Purpose: This study conducts quantitative evaluation or structural and functional characteristics or normal skeletal muscle with ultrasound image and surface electromyography, and is to provide basic materials for utilizing ultrasound image analysis in physical therapy diagnosis and assessment of skeletal muscle. Methods: Measurement of three stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age and gender were compared and correlations among measured items were analyzed and then the following conclusions were obtained. Results: Analysis of ultrasound image of normal skeletal muscle showed that density, median frequency had the closest relations with age. In addition, it was found that there were high correlations between density explaining structural characteristics of skeletal muscle and median frequency explaining functional characteristics. Conclusion: Analysis of ultrasound image makes complex evaluation of structure and function of skeletal muscle possible when it is connected with functional evaluation method using physical measurement surface electromyography as well as quantitative evaluation of structural changes of skeletal muscle and is effective in complementing physical therapy diagnosis centering around functionality evaluation.
This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.
When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.
Since ultrasound has different reflections depending on components of organization, analysis of ultrasound images of skeletal muscle can offer both quantitative and qualitative reports as concerns skeletal muscle structure. This study is focused on the ultrasound method for evaluating the structural characteristics of skeletal muscle and also conducted to examine its practicality. After obtaining images of the elbow flexors from an ultrasound image device with 88 normal subjects whose ages were between twenty and seventy years old (44 men and 44 women), muscular density and white area index (WAI) which indicated structural characteristics of skeletal muscle were analyzed with gray scale analysis. The study examined correlations between subject's age and items which obtained from measuring ultrasound images and the differences in relations to sex and age. Muscular density and WAI had a high correlation with age and were significantly increased in men and women with greater age. The quantitative evaluation method of skeletal muscle structure which analyzed the ultrasound images has high practicality because it is a non-invasive method which complements physical therapy diagnosis and research methods and promotes functionality evaluation.
Transabdominal ultrasound (TAUS) is useful in all aspects of lesion screening, monitoring activity, or treating/diagnosing any related complications of inflammatory bowel disease. Its ability to screen or diagnose complications is almost the same as that of other methods, such as CT or MRI. Moreover, its noninvasiveness makes it a first-line examination method. A TAUS image depicting ulcerative colitis will show large intestinal wall thickening that is continuous from the rectum, which is mainly due to mucosal layer thickening, while for Crohn's disease, a TAUS image is characterized by a diversity in the areas affected, distribution, and layer structure. Indicators of activity monitoring include wall thickness, wall structure, and vascular tests that use Doppler ultrasound or contrast agents. While all of these have been reported to be useful, at this time, no single parameter has been established as superior to others; therefore, a comprehensive evaluation of these parameters is justified. In addition, evaluating the elasticity of lesions using elastography is particularly useful for distinguishing between fibrous and inflammatory stenoses. However, the lack of objectivity is the biggest drawback of using ultrasound. Standardizing and popularizing the ultrasound process will be necessary, including scanning methods, equipment settings, and image analysis.
For the proper conservation of wooden cultural properties, non-destructive evaluation (NDE) method, which can be used to quantitatively evaluate the internal state of wood members, are needed. In this study, an ultrasonic CT system composed of portable devices was attempted, and the capacity of this system was verified by reconstructing the CT images for two phantoms and two artificially defected specimens. Results from this study showed that the sizes of detected defects were enlarged and the shapes were distorted on the CT images. Also, the positions were shifted somewhat toward the surface of specimen, which is regarded due to the anisotropic property of wood. Compared to the filtered back-projection method, SIRT (simultaneous iterative reconstruction technique) method was determined to be more efficient as the algorithm of image reconstruction for wood. A new ultrasonic CT system is thought to be used as a NDE method for wood. However wood characteristics and wave diffraction within wood made it difficult to accurately evaluate the size, shape and position of defects. To improve the quality of CT image of wood, more research including the relationship between wood and ultrasound is needed, and wood properties should be taken into consideration on the image reconstruction algorithm.
This study aimed to compare filters for reducing speckle noise in ultrasound images using clinical liver images. We acquired the clinical liver ultrasound images, and noisy images were obtained by adding 0.01, 0.05, 0.10, and 0.50 intensity levels of speckle noise to the liver images. The Wiener filter, median modified Wiener filter, gamma filter, and Lee filter were designed for the noisy images by setting window sizes at 3×3, 5×5, and 7×7. The coefficient of variation (COV) and contrast to noise ratio (CNR) were calculated to evaluate noise reduction and various filters. Moreover, the filter with the highest image quality was selected and quantitatively compared to a noisy image. As a result, COV and CNR showed the noise improved result when the Lee filter was applied. Furthermore, the Lee filter image with a window size of 7×7 was noted to possess approximately a minimum of 1.28 to a maximum of 3.38 times better COV and a minimum of 2.18 to a maximum of 5.50 times better CNR than the noisy image. In conclusion, we confirmed that the Lee filter was effective in reducing speckle noise and proved that an appropriate window size needs to be set considering blurring.
Prior studies on frequency-related image quality analysis of intravascular ultrasound catheters are lacking both in Korea and abroad. Therefore, this study was conducted to prepare a standard for measuring the image quality using the program and to suggest a measuring method to researchers related to the quality analysis of intravascular ultrasound images. For the target, the vessel lumen size is 3.0 - 4.0 mm. Before using intravascular ultrasound, thoroughly clean the ultrasound catheter so that no air or foreign substances enter it. Normal vascular images and lesion vascular images of sufficiently dilated images were used. As a standard image acquisition method, the image of the end-systolic section, which has the best evaluation of vascular lesions when using intravascular ultrasound, was acquired retrospectively through the DCAS PACS program to set the standard. When setting the measurement method criteria, we proposed a standard setting method that corresponds to the concentric and eccentric circles of normal and lesion vessels. By applying this criterion, we proposed a method for measuring the lumen and lateral cavities of normal and lesion vessels of interest and background area. In conclusion, if the image quality of intravascular ultrasonography is measured through the method devised by these researchers, consistent quality measurement is possible regardless of the type of intravascular ultrasound catheter. Therefore, it is thought that it can be applied as a guideline for the actual image quality measurement method in the study related to intravascular ultrasound image quality.
The Transactions of The Korean Institute of Electrical Engineers
/
v.59
no.12
/
pp.2349-2351
/
2010
Photo Acoustic Tomography (PAT) is a hybrid imaging modality which combines high contrast of optical imaging and spatial resolution of ultrasound imaging, thus it is suitable to image biological tissue noninvasively. Laser-induced photoacoustic signals were measured from a sample by means of an unfocused ultrasound transducer, then PAT image was reconstructed based on a universal back-projection algorithm. To evaluate the feasibility of our system, phantom test was performed, consequently, the PAT images obtained using our system showed highly analogous shape and volume with those of the phantom. This result demonstrated that our system can provide a powerful tool for imaging the substructure of biological tissue in non-invasive manner.
The ultrasound imaging in medical diagnosis has become a popular modality because of its safe, noninvasive, portable, relatively inexpensive, and provides a real-time image formation. However, usefulness of ultrasound imaging is at times limited due to the presence of signal-dependent noise like as speckle. Therefore, noise reduction is very important, as various types of noise generated limits the effectiveness of medical image diagnosis. This paper introduces a speckle noise reduce algorithm using total variation denoising (TVD) in Laplacian pyramid. With this method, speckle is removed by TVD of bandpass ultrasound images in Laplacian pyramid domain. For TVD in each pyramid layer, a ${\lambda}$ is selected by trial-and-error method. The visual comparison of despeckled 'in vivo' ultrasound images from pancreas shows that the proposed method could effectively preserve edges and detailed structures while thoroughly suppressing speckle. For a Simulated B-mode image, contrast-to-noise-ratio (CNR) and signal-to-noise-ratio (SNR) were obtained like 4.65 dB and 14.11 dB, respectively. The results show that the proposed method can conduct better than some of the existing methods in terms of the CNR and the SNR.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.