• Title/Summary/Keyword: Evaluation of Value at Risk

Search Result 127, Processing Time 0.031 seconds

Study on Relationship Between Intima Medial Thickness and the Plaque in Stroke Patients on Carotid Artery Sonography (뇌경색 환자에서 초음파로 측정한 경동맥 내막-중막두께와 죽상경화반의 관련성에 대한 연구)

  • Lee, Mi-Hwa;Kwon, Duk-Mun;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • The carotid intima-media thickness (IMT) is an early structural marker of the atherosclerotic process and is the only non-invasive test that is currently recommended by the American Heart Association for evaluation of the risk. However, use of this parameter has a limitation because it assumes uniform thickness throughout the blood vessel, whereas atherosclerosis is a focal phenomenon that is confined to intima. In fact, plaque can be found along the atherosclerotic blood vessels even though its value is unknown. The aim of this study is to analyze the carotid plaque and IMT in the stroke patients. We investigated the patients with ischemic stroke, who were admitted to the department of neurology at the Stroke Special Hospital from January to March 2008. After the carotid IMT and plaque were assessed by B-mode ultrasonography, IMT and carotid plaque to risk variables (age, sex) were analyzed. The distribution of CCA IMT was significantly different in terms of age (p = 0.004). Likewise, the distribution of carotid plaque was also significantly different in terms of age (p = 0.006). Carotid plaque was 69 and 92% in normal and abnormal CCA IMTs respectively. The results showed that the CCA IMT was closely associated with carotid plaque.

  • PDF

A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Characteristics and Recurrence Risk Factors of Urinary Tract Infection in Early Infancy (6개월 미만 영아 요로 감염의 특성과 재발의 위험 인자)

  • Kang Hee-Gyung;Kim Nam-Hee;Kang Ju-Hyung;Ha Il-Soo;Cheong Hae-Il;Choi Yong
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.223-228
    • /
    • 2004
  • Purpose and Methods: Urinary tract infection(UTI) is one of the most important diseases of childhood, especially for young infants. To characterize the patients diagnosed with febrile UTI in their first 6 months of life and to explore the risk factors of recurrent UTI, a retrospective study was performed. Results: Among the 90 patients studied, 77 were boys(86%). First episodes of UTI were diagnosed at the age of $2.5{\pm}1.4$ months. These patients underwent ultrasonographic evaluation of urinary tract(n=90) and voiding cystourethrography(n=81) where 53 and 35 studies showed abnormal findings respectively, and a total of 45 cases of urinary tract anomaly including vesicoureteral reflux(VUR, n=35) were diagnosed. Normal findings on ultrasonography indicated decreased risk of VUR in boys of 1-3 months of age(n=30). 53 patients were followed up more than 6 months and 45 episodes of subsequent UTI developed in 29 patients during the first 6-month period. Patients with relapse were older than patients without relapse at the diagnosis of first UTI, but other clinical parameters including abnormal findings on the imaging studies and prophylactic antibiotics prescription were not different between the two groups. Conclusion: UTI in early infancy occurred mainly in male infants and half of the patients had structural anomalies. USG was of clinical value in detecting anomalies requiring surgical intervention, and to rule out high grade VUR in 1-3 months old boys. Results of the imaging study or prophylactic antibiotics could not modify the risk of recurrent UTI. (J Korean Soc Pediatr Nephrol 2004;8:223-228)

  • PDF

Assessment of Compensator Thickness in Proton Therapy (양성자 치료 시 사용되는 Compensator의 Thickness에 대한 적정성 평가)

  • Park, Yong Soo;Jang, Jun Yeong;Cho, Gwang Hyeon;Park, Yong Cheol;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.35-40
    • /
    • 2018
  • Purpose : The range of force differs from the size of proton energy used in our hospital. The compensator enables to change energy size based on distal thickness which also makes changes in dose rate. Therefore, the purpose of this study is to evaluate the effect of changing the thickness of compensator distal on dose range and beam on time. Subject and Methodology : Five low energy patients who have received proton therapy were selected as subjects for this study. Beam on was checked for the selected patients during the existing therapy. After then, the thickness of distal of compensator was increased by 2 cm up to 14 cm through proton therapy plan system(TPS) for comparative analysis. For the evaluation of dose range, the value of the target's conformity index(CI) and the maximum dose of rear side target's organ at risk(OAR) were compared. Furthermore, to evaluate the effect of therapy time, beam on time was compared by making compensator distal in each thickness. Result : The result of homogeneity index and conformity index of the increased compensator distal showed the same level in all patients. The comparison results of OAR of target rear side showed 7 cGy at spine cord of abdomen at maximum, 88 cGy at eyeball's RT lens, 391 cGy at RT lens of nasal cavity 51 cGy at trachea of the mediastinum, and 661 cGy at a small bowl of the pelvis. The comparison results of the beam on time showed a reduction from 126 seconds to 62 seconds for the abdomen, from 105 seconds to 37 seconds for the eyeball, from 187 seconds to 134 seconds for nasal cavity, from 100 seconds to 40 seconds for mediastinum, from 440 seconds to 118 seconds for the pelvis. Conclusion : The research result showed that as the distal thickness of compensator increased, the size of energy increased. In addition, beam on decreased due to the increase of dose rate. It is expected that the result would help reduce the treatment time and increase the convenience of patients if it is applied to liver patients who need respiratorygated therapy and pediatric patients. However, distal penumbra increased as the size energy increased. Therefore, in treating cases where OAR is in the vicinity of the target rear side, the influence of penumbra should be taken into account in adjusting thickness level of the compensator in proton therapy plan.

  • PDF

The metabolic syndrome and body composition in childhood cancer survivors

  • Sohn, Young-Bae;Kim, Su-Jin;Park, Sung-Won;Kim, Se-Hwa;Cho, Sung-Yoon;Lee, Soo-Hyun;Yoo, Keon-Hee;Sung, Ki-Woong;Chung, Jae-Hoon;Koo, Hong-Hoe;Jin, Dong-Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.6
    • /
    • pp.253-259
    • /
    • 2011
  • Purpose: Long-term survivors of childhood cancer appear to have an increased risk for the metabolic syndrome, subsequent type 2 diabetes and cardiovascular disease in adulthood compared to healthy children. The purpose of this study was to investigate the frequency of the metabolic syndrome and associated factors in childhood cancer survivors at a single center in Korea. Methods: We performed a retrospective review of medical records of 98 childhood cancer survivors who were diagnosed and completed anticancer treatment at Samsung Medical Center, Seoul, Korea between Jan. 1996 and Dec. 2007. Parameters of metabolic syndrome were evaluated between Jan. 2008 and Dec. 2009. Clinical and biochemical findings including body fat percentage were analyzed. Results: A total of 19 (19.4%) patients had the metabolic syndrome. The median body fat percentage was 31.5%. The body mass index and waist circumference were positively correlated with the cranial irradiation dose (r=0.38, P<0.001 and r=0.44, P<0.00, respectively). Sixty-one (62.2%) patients had at least one abnormal lipid value. The triglyceride showed significant positive correlation with the body fat percentage (r=0.26, P=0.03). The high density lipoprotein cholesterol showed significant negative correlation with the percent body fat (r=- 0.26, P=0.03). Conclusion: Childhood cancer survivors should have thorough metabolic evaluation including measurement of body fat percentage even if they are not obese. A better understanding of the determinants of the metabolic syndrome during adolescence might provide preventive interventions for improving health outcomes in adulthood.

The Effects of Bundle Price Discount Framing and Message Framing on Consumers' Evaluation of Bundle Component (번들가격할인 프레이밍과 메시지 프레이밍이 소비자의 번들구성제품에 대한 평가에 미치는 영향)

  • Park, Sojin
    • Asia Marketing Journal
    • /
    • v.13 no.3
    • /
    • pp.55-77
    • /
    • 2011
  • This study investigate the interaction effects of bundle price discount framing and message framing on consumer's attitude of bundle component. Although each effect of bundle price discount framing and message framing has been explored individually, few attempts have been made to invest them jointly. This study tests the interaction effects of bundle price discount framing and message framing on consumer's evaluation of bundle component. Moreover, this research focuses on consumer's evaluation of individual bundle component while the existing research on bundling primarily focused on consumer's evaluation of the bundle. Prior research suggests that consumers are sensitive to the framing of prices and discounts in the presentation of the bundle offer. For example, there is considerable evidence that partitioning or consolidating the prices of a bundle can influence the attractiveness of the bundle offer. Similarly, there is evidence that an equivalent price reduction to the overall bundle, one of the individual products in the bundle, or distributed among the individual products in the bundle can alter the perceived attractiveness of the offer (e.g. Chakravarti, Krish, Paul, and Srivastava 2002; Hamilton and Srivastava 2008; Janiszewski and Cunha 2004; Johnson, Herrmann and Bauer 1999; ; Morwitz, Greenleaf, and Johnson 1998; Yadav 1994; 1995). In line with these earlier research, this research suggests that the bundle type can influence the consumer's evaluation of bundle component. There are two types of bundle - mixed-leader bundle and mixed-joint bundle. In mixed-leader bundling, the price of one of the two products is discounted when the other product is purchased at the regular price. In mixed-joint bundling, a single price is set when the two product are purchased jointly. This study supposes that the teeth whitening product is the leader product in a mixed-leader bundle. So bundle price discount framing is manipulated such as "Buy the teeth whitening product (regular price \80,000) and get 50% discount on the functional toothpaste(regular price \40,000), special set price \100,000" or "Buy the functional toothpaste and the teeth whitening product as a set and get discount for the set, special set price \60,000". Message framing is manipulated through the product claims described in an advertising bill. The positive framing presents that "Over 95% of users achieved the expected 2-3 shades of improvement in two weeks" where as the negative framing presents "less than 5% of users did not achieve the expected 2-3 shades of improvement in two weeks". This study uses hypothetical brand name of the teeth whitening product and the functional toothpaste This study is based on a 2x2 factorial design with bundle discount framing (mixed-leader bundle vs. mixed-joint bundle) and massage framing (positive vs. negative). The dependant variables are consumer's perceived quality and attitude of the teeth whitening product The data reveals that two dependant variables are correlated, so the data is analyzed with two-way MANOVA. This research explores the significant interaction effect of bundle discount framing and message framing on consumer's perceived quality and attitude of the teeth whitening product. When the message framing is positive, consumer's perceived quality and attitude of the teeth whitening product is higher in mixed-leader bundle than mixed-joint bundle condition. However, when the message framing is negative, consumer's evaluation is higher in mixed-joint bundle than mixed-leader bundle. The author explains this result by stating that consumers are less likely to use heuristics such as price-quality association and value discounting hypothesis(Raghubir 2004) in the negative message framing condition. Additionally, consumer's perceived risk of the teeth whitening product in the negative message framing condition can be more reduced by the bundle partner(e.g. the toothpaste) in mixed-joint bundle than mixed-leader bundle. Based on the results, marketing managers are advised to use different bundle type based on message framing of their product.

  • PDF

Evaluation of Microbiological Hazards of Cooking Utensils and Environment of Mass Catering Establishments (급식장의 조리기구.용기 및 작업환경에 대한 미생물학적 위해분석)

  • 박희경;김경립;신혜원;계승희;유화춘
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.4
    • /
    • pp.315-323
    • /
    • 2000
  • Serious consequences can arise from lack of hygiene in mass catering. Microbiological testing is of value in determining hazards for developing a HACCP plan, and in demonstrating to food handlers the reality of the microbial risk. This studies was performed to describe the overall hygiene of cooking utensils and equipments, employees, and environment in mass catering establishments. Generally, hygienic conditions of cutting board and sanitized dish cloth were better than those of other cooking utensils such as knife, sieve, and peeler. It was found that the cross-contamination of knife might be caused by the use of contaminated sanitizing solution. It was observed that there was considerable variation (10$^1$~10$^{5}$ CFU) of the number of general bacteria for employee's hands. The number of general bacteria were influenced from establishment, employee, and the period of analysis. The number of Coliform group for employee's hands was in the range of 10$^2$~10$^4$CFU only at the first analysis. Total aerial bacteria in working area of mass catering establishments was below 7 CFU/Plate and aerial Staphylococcus sp. was not detected at all except one spot.

  • PDF

Evaluation of Tangential Fields Technique Using TOMO Direct Radiation Therapy after Breast Partial Mastectomy (유방 부분 절제술 후 방사선 치료 시 TOMO Direct를 이용한 접선 조사의 선량적 유용성에 관한 고찰)

  • Kim, Mi-Jung;Kim, Joo-Ho;Kim, Hun-Kyum;Cho, Kang-Chul;Chun, Byeong-Chul;Cho, Jeong-Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • Purpose: Investigation of the clinical use of tangential fields technique using TOMO direct in comparison to conventional LINAC based radiation therapy after breast partial mastectomy. Materials and Methods: Treatment plans were created for 3 left-sided breast cancer patients who had radiation therapy after breast partial mastectomy by using wedged tangential fields technique, field in field technique (FIF), TOMO Direct, TOMO Direct intensity modulated radiation therapy (IMRT) under the normalized prescription condition ($D_{90%}$: 50.4 Gy/28 fx within CTV). Dose volume histogram (DVH) and isodose curve were used to evaluate the dose to the clinical target volume (CTV), organ at risk (OAR). We compared and analyzed dosimetric parameters of CTV and OAR. Dosimetric parameters of CTV are $D_{99}$, $D_{95}$, Dose homogeneity index (DHI: $D_{10}/D_{90}$) and $V_{105}$, $V_{110}$. And dosimetric parameters of OAR are $V_{10}$, $V_{20}$, $V_{30}$, $V_{40}$ of the heart and $V_{10}$, $V_{20}$, $V_{30}$ of left lung. Results: Dosimetric results of CTV, the average value of $D_{99}$, $D_{95}$ were $47.7{\pm}1.1Gy$, $49.4{\pm}0.1Gy$ from wedged tangential fields technique (W) and FIF (F) were $47.1{\pm}0.6Gy$, $49.2{\pm}0.4Gy$. And it was $49.2{\pm}0.4$ vs. $48.6{\pm}0.8Gy$, $49.9{\pm}0.4$ vs. $49.5{\pm}0.3Gy$ Gy for the TOMO Direct (D) and TOMO Direct IMRT (I). The average value of dose homogeneity index was W: $1.1{\pm}0.02$, F: $1.07{\pm}0.02$, D: $1.03{\pm}0.001$, I: $1.05{\pm}0.02$. When we compared the average value of $V_{105}$, $V_{110}$ using each technique, it was the highest as $34.6{\pm}9.3%$, $7.5{\pm}7.9%$ for wedged tangential fields technique and the value dropped for FIF as $16.5{\pm}14.8%$, $2.1{\pm}3.5%$, TOMO direct IMRT as $7.5{\pm}8.3%$, $0.1{\pm}0.1%$ and the TOMO direct showed the lowest values for both as 0%. Dosimetric results of OAR was no significant difference among each technique. Conclusion: TOMO direct provides improved target dose homogeneity over wedged tangential field technique. It is no increase the amount of normal tissue volumes receiving low doses, as oppose to IMRT or Helical TOMO IMRT. Also, it simply performs treatment plan procedure than FIF. TOMO Direct is a clinical useful technique for breast cancer patients after partial mastectomy.

  • PDF

EVALUATION OF GINGIVAL CONDITION ON CHILDREN USING PERIOTRON (Periotron을 이용한 소아 치은 상태의 평가)

  • Shin, Jeong-Geun;Kim, Jae-Gon;Yang, Yeon-Mi;Kim, Sung-Hee;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.411-421
    • /
    • 2006
  • In children, during developing occlusion stage, many studies confirm a high prevalence of gingival inflammation. Prevention, early diagnosis and treatment of gingival and periodontal disease is important because by establishing excellent oral hygiene habits in children, the risk of periodontal disease can be on the decrease in adulthood. This study evaluated the gingival conditions of 50 children$(8.5{\pm}3.1years)$ and 20 $adults(26.1{\pm}3.3 years)$ receiving clinical examination and GCF test at the pediatric dentistry of Chonbuk national university hospital in Jeonju, Korea. I estimated children's and adult's gingival states by measuring gingival crevicular fluid(GCF) using Periopaper and $Periotron^{(R)}$ 8000, gingival index, plaque index, DMFT scale. The results were as follows : 1. There are no statistical differences of GCF volume among the groups of the primary dentition, tooth erupting stage, complete eruption stage(p>0.1). But mean value of GCF is highest at the tooth erupting stage. 2. Comparing with adults, children have higher mean value of GCF volume with statistical differences (p<0.001). 3. There is statistically positive relationship between volume of GCF and gingival index (GI), plaque index(PLI) in both adults and children(GI; r=0.394, PLI ; r= 0.642). 4. There is no relationship between GCF volume and dental caries, composite resin treatments (p>0.05). But There is statistically positive relationship between GCF and orthodontic treatments(p<0.001) 5. Primary dentition has higher mean value of DMFT than permanent dentition(p<0.001). But there is no statistical relationship between GCF and DMFT (p>0.1).

  • PDF

Evaluation of Usefulness on In-vivo Diode Dosimetry for Measuring the Tumor Dose of Oral Cancer Patient (구강암 환자의 종양 선량 측정을 위한 In-vivo Diode Dosimetry의 유용성 평가)

  • Na Kyung-Su;Lee Je-Hee;Park Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2005
  • Purpose : This test is designed to identify the validity of treatment plan by implementing real-time dosimetry by means of dose that is absorbed into PTV and OAR when preparing doses of 3D and POP plans. Materials and Methods : In treatment. error can be calculated be comparing Exp. Dose with the actual dose, which has been converted from 'the reading value obtained by placing diode detector on the area to be measured'. Same test can be repeated using Alderson-Rando phantom. Results : Errors were found: A patient(POP plan): 197.6/199=-1.2%, B patient(3D-plan): 199.9/198.7=+0.6%, C patient: 196/200=-1.5%. In addition, considering the resulted value of measuring OAR besides target-dose for C patient showed 96/200, representing does of 47%, the purpose of protection was judged to be duly accomplished. Also it was acknowledged the resulted value of -3.7% met the targeted dose within the range of ${\pm}5%$. Conclusion : Aimed for identifying the usefulness of pre-treatment dose measurement using diode detector, this test was useful to evaluate the validity of curing because it resulted in the identification of category to be protected as well as t dose. Moreover, it is thought to have great advantage in ascertaining the dose of target, dose of which is not calculated yet. Similar to L-gram before treatment, this test is thought to be very effective so that it can bring great advantages in the aspects such as validity of curing method and post-treatment plan as well.

  • PDF