• Title/Summary/Keyword: Experimental measurement

Search Result 5,407, Processing Time 0.029 seconds

Characteristic analysis of mortar using desulfurization gypsum and carbon dioxide conversion capture materials as a cement admixture (탈황석고와 탄산화물을 혼합재로 사용한 모르타르의 특성 분석)

  • Hye-Jin Yu;Sung-Kwan Seo;Yong-Sik Chu;Keum-Dan Park
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.34 no.3
    • /
    • pp.86-91
    • /
    • 2024
  • In this study, the characteristics of mortar using carbondioxide conversion capture materials (CCMs), fabricated by reacting CO2 with desulfurization gypsum (DG) by-produced from a oil refinery, as a cement mixture. Based on the chemical component and particle size analysis results, it estimated that desulfurized gypsum reacted with carbon dioxide to produce carbonate crystals such as CaCO3. Using CCMs as a cement mixture, physical property and durability analysis were conducted by measuring such as workability, compressive strength, compressive strength ratio after freezing-thawing and accelerated carbonation depth. The experimental results showed that as the content of the admixture increased, workability and compressive strength characteristics decreased. Compressive strength after freezing-thawing and accelerated carbonation depth also showed similar characteristics to the physical property measurement results. In addition, compared to desulfurized gypsum, using CCMs showed better physical properties and durability. This was assumed to be due to differences in the crystal phases of the mixed materials such as free-CaO and CaCO3.

Histological Validation of Cardiovascular Magnetic Resonance T1 Mapping for Assessing the Evolution of Myocardial Injury in Myocardial Infarction: An Experimental Study

  • Lu Zhang;Zhi-gang Yang;Huayan Xu;Meng-xi Yang;Rong Xu;Lin Chen;Ran Sun;Tianyu Miao;Jichun Zhao;Xiaoyue Zhou;Chuan Fu;Yingkun Guo
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1294-1304
    • /
    • 2020
  • Objective: To determine whether T1 mapping could monitor the dynamic changes of injury in myocardial infarction (MI) and be histologically validated. Materials and Methods: In 22 pigs, MI was induced by ligating the left anterior descending artery and they underwent serial cardiovascular magnetic resonance examinations with modified Look-Locker inversion T1 mapping and extracellular volume (ECV) computation in acute (within 24 hours, n = 22), subacute (7 days, n = 13), and chronic (3 months, n = 7) phases of MI. Masson's trichrome staining was performed for histological ECV calculation. Myocardial native T1 and ECV were obtained by region of interest measurement in infarcted, peri-infarct, and remote myocardium. Results: Native T1 and ECV in peri-infarct myocardium differed from remote myocardium in acute (1181 ± 62 ms vs. 1113 ± 64 ms, p = 0.002; 24 ± 4% vs. 19 ± 4%, p = 0.031) and subacute phases (1264 ± 41 ms vs. 1171 ± 56 ms, p < 0.001; 27 ± 4% vs. 22 ± 2%, p = 0.009) but not in chronic phase (1157 ± 57 ms vs. 1120 ± 54 ms, p = 0.934; 23 ± 2% vs. 20 ± 1%, p = 0.109). From acute to chronic MI, infarcted native T1 peaked in subacute phase (1275 ± 63 ms vs. 1637 ± 123 ms vs. 1471 ± 98 ms, p < 0.001), while ECV progressively increased with time (35 ± 7% vs. 46 ± 6% vs. 52 ± 4%, p < 0.001). Native T1 correlated well with histological findings (R2 = 0.65 to 0.89, all p < 0.001) so did ECV (R2 = 0.73 to 0.94, all p < 0.001). Conclusion: T1 mapping allows the quantitative assessment of injury in MI and the noninvasive monitoring of tissue injury evolution, which correlates well with histological findings.

A Study on Design and Analysis of Module Control Method for Extended Use of Rechargeable Batteries in Mobile Devices (모바일 장치의 충전식 배터리 사용 연장을 위한 모듈 제어 방법 설계와 해석 연구)

  • Dohyeong Kim;jihoon Ryu;JinPyo Jo;JeongHo Kim
    • Journal of Platform Technology
    • /
    • v.12 no.2
    • /
    • pp.34-44
    • /
    • 2024
  • This paper proposes a dynamic clock supply control algorithm and a system load power stabilization algorithm that minimizes the power consumption of the sensing system, which accounts for the largest percentage of power consumption in mobile devices, to extend the usage time of the rechargeable battery mounted on the mobile device. The dynamic clock supply control algorithm can reduce the power consumed by the sensing system by configuring a circuit to cut off the power of the sensing system and by recognizing the state of low sensor change and adjusting the measurement cycle. The system load power stabilization algorithm is an algorithm that controls the power of the surrounding module according to the power consumption state, and when it requires a lot of power, it controls the clock supply to stabilize the operation. The experimental results confirmed that applying only the dynamic clock supply control algorithm reduces the power consumed by the sensing system by 17%, and applying only the system load power stabilization algorithm reduces power consumption by 9.3%, enabling it to operate stably in situations that require a lot of power such as image processing. When both algorithms were applied, the power consumption of the battery was reduced by 67% compared to before applying the algorithm. Through this, the reliability of the proposed method was confirmed.

  • PDF

Open-ended Coaxial Probe Technique for the Dielectric Characterization of Propylene Carbonate, Dimethyl Carbonate and Their Mixtures from 0.1 to 8 GHz at 288.15, 298.15, and 308.15 K (개방 단말 동축선을 활용한 프로필렌 카보네이트, 디메틸 카보네이트 및 이들의 이성분계 혼합물의 유전 이완 측정과 해석)

  • Hyo Jung Kim;Seung-Wan Song;Tae Jun Yoon
    • Clean Technology
    • /
    • v.30 no.3
    • /
    • pp.228-238
    • /
    • 2024
  • Electrolytes are one of the essential components of a lithium-ion battery. They determine the battery's lifespan and cell characteristics. The dielectric constant is a key thermophysical property for determining how much salt can be dissociated and solvated in a solution. Hence, fast and reliable dielectric constant measurement is essential when formulating an electrolyte solution. This work implemented an open-ended coaxial probe (OECP) station as a quick and reliable tool to measure the complex permittivity spectra of electrolyte solutions. The capability of the OECP station was tested by measuring the complex permittivity of propylene carbonate (PC), dimethyl carbonate (DMC), and their mixtures from 0.1 to 8 GHz at 288.15, 298.15, and 308.15 K. The obtained dielectric spectra were then interpreted based on dielectric relaxation models and thermodynamic theories. The measured static dielectric constant data agreed well with the data from previous studies. They were also correlated using the Wang-Anderko thermodynamic model, showing approximately a 1% deviation from the experimental data. In addition, the relaxation characteristics, including the relaxation time and the Cole-Davidson exponent, showed that the microstructure of the solution significantly changes at the propylene carbonate mole fraction of 0.4. These results and methodologies are expected to contribute to the further understanding of electrolyte solutions and ultimately lead to the optimization of electrolyte formulation for lithium-ion batteries.

Correlation Study of Carbonation Analysis Methods for Cement Paste with Fly Ash (플라이애시가 혼입된 시멘트 페이스트의 탄산화 분석방법에 따른 상관관계 연구)

  • Eun-A Seo;Ho-Jae Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.5
    • /
    • pp.54-61
    • /
    • 2024
  • This study conducted accelerated carbonation experiments on cement pastes using OPC and FA. It derived the correlation of pH prediction methods through component analysis of the carbonated pastes. Analysis of weight change due to thermal decomposition was performed using TG-DTA, and component analysis was conducted using XRF. A comparative review of each experimental result and pH measurement result was carried out. The study proposed a correlation analysis method between the component ratio of CO2 and CaO, the component ratio of calcium carbonate and calcium hydroxide, and pH. By analyzing the relationship between the CO2 components measured by XRF and pH, the correlation coefficients of all mixtures were 0.84 or higher, indicating a strong correlation.The correlation analysis of calcium carbonate and calcium hydroxide with pH using TG-DTA showed that the correlation coefficient for calcium carbonate was more than 0.86 for all formulations. However, the correlation coefficient between calcium hydroxide and pH was low, so a study was conducted to analyze the correlation with pH using the ratio of the results of the two components.

Characteristics of Titanium Dioxide-Impregnated Fibrous Activated Carbon and Its Application for Odorous Pollutant (이산화티타늄 담지 섬유형 활성탄소의 특성 및 악취오염물질 제어를 위한 응용)

  • Jo, Wan-Kuen;Hwang, Eun-Song;Yang, Sung-Bong
    • Clean Technology
    • /
    • v.17 no.1
    • /
    • pp.48-55
    • /
    • 2011
  • The application of fibrous activated carbon (FAC)-titanium dioxide ($TiO_2$) hybrid system has not been reported yet for the control of malodorous dimethyl sulfide (DMS) at residential environmental levels. Accordingly, the current study was designed not only to characterize this hybrid system using x-ray diffraction method, particulate surface measurement and Fourier transform Infrared (FTIR) method, but also to evaluate its adsorptional photocatalytic activity (APA) for the DMS removal. The physical/surface characteristics of FAC-$TiO_2$ which was prepared in this study suggested that the hybrid material might have certain APA for DMS. The Brunauer-Emmett-Teller (BET) specific area, total pore volume, micropore volume and mesopore volume decreased all as the $TiO_2$ amounts coated on FAC increased, whereas the reverse was true for average pore diameter. $TiO_2$ coated onto FAC did not influence the adsorptional activity of FAC for the DMS input concentration of 0.5 ppm. The APA test of the hybrid material presented that the initial removal efficiencies of DMS were 93, 78, 71 and 57% for the flow rates of 0.5, 1.0, l.5 and 2.0 L/min, respectively, and they decreased somewhat 2 h after the experiment started and kept almost constant for the rest experimental period. Under this pseudo-equilibrium condition, the DMS removal efficiencies were 78, 58, 53 and 36% for the four flow rates, respectively. Meanwhile, there were no significant byproducts observed on the surfaces of the hybrid material. Consequently, this study suggests that, under the experimental conditions used in the present study, the hybrid material can be applied for DMS at residential environment levels without being interfered by any byproducts.

The Influence of Landscape Pavements on the WBGT of Outdoor Spaces without Ventilation or Shade at Summer Midday (조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 영향 - 통풍과 차광이 배제된 하절기 주간의 조건에서 -)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.1-8
    • /
    • 2010
  • The purpose of the study was to evaluate the influence of landscaping pavements on WBGT(Wet-Bulb Globe Temperature) of outdoor spaces that lack ventilation and shade at summer midday. The relative humidity(RH), dry-bulb temperature(DT) and globe temperature(GT) were recorded every minute from June to October 2009 at a height of 1.2m above ten experimental beds with different pavements, by a measuring system consisting of an electric humidity sensor(GHM-15), resistance temperature detector(RTD, Pt-100), standard black globe(${\phi} 150mm$) and data acquisition systems(National Instrument's Labview and Compact FieldPoint). Additionally, the surface dry-bulb temperatures also were recorded and compared. The area of each experimental bed was 1.5m(W)${\times}$2.0m(L) and ten different kinds of pavement were used including grass, grass+cubic stone, grass+porous brick, brick, stone panels, cubic stone, interlocking blocks, clay brick, naked soil, gravel and concrete. To prevent interference from ventilation, a 1.5m height cubic steel frame was established around each bed and each vertical side of the frame was covered with transparent polyethylene film. Based on the records of the hottest period from noon to 3 PM on 26 days with a peak dry-bulb temperature over $30^{\circ}C$ at natural condition, the wet-bulb temperature(WT) and WBGT were calculated and compared. The major findings were as follows: 1. The average surface DT was $40.1^{\circ}C$, which is $9^{\circ}C$ higher than that of the natural condition. The surface DT of the pavements with grass were higher than those of concrete and interlocking block. The peak DT of the surface almost every pavement rose to above $50^{\circ}C$ during the hottest time. 2. The averages of DT, WT and GT were $40.1^{\circ}C$, $27.5^{\circ}C$ and $49.1^{\circ}C$, and the peak values rose to $48.1^{\circ}C$, $45.8^{\circ}C$ and $59.5^{\circ}C$, respectively. In spite of slight differences that resulted according to pavements, no coherent differentiating factor could be found. 3. The average WBGT of grass was the highest at $34.3^{\circ}C$ while the others were similar in the range of around $33{\pm}1^{\circ}C$. Meanwhile, the peak WBGT was highest with stone panel at $47.9^{\circ}C$. Though there were some differences according to pavements, and while grass seemed to be worst in terms of WBGT, it seems difficult to say ablolutely that grass was the worst because the measurement was conducted without ventilation and shade during summer daytime hours only, which had temperatures that rose to a dangerous degree(above $45^{\circ}C$ WBGT), withering the grass during the hottest period. The average WBGT resulted also showed that the thermal environment of the pavement without ventilation and shade were at an intolerable level for humans regardless of the pavement type. In summary, the results of this study show that ventilation and shade are more important factor than pavement type in terms of outdoor thermal comfort in summer daylight hours.

Measurement of Terminal Velocity for Scatter Prevention of Powder in the Voloxidizer for Oxidation of UO$_{2}$ Pellet (UO$_{2}$ 펠릿 산화로의 분말 비산 방지를 위한 최종속도 측정)

  • Kim Young-Hwan;Yoon Ji-Sup;Jung Jae-Hoo;Jin Jae-Hyun;Hong Dong-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.77-84
    • /
    • 2005
  • A voloxidizer for a hot cell demonstration, that handles spent fuels of a high radiation level in a limited space should be small and spent fuel powders should not be dispersed out of the equipment involved. In this study a density rate equation as well as the Stokes'equation has been proposed in order to obtain the theoretical terminal velocity of powders. The terminal velocity of U$_{3}$O$_{8}$ has been predicted by using the terminal velocity of SiO$_{2}$, and then determination has been the optimum air flow rate which is able to prevent powders from scattering. An equation which has shown a relationship between theoretical terminal velocities of U$_{3}$O$_{8}$ and SiO$_{2}$ has been derived with the help of the Stokes'equation, and then an experimental verification made for the theoretical Stokes' equation of SiO$_{2}$ by means of an experimental device made of acryl. The theoretical terminal velocity based on the proposed density rate equation has been verified by detecting U$_{3}$O$_{8}$ powders in a filter installed in the mock-up voloxidizer. As the results, the optimum air flow rates seem to be 20 LPM by the Stokes'equation while they are 14.5 L/min by the density rate equation. At the experiments with the mock-up voloxidizer, a trace amount of U$_{3}$O$_{8}$ seems to be detectable at the air flow rate of 14.5 L/min by the density rate equation, but U$_{3}$O$_{8}$ powders of 7$\mu$m diameter seem detectable at the air flow rate of 20 L/min by the Stokes'equation. It is revealed that 14.5 L/min is the optimum air flowe rate which is capable of preventing U$_{3}$O$_{8}$ powders from scattering in the UO$_{2}$ voloxidizer and the proposed density rate equation is proper to calculate the terminal velocity of U$_{3}$O$_{8}$ powders.

  • PDF

Antioxidant Effect of Arthrospira platensis Extract and Effect on UVB-induced Free Radical Production (Arthrospira platensis 추출물의 항산화 및 UVB에 의해 유도된 활성산소 생성에 미치는 영향)

  • Kim, Min Seung;Yang, Jae-Chan;Kim, Bo-Ae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.153-161
    • /
    • 2020
  • Arthrospira platensis is the oldest marine microalgae on the planet, is said to contain most of the nutrients needed by the human body. It's components are reported to contain a large amount of various substances such as phycocyanin, chlorophyll and β-carotene, and are known to have an aging and whitening effect. In this study, UVB-induced reactive oxygen species reduction efficacy and antioxidant activity of spirulina purified water extract were investigated. effect was confirmed by measuring DPPH radical scavenging activity, FRAP reducing power and ABTS+ radical scavenging activity of 0.05, 0.10, 0.50 1.0 mg/mL of spirulina purified water extract. The coagulation rate, hatching rate and heart rate toxicity were measured by treating spirulina purified water extract with 0.05, 0.10, 0.50 mg/mL concentration using Zebrafish, an alternative experimental animal model. UVB-induced ROS measurement was treated with spirulina extract at 0.05, 0.10, 0.50 mg/mL concentration, and then stained with DCFH-DA to confirm the inhibitory effect of ROS. As a result of measuring antioxidant effect, DPPH, FRAP and ABTS+ showed concentration-dependent antioxidant effects in comparison with ascorbic acid. and measuring the coagulation rate, hatching rate, and heart rate using Zebrafish, an alternative experimental animal, it was confirmed that there was no toxicity in 0.05 and 0.10 mg/mL except 0.5 mg/mL compared to the control group. The ROS scavenging activity of UVB-induced zebrafish showed higher ROS reduction than the positive control. The results of this study suggest that spirulina and purified water extracts are valuable for UV and skin protection cosmetics.

The effects of Moxibustion Therapy on Chronic Low Back Pain, Daily Living Disability and Sleep Pattern in Elderly Women (뜸요법이 여성노인의 만성요통, 일상생활기능장애 및 수면양상에 미치는 효과)

  • Kim, Hye-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.301-310
    • /
    • 2016
  • This is a nonequivalent control group non-synchronized experiment research to verify the effect of moxibustion therapy on efficient management of daily living disabilities and sleep patterns in elderly women with chronic low back pain. Total 12 sessions of moxibustion therapy were applied to elderly women(30 subjects in an experimental group and 30 subjects in a control group) in G City once a week for 12 weeks from March 15th to May $31^{st}$ 2015. Then the follow-up study was conducted 2 weeks after the post survey. For moxibustion, was applied to Shen-shu, Ashi point, Ta chang shu, Yang kuan and Yosu. 5 sheets of moxibustion were applied to 7 acupuncture points of Mugeukboyang moxibustion; Zu san li & Chu chi, Chung wan, Chung chi & Shui tao, Fei shu, Kao hung and Tien shu, Wijung respectively and experimental treatment was conducted. For assessing the degree of back pain, Visual Analog Scale(VAS) developed by Scott & Huskisson(1979) was used and for measuring the degree of daily living disability, Oswestry Disability Index, which was developed by Fairbank et al(1980) and translated and revised by Yim, Hyeon-sul et al.(1998), was used. For measuring sleep patterns, the sleep pattern measurement tool developed by Oh, Jin-su, Song, Mi-soon and Kim, Sin-mi(1998) was used. For data analysis, SPSS/WIN 18.0 was employed and Chi-square test, t-test and repeated measures ANOVA were performed. There were significant differences in pain score(F=2510.32, p<.001), daily living disability score(F=1937.82, p<.001) and sleep pattern score((F=15.54, p<.001) of elderly women that were provided with moxibustion therapy, compared to the control group. Therefore, it was found that moxibustion therapy made a positive contribution to reduction in pain and daily living disabilities and improvement in sleep quality. Based on this study finding, there is a need to apply moxibustion therapy to elderly people with chronic low back pain as a nursing intervention in future.