with class I, class II, class III malocclusions. To evaluate the differences among the three experimental groups, the condylar values of men were analyzed. There was a significant difference in the measured values of height. Among the three experimental groups, the condylar measurements in women showed significant differences in height and width. This study is expected to be used for determining the connection between malocclusion and condyle as a base line data.

  • PDF