미국 외래진료시설의 시대적 변천과 공간적 특성에 관한 연구 (A Chronological Study on the Transformation and the Spatial Characteristics of Ambulatory Care Facilities in the United States)

  • 이수경;최윤경
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제25권2호
    • /
    • pp.51-62
    • /
    • 2019
  • Purpose: This study aims to examine spatial characteristics of ambulatory care department Chronologically through case studies; and to consider the social implication of these spatial changes. Methods: In this study, a total of eight ambulatory care departments, one or two for each period, were selected in order to analyze the spatial characteristics. Results: First, since the 1990s, the outpatient department of the US has been changed into a patient-centered space by providing high quality outpatient medical services through individual exam room planning. Second, the exam room has been changed from open/semi-open/group exam room to individual exam room since 1990, and the trend is shifting from the cluster type to the modular type consisting of universal exam rooms in order to achieve the flexibility of exam room. Third, the diagnostic/testing area has been deployed to the ambulatory clinic to enable 'one-stop shopping' for patients-centered care since 1990s, however, it has been disappearing since 2000 due to Reduce medical expenses. Fourth, the Central Nursing Station type first appeared in the outpatient department In the 2000s, followed by the type of decentralized nursing station type since 2010s. And fifth, the area of medical support has been placing to be concentrated on one place due to the Lean Design strategy since 2010. Implications: In the future, it is expected that Korea will be more focused on efficiency, visual control, and flexibility in the planning of the ambulatory care department as in the case of the United States.

호흡기 감염병 예방을 위한 보건소 상시 선별진료소 활용방안 연구 - 음압 결핵 검진실을 중심으로 (A Study on a space utilization plan for screening clinic in public health center by means of the prevention of respiratory infectious disease - Focused on a negative pressured tuberculosis exam room)

  • 윤형진;한수하
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제27권4호
    • /
    • pp.51-60
    • /
    • 2021
  • Purpose: Tuberculosis(TB) care unit in public health center should be carefully considered to be re-designed as an infection safety environment for both patient and healthcare workers. So, for the enhancement, this study analyses the facility requirements for co-using the screening clinic as a TB and other respiratory disease care unit. Methods: Not only screening clinic facility guidelines from "A Study for Standard Triage Design and Construction Document" but also the guidelines of TB care and related medical facility are reviewed; KDCA, CDC, ECDC and WHO as a TB care, and FGI and NHS for facility. The facility requirements are summarized space, approach, and mechanical requirement in order. By comparing the summary and screening clinic facility guidelines, supplementations are proposed for TB care unit setting. Results: The result of this study shows that both the space program and mechanical requirement of the screening clinic and that of TB care unit are almost identical and could be share, which include direct airflow or negative air pressure in an exam room. To increase functional and economical efficiency, however, it is necessary to consider a multi-functional negative pressured room, So care process may be re-designed based on a room type; face-to-face room or glass wall inbetween. Implications: The facility guidelines for TB care unit of a public health center should be developed to build a safe environment for infection control by reflecting its medical plan and budget.

Computed Radiography 환경에서의 REPEAT 유형변화에 대한 고찰

  • 안미섭;장광현;문희석;정환
    • 대한디지털의료영상학회논문지
    • /
    • 제3권1호
    • /
    • pp.52-58
    • /
    • 1997
  • Before entering 21st Century, modern medical science is requiring more precise display which is highly estimated in diagnostic value as radial science technology is achieving sharp development. And it is also trying to contribute to improve national health and to offer better service by reducing radial exposure. General projection and Fluoroscopy which are most difficult to be displayed in digital tend to change their way ; from analog to digital with development of Electronic Engineering and Computer Technology, Introducing to CR system in 1994, SMC have displayed General projection and Fluoroscopy 100% in digital using CR system. This study searched differences between repeat rate, repeat type in the exam using Film/Screen and those in the exam using CR system. According to the analysis of repeat types and repeat rate of Film which was reused by using CR system in general projection room and Fluoroscopy room of SMC, we found that total 192,813 films were used and 2,097 films, 1.09% of total were reused. However, actual repeat covers 0.76% to 1,461 sheets with the exception of 636sheets. As above, display process using CR system is 0.76% much lower than general repeat rate 2$\sim$4% of Film/Screen exam. Besides decreased under/over exposure, it is appeared that position failure rate in repeat rate 0.76% covers relatively high 31%. Noticing that repeat caused unskilled devices handing was found many times, sufficient understanding seems to be required to reduce repeat.

  • PDF

성형외과의원의 공간구성과 면적산정에 관한 연구 - 강남구 사례분석을 중심으로 - (A study on the Spatial Composition and Area Calculation in the Plastic Surgical Clinics -Focused on case studies in Kangnam-Gu)

  • 이용길;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제7권1호
    • /
    • pp.33-44
    • /
    • 2001
  • This study is about the Spatial Composition and Area Calculation in Plastic Surgical Clinics. 1. The space of the plastic surgical clinics are divided into 4 sections; exam, exam support, the staffs, and waiting and reception area. 2. The average G/N ratio of width was 1.46. The Plastic surgical clinics which had great deviation in the ratio showed these characteristics; first, when they were planned at first, the operation rooms were not assigned enough space; second. space for supporting exam and the activities of staffs was given too little consideration in their first drafts. 3. The average size of operation rooms was $21.76m^2$. The most desirable size was found to be $26.4m^2$ when we put the number of staffs, the movement area of stretcher, and the movement lines of operation room into consideration.

  • PDF

안면부 봉와직염으로 인한 패혈증으로 사망한 증례 (Death according to sepsis due to facial cellulitis: A case report)

  • 김지홍;김영균
    • 대한치과의사협회지
    • /
    • 제38권12호통권379호
    • /
    • pp.1172-1177
    • /
    • 2000
  • Eighty nine-year-old female patient admitted to our department via emergency room. On initial exam, she showed right facial swelling, irismus, pain, and poor oral hygiene. Tentative diagnosis was facial cellulitis. In spite of aggressive treatment such as antibiotic, incision and drainage, medically intensive therapy, she was dead with cardiopulmonary arrest and sepsis.

  • PDF

유방촬영시 관찰조건에 따른 임상영상평가 (Evaluation of Clinical Image on Observational Condition in Mammography)

  • 김미현;김창복;지연상;동경래
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.89-95
    • /
    • 2010
  • High contrast and high resolution are the most important factors for examining mammography images. Despite of the inconveniences of screen-film, most clinics still prefer them to computed radiography(CR) and direct radiography(DR). The reading of screen-film mammography images is influenced by the brightness from the X-ray illuminator, the exam room and incoming light from outside sources. Therefore, a comparative analysis on the results of mammo phantom images would be variated by the changes in the reading environment. There was no influence on reading results from the examiners close distance eyesight(p > 0.05); however, reading of micro lesions improved with greater darkness in the X-ray film reading room and the brightness of the X-ray illuminator(p < 0.05). Also, observation of fiber and mass images were maximized at a distance of 50 cm from the reader. Now, it is possible to observe these small classification groups using a magnifying glass without being physically close to the image. For the image of mammography, obtaining high quality images is important but in order to get an accurate clinical lesions of the reading also needs to be considered the optimal environmental factors.

  • PDF

부부의 노동분담에 대한 시간대별 활동 및 공간활용도 분석 (An Analysis on Husbands and Wives' Time Distribution and Space Occupancy in the Division of Labor)

  • 윤소영
    • 가족자원경영과 정책
    • /
    • 제9권4호
    • /
    • pp.21-40
    • /
    • 2005
  • The purpose of this study was to exam the activities by the distribution of time and space occupancy on their weekday and weekend. to study the space and labor segregation by sex. The sample population included 23 wives and their husbands(30-40 years old). The major findings of the research are as follows: First, it shows that wives' time use by activity was consistent with the space occupancy on weekday. Second, on weekend, wives was used to stay in living room most of time. Thirdly, husbands show the stereotype of time use on weekday, and substitute leisure time for labor time. Finally, on weekend, the wives and husbands have the joint time in the household labor or leisure activities.

  • PDF

자기공명영상(MRI) 검사 시 방사선사의 소음노출 (Noise Exposure of Radiographer Caused by Magnetic Resonance Imaging(MRI))

  • 길종원
    • 한국콘텐츠학회논문지
    • /
    • 제16권11호
    • /
    • pp.699-706
    • /
    • 2016
  • 본 연구는 MRI 검사로 인하여 방사선사가 노출되는 소음의 양을 평가하여 소음저감 시설의 필요성과 제도 마련을 제안하고자 하였다. 소음측정은 대전광역시 S 종합병원의 1.5 Tesla MRI 장비(7개 검사)와 3.0 Tesla MRI 장비(16개 검사)를 대상으로 하였고, 소음측정기는 SC-804를 사용하였다. 소음측정 거리는 MRI 검사실 방음문에서 검사자의 업무 위치까지 100cm 이며, 측정 높이는 업무 시 검사자의 귀 높이 100cm 이다. 검사별 소음측정은 각 검사의 시퀀스(Sequence)마다 발생되는 소음 수치를 관측하여 20초마다 기록하였고 검사별 3회씩 측정하여 평균값을 제시하였다. 연구결과 방사선사가 노출되는 소음의 최댓값은 73.3 dB(A)로 3.0 Tesla 장비에서 시행한 MRCP 검사, 검사별 평균소음의 최댓값은 66.9(3.1) dB(A)로 역시 3.0 Tesla 장비에서 시행한 Myelogram 검사이다. 장비별 평균소음은 3.0 Tesla 장비가 61.9(4.1) dB(A), 1.5 Tesla 장비가 52.0(3.1) dB(A)로 3.0 Tesla MRI 장비가 약 10 dB(A) 정도 높았다(p<0.001). 방사선사가 노출되는 소음의 양은 청력에 영향을 미치는 수준은 아니지만 비청력적영향이 발생할 수 있는 수준이다. 소음을 저감하기 위해 MRI 조정실 후면에 커튼을 설치하여 반사음을 제거할 수 있지만, 제도 마련이 선행되어야 할 것이다.

요양시설 치매노인의 배회행동 (Wandering Behavior in Korean Elders with Dementia Residing in Nursing Homes)

  • 송준아;임영미;홍(손)귀령
    • 대한간호학회지
    • /
    • 제38권1호
    • /
    • pp.29-38
    • /
    • 2008
  • Purpose: This study investigated various factors relatied to wandering behavior of Korean elders with dementia (KED). Methods: A sample of 160 ambulatory residents with dementia from 14 long term care facilities was used to examine demographic, individual, cognitive, physical health, and environmental characteristics by comparing wanderers (N=108) to nonwanders (N=52). Subjects were evaluated by Korean versions of the Mini-mental State Exam (K-MMSE), the Physical and Instrumental Activities of Daily Living (K-PIADL), and the Revised Algase Wandering Scale Nursing Home version (KRAWS-NH) along its six dimensions. Demographic and environmental data were also obtained. Independent sample t-tests, Chi-square test, Fisher's Exact tests, and ANCOVAs were used to examine differences between wanderers and nonwanders. Results: Wanderers were significantly (p<.05) older and had more limitations in K-PADL and K-IADL. The degree of overall wandering and certain features of wandering were significantly different (p<.05) by total number of residents in the facility, type of bedroom (i.e., "Ondol"), and color of bedroom and living-room walls (i.e., sky blue). Conclusions: Findings of this study may be useful in understanding wandering behavior of KEDs and thus developing more culturally specific management strategies.

전문대학 간호과 전공심화과정 운영방안 (A Study on Intensive Major Course of Department of Nursing in College)

  • 박송자;제미순
    • 한국간호교육학회지
    • /
    • 제10권1호
    • /
    • pp.64-74
    • /
    • 2004
  • This study was conducted to investigate what contents nurses want in the intensive major course of junior nursing college. Data were collected for four months from October 2002 to February 2003 by structured questionnaires. Subjects were 240 registered nurses in working at five hospitals and four public health centers and elementary or middle schools in the capital and its suburbs and country. The collected data were analyzed using SPSS 8.0 program. The results of this study were summarized as follows : 1. Nurses working at hospitals want the programs which involve the contents as follows : emergency nursing/CPR, infection control, critical care, caner pt. care, pain control, hospice, pulmonary disease pt. care, analysis of lab. exam, heart disease pt. care, chronic disease pt. care, DM pt. care, digestive-system disease pt. care, nervous-system disease pt. care, elderly pt. care, immune-system disease pt. care, endocrine-system disease pt. care. 2. Nurses working at public health centers want the programs which involve the contents as follows : home nursing, family nursing, management of DM, HT, degenerative disease, and chronic liver disease, elderly pt. care, health education, maternity nursing, rehabilitation nursing. 3. Nurses working at elementary or middle schools want the programs which involve the contents as follows : prevention of drug abuse or misuse, sex education and consultation, health education, consultation technique, emergency care, prevention of child obesity, prevention and management of adult disease in children, teaching method, method of school health room management.

  • PDF