The Limiting Current Density and the Regeneration of a Heterogeneous Ion Exchange Membrane in a Nickel Plating Rinse Waters Treatment Process by Electrodialysis

전기투석에 의한 니켈도금 폐수처리 공정에서 한계전류밀도와 불균질 이온교환막의 재생

  • 윤용수 (단국대학교 화학공학과)
  • Published : 2001.06.01

Abstract

In this work, the heterogeneous ion exchange membrane was used in a electrodialysis apparatus to treat a Ni planting rinse water because the heterogeneous ion exchange membrane was excellent efficiency as compared with low manufacturing cost, was easy to make, and had a good mechanical properties. For a regeneration of membrane and to obtain the optimal condition for a scale-up of apparatus after treating Ni plating rinse water, we would find about the limiting current density and the concentration polarization. When the Ni plating rinse water 150mg/L was treated with the electrodialysis apparatus using the heterogeneous ion exchange membrane, the limiting current density was about $1.49{\;}mA/\textrm{cm}^2$. And the limiting current density increased with the flow rate and concentration of Ni plating rinse water. We recognized that the used membrane could be reused by periodic backwashing because efficiency was constant when the membrane was backwashed after treating wastewater.

Keywords

References

  1. he Use Of Membrane Process in Environmental Problem in Membrane Process in Separation And Purification Marcel Mulder
  2. Desalination v.101 Wisinewski, J.;Suder, S.
  3. Comparative Economics, plating v.55 Metal Finishing waste Treatment Yuronis, D.
  4. J. Membrane Sci. v.127 Kesore, K.;Janowski, K.;Shaposhnik, V.A.
  5. Membrane Separation Process Partrick Mears(ed.)
  6. Soviet Electrochemistry v.28 Pevintskaya, M.V.