• 제목/요약/키워드: Experimental bias

검색결과 428건 처리시간 0.022초

Effect of Bias Magnetic Field on Magnetoelectric Characteristics in Magnetostrictive/Piezoelectric Laminate Composites

  • Chen, Lei;Luo, Yulin
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.347-352
    • /
    • 2015
  • The magnetoelectric (ME) characteristics for Terfenol-D/PZT laminate composite dependence on bias magnetic field is investigated. At low frequency, ME response is determined by the piezomagnetic coefficient $d_{33,m}$ and the elastic compliance $s_{33}^H$ of magnetostrictive material, $d_{33,m}$ and $s_{33}^H$ for Terfenol-D are inherently nonlinear and dependent on $H_{dc}$, leading to the influence of $H_{dc}$ on low-frequency ME voltage coefficient. At resonance, the mechanical quality factor $Q_m$ dependences on $H_{dc}$ results in the differences between the low-frequency and resonant ME voltage coefficient with $H_{dc}$. In terms of ${\Delta}E$ effect, the resonant frequency shift is derived with respect to the bias magnetic field. Considering the nonlinear effect of magnetostrictive material and $Q_m$ dependence on $H_{dc}$c, it predicts the low-frequency and resonant ME voltage coefficients as a function of the dc bias magnetic field. A good agreement between the theoretical results and experimental data is obtained and it is found that ME characteristics dependence on $H_{dc}$ are mainly influenced by the nonlinear effect of magnetostrictive material.

신발에 IMU 를 장착한 PNS 에서 방위각 편차의 영향 분석 (An Analysis of the Heading Bias Effects in PNS using IMUs Attached to Shoes)

  • 김상식;이연규;박찬식
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.1053-1059
    • /
    • 2013
  • Heading bias effects in PNS using IMUs attached to shoes are analyzed in this paper. The navigation algorithms of a single foot PNS where one IMU is attached to a foot and dual foot PNSs where two IMUs are attached to each foot are derived. Two navigation algorithms are proposed for the dual foot PNS: 1) the positions from the independent right and left foot PNSs are averaged to provide the final position, 2) the right and left foot PNSs are correlated and it provides positions of each foot. Furthermore, it is proven that two methods are equal. Using the derived navigation algorithms the effect of heading bias caused by a misalignment of the moving direction and IMU is analyzed. The analysis explains the position error of a single foot PNS is diverged while the heading bias is effectively compensated in dual foot PNSs because of the symmetry of heading biases. The experimental results confirm the analysis.

모사된 화재의 열적환경에서 FDS를 이용한 온도 예측오차에 관한 수치해석 연구 (A Numerical Study on Temperature Prediction Bias using FDS in Simulated Thermal Environments of Fire)

  • 한호식;김봉준;황철홍
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.14-20
    • /
    • 2017
  • A numerical study was conducted to identify the predictive performance for the bare-bead thermocouple (TC) using FDS (Fire Dynamics Simulator) in simulated thermal environments of fire. A relative prediction bias of TC temperature calculated from reverse-radiation correction by FDS was evaluated with the comparison of previous experimental data. As a result, it was identified that the TC temperatures predicted by FDS were lower than the temperatures measured by bare-bead TC for the ranges of heat flux and gas temperature considered. The relative prediction bias of TC temperature by FDS was gradually increased with the increase in radiative heat flux and also significantly increased with the decrease in the gas temperature. Quantitatively, at the gas temperature of $20^{\circ}C$, the TC temperature predicted by FDS had the relative bias of approximately -20% with the radiative heat flux of $20kW/m^2$ corresponding to thermal radiation level of the flashover. It is predicted from the present study that more accurate validation of fire modeling will be possible with the quantitative prediction bias occurred in the process of reverse-radiation correction of temperature predicted by FDS.

Annealing Effect on Exchange Bias in NiFe/FeMn/CoFe Trilayer Thin Films

  • Kim, Ki-Yeon;Choi, Hyeok-Cheol;You, Chun-Yeol;Lee, Jeong-Soo
    • Journal of Magnetics
    • /
    • 제13권3호
    • /
    • pp.97-101
    • /
    • 2008
  • We investigated the exchange bias fields at the NiFe/FeMn and FeMn/CoFe interfaces in 18.9-nm NiFe/15.0-nm FeMn/17.6-nm CoFe trilayer thin films as the annealing temperature was varied from room temperature to $250^{\circ}C$ in a vacuum for 1 hour in a magnetic field of 150 Oe. Interestingly, magnetic hysteresis (M-H) measurements showed that NiFe/FeMn/CoFe trilayer thin films exhibited a completely contrasting variation of the exchange bias fields at both the NiFe/FeMn and FeMn/CoFe interfaces with annealing temperatures. High-angle X-ray diffraction (XRD) measurements indicated the absence of any discernible effect of thermal treatment on the NiFe(111) and FeMn(111) peaks. The compositional depth profile obtained from X-ray photoelectron spectroscopy (XPS) results presented the asymmetric compositional depth profiles of the Mn and Fe atoms throughout the FeMn layer. We contend that this asymmetric compositional depth profile and the preferential Mn diffusion into the NiFe layer, compared to that into the CoFe layer, are conclusive experimental evidence of the contrasting variation of the exchange bias fields at two interfaces having a common polycrystalline FeMn(111) layer.

D.C. 전압 인가에 의한 Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al 캐패시터의 산소흡착/탈착 반응 (Oxygen Adsorption/Desorption Reaction of Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al Capacitor)

  • 이재흥;이주헌;김창교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1222-1225
    • /
    • 1997
  • A gaseous oxygen detector has been developed in a configuration of Pd-$SnO_x$-$Si_3N_4$-$SiO_2$-Si-Al with highly resistive $SnO_x$ layer as the oxygen adsorptive element. In this paper, we present the characteristics of the device in response to oxygen adsoption/desorption under applied d.c. bias. Experimental results showed that the oxygen adsorptive response by the device was reduced significantly under a positive gate bias, for all experimental regions of $O_2$ partial pressure. On the other hand, the application of a negative gate bias increased the device's adsorptive response of oxgyen. A device model concerning this electroadsorption/desorption behavior of the device is provided.

  • PDF

The Effect of Twist Liveliness on the Woven Fabric Distortion

  • Alamdar-Yazdi A.;Khojasteh M.R.
    • Fibers and Polymers
    • /
    • 제7권1호
    • /
    • pp.79-84
    • /
    • 2006
  • This paper deals with the grey fabric deformation during relaxation. It investigates the effect of twist direction and twist liveliness on the 2/2 twill weave woven fabric distortion, during relaxation This experimental work shows that twist liveliness increases the natural tendency of the twill weave woven fabric to skew. In addition when the twist direction of the warp and weft is opposite to each other the bias curling occurs too.

Rodent peri-implantitis models: a systematic review and meta-analysis of morphological changes

  • Ren Jie Jacob Chew;Jacinta Xiaotong Lu;Yu Fan Sim;Alvin Boon Keng Yeo
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.479-495
    • /
    • 2022
  • Purpose: Rodent models have emerged as an alternative to established larger animal models for peri-implantitis research. However, the construct validity of rodent models is controversial due to a lack of consensus regarding their histological, morphological, and biochemical characteristics. This systematic review sought to validate rodent models by characterizing their morphological changes, particularly marginal bone loss (MBL), a hallmark of peri-implantitis. Methods: This review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. A literature search was performed electronically using MEDLINE (PubMed), and Embase, identifying pre-clinical studies reporting MBL after experimental peri-implantitis induction in rodents. Each study's risk of bias was assessed using the Systematic Review Center for Laboratory animal Experimentation (SYRCLE) risk of bias tool. A meta-analysis was performed for the difference in MBL, comparing healthy implants to those with experimental peri-implantitis. Results: Of the 1,014 unique records retrieved, 23 studies that met the eligibility criteria were included. Peri-implantitis was induced using 4 methods: ligatures, lipopolysaccharide, microbial infection, and titanium particles. Studies presented high to unclear risks of bias. During the osseointegration phase, 11.6% and 6.4%-11.3% of implants inserted in mice and rats, respectively, had failed to osseointegrate. Twelve studies were included in the meta-analysis of the linear MBL measured using micro-computed tomography. Following experimental peri-implantitis, the MBL was estimated to be 0.25 mm (95% confidence interval [CI], 0.14-0.36 mm) in mice and 0.26 mm (95% CI, 0.19-0.34 mm) in rats. The resulting peri-implant MBL was circumferential, consisting of supra- and infrabony components. Conclusions: Experimental peri-implantitis in rodent models results in circumferential MBL, with morphology consistent with the clinical presentation of peri-implantitis. While rodent models are promising, there is still a need to further characterize their healing potentials, standardize experiment protocols, and improve the reporting of results and methodology.

반복압축하의 응집된 알루미나 분말의 치밀화 (Densification of Aggregated Alumina Powder under Cyclin Compaction)

  • 김기태;손건석;서정
    • 한국세라믹학회지
    • /
    • 제29권2호
    • /
    • pp.136-142
    • /
    • 1992
  • The effects of cyclic stress, frequency and bias-pressure on densification of Al2O3 powder cyclic compaction are investigated. The effect of frequency was not significant on densification of Al2O3 powder under cyclic compaction. The higher the cyclic stress and the lower the bias pressure, the higher densification was achieved. To obtain a higher densification, cyclic compaction was more efficient than 1 stroke compaction. A densification equation was proposed to describe an cyclic time dependent pressure-volume relation for Al2O3 powder under cyclic compaction. This equation was obtained empirically, based on the pressure-volume equation proposed by Cooper and Eaton, the time dependent densification equation by Kim and Suh and experimental data for Al2O3 powder under cyclic compaction. The agreement between the proposed equation and experimental data for Al2O3 powder under cyclic compaction was very good.

  • PDF

단상 SRM의 운전 특성 개선을 위한 새로운 패시브 컨버터 (A Novel Passive Converter for Improving Drive Characteristics of a Single Phase SRM)

  • 이동희;;안진우
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1519-1525
    • /
    • 2009
  • This paper presents a novel passive converter for single phase SRM. The proposed passive converter has additional passive power circuit which is consisted by three diodes and one capacitor in the front-end of conventional asymmetric converter to supply a high negative bias during demagnetization. The high negative bias can reduce the demagnetization time and negative torque from tail current in single phase SRM. So, It can extend positive torque region by the extended turn-off position. In this paper, the structure and operating modes of a novel passive converter are introduced with mathematical model. The proposed single phase SRM using passive converter is verified by the computer simulation and experimental results.

비대칭 마그네트론 스퍼터링법으로 성장된 a-C:H의 물리적 특성 (Characteristics of Hydrogenated Amorphous Carbon (a-C:H) Thin Films Grown by Close Field UnBalanced Magnetron Sputtering Method)

  • 박용섭;홍병유
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.278-282
    • /
    • 2004
  • The Hydrogenated amorphous carbon(a-C:H) thin films are deposited on silicon with a close field unbalanced magnetron(CFUBM) sputtering systems. The experimental data are obtained on the depositon rate and physical properties of a-C:H films using DC bias voltage and Ar/C$_2$H$_2$ pressure. The depostion rate and the surface roughness decrease with DC bias voltage, but the hardness of the thin films increases with DC bias voltage. And the position of G-peak moves to lower wavenumber indicating an increase in diamond-like carbon characteristics with the lower Ar/C$_2$H$_2$ pressure.