• Title/Summary/Keyword: Experiment In Water Tank

Search Result 391, Processing Time 0.023 seconds

Oscillating Water Column (OWC) Wave Energy Converter Part 1: Fixed OWC

  • Yang, Hyunjai;Jung, Hyen-Cheol;Koo, WeonCheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.280-294
    • /
    • 2022
  • This study reviews the recent development and research results of a fixed oscillating water column (OWC) wave energy converter (WEC). The OWC WEC can be divided into fixed and floating types based on the installation location and movement of the structure. In this article, the study on a stationary OWC WEC, which is close to commercialization through the accumulation of long-term research achievements, is divided into five research categories with a focus on primary energy conversion research. These research categories include potential-flow-based numerical analysis, wave tank experiments, computational fluid dynamics analyses toward investigation of fluid viscous effects, U-shaped OWC studies that can amplify water surface displacement in the OWC chamber, and studies on OWC prototypes that have been installed and operated in real sea environments. This review will provide an overview of recent research on the stationary OWC WEC and basic information for further detailed studies on the OWC.

Response of Filefish to the Colored Nets (색망지에 대한 말쥐치의 반응)

  • Yang, Yong-Rim;An, Hui-Chun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.18 no.1
    • /
    • pp.11-15
    • /
    • 1982
  • The authors carried out an experiment to find out the response of filefish, Navodon modestus (Gunther), to the colored nets. The experimental tank of dimensions 360L$\times$50W$\times$55H cm was set up in a dark room. Six longitudinal sections, each being 60cm intervals, are marked in the tank to observe locations of the fishes. The depth of water in the tank was 50 cm. Two light bulbs of 30 W, placed at the both ends of the tank, projected the light horizontally into the tank. Two different colored nets selected from seven colors(white, black, gray, red, green, blue, and yellow) were placed 60 cm distance from each side of the tank. The fishes were acclimatized in the dark for 60 minutes before they were employed in the experiment. After the light was turned on, the number of fish in each section of the tank was counted for an hour in every 2 minutes into interval, the mean value of fishes in each section was used as the distribution rate of the fish. The order of colors disliked by fishes was found to be white, red, green, black, blue, yellow and gray. The distribution rate of fish in front of colored net shows a decreasing tendency as the lapse of illumination time increases.

  • PDF

Rearing Olive Flounder Paralichthys olivaceus in a Water Reuse System with Mineral Particles and foam Fractionator (광물미립자와 포말분리장치를 이용한 사육수 재사용시스템에서의 넙치(Paralichthys olivaceus) 사육실험)

  • 민병서;강필애
    • Journal of Aquaculture
    • /
    • v.13 no.3
    • /
    • pp.223-230
    • /
    • 2000
  • A rearing experiment of the olive flounder was performed in a set of water-reuse system to test the reusability of the water in culture system with (i) a foam fractionator to separate particles from water and (ii) a culture tank contain mineral particles to filter the metabolic wastes by adsorption and/or decomposition. Two kinds of commercially processed loess particles and a dolomite particle (all 50 ${\mu}$diameter) were tested. The mineral particles were suspended in the culture tank and the water was pumped into the foam fractionator, where the particles were separated and drained out with foam from the system. In a circular culture tank of 4.8 m in diameter with 10 d water, the juvenile olive flounders (23.1 g/fish, 5,555 fish, 128 kg total body weight) were stocked. 90 % of the rearing water was reused and turnover rate of the water in the tank was two times per hour. Water temperature was maintained 17${\pm}$1$^{\circ}C$. At the end of 75 day-experimental rearing, 5,532 flounders, weighing 468 kg, were harvested. An individual flounder grew to 84.6 g of body weight. The final stocking density was 26.0 kg/$m^2$. No diseases were observed during the experiment.

  • PDF

Fish Growth Experiment in a Green water Recirculating System (순환 Green Water 사육장치 내에서의 어류의 성장실험)

  • KIM In-Bae;LEE Sook-Hee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.233-238
    • /
    • 1981
  • A recirculating water system without filter bed was used for a high density experimental rearing of common carp, Cyprinus carpio, during the summer of 1981. Of the water system, 3 tanks were used for stocking each tank with 10,000, 20,000 and 30,000 common carp fingerlings which averaged 0.6 g. The water in the system was maintained in dark green colour by heavy growth of phytoplankton during the most period of the experiment. In this experiment, the best daily growth rate, $3.7\%$, was obtained from the 10,000 fish group followed by $2.8\%\;and\;3.0\%$ from the 20,000 and 30,000 fish groups respectively. Thus there was no significant difference between the latter two groups. Especially, notably high concentration of total ammonia, $5\sim7$ ppm ammonia-N, in the culture water appeared during the most experimental period, but this did not seem to have affected feeding and growth of the fish when the water was kept at heavy bloom. It was also obvious that the outbreak of columnaris disease was effectively depressed in this green water recirculating system compared to that in clarified recirculating system. One tank ($7m^2$) of this system was stocked with 446 common carp of intermediate size averaging 352.2 g and after 40 day rearing they grew to 486.3 g in average with a daily growth rate of $0.8\%$. This result was a little inferior to that reared in a tank of the clarified water system as control which showed $1.0\%$ daily growth rate. Therefore, before an initiation of the commercial production of fish in this method, further studies concerning the amount of ammonium with its effect on the fish under rearing in this system and the columnaris disease problem should be carried out.

  • PDF

Volume of Water Storage and Evapotranspiration by Inserted Materials at a Reservoir of Porous Grass Block (저수형 잔디블록 저수조 내 충진재료에 따른 저수량 및 초종별 증발산량)

  • Han, Seung-Ho;Choi, Joon-Soo;Yang, Geun-Mo;Yang, Byoung-E;Kang, Jin-Hyoung;Kim, Won-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.5 s.118
    • /
    • pp.76-83
    • /
    • 2006
  • The purpose of this study was to investigate the performance of porous grass block. For the investigation, Festuca arundinacea and Zoysia japonica 'Zenith' were planted, and the volume of evapotranspiration and remains were examined based on different materials in the water tank in the experiment of Festuca arundinacea, the volume of water storage of treatment with perlite ($10.84{\iota}/m^2$) was higher than that with drainage ($7l/m^2$). The difference between the two was $3.84/m^2$. The drainage treatment without water storage capacity showed the higher degree of dryness in turf grass. The volume of evapo-transpiration of treatment with perlite was the highest (21.57mm/week). The volume of evapotranspiration of treatment with sand was 19.57mm/week, and with treatment with drainage was 18.24mm/week. Based on the measured volume of daily evapotranspiration of $2.60{\sim}3.08mm\;d^{-1}$, it was determined that the unit with water storage capacity would store water of one to two days usage compared to unite without such storage capacity. In the experiment of Zoysia japonica 'Zenith', the volume of water storage of treatment with perlite was $10.77l/m^2$ which was similar to the former experiment. The volume of evapotranspiration of treatment with perlite and sand were 21.64mm/week and 20.64mm/week, respectively. In case of airtight water tank, the volume was measured as 22.06mm/week. Each treatment has no notable difference in the volume of evapotranspiration. In conclusion, from the investigation in this study, porous grass block with water tank was found to be effective in plant growth under low irrigation. As the ecological area ratio and vegetated porous pavement have became more emphasized, additional study of rain infiltration and reservoir effect are needed in the future.

An Effect of Insulated Raft on Longterm Hot Water Storage (Insulated Raft가 장기온수저장에 미치는 영향)

  • Pak, Ee-Tong;Cho, Woon
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.79-91
    • /
    • 1997
  • Thermal energy storage system used a storage tank is a reasonable method to solve energy problem. In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load at the time is in demand. In this study, flow characteristics and storage efficiency were analysed by using a insulated raft in longterm hot water storage system. From the experiment it is found that insulated raft has a important role in longterm hot water storage system and storage efficiency can be obtained to 96% using inletport type and insulated raft together.

  • PDF

Numerical Analysis of Melting Process in a Water Tank for Fuel-cell Vehicles (연료전지 자동차의 물탱크 해빙과정에 대한 수치해석적 연구)

  • Kim, Hark-Koo;Jeong, Si-Young;Hur, Nahm-Keon;Lim, Tae-Won;Park, Yong-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.585-592
    • /
    • 2007
  • Good cold start characteristics are essential for satisfactory operation of fuel cell vehicles. In this study, the melting process has been numerically investigated for a water tank used in fuel cell vehicles. The 2-D model of the tank containing ice and plate heaters was assumed and the unsteady melting process of the ice was calculated. The enthalpy method was used for the description of the melting process, and a FVM code was used to solve the problem. The feasibility study compared with other experiment showed that the developed program was able to describe the melting process well. From the numerical analysis carried out for different wall temperatures of the pate heaters, some important design factors could be found such as local overheating and pressurization in the tank.

Simulation of Open-Loop Borehole Heat Exchanger System using Sand Tank Experiment and Numerical Model (토조 및 수치모형을 이용한 개방형 지중 열교환 시스템 모의)

  • Lee, Seong-Sun;Bae, Gwang-Ok;Lee, Kang-Kun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.489-492
    • /
    • 2007
  • Understanding the thermohydraulic processes in the aquifer is necessary for a proper design of the aquifer thermal energy utilization system under given conditions. Experimental and numerical test were accomplished to evaluate the relationship between the geothermal heat exchanger operation and hydrogeological conditions in the open-loop geothermal system. Sand tank experiments were designed to investigate the open-loop geothermal system. Water injection and extract ion system as open-loop borehole heat exchanger was applied to observe the temperature changes in time at injection well, extraction well and ambient groundwater. The thermohydraulic transfer for heat storage was simulated using FEFLOW for two cases of extraction and injection phase operation in sand tank model. As one case, the movement of the thermal plume was simulated with variable locations of injection and extraction well. As another case, the simulation was performed with fixed location of injection and extraction well. The simulation and experimental results showed that the temperature distribution depends highly on the injected water temperature and the length of injection time and the groundwater flow and pumping rate sensitively affect the heat transfer.

  • PDF

Numerical analysis of melting process in a water tank for fuel-cell vehicles (연료전지 자동차의 물탱크 해빙과정에 대한 수치해석적 연구)

  • Kim, Hark-Koo;Jeong, Si-Young;Hur, Nahm-Keon;Lim, Tae-Won;Park, Yong-Sun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.74-79
    • /
    • 2006
  • Good cold start characteristics are essential for satisfactory operation of fuel cell vehicles. In this study, the melting process has been numerically investigated for a water tank frozen in cold weather The 2-D model of the tank containing ice and plate heaters was assumed and the unsteady melting process of the ice was calculated. The enthalpy method was used for the description of the melting process, and a FVM code was used to solve the problem. The feasibility study compared with other experiment showed that the developed program was able to describe the melting process well. From the numerical analysis carried out for different wall temperatures of the pate heaters, some important design factors could be found such as local overheating and pressurization in the tank.

  • PDF

Evaluation of Solids Removal Characteristics on Sewage Treatment Plants Using T-P sludge Return into the Primary Settling Tank (총인슬러지의 1차 침전지 반송에 따른 하수처리장 고형물 제거특성 연구)

  • Kim, Jong-Oh;Jung, Dong-Gi;Kwon, Hye-Jeong;Hwang, Joon-Seok
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.73-80
    • /
    • 2018
  • In this study, the solids removal characteristics using T-P sludge generated from PACl coagulation were analyzed by laboratory scale and full scale experiment. As the amounts of T-P sludge injection into the raw sewage influent increased at the rate of 0, 1, 2, 3, 4 %, the suspended solids concentrations after 20 minutes setting test decreased to 210, 137, 91, 64, 43 mg/L, respectively. The filtration time required for dewatering test of the raw sewage influent decreased to 982, 728, 658, 581, 492 sec for 0, 1, 2, 3, 4% of T-P sludge injection, respectively. As the amounts of PACl coagulant into the effluent from final setting tank increased at 0, 10, 20, 30, 40 mg/L, the required filtration times for T-P sludge increased into 12.3, 41.7, 53.7, 67.2, 79.5 sec and the dewaterability of T-P sludge decreased. After T-P sludge returned into the primary settling tank on J-si sewage treatment plants, the effluent concentrations of COD, SS, T-N and T-P from primary settling tank into bioreactor decreased by 35.9, 27.9, 22.2, and 52.6% due to the coagulation effects of the T-P sludge. Finally, it was found that the return of T-P sludge into the primary settling tank could result into the sludge reduction having a lower water content of 3.03% p than in case of the only T-P sludge dehydration.