• Title/Summary/Keyword: Exhaust Temperature

Search Result 1,097, Processing Time 0.025 seconds

A study on temperature characteristic of the gases supplied to SOFC system by utilizing the ship exhaust gas (선박 배기가스 활용에 따른 SOFC 시스템 공급가스의 온도특성에 관한 연구)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.822-828
    • /
    • 2013
  • Since the operating temperature of Solid Oxide Fuel Cell (SOFC) is high, the heat management of the gases supplied to fuel cell system is important. In this paper, the temperature characteristic of the gases supplied to the anode and the cathode of the fuel cell is studied in case of utilizing the waste heat contained in the ship exhaust gas as a heat source to heat up the fuel, gas and water supplied to a 500kW SOFC system for a ship power. For the fuel cell system proposed in this paper, the temperature of gases supplied to the anode and the cathode was the highest temperature at 963K when the exhaust gas of the fuel cell was utilized as the heat source for gases supplied to fuel cell system instead of utilizing the ship exhaust gas. In addition, the engine power did not effect on the temperature of gases supplied to the fuel cell stack.

An Experimental Study on Regeneration Characteristics by Variation of Exhaust Gas Temperature, HC and $O_2$ Concentrations on DOC-CDPF System (배기가스의 온도 및 HC와 $O_2$의 조성 변화에 따른 DOC-CDPF의 재생 특성에 관한 실험적 연구)

  • Cho, Yong-Seok;Lee, Seang-Wock;Lee, Jung-Sub;Yoon, Yu-Bin;Park, Young-Joon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • A catalyzed diesel particulate filter (CDPF) causes the progressive increase in back pressure of an exhaust system due to the loading of soot particles. To minimize pressure drop which is generated by CDPF, the filter should be regenerated when it collects a certain quantity of soot. It is important to know characteristics of regeneration of CDPF with various of exhaust gas temperatures and compositions. The oxidation of HC in DOC leads to increase gas temperature of DOC downstream. The increased gas temperature by DOC has an positive effect on CDPF regeneration. This study presents characteristics of regeneration of CDPF with DOC according to various gas composition, such as HC and $O_2$ concentration. The test-rig is used to control each gas composition and temperature during regeneration of CDPF. Experimental results indicate that the increased concentration of $O_2$ regenerates DPF more actively. With increasing HC concentration, the gas temperature of CDPF upstream increased due to more oxidation of HC. But excessive supply of HC leads to decrease of $O_2$ concentration in the CDPF, which makes it hard to regenerate CDPF.

A Study on the High Temperature Tensile Characteristics of Lap Weld of 15Cr Ferritic Stainless Steels (15Cr 페라이트계 스테인리스강의 겹침용접부 고온인장 특성에 관한 연구)

  • Lee, Young-Gi;Lee, Gyeong-Cheol;Kim, Jae-Seong;Han, Do-Seok;Oh, Seung-Taek;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.26 no.5
    • /
    • pp.60-65
    • /
    • 2008
  • Ferritic stainless steels of the 400 series have been available for automotive exhaust system, heat exchanger, radiater etc. in various industrial because heat resistance, corrosion resistance and strength are excellent. Especially, automotive exhaust system is required good heat resistance because typical temperature of exhaust system exposed during operation of engine is reach up to $800^{\circ}C$. However, research for effect of high temperature in ferritic stainless steels is not enough. In this study, high temperature tensile properties of lap weld of ferritic stainless steels(STS 429) were investigated. In accordance with heat input, lap welds had been produced and were evaluated at high temperature($800^{\circ}C$) to compare high temperature tensile properties. In addition, room temperature tensile tests were carried out for non-aging and aging specimens. As a result of R.T tensile test, non-aging specimens were fractured in base metal except for low heat input specimen and aging specimens were fractured in weld metal. Also high temperature tensile test were carried out by aging specimen. After high temperature tensile test, fracture of aged specimen was occurred in base metal except for low heat input specimen. Fracture surface of low heat input specimen in weld metal was confirmed as brittle fracture with observation using scanning electron microscope(SEM). Significant decrease in ultimate tensile strength (between 82 and 85%) was observed for aged ferritic stainless steels(STS 429) when tested at high temperature.

A Study on Reductions of Cold Start Emissions with Syngas Assist in an SI Engine (합성가스를 첨가한 SI 엔진의 냉간시동 유해 배기가스 저감에 관한 연구)

  • Song, Chun-Sub;Ka, Jae-Geum;Hong, Woo-Kyung;Park, Jeoung-Kwon;Cho, Yong-Seok;Kim, Chang-Gi
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.4
    • /
    • pp.114-120
    • /
    • 2011
  • Fuel reforming technology for the fuel cell vehicles has been frequently applied to internal combustion engine for the reduction of engine out emissions. Since syngas which is reformed from fossil fuel has hydrogen as a major component, it has abilities to enhance the combustion characteristics with wide flammability and high speed flame propagation. In this paper, syngas was feed to a 2.0 liter SI engine with MPI to improve exhaust emissions under cold start and early state of idle condition. Syngas fraction is varied to 0%, 10%, 25%, with various ignition timings. Exhaust emission characteristics and the exhaust system temperature were measured to investigate the effects of syngas addition on cold start. Result showed that HC emission could be dramatically reduced due to the fact that syngas has $H_2$ and no HC as components. The amount of $NO_x$ emission was decreased with the increase of syngas fraction. Because the dilution effect of $N_2$ and the retard of ignition timing reduces the peak combustion temperature inside the cylinder. Exhaust gas temperature was lower than that of gasoline feeding condition. Retarded ignition timing, however, resulted in increased exhaust gas temperature approximated to gasoline condition. It is supposed that the usage of syngas in an SI engine is an effective solution to meet the future strict emission regulations.

The study of combustion gas characteristic by incinerator operation condition. (소각로 운영조건에 따른 연소배가스 특성 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2010
  • This study was done to analyze the condition of combustion exhaust gas that is produced according to incinerator operating condition in A area Kyonggido. The boiler exhaust gas temperature, the oxygen concentration of boiler, the outgassing temperature of Semi Drying Sorber(SDS), the temperature of catalytic reactor, the concentration of NOx, SOx, CO, Hcl and Dust were investigated by change the temperature of incinerator. The concentration of SOx, CO, HCL and DUST were below 5 ppm as increase the temperature of incinerator however the concentration of NOx was increased from 40 ppm to 70 ppm as increase the temperature of incinerator. The boiler exhaust gas temperature and the temperature of catalytic reactor were not changed however the oxygen concentration of boiler was decreased gradually as increase the temperature of incinerator.

A Study on Improvement of the Roof Vents in the Arcade Traditional Market (아케이드형 재래시장의 지붕 환기구 개선 방안에 관한 연구)

  • Ma, Jun Chao;Lee, Byung Hyun;Lee, Kyung Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.17-23
    • /
    • 2018
  • A fire simulation was performed to analyze the temperature and smoke exhaust performance of roof vents of the arcade traditional market by comparing a basic model (Case A) and an improvement model (Case B~Case E). Temperature analysis by heat showed a low temperature distribution because Case E discharged smoke in both directions of length compared to other cases. However, the effect of heat by life safety standards was satisfied. The smoke exhaust analysis by smoke showed the highest performance because Case C was exhausted to 1 m on both sides of length.

The Experimental Study on the Low-temperature Combustion Characteristics of DME Fuel in a Compression Ignition Engine

  • Yoon, Seung Hyun
    • Journal of ILASS-Korea
    • /
    • v.22 no.4
    • /
    • pp.190-196
    • /
    • 2017
  • The aim of this work is to investigate the combustion and exhaust emission characteristics of low-temperature combustion (LTC) at various EGR test conditions using a single cylinder common-rail diesel engine. In high EGR rate combustion mode with DME fuel, 30% (${\Phi}=0.61$) and 50% (${\Phi}=0.86$) of EGR were respectively examined, and then the combustion, exhaust emissions, nano-particle characteristics of each cases were measured. From these results, it revealed that The ignition delay and combustion duration are prolonged as the increase of EGR rate. In addition, at an advanced injection timing (BTDC $30^{\circ}$), ignition delays were fairly increased because the dilution effect of EGR and also low charge in-cylinder temperature created a lean mixture, thus decreased the peak release rate.

An Experimental Study on Characteristics of Temperature Separation in a Vortex Tube for Diesel Engine Exhaust Gas (Vortex Tube의 승용 디젤기관 배기가스 온도 분리특성에 관한 연구)

  • Jung, Young-Chul;Choi, Doo-Seuk;Im, Seok-Yeon;Kim, Hong-Ju;Ryu, Jeong-In
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.1
    • /
    • pp.93-98
    • /
    • 2010
  • An object of this study is to confirm the opening amount of the throttle valve that is begun the temperature separation of vortex tube for various engine speed and load condition in a common rail diesel engine. The vortex tube located at downstream of the exhaust manifold is a device separating the incoming exhaust gas to hot and cold stream. To find optimum separation efficiency of vortex tube, the opening amount of throttle valve has been investigated for various engine speed and load conditions. Engine speed was found that the influence of engine speed was dominant compared with that of engine load. As engine speed was increased, the throttle opening amount starting temperature separation was reduced.

Effect of Recirculation of Rotary Kiln Exhaust Gas for the Carbonation of Lime on the Combustion Conditions and the Amounts of NOx (생석회 탄산화를 위한 회전로 배가스 재순환이 연소 및 NOx 발생양에 미치는 영향)

  • Lee Man-Seung;Lee Si-Hyunh
    • Resources Recycling
    • /
    • v.12 no.1
    • /
    • pp.41-47
    • /
    • 2003
  • In order to improve the hydration resistance of lime in the air at room temperature, carbonation and hydration experiments have been conducted. Carbonation of the surface of lime by about 6 wt% was needed to suppress the hydration of lime used in steel-making. The effect of recirculation of rotary kiln exhaust gas for the carbonation of lime on the combustion temperature and NOx concentration was analyzed by thermodynamics. From the thermodynamic calculation results, it was frond that the equi-librium combustion temperature and NOx concentration decreased with increasing volume percentage of exhaust gas.

Study of Thermoelectric Generator with Various Thermal Conditions for Exhaust Gas from Internal Combustion Engine using Numerical Analysis (수치해석을 통한 엔진 배기가스의 조건 변화에 따른 열전소자 발전 특성에 관한 연구)

  • In, Byung Deok;Lee, Ki Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.243-248
    • /
    • 2013
  • Internal combustion engines typically expel 30%-40% of the energy supplied by fuel to the environment through their exhaust system. Therefore, further significant improvements in the thermal efficiency of IC engines are possible by recovering the waste heat from the engine exhaust gas. With this fact in mind, a numerical simulation was carried out to investigate the potential of using thermoelectric generation with an internal combustion engine for waste heat recovery. Physical parameters such as the exhaust temperature and mass flow rate were evaluated in the exhaust system, and the optimum location for inserting a thermoelectric generator (TEG) into the system was determined. The TEG will be located in the exhaust system and will use the energy flow between the warmer exhaust gas and the external environment. The optimum position of the temperature distribution and the TEG performance were predicted through numerical analysis. The experimental results obtained showed that the power output significantly increases with the temperature difference between the cold and hot sides of the TEG.