• Title/Summary/Keyword: Excess parameters

검색결과 305건 처리시간 0.028초

수질오염총량관리 대상물질 선정을 위한 하천수질 평가 (Evaluation of Stream Water Quality to Select Target Indicators for the Management of Total Maximum Daily Loads)

  • 박준대;박재홍;오승영;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.630-640
    • /
    • 2013
  • It is one of the most critical steps identifying impaired waterbodies exactly in the selection of target water quality indicators for the management of Total Maximum Daily Loads (TMDLs). Excess ratio and excess level were applied and analyzed by the stream zone basis in order to evaluate water impairment for Nakdong, Geum, Youngsan and Seomjin rivers. Each river basin was divided into stream zones in the light of its watershed and waterbody characteristics. Selected water quality parameters discussed in this study were pH, DO, BOD, COD, SS, T-P, T-Coli and F-Coli. The excess ratios of the water quality parameters were used to discriminate water bodies that did not meet water quality standards. The excess levels were used to classify the degradation of water quality. The excess ratios and the excess levels to the water quality criteria of the medium influence areas were used for each stream zone. The results indicate that the excess ratios and the excess levels are varied on the stream zone in each river basin. Three parameters, pH, DO and SS, met water quality standards in all stream zones. The other five parameters indicated very high excess ratios in most waterbodies, and especially T-P and T-Coli revealed to be very high excess levels in some waterbodies. These parameters could be considered as major target indicators for the management of TMDLs.

Study of Dynamics of Allyl Chloride-2-Butanone Binary System Using Time Domain Reflectometry

  • Sudake, Y.S.;Kamble, S.P.;Patil, S.S.;Khirade, P.W.;Mehrotra, S.C.
    • 대한화학회지
    • /
    • 제56권1호
    • /
    • pp.20-27
    • /
    • 2012
  • Complex permittivity spectra of Allyl Chloride (AC), 2-Butanone (2-BU) and their binary mixtures over the entire range of concentration were obtained using the Time Domain Reflectometry (TDR) technique in microwave frequency range at various temperatures. Static dielectric constant and relaxation time are obtained from complex permittivity spectra. Density ($\rho$) and refractive index ($n_D$) are also measured. These parameters are used to determine excess dielectric constant, excess inverse relaxation time, excess molar volume, excess molar refraction, polarity, Bruggeman factor and thermodynamic parameters viz. enthalpy of activation and entropy of activation. The values of static dielectric constant and relaxation time increases while density and refractive index decreases with the percentage of 2-Butanone in Allyl Chloride increases. Excess parameters were fitted to a Redlich-Kister equation.

상온 및 상압하에서 3성분계 {1,2-dichloropropane + 1,3-dioxolne + 1,4-dioxane}의 과잉 몰엔탈피 예측 (Excess Molar Enthalpies for the Ternary System {1,2-dichloropropane + 1,3-dioxolne + 1,4-dioxane} at T=298.15 K and p=101.3 kPa)

  • 이영세;김문갑
    • 한국산업융합학회 논문집
    • /
    • 제14권1호
    • /
    • pp.9-14
    • /
    • 2011
  • The excess molar enthalpies $H_m^E$ at T=298.15 K and p=101.3 kPa of ternary system {1,2-dichloropropane (1,2-DCP) + 1,3-dioxolane+ 1,4-dioxane} were predicted by using the binary contribution model of $Radojkovi{\check{c}}$ with correlated sub-binary Redlich-Kister parameters. Excess partial molar enthalpies ${\bar{H}}_i^E$ were also calculated for the binary systems {1,2-dichloropropane + 1,3-dioxolane}, {1,2-dichloropropane + 1,4-dioxane} and {1,3-dioxolane + 1,4-dioxane} using adjustable parameters of Redlich-Kister equation. By extrapolation of excess partial molar enthalpies to infinite dilution, limiting excess partial molar enthalpies ${\bar{H}}_i^{E,{\infty}}$ of each component were also obtained. The ternary excess molar enthalpies excess partial molar enthalpies of these sub-binary systems have been calculated by using our previously reported results.

접착이음의 계면덧살에 대한 응력특이성 해석 (Analysis of Stress Singularity for the Excess Adhesive of Interface in Adhesively Bonded Joint)

  • 정남용;박철희
    • 한국생산제조학회지
    • /
    • 제21권3호
    • /
    • pp.439-445
    • /
    • 2012
  • The stress singularity for the excess adhesive on interface of adhesively bonded joint was investigated by using the 2-dimensional elastic boundary element method (BEM). To establish a reasonable strength evaluation method and a fracture criterion for the excess adhesive of interface in adhesively bonded joint, it is necessary to evaluate fracture parameters with various bonding conditions. Under the variations of adhesively bonded thickness (h) and diameter (d) for the excess adhesive, a stress analysis was performed, and from the results, the stress singularity index (${\lambda}$) and the stress singularity factor (${\Gamma}$) were calculated. The variations have a great influences on the stress singularity for the excess adhesive of interface in adhesively bonded joint, and the ${\Gamma}$ is reduced as the "h" and "d" increase.

등온 미세열량계를 이용한 n-Hexane-알칸계 이성분 혼합물 및 NaOH/Water/Ethanol계의 과잉 엔탈피 측정 및 계산 (Measurement and Calculation of Excess Enthalpies for n-Hexane/Alkane series and NaOH/Water/Ethanol System using Isothermal Microcalorimeter)

  • 최인규;유성식
    • Korean Chemical Engineering Research
    • /
    • 제55권5호
    • /
    • pp.660-667
    • /
    • 2017
  • 화학공정에서 증류 또는 추출 등 분리 장치의 설계 및 조업에 있어서 혼합물의 평형데이터는 필수적이다. 이들 평형데이터는 실험을 통해서 얻거나 알려진 이성분 매개변수를 이용하여 모델에 의한 계산으로 얻을 수 있다. 일반적으로 이들 매개변수를 구하기 위해서 기-액, 액-액 등의 상평형 실험 데이터를 주로 이용하지만, 본 연구에서는 보다 간편한 방법으로서 흐름형 미세열량계를 이용하여 혼합물의 과잉엔탈피 실험데이터를 얻고, 이 데이터를 이용하여 여러 이론들의 매개변수를 구하고자 하였다. 더불어, 알칸계의 경우 탄소의 사슬길이와 엔탈피 그리고 이성분 매개변수간의 관계를 알아보고자 하였으므로 n-hexane + alkane (n-pentane, n-heptane, n-octane, n-dodecane)계들에 대해서 298.15 K에서 과잉엔탈피를 측정하였으며, 이 실험데이터로부터 Wilson, NRTL, UNIQUAC의 매개변수를 구하였다. 또한, 다양한 분야에 적용 가능한 전해질 계의 상호작용 및 회합현상에 대한 기본정보를 과잉엔탈피 실험 데이터들과 기존 이론을 이용하여 얻고자 하였다. 우선은 기초적인 실험으로서 NaOH/Water/Ethanol 계에 대한 과잉 엔탈피를 측정하고, electrolyte-NRTL(eNRTL) 이론을 이용하여 응용성을 검토하고자 하였다.

298.15~318.15 K 에서 2-브로모프로판-메탄올 이성분 혼합물의 밀도, 점성도, 여분 성질 (Densities, Viscosities and Excess Properties of 2-Bromopropane - Methanol Binary Mixtures at Temperature from (298.15 to 318.15) K)

  • Li, Hua;Zhang, Zhen;Zhao, Lei
    • 대한화학회지
    • /
    • 제54권1호
    • /
    • pp.71-76
    • /
    • 2010
  • 298.15~318.15 K 온도에서 디지탈 진동 U-tube densimeter 와 Ubbelohde 모세관 점성계을 사용하여 2-브로모프로판/메탄올 이성분 혼합물의 밀도와 점성도를 측정하였다. 온도와 농도에 대한 밀도와 점성도 상호 의존 관계를 조사하였다. 이성분 혼합물의 여분 몰부피와 여분 점성도를 실험으로 얻어진 밀도와 점성돌로부터 계산하여 구하였다. 모델이 실험치와 잘부합됨을 발견하였다.

Ionospheric Correction for retrieving atmospheric variables from GPS occultation data

  • Huang Cheng-Yung;Liou Yuei-An
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.43-46
    • /
    • 2005
  • [1] There are systematical errors associated with ionospheric influence in retrieving key atmospheric parameters from radio occultation (RO) soundings. In order to obtain better-quality retrievals, we develop a new method, hereafter called National Central University Radio Occultation (NCURO) scheme, to reduce the ionospheric influence. The excess phase is divided into two parts, namely geometric excess length and path excess length (excess length along ray path due to refractivity effect). An excess phase equation is presented and implemented in the NCURO scheme Whose performance is evaluated through comparisons with model simulation and experimental data. The model simulation is based on the use of the ionospheric model 002001 and atmospheric model NRLMSISE-OO. Results show that the NCURO scheme significantly reduces the ionospheric influence at altitudes above 70 km as does the scheme presented in the literature, and provides better corrections for the atmospheric profile. INDEX TERMS: 2400 Ionosphere: Ionosphere; 6964 Radio Science: Radio wave propagation; 6969 Radio Science: Remote sensing.

  • PDF

CO2 용접에서 용접변수의 변화에 따른 용접흄 제어방법에 관한 연구 (A Study on Control of Fume for Various Parameters in CO2 Welding)

  • 오광중;김현수;손병현;지해성
    • 한국산업보건학회지
    • /
    • 제8권1호
    • /
    • pp.76-87
    • /
    • 1998
  • The concentration of welding fume was measured by 221 welders themselves in chassis frame workplace of the manufactory from February, 1, 1996 to May, 31, 1997. Welding parameters were the welding current and the distance between helmet and arc. Those two optimum conditions were proposed by excess probability analysis using logistic regression, so the best position in the workplace was proposed considering two factors to control the welding fume. The results are as followings; 1) The excess proability of welding fume TLV was over 99% in above 260 Amperes of welding current and also in below 30cm of distanced between helmet and arc. 2) The equation from logistic regression analysis using SPSS/PC+5.02 had the welding current as a independent variable and the excess of welding fume TLV as a dependent variable (p<0.05). Logit(welding fume TLV) = 0.1296 ${\times}$ wlding currnet - 28.8750 3) The equation from logistic regression analysis using SPSS/PC+5.02 had the distance between helmet and arc as a independent variable and the excess of welding fume threshold limit value a, a dependent variable (p<0.05). Logit (welding fume TLV) = -0.6809 ${\times}$ distance between helmet and arc +25.1665 4) Considering both cases or 2) and 3). the result equation is following. (p<0.05). Logit (welding fume TLV) = 0.1346 ${\times}$ welding current -0.3859 ${\times}$ distance between helmet and arc -15.7382 5) The excess probability of welding fume threshold limit value was 100% in above 240 Ampere of welding current. Thus, below 220 Ampere can be suggested to reduce the 40% number of welders who have a excess welding fume threshold limit value. 6) The excess probability of welding fume TLV was 100% in below 34cm of distance between helmet and arc. Thus, over 38cm can be suggested to reduce the 33% number of welders who have a excess welding fume TLV. 7) Considering both 5) and 6) cases, first of all, the best welding current can be 200 Ampere to have a below 15% of welding fume excess probability for the welders who works in distance of 34-37cm. Secondly, to have a below 30% excess probability of welding fume TLV, the working distance must be over 38cm in 220 Ampere and 32cm in 200 Ampere. 8) To reduce the average exposure concentration of welding fume ($8.21{\pm}5.83mg/m^3$), the movable local exhaust system equipped with flexible hoods can be used.

  • PDF

Static Dielectric Constant and Relaxation Time for the Binary Mixture of Water, Ethanol, N. N-Dimethylformamide, Dimethylsulphoxide, and N, M-Dimethylacetamide with 20Hethoxyethanol

  • Ajay Chaudgari;N. M. More;S. C. Mehrotra
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권4호
    • /
    • pp.357-361
    • /
    • 2001
  • Frequency spectra of the complex permittivity of 2-methoxyethanol (2-ME) with water, ethanol, dimethylsulphoxide (DMSO), N,N-dimethylformamide (DMF) and N,N-dimethylacatamide (DMA) have been determined over the frequency range of 10 MHz to 20 GHz at 25 $^{\circ}C$, using the Time domain reflectometry method, for 11 concentrations for each system. The static dielectric constant, dielectric constant at microwave frequency, relaxation time, excess dielectric parameters, and Kirkwood correlation factor have been determined. The relaxation in these systems within the frequency range can be described by a single relaxation time constant, using the Debye model. The parameters show a systematic change with the concentration.

능동 소나 체계에서의 표적 탐지거리 예측 알고리즘과 최적 탐지깊이 결정에의 응용 (Detection Range Estimation Algorithm for Active SONAR System and Application to the Determination of Optimal Search Depth)

  • 박재은;김재수
    • 한국해양공학회지
    • /
    • 제8권1호
    • /
    • pp.62-70
    • /
    • 1994
  • In order to estimate the detection range of a active SONAR system, the SONAR equation is commonly used. In this paper, an algorithm to calculate detection range in active SONAR system as function of SONAR depth and target depth is presented. For given SONAR parameters and environment, the transmission loss and background level are found, signal excess is computed. Using log-normal distribution, signal excess is converted to detection probability at each range. Then, the detection range is obtained by integrating the detection probability as function of range for each depth. The proposed algorithm have been applied to the case of omni-directional source with center frequency 30Hz for summer and winter sound profiles. It is found that the optimal search depth is the source depth since the detection range increase at source depth where the signal excess is maximized.

  • PDF