• Title/Summary/Keyword: Exciter system

검색결과 127건 처리시간 0.024초

LabVIEW를 이용한 Exciter 가진시험 모듈 개발 (Developing the Excitation Testing Module with LabVIEW)

  • 최기수;정의봉;원성규;안세진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.37-41
    • /
    • 2007
  • Fast Fourier Transformation(FFT) is one of the most useful way to analyze response signal for the purpose of grasping the dynamic characteristics of system. Excitation is a factor or process making noise or vibration. It's typical and simple experimental method widely used for catching hold of dynamic peculiar characters and modal behaviors of system by frequency analysis. There are harmonic excitation, impact excitation, random excitation, sweep excitation, chirp excitation and so on as the ideal method in an experiment using exciter. In this thesis, excitation testing module for NI-PXI equipment is developed. The analyzing module is developed with LabVIEW tool. A user can generate each waveform for shaking a structure and see quickly and easily modal shape of system with this module. This developed module will be expected to build up more convenient and serviceable measurement system.

  • PDF

여자기 제어 효과를 고려한 에너지함수 유도 및 적용가능성에 관한 기초 연구 (Derivation of the Energy Function Reflecting Exciter Control Effects)

  • 김구한;최병곤;박정도;문영현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.125-128
    • /
    • 2000
  • This paper presents an energy function which provides the direct relationships between the system stability and parameters of the exciter system. The energy function is derived from the energy conservation law by using the first motion integral. he time derivative does not absolutely satisfy the seminegativeness. However dE/dt usually has big negative value just after the fault clearing so that the energy is rapidly decreased. In this situation, the system state can be obviously confined in a stable region if the intial energy is less than the UEP energy. With these observation, two theorems are developed regarding the state confinement and asymptotic stability. Based on two theorems a new approximated direct energy method is developed to analyze the transient stability with the consideration of the exciter control effects. The proposed method has been tested for a single-machine-infinite bus system.

  • PDF

궤환 모델 개선법 : 부정정 구조물에의 적용 (Feedback Model Updating: Application to Indeterminate Structure)

  • 정훈상;박영진;박윤식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.59-64
    • /
    • 2003
  • The parameter modification of the initial FEM model to match it with the experimental results needs the modal information and the modal sensitivity matrix to the parameter change. There are two cases this methodology is ill-equip to deal with; the deficiency of the necessary modal information and the ill-conditioning of the sensitivity matrix. In this research, a novel concept of the feedback exciter that uses the summation of the white noise and the signals from the measurement sensors multiplied with feedback gains as the reference signal is proposed. There are 2 advantages using this external feedback excitation. First, we can use the change of the system response such as modal data by the active energy Path from the sensor to the exciter. This change of the system response can be additional clues to the system dynamics that we want to know. Secondly, the external energy Path alternates the offset of the Parameter change to the system response. That means the modal sensitivity of the parameters becomes different from the original sensitivities by the feedback excitation. Through the feedback loop, we can change the similar modal sensitivities of some updating parameters and consequently discriminate the parameters using the closed-loop modal data. To demonstrate the discrimination performance, the parameter estimation of an indeterminate structure by use of the feedback method is introduced.

  • PDF

Passivity 기반 동기 발전기의 여자기 및 조속기 시스템의 제어 기법 (Passivity-based Control Approach of Exciter and Governor Systems for Synchronous Electric Generators)

  • 조현철
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.561-568
    • /
    • 2018
  • Passivity theory is significantly applied to analyze stability of nonlinear dynamic systems and construct its stable control systems. This paper presents a passivity based control design approach for exciters and governors which are employed to regulate the terminal voltage and the rotor velocity of synchronous generator systems in industry fields. We consider the IEEE type 1 exciter and the gas turbine (GT) governor models respectively in this paper. We first carry out a passivity analysis for exciter and governor control systems, which are numerically obtained from its mathematical models. And then its control parameters are selected to assure passivity conditions in a design procedure. Lastly, we investigate numerical simulations to demonstrate reliability of the proposed control approach against large-scale generators with parameter changes.

여자시스템의 파라미터가 터빈-발전기의 비틀림 스트레스에 미치는 영향 분석 (A Study on Effect of Exciter Parameters for the Torsional Stress of Turbine-Generator)

  • 김찬기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권8호
    • /
    • pp.420-426
    • /
    • 2003
  • This paper deals with the effect of exciter parameters on the torsional stress of turbine-generator. The excitation system effects on the AC network stability and the turbine-generator stress. However. it, until now, have not reported that any parameter among exciter parameters is related to the stability and the stress. In order to verify those CIGRE HVDC model was used. Since the AC network with HVDC has the voltage stability problem due to big capacitor, the worst condition to analyze the stress can considered. The EMTDC program is used for the simulation studies.

자기베어링 시스템을 가진기로 이용한 스퀴즈 필름 댐퍼의 동강성 계수 규명 (Identification of Dynamic Stiffness of Squeeze Film Damper using Active Magnetic Bearing System as an Exciter)

  • 김근주;이종원
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.381-387
    • /
    • 2002
  • In this work, the dynamic characteristics of an oil-lubricated, short SFD with a central feeding groove are derived based on a theoretical analysis considering the effect of a groove. The validity of the analysis is investigated experimentally using an Active Magnetic Bearing (AMB) system as an exciter. For the theoretical solution, the fluid film forces of a grooved SFD are analytically derived so that the dynamic coefficients of a SFD are expressed in terms of its design parameters. For the experimental validation of the analysis, a test rig using AMB as an exciter is proposed to identify the dynamic characteristics of a short SFD with a central groove. As an exciter, the AMB represents a mechatronic device to levitate and position the test journal without any mechanical contact, to generate relative motions of the journal inside the tested SFD and to measure the generated displacements during experiments with fairly high accuracy. Using this test rig, experiments are extensively conducted with different clearance, which is one of the most important design parameters, in order to investigate its effect on the dynamic characteristics and the performance of SFDs. Damping and inertia coefficients of the SFD that are experimentally identified are compared with the analytical results to demonstrate the effectiveness of the analysis. It is also shown that AMB is an ideal device for tests of SFDs.

  • PDF

수력 발전기 제어시스템의 계자상실 모델링과 시뮬레이션 (Modeling and Simulation of Loss of Excitation of Hydro Generator Control System)

  • 박철원
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.74-80
    • /
    • 2014
  • Generator protection device has to detects an internal fault conditions in generator and abnormal operating conditions must be due to the hazards. Loss of excitation may cause generator itself failure as well as serious operating problem in power system, and then requires an appropriate response of generator protection device. Details modeling of generator control system and analysis of transient states in generator are important for optimal operation in power plants. In addition, the fault simulation data are also used for testing the characteristics of IED. In this paper, the hydro generator control system using PSCAD/EMTDC, visual simulation for power systems, was modeled. The generator control system which is composed of generator, turbine, exciter, governor was implemented. The parameters of generator control system model were obtained from field power plant. Loss of excitation simulations were performed while varying the fixed load. Several signals analysis were also performed so as to analyze transients phenomena.

발전기 제어장치와 TCSC를 포함하는 이산 전력시스템의 고유치 감도해석 (Eigenvalue Sensitivity Analysis of Discrete Power Systems Including Generator Controllers and TCSC)

  • 김덕영
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.193-200
    • /
    • 2010
  • In this paper, the eigenvalue sensitivity analysis is calculated in the power system which is including both generator controllers such as Exciter, PSS and thyristor controlled FACTS devices in transmission lines such as TCSC. Exciter and PSS are continuously operating controllers but TCSC has a switching device which operates non-continuously. To analyze both continuous and non-continuous operating equipments, the RCF method one of the numerical analysis method in discrete time domain is applied using discrete models of the power system. Also the eigenvalue sensitivity calculation algorithm using state transition equations in discrete time domain is devised and applied to a sampled system. As a result of simulation, the eigenvalue sensitivity coefficients calculated using discrete system models in discrete time domain are changed periodically and showed different values compared to those of continuous system model in time domain by the effect of periodic switching operations of TCSC.

Drop 방식의 디지털 AVR을 이용한 1MVA급 선박용 동기발전기 제어 (1MVA synchronous generator control for vessel used for digital AVR of drop method)

  • 유동환;황춘환;박상훈;유재성;이상석;원충연
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.225-229
    • /
    • 2007
  • The output voltage of a synchronous generator is regulated constantly by field current control of excitation system. Synchronous generator exciter has two type, first one is Drop control type by thyristor and second one is exciter current control type through power output by PWM control. Control method of the second one prevails, but when the power devices have a breakdown, output voltage of the generator rises rapidly. This exciter must have a protection circuit and system is complicated, so reliability is poor Excitation control type which is drop control type control only 10% of the power, so it can be improved precision. When a trouble come to the controller, output voltage of a generator don't rise excessively and the voltage rise about 10%, so it has a excellent reliability. This paper prove stability of the digital AVR.

  • PDF

발전기 여자기시스템 주제어전원공급장치 국산화 개발 (The Development of EPSM(Exciter Power Supply Module) Localization in Generator Exciter(EX2100) System)

  • 이기선;박정철;추순남
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.101-107
    • /
    • 2016
  • The main target in this paper is the localization of VME Type EPSM in Generator Exciter(EX2100) System. Developed EPSM has the compatibility with the existing product in the structure and shape and electrical feature and so on, but it has a much improved capacity and reliability in comparison with origin company product. this paper, to improve these functions, put emphasis on protection, monitoring, power capacity increase(over 120%), an enlarged scale of input voltage supply, AC/DC dual voltage use and so on. After manufacturing product localization, it was carried out several tests for the performance and reliability verification of developed product. These tests were performed in Authorized Inspection Agency(KTL) and field application test and maker self-test were additionally performed. Finally, the results of all tests were "success".