• Title/Summary/Keyword: Evaluation Procedures

Search Result 1,528, Processing Time 0.032 seconds

The Usefulness of Selected Physicochemical Indices, Cell Membrane Integrity and Sperm Chromatin Structure in Assessments of Boar Semen Sensitivity

  • Wysokinska, A.;Kondracki, S.;Iwanina, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.12
    • /
    • pp.1713-1720
    • /
    • 2015
  • The present work describes experiments undertaken to evaluate the usefulness of selected physicochemical indices of semen, cell membrane integrity and sperm chromatin structure for the assessment of boar semen sensitivity to processes connected with pre-insemination procedures. The experiments were carried out on 30 boars: including 15 regarded as providers of sensitive semen and 15 regarded as providers of semen that is little sensitive to laboratory processing. The selection of boars for both groups was based on sperm morphology analyses, assuming secondary morphological change incidence in spermatozoa as the criterion. Two ejaculates were manually collected from each boar at an interval of 3 to 4 months. The following analyses were carried out for each ejaculate: sperm motility assessment, sperm pH measurement, sperm morphology assessment, sperm chromatin structure evaluation and cell membrane integrity assessment. The analyses were performed three times. Semen storage did not cause an increase in the incidence of secondary morphological changes in the group of boars considered to provide sperm of low sensitivity. On the other hand, with continued storage there was a marked increase in the incidence of spermatozoa with secondary morphological changes in the group of boars regarded as producing more sensitive semen. Ejaculates of group I boars evaluated directly after collection had an approximately 6% smaller share of spermatozoa with undamaged cell membranes than the ejaculates of boars in group II ($p{\leq}0.05$). In the process of time the percentage of spermatozoa with undamaged cell membranes decreased. The sperm of group I boars was characterised with a lower sperm motility than the semen of group II boars. After 1 hour of storing diluted semen, the sperm motility of boars producing highly sensitive semen was already 4% lower ($p{\leq}0.05$), and after 24 hours of storage it was 6.33% lower than that of the boars that produced semen with a low sensitivity. Factors that confirm the accuracy of insemination male selection can include a low rate of sperm motility decrease during the storage of diluted semen, low and contained incidence of secondary morphological changes in spermatozoa during semen storage and a high frequency of spermatozoa with undamaged cell membranes.

Preliminary Evaluation of Slaughter Value and Carcass Composition of Indigenous Sheep and Goats from Traditional Production System in Tanzania

  • Shija, Dismas S.;Mtenga, Louis A.;Kimambo, Abiliza E.;Laswai, Germana H.;Mushi, Daniel E.;Mgheni, Dynes M.;Mwilawa, Angello J.;Shirima, Eligy J.M.;Safari, John G.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.26 no.1
    • /
    • pp.143-150
    • /
    • 2013
  • The aim of the pilot study was to evaluate slaughter characteristics and carcass composition of indigenous long fat tailed sheep and Small East African goats purchased from the auction markets slaughtered at 1.5 to 2 yrs of age and 20 kg to 25 kg live weight. The animals were slaughtered according to halal standard procedures. The left half carcasses were jointed into eight wholesale joints, and dissected into muscles, fat and bone, which were weighed separately. Sheep had greater (p<0.05) slaughter BW (22.29 kg vs 20.50 kg) and empty BW (20.17 kg vs 18.67 kg) than goats (p<0.05). Dressing percentages were lower (p<0.001) in sheep than goats when carcass weight was expressed as percentage of slaughter BW (42.31% and 47.15%) and empty BW (46.75% and 51.79%). Sheep carcasses had lower (p<0.001) proportion (66.18% vs 71.64%) of muscles and higher (p<0.001) proportion of fat (7.41% vs 3.44%) than goat carcasses. Sheep had proportionally lighter (p<0.001) shoulder (18.89% vs 22.68%) and heavier (p<0.05) proportion of chump (7.916% vs 6.76%) and main rib (8.12% vs 7.07%). Sheep had more (p<0.001) muscles in the leg (28.83% vs 27.08%) and main rib (7.62% vs 6.36%) than goats. Sheep had less (p<0.001) muscles (20.28% vs 23.56%) in shoulder joints when expressed as percentage of total muscle of carcasses. It is concluded that there are differences in sheep and goat both in terms of carcass and joint yields and composition. The present study also implies that there is need to consider setting different meat cuts and prices for these cuts when one takes into account the differences in muscle distribution within joints in sheep and goats.

Thallium-201 Perfusion Scan in Peripheral Arterial Disease (말초성 동맥 질환에 있어서 $^{201}T1$을 이용한 말초혈관 관류스캔의 유용성)

  • Nah, Jung-Il;Woo, In-Sook;Kim, Deog-Yoon;Koh, Eun-Mi;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.192-199
    • /
    • 1991
  • Peripheral arterial disease, because of it's significant and prolonged morbidity and related mortality is a major medical and surgical problem. Contrast angiogram remains the essential standard for the anatomic demonstration of disease. It does not, however, provide data suitable for quantification or any evaluation of the microcirculation. For these reasons, radionuclide studies are playing an increasingly important role by not only confirming the diagnosis and offering objective data on the physiologic significance of anatomic lesions, but by offering prognosis of healing and prediction of therapeutic results. In addition, radionuclide procedures offer means to safely and repeatedly monitor response to therapy and long term follow up. The object of this study was to evaluate the clinical availability of $^{201}T1$ perfusion scan in patients with peripheral arterial diseases. We performed $^{201}T1$ perfusion scans in patients with five Buerger' s disease (10 legs), six DM gangrenes (12 legs) and classified three perfusion pattern groups. Finally we compared treatment modalities among each groups and compaired T1-201 perfusion scan findings with angiographic findings in six patients with Buerger's disease. The results were as follows: 1) Seven legs showed increased perfusion in stress image and normal or increased perfusion in resting image (type 1). Six legs showed decreased perfusion in stress image and improved in resting image (type II). Of total 13 legs, only 1 leg needed to amputation. 2) Three legs showed decreased perfusion in stress and resting image (type III), and subsequently all cases were received surgical amputation. 3) In six Buerger's disease patients, there were disagreements in two patients (2 legs) between $^{201}T1$ scan and angiography, in which angiograms were normal but $^{201}T1$ scans showed 'type II' perfusion patterns.

  • PDF

[ $^{99m}Tc$ ]-MDP Bone Scintigraphy Findings Representing Osteoporosis ($^{99m}Tc$-MDP 골스캔에서 골다공증을 시사하는 소견)

  • Nam, Dae-Gun;Moon, Tae-Geon;Kim, Ji-Hong;Son, Seok-Man;Kim, In-Ju;Kim, Yong-Ki
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.161-167
    • /
    • 2001
  • Purpose: Bone scintigraphy with $^{99m}Tc$-labeled phosphates is one of the most common procedures in evaluation of various skeletal disorders. Metabolic bone diseases show involvement of the whole skeleton and are associated with increased bone turnover and increased uptake of $^{99m}Tc$-labeled phosphates. In this study, we investigated apparently normal women who were examined with routine bone scintigraphy applied bone densitometry to correlate it with skeletal uptake in bone scan. Materials and Methods: This study includes 79 women who were performed both of bone mineral density(BMD) and bone scintigraphy. We investigated the relation of bone scan findings and BMD of lumbar, femur, radius. Results: Regional BMD were negatively correlated with increased age. Among the bone scintigraphy findings representing metabolic bone disease, uptakes by the long bones, skull and mandible increased with age in women, while that in the costochondral junction decreased. Increased skull and mandible uptakes is associated with decreased BMD, and it has statistically significance. Conclusion: Our results show that increased radionuclide uptake in bone scintigraphy, especially skull and mandible uptake was associated with decreased lumbar, femur BMD in women. So that, increased skull and mandible uptake in women would be a scintigraphic sign of osteopenia of osteoporosis.

  • PDF

DETERMINATION OF SUGARS AND ORGANIC ACIDS IN ORAGE JUICES USING NEAR INFRARED DIFFUSE REFLECTANCE SPECTROSCOPY

  • Tewari, Jagdish;Mehrotra, Ranajana;Gupta, Alka;Varma, S.P.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1522-1522
    • /
    • 2001
  • Beverages based on fruit juices are among the most popular commercially available drinks. There is an ever-increasing demand for these juices in the market. Orange juice is one of the most common as well as most favorite flavor. The fruit processing industries have a tremendous responsibility of quality control. For quality evaluation estimation of various components of the juice is necessary. Sucrose, glucose, fructose, citric acid and malic acid are the prime components of orange juice. Little information is available on analysis of orange juice. However, conventional and general wet chemistry procedures are currently being used which are no longer desired by the industry owing to the time involved, labor input and harmful chemicals required for each analysis. Need to replace these techniques with new, highly specific and automated sophisticated techniques viz. HPLC and spectroscopy has been realized since long time. Potential of Near Infrared Spectroscopy in quantitative analysis of different components of food samples has also been well established. A rapid, non-destructive and accurate technique based on Near Infrared Spectroscopy for determination of sugars and organic acids in orange juice will be highly useful. The current study is an investigation into the potential of Near Infrared Diffuse Reflectance Spectroscopy for rapid quantitative analysis of sucrose, glucose, fructose citric acid and malic acid in orange juice. All the Near Infrared measurements were peformed on a dispersive NIR spectrophotometer (ELICO 153) in diffuse reflectance mode. The spectral region from 1100 to 2500nm has been explored. The calibration has been performed on synthetic samples that are mixtures of sucrose, glucose, fructose, citric acid and malic acid in different concentration ranges typically encountered real orange juice. These synthetic samples are therefore considered to be representatives of natural juices. All the Near Infrared spectra of synthetic samples were subjected to mathematical analysis using Partial Least Square (PLS) algorithm. After the validation, calibration was applied to commercially available real samples and freshly squeezed natural juice samples. The actual concentrations were compared with those predicted from calibration curve. A good correlation is obtained between actual and predicted values as indicated by correlation coefficient ($R^2$) value, which is close to unity, showing the feasibility of the technique.

  • PDF

Hemodynamic evaluation of the Ionescu-Shiley pericardial xenograft heart valve (Ionescue-Shiley 인조판막을 이용한 판막대치술의 혈류역학적 성적)

  • Jeong, Won-Sang;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.17 no.2
    • /
    • pp.223-230
    • /
    • 1984
  • Since January 1977 to the end of September 1982, total 60 Ionescu-Shiley pericardial xenograft heart valves were implanted for valve replacement in 50 patients at the Han Yang University Hospital. The operative procedures were as follow: Mitral valve replacement [MVR] in 25 patients, Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 7 patients, Aortic valve replacement [AVR] in 8 patients, Aortic valve replacement [AVR] and Mitral valve replacement [MVR] in 8 patients. Aortic valve replacement [AVR] and Mitral valve replacement [MVR] and Tricuspid valve [TV] annuloplasty in 2 patients. To evaluate the immediate hemodynamic changes after valve replacements, the pressures of each cardiac chamber and ulmonary artery were checked before and after valve replacement on the operation table. Right ventricle [RV] pressure was decreased from 52.09\ulcorner6.71 to 45.57\ulcorner5.03 mmHg, Pulmonary artery [PA] pressure was decreased from 45.97\ulcorner2.69 to 41.00\ulcorner3.99 mmHg, and Left atrium [LA] pressure was decreased from 30.33\ulcorner13.02 to 22.76\ulcorner.97 mmHg before and after valve replacement. In MVR group, RV pressure was decreased from 49.17\ulcorner7.89 to 43.14\ulcorner4.14 mmHg, PA pressure was decreased from 44.67\ulcorner3.18 to 38.67\ulcorner2.85 mmHg, and LA pressure was decreased from 31.46\ulcorner13.47 to 21.91\ulcorner.17 mmHg. In AVR group, RV pressure was decreased from 53.0\ulcorner7.44 to 44.71 \ulcorner3.24 mmHg, PA pressure was decreased from 34.83\ulcorner0.73 to 31.86\ulcorner.36 mmHg, and LA pressure was not changed. In double valve replacement [MVR and AVR] group, RV pressure was decreased from 57.50\ulcorner3.82 to 42.50\ulcorner.80 mmHg, PA pressure was decreased from 51.17\ulcorner1.42 to 43.33\ulcorner4.53mmHig, and LA pressure was decreased from 34.33\ulcorner2.09 to 25.50\ulcorner0.21 mmHg. But in the group where MVR and TV annuloplasty were performed, preoperative RV and PA pressure were markedly increased and no pressure decrease in RV and PA noticed after valve replacement. This study shows good immediate postoperative hemodynamic results after valve replacement using Ionescu-Shiley xenograft valve except in the cases of MVR and TV annuloplasty and advanced disease with pulmonary hypertension.

  • PDF

Evaluation of the $HApS^{TM}$ Method for the Enumeration of Aerobic Microorganisms and Coliforms in Retailed Meat Samples in Korea

  • Keun-Seok Seo;Wonki Bae;So-Hyun Kim;Nam-Hoon Kwon;Ji-Yeun Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.3
    • /
    • pp.194-199
    • /
    • 2001
  • This study was designed to compare the effectiveness and applicability of the HApS$^{TM}$ (Hazard Analysis process System; HUKO, Seoul, Korea) based on Petrifilm$^{TM}$ (3M, St. Paul, MN, USA) with the AOAC (the Association of Official Analytical Chemists) standard total aerobic count (TAC) method and coliform count (CC) method for meat products. The comparisons were carried out using 230 meat samples collected from various retailers: 80 pork samples, 80 chicken samples, and 70 beef samples. In the comparison of the correlation coefficient (r) between conventional method and HApS$^{TM}$ method by a linear regression analysis, the correlation coefficients in total microorganism were 0.97767, 0.90712, and 0.95594 in pork, beef, and chicken samples, respectively. The correlation coefficients in coliform count were 0.82062, 0.94833, and 0.96839 in pork, beef and chicken samples, respectively. All the independent t-test on measurement values between conventional method and HApS$^{TM}$ method represented no significant differences in the means between two methods at the 0.05 of significance level($\alpha$=0.05). Based on the high correlation between HApS$^{TM}$ and the AOAC standard methods in the TAC and CC, it might be compatible to employ the HApS$^{TM}$ method to measure the microbial contamination in livestock products. HApS$^{TM}$ method was simpler and less time-consuming in sample preparation and procedures faster than the conventional method. These results suggested that the HApS$^{TM}$ method could be substitute for the conventional methods in the analysis of microbial contamination measurement in meat products.n meat products.

  • PDF

Chronological Changes of C-Reactive Protein Levels Following Uncomplicated, Two-Staged, Bilateral Deep Brain Stimulation

  • Kim, Jae-hun;Ha, Sang-woo;Choi, Jin-gyu;Son, Byung-chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.368-372
    • /
    • 2015
  • Objective : The occurrence of acute cerebral infection following deep brain stimulation (DBS) is currently being reported with elevation of C-reactive protein (CRP) level. The aim of the present study was to establish normal range of the magnitude and time-course of CRP increases following routine DBS procedures in the absence of clinical and laboratory signs of infection. Methods : A retrospective evaluation of serial changes of plasma CRP levels in 46 patients undergoing bilateral, two-staged DBS was performed. Because DBS was performed as a two-staged procedure involving; implantation of lead and internal pulse generator (IPG), CRP was measured preoperatively and postoperatively every 2 days until normalization of CRP (post-lead implantation day 2 and 4, post-IPG implantation day 2, 4, and 6). Results : Compared with preoperative CRP levels ($0.12{\pm}0.17mg/dL$, n=46), mean CRP levels were significantly elevated after lead insertion day 2 and 4 ($1.68{\pm}1.83mg/dL$, n=46 and $0.76{\pm}0.38mg/dL$, n=16, respectively, p<0.001). The mean CRP levels at post-lead implantation day 2 were further elevated at post-IPG implantation day 2 ($3.41{\pm}2.56mg/dL$, n=46, respectively, p<0.01). This elevation in post-IPG day 2 rapidly declined in day 4 ($1.24{\pm}1.29mg/dL$, n=46, p<0.05) and normalized to preoperative value at day 6 ($0.42{\pm}0.33mg/dL$, n=46, p>0.05). Mean CRP levels after IPG implantation were significantly higher in patients whose IPGs were implanted at post-lead day 3 than those at post-lead day 5-6 ($3.99{\pm}2.80mg/dL$, n=30, and $2.31{\pm}1.56mg/dL$, n=16, respectively, p<0.05). However, there was no difference in post-IPG day 2 and 4 between them (p>0.05). Conclusion : The mean postoperative CRP levels were highest on post-IPG insertion day 2 and decreased rapidly, returning to the normal range on post-IPG implantation day 6. The duration of post-lead implantation period influenced the magnitude of CRP elevation at post-IPG insertion day 2. Information about the normal response of CRP following DBS could help to avoid unnecessary diagnostic and therapeutic efforts.

Intraoperative Neurophysiological Monitoring : A Review of Techniques Used for Brain Tumor Surgery in Children

  • Kim, Keewon;Cho, Charles;Bang, Moon-suk;Shin, Hyung-ik;Phi, Ji-Hoon;Kim, Seung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.3
    • /
    • pp.363-375
    • /
    • 2018
  • Intraoperative monitoring (IOM) utilizes electrophysiological techniques as a surrogate test and evaluation of nervous function while a patient is under general anesthesia. They are increasingly used for procedures, both surgical and endovascular, to avoid injury during an operation, examine neurological tissue to guide the surgery, or to test electrophysiological function to allow for more complete resection or corrections. The application of IOM during pediatric brain tumor resections encompasses a unique set of technical issues. First, obtaining stable and reliable responses in children of different ages requires detailed understanding of normal age-adjusted brain-spine development. Neurophysiology, anatomy, and anthropometry of children are different from those of adults. Second, monitoring of the brain may include risk to eloquent functions and cranial nerve functions that are difficult with the usual neurophysiological techniques. Third, interpretation of signal change requires unique sets of normative values specific for children of that age. Fourth, tumor resection involves multiple considerations including defining tumor type, size, location, pathophysiology that might require maximal removal of lesion or minimal intervention. IOM techniques can be divided into monitoring and mapping. Mapping involves identification of specific neural structures to avoid or minimize injury. Monitoring is continuous acquisition of neural signals to determine the integrity of the full longitudinal path of the neural system of interest. Motor evoked potentials and somatosensory evoked potentials are representative methodologies for monitoring. Free-running electromyography is also used to monitor irritation or damage to the motor nerves in the lower motor neuron level : cranial nerves, roots, and peripheral nerves. For the surgery of infratentorial tumors, in addition to free-running electromyography of the bulbar muscles, brainstem auditory evoked potentials or corticobulbar motor evoked potentials could be combined to prevent injury of the cranial nerves or nucleus. IOM for cerebral tumors can adopt direct cortical stimulation or direct subcortical stimulation to map the corticospinal pathways in the vicinity of lesion. IOM is a diagnostic as well as interventional tool for neurosurgery. To prove clinical evidence of it is not simple. Randomized controlled prospective studies may not be possible due to ethical reasons. However, prospective longitudinal studies confirming prognostic value of IOM are available. Furthermore, oncological outcome has also been shown to be superior in some brain tumors, with IOM. New methodologies of IOM are being developed and clinically applied. This review establishes a composite view of techniques used today, noting differences between adult and pediatric monitoring.

Process Design and Case Study for Efficient Function Point Measurement Based on Object Oriented (객체지향 기반 효율적인 기능점수 측정 프로세스 설계 및 사례연구)

  • Kim, Dong-Sun;Yoon, Hee-Byung
    • The KIPS Transactions:PartD
    • /
    • v.15D no.3
    • /
    • pp.375-386
    • /
    • 2008
  • Recently, development paradigm of information system is turning into object oriented and component based, and this methodology is leading the software industry. To acclimatize aptly to this trend, users demand the assessment of software expenses to change with the appropriate model of computing costs of the environment, and some people are actually studying the concept of Object Oriented Function Point and UCP method. Especially, Object Oriented Function Point Measurement Process has good points in overcoming the bound of LOC and the existing the Function Point Measurement Process because Object Oriented Function Point Measurement Process is applicable to the early stage of development project mainly with the used cases, and valid to the life long period as the each stage of software products develops, and always understandable to communicate with users by the UML mark rules. Accordingly, this research is to measure Functional Point at ROFP and AOFP in accordance with the development project of information system by the national defense CBD methodology procedures and UML Interrelation Analysis that are recently and widely used in the developmental environment of object oriented information system. Furthermore, this study suggests the measurement method to obtain Functional Point, and identifies service function and object/class function in the correlation analysis of use case and class based on the products and UML modeling via traditional FPA model and object oriented FPA model. Above all, this study is to demonstrate the improvement of traditional Function Point Measurement Process, IFPUG-CPM and software cost basis, and reveal Function Point Measurement Process, which is appropriate to the development of object oriented information system, and suggest the evaluation results of the compatibility through case studies.