• Title/Summary/Keyword: Evaluation Standards

Search Result 2,552, Processing Time 0.031 seconds

Pollutants Classification based on Trend Analysis and Assessment of Water Pollutants Achievement in Subbasins of Han River Basin (한강수계 중권역별 오염물질 추세분석 및 달성도 평가를 통한 우선관리물질 선정)

  • Kim, Kyeung;Song, Jung-Hun;Lee, Do Gil;Hwang, Ha-sun;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.3
    • /
    • pp.67-76
    • /
    • 2019
  • The objectives of this study were to analyze trends of water pollutants and to evaluate the achievement of water quality standards by subbasins in the Han River. The trends of 40 water pollutants at 232 water quality measurement points were analyzed. Chemical oxygen demand (COD), Total organic carbon (TOC), Total coliforms (TC), et cetera were found to be worsening trend. For evaluation of achievement, we evaluated water quality arithmetic mean with river environment standards and human health standards at representative points of the subbasin. Biochemical oxygen demand (BOD), TOC, Total phosphorus (T-P), Fecal coliforms (FC), TC exceeded water quality standards, and water quality of human health standards was all satisfied. So, we prioritized pollutants. If pollutants exceed water quality standards or were worse, they were classified first pollutants. Although BOD and T-P are first pollutants because of water quality standards excess, they are continuously improved. Also, it is better to maintain current status because water quality management system of BOD and T-P is well prepared. Meanwhile, TOC, TC, and FC exceed water quality standards. Furthermore, they were worse gradually, but there is a lack of management systems such as water quality standards of the effluence facilities. Therefore, it is necessary to supplement the system. The results of this study can be used as primary data for the establishment of water quality standards and selection of management pollutants.

Upgrading of Quality Control for Herbal Medicine Use in South Korea by Introducing an Accreditation System: a brief report

  • Soo-Hyun Sung
    • Journal of Pharmacopuncture
    • /
    • v.27 no.3
    • /
    • pp.270-276
    • /
    • 2024
  • Objectives: This study aimed to present a government-led accreditation system for upgrading the quality control of herbal medicine by introducing the process and evaluation standard of external herbal dispensaries (EHDs) of traditional Korean medicine (TKM) clinics in South Korea 2018 to refer to other countries where herbal medicine were used similarly in Korea. Development Process: We organized an EHD accreditation committee for the establishment of an accreditation system. The committee consisted of 9 experts: an official of the Ministry of Health and Welfare (MoHW), a professor expert of TKM, a good manufacturing practice expert, a hazard analysis and critical control point expert, and an accreditation system expert. After 3 meetings, a draft of the evaluation standard and evaluation system was established in 2017. Based on the draft, a pilot test was conducted to determine the applicability of the evaluation standards in 2017. Two additional meeting was held to confirm the accreditation standards and was finalized in 2018. Results: The evaluation standard for EHDs was developed. In the case of herbal medicine EHDs, the evaluation standard consisted of 9 evaluation categories, 25 evaluation parts, and 81 evaluation items were developed. The results of the evaluation of the pilot tests are as follows, and the results show that there is a deviation between the EHDs. Conclusion: As a world's first, Korea MoHW successfully launched the accreditation system for upgrading the quality control system of herbal medicine not approved by Korea's Ministry of Food and Drug Safety in 2018. Our report hope to provide a good reference to other countries where having similar herbal medicine system in South Korea hoping to make better quality control of herbal medicines.

Reliability assessment standard development of pneumatic valves (공압 전자밸브 신뢰성 평가기준 개발)

  • 강보식;성백주;김도식;조정대;김형의
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.105-111
    • /
    • 2001
  • In this study, for improvement of pneumatic valve reliability, we grasped the falling-off problem in efficiency of domestic valve and performed detailed analysis the relating International standards, and we also decided sampling method and reliability evaluation items to be evaluated valves. And, in addition, we describe the developed evaluation standard to increase the competition power and to improve the reliability of domestic pneumatic valve manufacturers through deciding of test conditions and thesis of evaluation procedures to each evaluation items.

  • PDF

A Case Study on the Evaluation of a Design Adequacy of Human Factors for a Weapon System (무기체계에서의 인간공학적 설계 적합성 평가 사례연구)

  • Lee, Yeong-Bong;Lee, Sang-Tae
    • IE interfaces
    • /
    • v.3 no.1
    • /
    • pp.13-20
    • /
    • 1990
  • The application of human-factor concept in developing a complex weapon system is important for system engineer to determine the system performance and reliability. This paper describes the evaluation procedure of human factors in the X-system wherein the evaluation result provides a better performance than the previous model in operatability and maintainability. The criteria used for the evaluation of a design adequacy of the X-system are based on the military human-factor standards.

  • PDF

A Derivation of Evaluation Item about Enterprise Security Management

  • Kim, Sun-Joo;Jo, In-June
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.5
    • /
    • pp.544-548
    • /
    • 2010
  • The Enterprise Security Management system is a centralized control system based on predefined security policies by organizations. In Korea, there is a Common Criteria security certification according to the strict standards for various features. As the needs of information security product are increasing, the ESM system should be evaluated with quality characteristics. In this paper, we propose evaluation items for functionality and performance of Enterprise Security Management system, and the best practices for evaluation.

A Trend of the National and International Standards for LCD Backlights (LCD 백라이트 국내외 표준화 동향)

  • Cho, M.R.;Shin, S.W.;Lee, S.H.;Hwang, M.K.;Lee, D.Y.;Yang, S.Y.;Ham, J.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.141-144
    • /
    • 2007
  • BLUs are major component in LCD industry which occupies 90% or more of FPD market worldwide and BLU market is expected to be expanded continuously according to the trend of miniaturization, slimness, low power consumption and low weight. The larger the BLU market scale, the more important standardization of performance evaluation techniques to clearly prescribe the product specification. Currently the government is promoting the establishment of related laws and coincidence with international standards to cope with agreements such as WTO/TBT, but the nongovernmental standardization activities are not enough to be actualized. Furthermore, BLU related components such as CCFL, EEFL, inverter and reflector are already developed for localization to substitute imports with home products but collective standardization, national standardization, and international standardization are still not done. So, performance specifications and evaluation methods for normal fluorescent lamps or industrial lamps are being adopted and used as national standards and safety certification standards instead. Making these standards enables to prepare a chance to penetrate into global market and to promote world best products. Also, by making this collective standard, it provides chances to take part in international standardization activities, to protect domestic industries and technologies, to obtain the trend of advanced technologies, and to be predominant over other countries. That is to say, CCFL standardization helps raise 21st century national strategic technology policy and go ahead of globalization of core technologies.

  • PDF

International Comparison of Performance Verbs included in Achievement Standards of Mathematics Curriculum: Focusing on South Korea, the United States, the United Kingdom, and Australia (수학과 교육과정 성취기준에 포함된 수행 동사 국제 비교: 한국, 미국, 영국, 호주의 수학과 교육과정을 중심으로)

  • Kwon, Jeom-Rae;Jung, Hye-Yun;Jung, Soo-Yong
    • Communications of Mathematical Education
    • /
    • v.37 no.2
    • /
    • pp.105-134
    • /
    • 2023
  • The purpose of this study is to explore which performance verbs are used in the achievement standards of the Korean mathematics curriculum and how to improve them. So, first, we analyzed whether there were differences in the performance verbs included in the 2015 revised mathematics curriculum achievement standards by school level. In addition, it was analyzed whether there were differences in the performance verbs included in the mathematics curriculum in Korea and foreign countries. As a result of the analysis, both the frequency and the type of performance verbs included in the achievement standards of the Korean mathematics curriculum decreased as the school level increased. Also, performative verbs such as 'understand' and 'know' were excessively used. Similar tendencies were seen in foreign mathematics curricula, but the frequency and the type of performance verbs were higher than those in Korea, and various performance verbs were used. As a result of the study, it is suggested that performance verbs included in achievement standards need to be improved to improve middle and high school mathematics classes.

Power Quality Monitoring System Using DWB on Distribution Automation System (DWB를 이용한 배전자동화 기반의 전기품질 모니터링 시스템 구축)

  • Kang, Moon-Ho;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.9
    • /
    • pp.86-93
    • /
    • 2011
  • The necessity of Power Quality(PQ) Management grow bigger because the disturbance strength in power system is increasing, on the other hand, the tolerance of electrical components is reducing with widely use of the IT and digital equipments. The domestic management standards on power quality are enacted based on the IEC standards in recent. Since the IEC standards defines the measurement and evaluation point on PQ as PCC(Point of Common Coupling) which is normally the point of penetration between customer and power company, the PQ monitoring system(PQMS) should be made to measure and manage the PQ of custom effectively. In this paper, therefore, the economical construction plan on PQMS using the wireless communication channel in distribution automation system is suggested, and the usefulness of the PQMS are shown by analyzing the PQM data with IEC standards.

A Study on An Electronically Compensated Current Sensor for Measurement of Power (전력측정을 위한 전자보상 전류센서에 관한 연구)

  • Park, Y.T.;Kwon, S.W.;Lee, J.H.;Yu, K.M.
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.1-8
    • /
    • 1995
  • An electronically compensated current sensor for measurement of power is presented in this paper. An electronic technique which is proposed to design an improved current sensor by means of a feedback winding and an electronic compensation is described. A precision power transducer with a proposed current sensor has been constructed for testing and performance evaluation.

  • PDF

Application of Risk Management Standards for Product Safety Management Program (리스크 관리규격의 제품안전경영프로그램에 대한 적용)

  • 이동하;나윤균;김명수
    • Journal of Applied Reliability
    • /
    • v.1 no.2
    • /
    • pp.109-120
    • /
    • 2001
  • This study reviewed the national standards for risk management to judge whether they are suitable for a product safety management program. Among the standards issued from Australia, New Zealand, Canada, Japan, and UK, the risk management guideline (AS/NZS 4360: 2000) issued jointly from both Australia and New Zealand have better features for product safety management program than any other risk management standards in view point of broad definition of risk concept including opportunities of loss and gain, stepwise composition of management processes applicable iteratively, and integrable form of structure addible to existing management practice. Comparing the three product safety management programs suggested by several authors yielded common features of product safety management program model: (1) organization for product safety, (2) risk identification, (3) risk evaluation, (4) risk treatment, (5) monitoring/communication, and (6) documentation. All of these activities can be performed within risk management framework proposed by AS/NZS 4360.

  • PDF