• Title/Summary/Keyword: Exhaust smoke

Search Result 308, Processing Time 0.027 seconds

Review of Association between Air Pollution and Heart Rate Variability (HRV) (대기오염과 심박변이도(Heart Rate Variability, HRV)의 연관성에 대한 고찰)

  • Guak, Sooyoung;Lim, Chaeyun;Lee, Kiyoung;Park, Ji Young
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.4
    • /
    • pp.223-230
    • /
    • 2015
  • Objectives: There is considerable evidence that polluted ambient air contributes to the risk of cardiovascular morbidity and mortality. Heart rate variability (HRV) is defined as the variation in heartbeat intervals and has been reported as a biological marker of cardiovascular disease. This article reviews the existing literature in order to examine the association between air pollution and HRV. Methods: Literature was searched using Web of Science with the key words of "air pollution", "heart rate variability" and other related terms. A total of 156 articles were listed. For review, 21 of those listed publications were chosen after excluding studies regarding chamber studies, occupational environment, secondhand smoke and automobile exhaust. Results: Research methods employed in the publications were classified by type of participants (elderly/adult), air pollution monitoring (ambient/personal) and HRV monitoring (continuous/spot). Among HRV parameters, power in the low frequency range (LF), power in the high frequency range (HF) and standard deviation of all NN intervals (SDNN) were all associated with air pollutants. The chosen studies were mostly based on elderly populations. In studies based on continuous HRV monitoring, LF and SDNN significantly decreased when $PM_{2.5}$ exposure increased. Conclusion: Continuous HRV monitoring combined with personal exposure monitoring has been one of the most common study methods in recent publications. We expect that this review will be useful for the study of the association between air pollution and cardiovascular effects using HRV.

Automobile Engine Information Display Device Using CAN Communication (캔 통신을 이용한 자동차 엔진 정보 표시장치)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.17 no.12
    • /
    • pp.203-210
    • /
    • 2019
  • Most cars today use electronic control to control the state of the engine to achieve optimum performance. This study developed a device for maintaining fault diagnosis and optimal vehicle status by displaying the engine information of a car on the screen in real time using can communication. This system displays information generated from the engine to the driver in real time such as engine intake and exhaust temperature, current battery voltage, tire pressure, RPM, DPF collection amount, torque, and horsepower through the OBD2 socket. You can check immediately. It can help you to drive safely by measuring tire pressure and displaying it on the screen, and it provides a mode to set the shift timing to suit your taste. In particular, in the case of diesel engine cars, the problems caused by smoke can adversely affect the performance and environmental pollution. Therefore, the system was developed to display the DPF collection amount on the system screen to prevent environmental pollution and to manage the vehicle efficiently.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Effect of Injection Pressure and Injection Timing on Spray and Flame Characteristics of Spray-Guided Direct-Injection Spark-Ignition Engine under Lean Stratified Combustion Operation (성층희박연소 운전조건에서 분사시기에 따른 분무유도식 직접분사 가솔린엔진의 분무 및 화염특성)

  • Oh, Heechang;Lee, Minsuk;Park, Jungseo;Bae, hoongsik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.221-228
    • /
    • 2013
  • An experimental study was carried out to investigate the effects of the injection timing on the spray and combustion characteristics in a spray-guided direct-injection spark-ignition (DISI) engine under lean stratified operation. An in-cylinder pressure analysis, exhaust emissions measurement, and visualization of the spray and combustion were employed in this study. The combustion in a stratified DISI engine was found to have both lean premixed and diffusion controlled flame combustion characteristics. The injection timing condition corresponding to the stratified mixture characteristics was verified to be a dominant factor for these flame characteristics. For the early injection timing, a non-luminous blue flame and low combustion efficiency were observed as a result of the lean homogeneous mixture formation. On the other hand, a luminous sooting flame was shown at the late injection timing because of an under-mixed mixture formation. In addition, the smoke emission and incomplete combustion products were increased at the late injection timing as a result of the increased locally rich area. On the other hand, the NOx emissions decreased and IMEP increased as the injection timing retarded. The combustion phasing produced by the injection timing was verified as the reason for this observation.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.

Epidemiological Study of Air Pollution and Its Effects on Health of Urban Population (서울시(市) 대기오염(大氣汚染)이 시민보건(市民保健)에 미치는 영향(影響)에 관(關)한 조사연구(調査硏究))

  • Chung, Kyou-Chull
    • Journal of Preventive Medicine and Public Health
    • /
    • v.2 no.1
    • /
    • pp.5-22
    • /
    • 1969
  • The urban population of our country is rapidly increasing due to many factors of social structure, and sociologists are predicting that the increase rate of the urban population will be over 50% in 1980's. Above all, the population of the capital city of Seoul, is at present more than four millions. Such centring of people in cities, together with the improvement of the standards of living, caused rapid increase in the amount of fuel consumption, and this consumption of fuels became one of the primary sources of the air pollution in cities. Moreover, the heavy traffic, construction of many tall buildings, and the increasing number of new factories due to the industrial development-all these are contributing to make the matter of air pollution worse and worse in the Metropolitan, whose geographical location is quite unfavorable considered from the view point of air pollution. Most homes in Seoul use briquet as fuel, while oils are used in tall buildings. The CO, $SO_2$, and smoke that come from burning of these fuels are a great threat to the health of the urban population. With the purpose of examining the influence of air pollution upon the public health, written inquiries were made upon respiratory diseases, and the carboxyhemoglobin saturation in the blood was measured to determine whether the air pollution may affect the health of the urban population. Method of Health Examination (1) Investigation of Respiratory Diseases Patients' records were examined to figure out the monthly ambulance rate of respiratory patients to the total number of patients treated. On the other hand, by using the questionnaire form approved by the Medical Research Council's Committee on Research into Chronic Bronchitis, investigators interviewed the examinees and inquired into the respiratory symptoms. (2) Measuring of Carboxyhemoglobin Saturation From the ear lobe of the examinees, with the use of the melangeur for the white blood cell counting, blood was taken, and after diluting it ten times with 0.1% $Na{2}CO_{3}$, again diulting it 20 times with 0.5% $Na_{2}\;CO_{3}$, its absorbancy was measured. The following results are obtained from the investigation. (1) It was found out that 7.7% of the total patients under treatment were suffering from upper respiratory infection, acute or chronic bronchitis, bronchial asthma, pulmonary emphysema and bronchiectasis. Of them all, patients with upper respiratory infection numbered the greatest with 4.8% and patients with acute or chronic bronchitis the next with 2.1%, and their monthly ambulance rate was high from December to February during the winter, and from April to May and from September to October during the changeable seasons. (2) The daily ambulance rate of respiratory patients, it was revealed, had a close connection with the concentration of $SO_2$ and CO in the air. (3) It was found out that men were more subject to respiratory disease than women, and both men and women were more liable to the diseases with the advancing of age. (4) People living at Choong-ku with the heavy traffic and in the industrial zones of Yeungdungpo had high frequency of respiratory symptoms. (5) Considered from the view point of occupations, high frequency was found among those without job, with jobs unknown, merchants and intdustrial workers, whose social status was rather low and traffic policemen who were always exposed to the exhaust gas of cars. As for women, the frequency was detected in the order of those from high to low, housewives who were exposed to briquet gas, women with jobs unknown, women without jobs, whose social status was low. (6) Ex-smokers rather than smokers, of both sexes, had higher frequency. As for men, heavy smokers had high frequency, while in women light smokers had rather high frequency which was presumed to be due to their average old age. (7) Men's average of carboxyhemoglobin saturation was 9.48%, while women's was 11.3%, higher than men's. (p<0.05). Age meant no difference in the case of men, but as for women, the saturation was remarkably high between the ages from 20 to 60. (8) No regional difference was detected in the carboxyhemoglobin saturation. (9) The carboxyhemoglobin saturation was found, in the case of men, in the order of office workers, traffic policemen, students, the unemployed, merchants and industrial workers, drivers; and as for women, the order was housewives, office workers, merchants and industrial workers. (10) No significant correlation was found between the carboxyhemoglobin saturation and the concentration of CO detected in kitchens, or between the carhoxyhemoglobin saturation and the passing of time after exposure to briquet gas. No difference of carboxyhemoglobin saturation was detected between smokers and non-smokers, and the degrees of smoking; only, significant negative correlation was found between the passing of time after smoking and the carboxyhemoglobin saturation. It is ture that air pollution causes or aggravates the respiratory diseases, increases the carboxyhemoglobin saturation in the blood, but what seems to be more hazardous to the health is the air polluted by the briquet gas in the kitchens and on-dol rooms rather than the atmospheric air pollution.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.