• 제목/요약/키워드: Exchange current density

검색결과 148건 처리시간 0.033초

전기투석에 의한 니켈도금 폐수처리 공정에서 한계전류밀도와 불균질 이온교환막의 재생 (The Limiting Current Density and the Regeneration of a Heterogeneous Ion Exchange Membrane in a Nickel Plating Rinse Waters Treatment Process by Electrodialysis)

  • 윤용수
    • 환경위생공학
    • /
    • 제16권2호
    • /
    • pp.38-46
    • /
    • 2001
  • In this work, the heterogeneous ion exchange membrane was used in a electrodialysis apparatus to treat a Ni planting rinse water because the heterogeneous ion exchange membrane was excellent efficiency as compared with low manufacturing cost, was easy to make, and had a good mechanical properties. For a regeneration of membrane and to obtain the optimal condition for a scale-up of apparatus after treating Ni plating rinse water, we would find about the limiting current density and the concentration polarization. When the Ni plating rinse water 150mg/L was treated with the electrodialysis apparatus using the heterogeneous ion exchange membrane, the limiting current density was about $1.49{\;}mA/\textrm{cm}^2$. And the limiting current density increased with the flow rate and concentration of Ni plating rinse water. We recognized that the used membrane could be reused by periodic backwashing because efficiency was constant when the membrane was backwashed after treating wastewater.

  • PDF

A computer simulation of ion exchange membrane electrodialysis for concentration of seawater

  • Tanaka, Yoshinobu
    • Membrane and Water Treatment
    • /
    • 제1권1호
    • /
    • pp.13-37
    • /
    • 2010
  • The performance of an electrodialyzer for concentrating seawater is predicted by means of a computer simulation, which includes the following five steps; Step 1 mass transport; Step 2 current density distribution; Step 3 cell voltage; Step 4 NaCl concentration in a concentrated solution and energy consumption; Step 5 limiting current density. The program is developed on the basis of the following assumption; (1) Solution leakage and electric current leakage in an electrodialyzer are negligible. (2) Direct current electric resistance of a membrane includes the electric resistance of a boundary layer formed on the desalting surface of the membrane due to concentration polarization. (3) Frequency distribution of solution velocity ratio in desalting cells is equated by the normal distribution. (4) Current density i at x distant from the inlets of desalting cells is approximated by the quadratic equation. (5) Voltage difference between the electrodes at the entrance of desalting cells is equal to the value at the exits. (6) Limiting current density of an electrodialyzer is defined as average current density applied to an electrodialyzer when current density reaches the limit of an ion exchange membrane at the outlet of a desalting cell in which linear velocity and electrolyte concentration are the least. (7) Concentrated solutions are extracted from concentrating cells to the outside of the process. The validity of the computer simulation model is demonstrated by comparing the computed results with the performance of electrodialyzers operating in salt-manufacturing plants. The model makes it possible to discuss optimum specifications and operating conditions of a practical-scale electrodialyzer.

전류밀도와 전해질의 pH가 음이온교환막의 막 오염에 미치는 영향 (Effect of Current Density and pH of Electrolyte on Anion-Exchange Membrane Fouling)

  • 최재환
    • 대한환경공학회지
    • /
    • 제27권9호
    • /
    • pp.965-969
    • /
    • 2005
  • 이온교환막 공정의 중요한 운전인자인 전류밀도와 전해질의 pH가 막 오염에 미치는 영향을 연구하였다. 휴믹산 100 mg/L를 포함하고 있는 NaCl 용액에서 Neosepta AMX (Tokuyama Soda, Japan) 음이온교환막의 막 오염 현상을 관찰하였다. 한계전류밀도(LCD) 전 후 영역의 전류를 공급하면서 이온교환막의 전기저항 변화를 측정하여 막 오염 현상을 분석하였다. 실험결과 LCD 이하에서는 전류밀도의 변화가 막 오염에 큰 영향을 미치지 않았다. 그러나 LCD 이상의 전류밀도에서는 막 오염이 심각하게 진행되는 것으로 나타났다. 실험 후 휴믹산에 오염된 막에 대한 전류전압 곡선에서도 LCD 이상에서 실험한 경우에 막 오염으로 전기저항이 증가하고 LCD가 감소한 것을 알 수 있었다. 또한 휴믹산이 포함된 전해질 용액의 pH를 산성 조건으로 조정한 후 실험한 결과 pH가 감소할수록 막 오염이 증가하는 것으로 나타났다. 이 결과로부터 막 오염이 휴믹산의 표면 전하에 의한 것보다 물리화학적 성질에 더 큰 영향을 받는다는 것을 알 수 있었다.

고체산화물 연료전지를 위한 물성치 모델 및 단전지 해석 (Physical Property Models and Single Cells Analysis for Solid Oxide Fuel Cell)

  • 박준근;김선영;배중면
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.379-381
    • /
    • 2009
  • The simulation model for metal-supported Solid Oxide Fuel Cell(SOFC) is developed in this study. Open circuit voltage is calculated using Nernst equation and Gibbs free energy is required by thermodynamic. The exchange current densities are compared with experimental results since exchange current density is most effective factor for the activation loss. Liu's study is used for the exchange current density of cathode, BSCF, and Koide's result is applied for the exchange current density of anode, Ni/YSZ. For the ohmic loss, ionic conductivity of YSZ is described from Kilner's mode and the data are compared with Wanzenberg's experimental data. Diffusivity is an important factor for the mass transfer through the porous medium. Both binary diffusion and Knudsen diffusion are considered as the diffusion mechanism. For validation, simulation results at this work are compared with our experimental results.

  • PDF

한계전류밀도 이상에서 전기투석공정의 운전 (Operation of Electrodialysis at Over Limiting Current Density)

  • 박진수;최재환;문승현
    • 멤브레인
    • /
    • 제12권3호
    • /
    • pp.171-181
    • /
    • 2002
  • 이온교환막의 전압-전류곡선의 plateau length를 결정하는 변수를 다양한 NaCl 농도와 유속 하에서 연구하였다. 또한, 한계전류밀도 이상의 전류에서 전기투석공정 운전의 타당성을 검토하기 위해 다양한 전류밀도의 전원을 공급하면서 0.1 M NaCl 용액의 탈염실험을 실시하여 이온의 제거효율, 전류효율, 에너지소비량, 물 분해 현상을 측정하였다. NaCl 용액의 농도와 유속이 감소하면서 확산경계층의 두께도 함께 감소하였으며, 본 확산경계층의 두께는 plateau length와도 밀접한 관련이 있는 것으로 나타났다. 탈염실험에서 측정된 이온 제거 효율 및 전류효율은 한계전류밀도 이상에서도 한계전류밀도 이하에서의 탈염실험과 크게 차이 나지 않은 것으로 보아 한계전류밀도 이상에서도 대부분의 전류는 이온교환막 표면의 물분해에 의한 것이 아니라 막을 통한 이온의 이동에 의한 것으로 사료된다. 한계전류밀도 이상에서의 탈염운전에 대한 에너지소비량은 plateau length의 영향으로 한계전류밀도 이하에서의 탈염운전 보다 다소 높지만, 한계전류밀도 이상에서는 전류밀도의 증가에도 에너지소비량이 증가하지 않았다. 이러한 결과들은 물분해 현상이 심각하게 일어나지 않는 한 한계전류밀도 이상에서도 매우 경제적으로 전기투석 공정을 운전찬 수 있다는 것을 제시해 주는 것이다.

금속지지체형 고체산화물 연료전지의 단전지 특성 및 전산해석 (Single cell property and numerical analysis of metal-supported solid oxide fuel cell)

  • 이창보;배중면
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2222-2227
    • /
    • 2007
  • Newly structured metal-supported solid oxide fuel cell was fabricated and characterized by impedance analysis and galvanodynamic experiment. Using a cermet adhesive, thin ceramic layer composed of anode(Ni/YSZ) and electrolyte(YSZ) was joined with STS430 metal support of which flow channel was fabricated. $La_{0.8}Sr_{0.2}Co_{0.4}Mn_{0.6}O_3$ perovskite oxide was used as cathode material. Single cell performance was increased and saturated at operating time to 300hours at 800$^{\circ}C$ because of cathode sintering effect. The sintering effect was reinvestigated by half cell test and exchange current density was measured as 0.005A/$cm^2$. Maximum power density of the cell was 0.09W/$cm^2$ at 800$^{\circ}C$. Numerical analysis was carried out to classify main factors influencing the single cell performances. Compared to experimental IV curve, simulated curve based on experimental parameters such as exchange current density was in good agreement.

  • PDF

전류밀도와 전기삼투 현상이 전기투석 공정의 탈염성능에 미치는 영향 (Effect of Current Density and Electroosmotic Phenomena on the Desalination Performance of the Electrodialysis Process)

  • 천은서;최재환
    • 공업화학
    • /
    • 제34권3호
    • /
    • pp.272-278
    • /
    • 2023
  • 이 연구에서는 전류밀도와 전기삼투 현상이 전기투석(electrodialysis, ED)의 탈염성능에 미치는 영향을 분석하였다. 농축액의 농도를 10~200 g/L로 변화시키면서 정전압 조건에서 ED 실험을 진행하였다. ED 운전과정에서 스택에 공급되는 전류밀도와 전하량, 희석액과 농축액의 농도, 그리고 전기삼투에 의한 물 이동량을 측정하여 탈염성능을 분석하였다. 농축액의 농도가 증가함에 따라 이온교환막의 선택성이 감소하여 전류효율이 감소하였다. 또한 전류효율은 스택에 공급되는 전류밀도에 영향을 받는 것으로 나타났다. 전류밀도가 15 mA/cm2 이상에서는 역 확산이 억제되어 전류효율이 증가하였다. ED 운전과정에서 전기삼투에 의한 물 이동량을 분석하였다. 물 이동량은 농축액과 희석액의 농도비에 비례하여 증가하는 것을 알 수 있었다. 농도비가 100 이상에서는 삼투압에 의한 물 이동량이 급격히 증가하여 200 g/L 이상의 농축액을 얻는데 한계가 있는 것으로 나타났다.

Effects of Sulfuric Acid Concentration and Alloying Elements on the Corrosion Resistance of Cu-bearing low Alloy Steels

  • Kim, Ki Tae;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • 제17권4호
    • /
    • pp.154-165
    • /
    • 2018
  • During the process of sulfur dioxide removal, flue gas desulfurization equipment provides a serious internal corrosion environment in creating sulfuric acid dew point corrosion. Therefore, the utilities must use the excellent corrosion resistance of steel desulfurization facilities in the atmosphere. Until now, the trend in developing anti-sulfuric acid steels was essentially the addition of Cu, in order to improve the corrosion resistance. The experimental alloy used in this study is Fe-0.03C-1.0Mn-0.3Si-0.15Ni-0.31Cu alloys to which Ru, Zn and Ta were added. In order to investigate the effect of $H_2SO_4$ concentration and the alloying elements, chemical and electrochemical corrosion tests were performed. In a low concentration of $H_2SO_4$ solution, the major factor affecting the corrosion rate of low alloy steels was the exchange current density for $H^+/H_2$ reaction, while in a high concentration of $H_2SO_4$ solution, the major factors were the thin and dense passive film and resulting passivation behavior. The alloying elements reducing the exchange current density in low concentration of $H_2SO_4$, and the alloying elements decreasing the passive current density in high concentration of $H_2SO_4$, together play an important role in determining the corrosion rate of Cu-bearing low alloy steels in a wide range of $H_2SO_4$ solution.

수치실험을 통한 금오열도 해역의 해수유동 특성 (Flow characteristics of Geumo Islands Sea area by numerical model experiments)

  • 추효상
    • 수산해양기술연구
    • /
    • 제58권2호
    • /
    • pp.159-174
    • /
    • 2022
  • Flow prediction was carried out through observational survey and three dimensional multi-layered numerical diagnostic model experiment to clarify the time and spatial structure of tidal current and residual flow dominant in the sea exchange and material circulation of the waters around Geumo Islands in the southern waters of Korea. The horizontal variation of tidal current is so large that it causes asymmetric tidal mixing due to horizontal eddies and the topographical effect creating convergence and dispersion of flow direction and velocity. Due to strong tidal currents flowing northwest-southeast, counterclockwise and clockwise eddies are formed on the left and right sides of the south of Sori Island. These topographical eddies are created by horizontal turbulence and bottom friction causing nonlinear effects. Baroclinic density flows are less than 5 cm/s at coastal area in summer and the entire sea area in winter. The wind driven currents assuming summer and winter seasonal winds are also less than 5 cm/s and the current flow rate is high in winter. Density current in summer and wind driven current in winter have a relatively greater effect on the net residual flows (tidal residual current + density current + density driven current) around Geumo Islands Sea area.

Synthesis of Cation-Exchange Membrane by the Monomer Sorption

  • Park, Yong-Jin;Moon, Seung-Hyeon
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 The 4th Korea-Italy Workshop
    • /
    • pp.1-4
    • /
    • 2003
  • LDPE/polystyrene cation exchange membranes were prepared through a monomer-sorption method and UV radiation polymerization. The reaction behaviors in the preparation were investigated. The membranes prepared were characterized in terms of physical and electrochemical properties. The membranes exhibited reasonable properties for an ion-exchange membrane with weight gain (Wr) of above 0.3, electrical resistance of below 1.0 Ω $\textrm{cm}^2$ and ion-exchange capacity of 1.8 meq/g-dry membrane. DSC studies and FE-SEM image revealed the formation of a homogeneous membrane. Both the current-voltage and the chronopotentiometric curves of the membranes indicated that LDPE/polystyrene membranes can be properly used at a high current density, and the surface homogeneity of cation-exchange sites in the membrane was comparable to that in a commercial membrane.

  • PDF