• Title/Summary/Keyword: Exact confidence interval

Search Result 53, Processing Time 0.017 seconds

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

Validating a New Approach to Quantify Posterior Corneal Curvature in Vivo (각막 후면 지형 측정을 위한 새로운 방법의 신뢰도 분석 및 평가)

  • Yoon, Jeong Ho;Avudainayagam, Kodikullam;Avudainayagam, Chitralekha;Swarbrick, Helen A.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.223-232
    • /
    • 2012
  • Purpose: Validating a new research method to determine posterior corneal curvature and asphericity(Q) in vivo, based on measurements of anterior corneal topography and corneal thickness. Methods: Anterior corneal topographic data, derived from the Medmont E300 corneal topographer, and total corneal thickness data measured along the horizontal corneal meridian using the Holden-Payor optical pachometer, were used to calculate the anterior and posterior corneal apical radii of curvature and Q. To calculate accurate total corneal thickness the local radius of anterior corneal curvature, and an exact solution for the relationship between real and apparent thickness were taken into consideration. This method differs from previous approach. An elliptical curve for anterior and posterior cornea were calculated by using best fit algorism of the anterior corneal topographic data and derived coordinates of the posterior cornea respectively. For validation of the calculations of the posterior corneal topography, ten polymethyl methacrylate (PMMA) lenses and right eyes of five adult subjects were examined. Results: The mean absolute accuracy (${\pm}$standard deviation(SD)) of calculated posterior apical radius and Q of ten PMMA lenses was $0.053{\pm}0.044mm$ (95% confidence interval (CI) -0.033 to 0.139), and $0.10{\pm}0.10$ (95% CI -0.10 to 0.31) respectively. The mean absolute repeatability coefficient (${\pm}SD$) of the calculated posterior apical radius and Q of five human eyes was $0.07{\pm}0.06mm$ (95% CI -0.05 to 0.19) and $0.09{\pm}0.07$ (95% CI -0.05 to 0.23), respectively. Conclusions: The result shows that acceptable accuracy in calculations of posterior apical radius and Q was achieved. This new method shows promise for application to the living human cornea.

Imaging Feature of Radiation Induced Lung Disease (방사선 폐손상의 방사선학적 소견)

  • Lee, Jae Gyo;Rho, Byeung Hak;Chang, Jae Chun;Kim, Myung Se
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.2
    • /
    • pp.146-154
    • /
    • 2000
  • Background and Purpose: Radioopaque lesions are commonly seen in patients who received thoracic radiotherapy for various kinds of thoracic neoplasm, But therir exact diagnos are sometimes uncertain. Patients and Methods: We examined simple chest radiograph and computed tomogram(CT) of 69 patients who received thoracic radiotherapy for lung cancer and were follow up at least 6 months in Yeungnam University Medical Center. Results: Of the 69 patients. thirty-eight patients showed radioopaque lesions in their chest radiographs except radiation fibrosis; radiation pneumonitis was witnessed in 24 patients. infectious pneumonia in 8 patients, and recurrence in 6 patients. In radiation pneumonitis patients, the pneumonitis occurred usually between 50 to 130 days after receiving radiation therapy, and interval between pneumonitis and fibrosis is 21 to 104 days. Simple chest radiographs of radiation pneumonitis(24 patients) represented ground glass opacities or consolidation in 4 cases(type I, 17%), reticular of reticulonodular opacities in 10 cases(type II, 42%), irregular patchy consolidations in 2 cases( type III, 8%), and consolidation with fibrosis in 8 cases(type IV, 33%), CT represent ground glass opacities or consolidation in 5 cases(type I, 29%), irregular nodular opacities in 3 cases(type II, 19%), irregular opacity beyond radiation fields in 3 cases(type III, 18%), and consolidation with fibrosis in 6 cased(type IV, 35%). The CT of four patients who represented type II on simple chest radiographs reveal type I and III, and CT of two patients with clinical symptoms who had no abnormal finding on simple radiograph revealed type I. Conclusions: In conclusion, computed tomogram is superior to the simple radiograph when trying to understand the pathologic process of radiation pneumonitis and provide confidence in the diagnosis of radiation induced lung disease.

  • PDF