• Title/Summary/Keyword: Experimental Facilities

Search Result 761, Processing Time 0.026 seconds

An Experimental Research on the Room Acoustical Environment of the Elementary School Classrooms (초등학교 교실의 음환경 평가에 관한 실험적 연구)

  • Haan, Chan-Hoon;Moon, Kyu-Chun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.1
    • /
    • pp.5-14
    • /
    • 2004
  • Since 1990s in Korea, elementary school classrooms have been designed toward open education system in pursuit of variety of educational purpose. Also, the architectural designs of schools have been acomplished for individual school not based on the standard design code. The present paper aims to investigate the acoustic environment of existing classrooms and to compare the sound insulation capacity between the ordinary classrooms and the newly built classrooms for open education. The current acoustical situation of elementary classrooms was analyzed using field measurements and questionnaire survey. In order to this, Three elementary schools were selected which were built in 1978, 1996 and 2000 respectively. Room acoustical parameters including Reverberation time(RT), Definition(D50), Speech Intelligibility(RASTI), Transmission loss(TL) and STC were measured in a classroom in each elementary school classroom. Each measurement was undertaken with the windows and doors being open or closed. As the result, it was found that the transmission loss between rooms in open classrooms is, $5{\sim}6dB$ in average, inferior than the ordinary classrooms. The RASTI of 0.70 was measured in newly built classrooms which is better than old classrooms(0.70) and open classrooms(0.73). This was shown as same in the speech definition measurements. This results from the condition of sealing and airtightness of classrooms and floor materials. The results denote that open classrooms have poor acoustic condition in sound insulation and speech intelligibility.

Implementation of Greenhouse Environment Monitoring System based on Wireless Sensor Networks (무선센서네트워크 기반 온실환경 모니터링 시스템 구현)

  • Lee, Young-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.11
    • /
    • pp.2686-2692
    • /
    • 2013
  • In this paper, various growth environment data collecting and monitoring based on wireless sensor network for greenhouse environmental monitoring system is designed and implemented. In addition, greenhouse control system is proposed to integrated control and management in internal environment and greenhouse facilities. The system provides real-time remote greenhouse integrated management service which collects greenhouse environment information and controls greenhouse facilities based on wireless sensor network. Graphical user interface for an integrated management system is designed based on the HMI and the experimental results show that the sensor data were collected by integrated management in real-time.

Visual Environmental Influence on an User's Psycho-physiological Health at Healthcare Facilities (시간적 환경이 의료시설 이용자의 건강에 미치는 정신생리학적 영향)

  • Kim Nam-Gil
    • Journal of the Korean housing association
    • /
    • v.17 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study is to understand how visual factors of healthcare facilities would have an effect on psycho-physiological health of inpatients. First, visual factors of a ward, where inpatients mostly spend their time in a hospital, were extracted in order to find out how visual environment would affect inpatient's health. Then experimental samples were made and inpatients' reactions against them were analyzed. This study is composed of two approaches a questionnaire for psychological analysis and an electroencephalogram measurement for physiological analysis. The results of this experiment show that psycho-physiological health of subject's can be remarkably improved according to artificial arrangement of visual environment of a ward. Especially, they also show that insignificant changes of visual environment such as furnishing trees, flowerpots or framed pictures in a ward, where there is no view and completely closed, will be able to exert a range of positive effects on an subject's psycho-physiological health. In conclusion, further studies need to be delivered about indoor designs to positively bring in natural elements to a ward as well as visibility ratio of views and skylines from a ward.

A Study on Accidents Occurred in Primary Schools and on the Experimental Test of the Safety of Building Floors (초등학교의 시설물 관련 안전사고 실태분석 및 실내바닥의 거주안전성에 관한 실험적 연구)

  • Choi, Soo-Kyung;Park, Chan-Joo;Kim, Soo-Gil
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.3
    • /
    • pp.21-32
    • /
    • 2010
  • The purpose of this study is to examine the improvement of the slipperiness of building floors and to test the safety in accidental collision in the primary schools. To perform this purpose effectively, the actual 20,202 cases of accident on the year 2000-2009 which had been dealt by Seoul School Safety and Insurance Association were analysed in several aspects. And to test the current slipperiness and hardness of building floors, 3 primary schools whose construction year differed were examined. This study found that among the indoor accidents of 2,646 cases on the year 2000-2002, 70.7% accidents of them were caused by slipperiness. It was also found that the building floors of the primary schools could not be safe from the result of examining the slipperiness and hardness of the building floors. As the result of this study, it showed that the desirable efficient criterion of slipperiness would be more than C.S.R 0.4, and that of safety in accidental collision would be less than Gs 100G for the safety of primary school students.

Seismic Retrofit in Educational Facilities Using Attaching Composite Material (부착형 복합소재를 이용한 교육시설의 내진보강)

  • Park, Choon-Wook;Song, Geon-Su;Park, Ik-Hyun;Kim, Dong-Hwi
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 2013
  • In paper after the strong earthquake of recently the Korea neighborhood, the Korean government survey show that the 86% of school buildings in Korea are in potential damage risk and only 14% of them are designed as earthquake-resistance buildings. Earthquake Reinforcing projects of school have been a leading by the ministry of education, however their reinforcing methods done by not proved a engineering by experiment which results in uneconomical and uneffective rehabilitation for the future earthquake. An experimental and analytical study have been conducted for the shear reinforcing method of column by axis and horizontal axis load using attaching composite beam. Based on the previous research, in this study, Design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted and strengthening method is going to be on the market after their performance is proved by the test.

A Pilot Study on Air Flotation Processes for Retrofitting of Conventional Wastewater Treatment Facilities (하수처리시설의 Retrofitting을 위한 파일럿 규모 공기부상공정 연구)

  • Park, Chanhyuk;Hong, Seok-Won;Lee, Sanghyup;Choi, Yong-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.329-336
    • /
    • 2008
  • The pilot study was conducted to evaluate the applicability of air flotation(AF) processes combined with biological nutrient removal(BNR) for the retrofitting of conventional wastewater treatment facilities. The BNR system was operated in pre-denitrification and intermittent aeration; developed ceramic membrane diffusers were installed to separate the solid-liquid of activated sludge at the bottom of a flotation tank. Before performing a pilot scale study, the size distribution of microbubbles generated by silica or alumina-based ceramic membrane diffusers was tested to identify the ability of solid-liquid separation. According to the experimental results, the separation and thickening efficiency of the alumina-based ceramic membrane diffuser was higher than the silica-based ceramic membrane diffuser. In a $100m^3/d$ pilot plant, thickened and return sludge concentration was measured to be higher than 15,000mg SS/L, therefore, the MLSS in the bioreactor was maintained at over 3,000mg SS/L. The effluent quality of the AF-BNR process was 4.2mg/L, 3.7mg/L, 10.6mg/L and 1.6mg/L for $BOD_5$, SS, T-N and T-P, respectively. Lastly, it was revealed that the unit treatment cost by flotation process is lower than about $1won/m^3$ compared to a gravity sedimentation process.

A Constructive Algorithm for p-Median Facility Location (p-중앙 시설 위치선정 구성 알고리즘)

  • Lee, Sang-Un
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.6
    • /
    • pp.77-85
    • /
    • 2015
  • This paper proposes a location algorithm that locates newly built p-facilities in the optimal area with minimum cost in a city of n districts. This problem has been classified as NP-hard, to which no polynomial time algorithm exists. The proposed algorithm improves the shortcomings of existing Myopic algorithm by constructing until p-facilities and exchanging locations of p-th facility for p=[1, n-1]. When applied to experimental data of n=5, 7, 10, 55, the proposed algorithm has obtained an approximate value nearest possible to the optimal solution take precedence of reverse-delete method. This algorithm is also simply executable using Excel.

Chromaticity removal by chlorine and ozone oxidation in water treatment (상수처리에서 염소 및 오존산화를 이용한 색도제거)

  • Lee, Jeonghoon;Kim, Jinkeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.273-279
    • /
    • 2017
  • Optimal processes to remove chromaticity at E water treatment plant(WTP) mainly caused by algae of E lake in Jeju island were investigated based on lab-tests of chlorine and ozone oxidation. 42.9% of chromaticity of filtered water was removed by chlorine oxidation under pH 7.0~8.0, dose of 1.0 mg/L with contact time of 30~60 min. On the other hand, chromaticity removal was 71.4% when post-ozone dose of 0.9~1.9 mg/L and pH 9.0, while it was increased to 86.7% under post-ozone dose of 3.1~7.3 mg/L and pH 9.0. However, there was no significant chromaticity removal efficiency increase when ozone doses were higher than 5.0 mg/L regardless of feeding point(i.e., pre-ozonation and post-ozonation) and pHs(i.e., 7.0 and 9.0.) under the experimental conditions. Based on the results, chlorine oxidation using existing chlorination facilities at the WTP is recommended for lower chromaticity while ozone oxidation is recommended for higher chromaticity by installing new ozone feeding facilities.

School-Building Remodelling Model using Discriminant Analysis - A Case Study for Class Rooms in School Building - (학교건물의 노후화에 따르는 개축 판정에 관한 모델의 정립)

  • Min, Chang-Kee
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.4 no.4
    • /
    • pp.29-41
    • /
    • 1997
  • The objective of this paper is to construct a model to be used in deciding whether to repair or rebuild school buildings is depending on their ages and other factors. The theme of this paper is the age is the main variable but other factors such as floor, innerwall, ceiling, door, inner window of the class room, outer window of the class room, inner window of the corridor, outer window of the corridor, middle window between the classroom and the corridor, light, heater, speaker, fire protection sensor, TV monitor, and telephone status would influence the final decisions. This paper employs an experimental case study method. Using the stepwise, statistical, classification method commonly used in discriminant analysis, it evaluates 12,766 rooms of 87 different high schools in Seoul. The result of this study indicates that some critical variables influencing the final decisions are the status of TV monitor, middle window between the classroom and the corridor, light, inner window of the corridor, fire protection sensor, innerwall, speaker utensil, outer window of the class room, and door of the class room. This paper also suggests a linear discriminant function will be used for this kind of studies. Finally the paper recommends policies with respect to the variables and discriminant functions evaluated.

  • PDF

A Study on the Thermal Response Characteristics of Snow Removing Facilities using Heat Pipe (히트파이프식 제설설비의 열응답 특성에 관한 연구)

  • Lee, Yong-Soo;Jang, Yeong-Suk
    • Solar Energy
    • /
    • v.17 no.4
    • /
    • pp.45-56
    • /
    • 1997
  • The purpose of this research was to study the characteristics of heat transfer of snow removing facilities using heat pipe by experimental method. Heat pipes was constructed a flexible tube connected between evaporator and condenser ends for altitude adjustment of evaporator and it was constituted an internal diameter of 25.4mm, a length of 950mm for heating section and a length of 6000mm for condenser section with copper material for closed system. The results showed that the effect of heat transfer was increased when inclination angle and inlet temperature of heating water increased. Wall temperature response by inclined angle $4.5^{\circ}c-9^{\circ}c$ and working fluid amount 0.96 from to 1.3 times of evaporator volume were better than those of other working fluid and angle.

  • PDF