• 제목/요약/키워드: Evaporation performance

검색결과 446건 처리시간 0.027초

대향류 핀삽입형 재생증발식 냉방기의 냉방성능 (Cooling Performance of a Counterflow Regenerative Evaporative Cooler with Finned Channels)

  • 문현기;이대영
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.462-469
    • /
    • 2008
  • A regenerative evaporative cooler has been fabricated and tested for the evaluation of cooling performance. The regenerative evaporative cooler is a kind of indirect evaporative cooler comprised of multiple pairs of dry and wet channels. The air flowing through the dry channels is cooled without any change in the humidity and at the outlet of the dry channel a part of air is redirected to the wet channel where the evaporative cooling takes place. The regenerative evaporative cooler fabricated in this study consists of the multiple pairs of finned channels in counterflow arrangement. The fins and heat transfer plates were made of aluminum and brazed for good thermal connection. Thin porous layer coating was applied to the internal surface of the wet channel to improve surface wettability. The regenerative evaporative cooler was placed in a climate chamber and tested at various operation condition. The cooling performance is found greatly influenced by the evaporation water flow rate. To improve the cooling performance, the evaporation water flow rate needs to be minimized as far as the even distribution of the evaporation water is secured. At the inlet condition of $32^{\circ}C$ and 50%RH, the outlet temperature was measured at $22^{\circ}C$ which is well below the inlet wet-bulb temperature of $23.7^{\circ}C$.

Ga 조성이 동시진공 증발법으로 제조된 CIGS 태양전지 특성에 미치는 영향 (Effects of Ga contents on the performance of CIGS thin film solar cells fabricated by co-evaporation technique)

  • 정성훈;윤재호;안세진;윤경훈;김동환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.438-440
    • /
    • 2008
  • Effects of Ga contents of CIGS absorber layer on the performance of thin films solar cells were investigated. As Ga content increased, the grain size of CIGS films decreased presumably because Ga diffusion during 2nd stage of co-evaporation process is more difficult than In diffusion. Performances of corresponding solar cell show systematic dependence on Ga content in which open circuit voltage increases and short circuit current and fill factor decrease as Ga contents increases. At a optimal condition of Ga/(In+Ga)=0.27, the solar cell shows a conversion efficiency of 15.6% with $V_{OC}$ of 0.625 V, $J_{SC}$ of 35.03 mA/$cm^2$ and FF of 71.3%.

  • PDF

인공신경망과 유전자 알고리즘을 이용한 증발접시 증발량과 증발산량의 모형화 (Pan Evaporation and Reference Evapotranspiration Modeling using Neural Networks and Genetic Algorithm)

  • 김성원;김형수;지홍기
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.115-119
    • /
    • 2006
  • The goal of this research is to develop and apply the generalized regression neural networks model (GRNNM) embedding genetic algorithm (GA) for pan evaporation, which is missed or ungaged and for the alfalfa reference evapotranspiration, which is not measured in South Korea. The GRNNM-GA is evaluated using the training, the testing, and reproduction performance respectively for the estimation of the PE and the alfalfa reference evapotranspiration. Since the observed data of the alfalfa reference evapotranspiration using lysimeter have not been measured for a long time in South Korea, the PM method is used to assume and estimate the observed alfalfa reference evapotranspiration. From this research, we evaluate the impact of the limited climatical variables on the accuracy of the GRNNM-GA. We should, furthermore, construct the credible data of the PE and the alfalfa reference evapotranspiration and suggest the reference data for irrigation and drainage networks system in South Korea.

  • PDF

액체수소 저장용기의 열해석 (Thermal Analysis of a Liquid Hydrogen Vessel)

  • 김서영;강병하
    • 한국수소및신에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.57-65
    • /
    • 1997
  • Thermal analysis has been performed to design a high-performance $LH_2$ vessel with about 1% per day evaporation loss. Analysis includes the combined insulations of MLI(Multi-Layer Insulation) and VCS (Vapor-Cooled Shield) under high vacuum. Combined insulation of MLI and VCS shows the existence of optimal location of VCS to minimize evaporation loss. Comparison of parallel-type DVCS (Double Vapor-Cooled Shield) and serial-type DVCS is also made to show the effectiveness of the system. The results indicate that the serial-type DVCS vessel is better than the parallel-type DVCS vessel with respect to overall evaporation loss. The combined insulation of SVCS (Single Vapor-Cooled Shield) with a partial MLI can give a similar performance characteristics compared to that with MLI and DVCS.

  • PDF

Progress in research and development for REBCO coated conductors by reactive co-evaporation

  • Oh, S.S.;Kim, H.S.;Ha, H.S.;Ko, R.K.;Ha, D.W.;Lee, H.;Moon, S.H.;Yoo, S.I.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.1-5
    • /
    • 2013
  • This paper reviews recent progress in research and development (R&D) of reactive co-evaporation for high performance REBCO coated conductors in Korea. Two types of reactive co-evaporation methods were developed for the deposition of SmBCO and GdBCO superconducting layers respectively on the IBAD (Ion Beam Assisted Deposition)-MgO template in the Korean coated conductor project. Batch type reactive co-evaporation equipment and its processing were developed for SmBCO coated conductors at Korea Electrotechnology Research Institute (KERI) in conjunction with the Korea Advanced Institute of Science and Technology (KAIST), and a very high critical current exceeding 1,000 A/cm at 77 K in the self field was achieved through the optimization of deposition parameters. Reel-to-reel type reactive co-evaporation processing with a high conversion rate was also developed, while long length GdBCO coated conductors have been routinely produced by SuNAM Co. The minimum critical current of 422 A/cm-w at 77 K in self field was confirmed for 1 km-long GdBCO tape.

하절기 기화냉각장치 설치에 따른 가스터빈 성능변화 (Performance Change of Gas Turbine with a Evaporation Cooling System in Summer Season)

  • 정현조;유호선;문승재
    • 플랜트 저널
    • /
    • 제13권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 본 연구는 하절기 가스터빈 압축기 입구에 설치된 기화냉각장치로 인하여 저하된 공기온도가 가스터빈 성능에 어떠한 변화를 미치는지에 대하여 해석하였다. 연구 대상은 인천화력본부 가스터빈 3호기이며, 기종은 Siemens SGT6-4000F(V 84.3A)이다. 기화냉각장치 설치 전후를 비교하기 위하여 특설계측기를 설치하였으며, 2015년 8월 3일에서 14일까지 11시부터 15시 사이에 대기온도 $29{\pm}1^{\circ}C$ 조건에서 설치 전후 각각 5회씩 총 10회에 걸쳐 정밀성능시험을 시행하고 각각의 평균값을 적용하였다. 시험 결과, 가스터빈 압축기 입구 공기온도 $4.12^{\circ}C$ 저하로 공기 밀도가 증가되어 압축기 압력비는 0.27 증가, 압축기 효율은 0.29 %p 상승, 가스터빈 엔탈피강하 효율은 0.31 %p 증가하였고, 가스터빈 효율은 0.44%p, 출력은 4,489 kW가 증대되는 효과를 얻을 수 있었으며, 습도 및 유동저항 증가에 따른 영향은 미미하였다.

  • PDF

LiBr 수용액의 수평관 유하액막 증발에 있어서의 열전달계수 특성 (The characteristics of heat transfer coefficient for falling-film evaporation on a horizontal tube with aqueous LiBr solution)

  • 지용해;김동관김무환
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.294-302
    • /
    • 1997
  • Falling-film evaporation experiments for aqueous solution of lithium bromide (LiBr) were performed on a horizontal smooth 19.05-mm-dia copper tube. Average heat transfer coefficients were obtained with varied film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. Heat transfer coefficients increase with increasing system pressure and decreasing concentration. For degrees of wall superheat, the heat transfer coefficient did not't show the distinct trend. For this experimental ranges, heat transfer coefficients showed maximum values at an optimal film Reynolds number. The results of this work were compared with pool boiling data reported previously, and it was shown that the heat transfer performance is superior to the pool boiling.

낮은핀관의 액막 증발 촉진에 관한 연구 (Enhancement of thin film evaporation on low-fin tubes)

  • 김내현
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.674-682
    • /
    • 1998
  • In this study, thin film evaporation of water on low-fin tubes were experimentally investigated. Five low-fin tubes with different fin spacing and fin height were tested. Test range covered 0.146kg/ms $\leq$$\Gamma$$\leq$0.219kg/ms and 10㎾/$\m^2$$\leq$q $\leq$70㎾/$\m^2$. Saturation temperature was loot. Compared with the plain tube, low fin tubes enhanced the water film evaporation from 60% to 100%. Tubes with fin spacing smaller than 2mm and fin height higher than 1mm performed better than tubes with other fin configuration. However, when fin spacing was too small at high film flow or fin height was too high at low film flow, the performance decreased. The heat transfer coefficient slightly increased as the flow rate increased. Correlations are developed based on present data.

  • PDF

냉동기 펌프다운 운전성능에 관한 연구 (A Study on Pump Down Operation Performance of Refrigerator)

  • 김철수;정한식;정효민
    • 설비공학논문집
    • /
    • 제18권12호
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

대형 저압 증발식 조수기 개발 (A Development Study on the Evaporation Type Large Fresh Water Generator)

  • 김병덕;송치성;김경근;김종헌;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권4호
    • /
    • pp.1-12
    • /
    • 1994
  • Most merchant ships are supplied with the only essential fresh water from a port for economical cargo transportation and the reduction of a nevigation expense. And the deficient fresh water for a voyage is produced by fresh water generator with the various exhaust energy generated in the engine room on a voyage. At present, an evaporation type fresh water generator are extensively used on ship because the operating cost of it is lower than that of a reverse osmosis pressure type. This study introduce a development results on the large evaporation type fresh water generator enable to be used for large merchant ships. It is accomplished the performance test using the developed large fresh water generator.

  • PDF