• Title/Summary/Keyword: Evaluation Instrument

Search Result 671, Processing Time 0.027 seconds

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Predicting Calcium and Phosphorus Concentrations in Imported Hay by near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입건초의 Ca과 P 함량 예측)

  • Lee, Bae Hun;Kim, Ji Hye;Oh, Mirae;Lee, Ki Won;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.41 no.1
    • /
    • pp.29-34
    • /
    • 2021
  • Near infrared reflectance spectroscopy (NIRS) is routinely used for the determination of nutrient components of forages. However, little is known about the impact of sample preparation and wavelength on the accuracy of the calibration to predict minerals. This study was conducted to assess the effect of sample preparation and wavelength of near infrared spectrum for the improvement of calibration and prediction accuracy of Calcium (Ca) and Phosphorus (P) in imported hay using NIRS. The samples were scanned in reflectance in a monochromator instrument (680-2,500 nm). Calibration models (n = 126) were developed using partial least squares regression (PLS) based on cross-validation. The optimum calibrations were selected based on the highest coefficients of determination in cross validation (R2) and the lowest standard error of cross-validation (SECV). The highest R2 and the lowest SECV were obtained using oven-dry grinded sample preparation and 1,100-2,500 nm wavelength. The calibration (R2) and SECV were 0.99 (SECV: 468.6) for Ca and 0.91 (SECV: 224.7) for P in mg/kg DM on a dry weight, respectively. Results of this experiment showed the possibility of NIRS method to predict mineral (Ca and P) concentration of imported hay in Korea for routine analysis method to evaluate the feed value.

Evaluation of Retrieval Accuracy of NO2 Column Density from Pandora Raw Data According to Wavelength Range and Absorption Cross-section Using DOAS Method (Pandora 원시자료로부터 차등흡수분광법을 이용하여 이산화질소 칼럼 농도 산출 시 파장 구간 및 흡수단면적에 따른 산출 정확도 평가)

  • Kim, Serin;Kim, Daewon;Lee, Hanlim
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.2
    • /
    • pp.215-222
    • /
    • 2022
  • In this study, the effect of wavelength range and absorption cross-section used to retrieve nitrogen dioxide (NO2) vertical column density (VCD) from Pandora was analyzed using Differential Optical Absorption Spectroscopy (DOAS). During the GEMS Map of the Air Pollution (GMAP) 2020 campaign, data from direct sunlight observation with Pandora instrument in Seosan was used, and NO2 VCD was retrieved under four conditions. The average NO2 VCD under the four conditions ranged from 1.22×1016~1.38×1016 molec. cm-2, with a maximum difference of 0.16×1016 molec. cm-2 between each condition. The fitting error averaged 3.19~9.59%, showing an error within 10% in all cases, and the RMS was 5.11×10-3~7.16×10-3 molec. cm-2. The retrieved NO2 VCD using 4 conditions shows a slope in the range of 0.98 to 1.09 and correlation of 0.96 to 0.98 in comparison with Pandonia Global Network (PGN).

DNN Model for Calculation of UV Index at The Location of User Using Solar Object Information and Sunlight Characteristics (태양객체 정보 및 태양광 특성을 이용하여 사용자 위치의 자외선 지수를 산출하는 DNN 모델)

  • Ga, Deog-hyun;Oh, Seung-Taek;Lim, Jae-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.23 no.2
    • /
    • pp.29-35
    • /
    • 2022
  • UV rays have beneficial or harmful effects on the human body depending on the degree of exposure. An accurate UV information is required for proper exposure to UV rays per individual. The UV rays' information is provided by the Korea Meteorological Administration as one component of daily weather information in Korea. However, it does not provide an accurate UVI at the user's location based on the region's Ultraviolet index. Some operate measuring instrument to obtain an accurate UVI, but it would be costly and inconvenient. Studies which assumed the UVI through environmental factors such as solar radiation and amount of cloud have been introduced, but those studies also could not provide service to individual. Therefore, this paper proposes a deep learning model to calculate UVI using solar object information and sunlight characteristics to provide an accurate UVI at individual location. After selecting the factors, which were considered as highly correlated with UVI such as location and size and illuminance of sun and which were obtained through the analysis of sky images and solar characteristics data, a data set for DNN model was constructed. A DNN model that calculates the UVI was finally realized by entering the solar object information and sunlight characteristics extracted through Mask R-CNN. In consideration of the domestic UVI recommendation standards, it was possible to accurately calculate UVI within the range of MAE 0.26 compared to the standard equipment in the performance evaluation for days with UVI above and below 8.

Field Elastic Wave and Electrical Resistivity Penetrometer for Evaluation of Elastic Moduli and Void Ratio (탄성계수 및 간극비 평가를 위한 현장 관입형 탄성파 및 전기비저항 프로브)

  • Yoon, Hyung-Koo;Kim, Dong-Hee;Lee, Woojin;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2C
    • /
    • pp.85-93
    • /
    • 2010
  • The shear stiffness has become an important design parameter to understand the soil behavior. In particular, the elastic moduli and void ratio has been considered as important parameters for the design of the geotechnical structures. The objective of this paper is the development of the penetration type Field Velocity and Resistivity Probe (FVRP) which is able to assess the elastic moduli and void ratio based on the elastic wave velocities and electrical resistivity. The elastic waves including the compressional and shear wave are measured by piezo disk elements and bender elements. And the electrical resistivity is measured by the resistivity probe, which is manufactured and installed at the tip of the FVRP. The penetration tests are carried out in calibration chamber and field. In the laboratory calibration chamber test, after the sand-clay slurry mixtures are prepared and consolidated. The FVRP is progressively penetrated and the data are measured at each 1 cm. The field experiment is also carried out in the southern part of Korea Peninsular. Data gathering is performed in the depth of 6~20 m at each 10 cm. The elastic moduli and void ratio are estimated based on the analytical and empirical solutions by using the elastic wave velocities and electrical resistivity measured in the chamber and field. The void ratios based on the elastic wave velocities and the electrical resistivity are similar to the volume based void ratio. This study suggests that the FVRP, which evaluates the elastic wave velocities and the electrical resistivity, may be a useful instrument for assessing the elastic moduli and void ratio in soft soils.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

Evaluation of the reliability and information quality of YouTube videos on implant overdenture (임플란트 피개의치에 관한 유튜브 영상의 신뢰도 및 질적 평가)

  • Sun-Woo Park;Seon-Ki Lee;Jin-Han Lee;Jae-In Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.3
    • /
    • pp.183-192
    • /
    • 2024
  • Purpose. This study aimed to evaluate the reliability and information quality of YouTube videos on implant overdenture searched in two languages (Korean and English). Materials and methods. Youtube, an online video sharing platform was searched using search terms in two different languages related to implant overdenture. A total of 120 videos were selected (60 videos for each search term), then the reliability and information quality of the videos were evaluated. Topic domain, DISCERN instrument, and JAMA benchmark were used to evaluate the reliability and information quality of the videos. Statistical analyses were performed by using the Mann-Whitney U test and Kruskal-Wallis test. Results. Out of a total of 120 videos, the topic domain scores of 78 (65.0%) videos were evaluated as 'poor', and the DISCERN scores of 104.5 (87.1%) videos were evaluated as 'very poor' and 'poor'. The Korean videos had significantly higher topic domain scores and DISCERN scores than the English videos (P < .05). 3.5 Korean videos and 4 English videos met the criteria for attribution of JAMA benchmark. Conclusion. The reliability and information quality of YouTube videos on implant overdenture were low.

The Development of the Korean Evaluation Scale for Hearing Handicap (KESHH) for the Geriatric Hearing Los (노인성난청을 위한 청각장애평가지수(KESHH)의 개발)

  • Ku, Ho-Lim;Kim, Jin-Sook
    • 한국노년학
    • /
    • v.30 no.3
    • /
    • pp.973-992
    • /
    • 2010
  • The hearing impairment is the representative disorder that affects the quality of the routine life of the aged period. This study was aimed to develop the Korean evaluation scale for hearing handicap(KESHH) with which we can evaluate social and psychological effects of the hearing impairment. Applying this scale clinically, we can analyze the geriatric hearing loss specifically and improve the quality of the aural rehabilitation that can help the hardness of the hearing impairment. Data were collected from 288 participants(176 hearing aid users and 112 non-hearing aid users) and the average age of the participants was 67.4 years old ( 60.15 for the hearing aids users and 78.9 for the non hearing users). The composition ratio of the male and female participants were 58.0% and 42.0% and extrovert and introvert personality were 49.3% and 50.7% showing balanced formation. The tentative draft of KESHH measurements were produced with 30 items and following 5 subscales. Using factor analysis, 6 items were erased and 4 subscales - social effect, psycho/emotional effect, interpersonal effect, and perception of hearing aids - were identified. As each subscale consisted of 6 items, 24 items were corrected and remained totally. Conclusively, the KESHH was developed with 24 items and 4 subscales including 6 items on each subscale. In addition, the KESHH was divided into type-1 and 2 depending on hearing aid users and non hearing aid users. The results of this study can be summarized as the following 5 parts. Firstly, the reliabilities of the KESHH were proved to be high because the subscales' Cronbach alpha values were from 0.723 through 0.895. Secondly, the KESHH showed systematically increasing score as the hearing impairment increased. The lowest score was 24 and the highest score was 117 and the average scores of the hearing impaired and non-hearing impaired are 72.06(SD=15.67) and 66.98(SD=20.94) showing 5.08 increased score for the hearing impaired. Depending on the degree of the hearing loss, the scores recorded 52.63 at the below of the mild hearing loss, 67.29 for the moderate hearing loss, 71.89 for the moderately severe hearing loss, and 75.57 for the severe hearing loss The comparison of the scores by hearing levels indicated that the higher the hearing levels were, the higher the scores of the KESHH with statistical significance(p<0.001). Thirdly, the correlation among 4 subscales was 0.384~0.880(p<0.001). Also, the pure tone average, personality, and the four subscales correlations showed statistical significance with 0.148~0.880 except for the pure tone average and personality and the pure tone average and perception of hearing aids. Fourthly, the total variances explained for the independent subscles were analyzed with multiple regression. The social effect was explained 17.4% with pure tone average, personality, and the status of hearing aid use variances. The psycho/emotional effect was explained 14.4% with puretone average, personality, and age variances. The interpersonal effect was explained 11.2% with pure tone average, personality, and the status of hearing aid use variances. The perception of hearing aids effect was explained 2.2% with only personality. Finally, test-retest reliability was proved to be high with 0.791(p<0.001). Conclusively, the KESHH that was developed considering Korean culture can be a useful instrument for expressing the hearing handicaps of the Korean aged hearing impaired in scores for both hearing aid users and non-users. Also, it is thought that the KESHH is useful clinically for identifying the changes of the hearing handicap scores before and after wearing hearing aids and aural rehabilitation at diverse situations.

A Study of Teaching Effectiveness on Clinical Nursing Education (임상간호 실습교육의 교수효율성에 관한 연구)

  • 김미애
    • Journal of Korean Academy of Nursing
    • /
    • v.26 no.4
    • /
    • pp.946-962
    • /
    • 1996
  • The purpose of this study was to contribute to the development of clinical instruction by students' ratings of teaching effectiveness in clinical nursing education. The subjects were comprised of graduating class 618 students from 24 nursing colleges in the nation. The instruments used in this study were "general characteristics & status of clinical nursing education" developed by the researcher and "Instrument to Measure Effectiveness of Clinical Instructors" by Reeve(1994). The 50 questions used in the questionaire were categorized into 13 components subject to factor analysis. The 13 components were interpersonal relationships, communication skills, role model, resource for students, favorable to students, encouraging to think for selves, teaching methods, evaluation, finding assignments for objectives, organization of subject matter, professional competence, knowledge of subject matter & working with agency personnel. The results of this study are as follows 1. Status of clinical nursing educaion : 1) Clinical nursing education were led by nursing professors(44.9%), a team of both nuring professor & head nurse(6.8%), instructors from specific hospital(15.1%), instuctos for a specific subject(14.6%), & head nurse(6.8%). For 3-year program students, 34.6% of the clinical nursing education were led by instructors from specific hospital & 51.4% of the education by nursing professors for Bachelor's program. 2) The contents for clinical education comprised of Conference being the most frequent of 34.5% ; a combination of Nursing skills, Orientation, Conference etc.22.0% : Nursing process 21.7% : Orientation 13.5% : Inspection(making rounds ) 6.4%, & Nursing skills of 2% being the least frequent. 3) Students' preference of clinical teachers from the highest to the lowest were instructors for a specific subject being the most desired (44.9%) followed by nursing professor, head nurse, a team of both nursing professor & head nurse, & instructors from specific hospital being the least desired. 4) Students felt that the qualification for clinical teachers should be at least a master's degree holder and 5 or more years of clinical experience. The reason they felt was because knowledge & experience are imperative for professional education. 2. Clinical teaching effectiveness : The total points for teaching effectiveness was 147.97(mean of 2.95±0.98) where the total score is considered to be an average rating. 3. Teaching effectiveness as status of clinical nursing education : 1) The score ratings for the clinical instructors from the highest to the lowest were as follows : instructors for a specific subject, instructors from specific hospitals, a team of both nursing professors & head nurses, nursing professors, head nurses, which resulted in significunt difference(F=4.53, P<0.001). 2) The rating scores based on the teaching program from the highest to the lowest were as follws ; nursing skills, nursing process, a combination of nursing skills, orientation, conference etc. , conferences, orientation, inspection, which resulted in significunt difference(F=10.97, P<0.001). 4. Based on 13 categorized components from the questionaires, questions related to communication skills scored the highest points of 3.20 where inquiries regarding resource for students scored the lowest points of 2.38. 5. Among the 13 categorial components from the questionaire, Interpersonal relationship, Communication skills, Resource for students, Encouraging to think for selves, Evaluation, Teaching method, Finding assignment for objectives, Organization of subject matter, Professional competence, & Working with agency personnel, instructors for a specific subject scored the highest points and head nurse scored the lowest, which resulted in significant difference. Favorable for students, instructors for a specific subject scored highest points and nursing professor scored the lowest, which resulted in significant deference (F=5.39, P<0.001). Role model & Professional competence, instructors for a specific subject scored the highest points and head nurse scored the lowest, with minimum variation(F=1.29, P>0.05 : F=1.64, P>0.05) 6. Based on 13 categorial components as a whole, the highest points scored among the 5 groups of clinical teachers was instructors for a specific subject and the lowest, by head nurse(F=1.94, P<0. 001). A team of both nursing professor & head nurse attained higher score in clinical education than their independent education.

  • PDF

Reliability of Muscle Evaluation with a Tactile Sensor System (촉각센서를 이용한 근육평가의 신뢰도 조사)

  • Oh, Young-Rak;Lee, Dong-Ju;Kim, Sung-Hwan;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.3
    • /
    • pp.337-344
    • /
    • 2005
  • A tactile sensor employs a piezoelectric element to detect contact frequency shifts and thereby measure the stiffness or softness of material such as tissue, which allows the sensor to be used in many fields of research for urology, cardiology, gynecology, sports medicine and caner detection and especially for cosmetics and skin care. In this study, reliability of the tactile sensor system was investigated with its manual application to the muscles susceptible to temporomandibular disorders. Stiffness and elasticity of anterior temporalis, masseter and trapezius muscles were calibrated bilaterally from 5 healthy men with an average of 24.5$\pm$0.94 years. The tactile sensor used in this study had a computer-controlled and motor-driven sensor unit which automatically pressed down on the skin surface over the muscles being measured and retracted, thereby providing the hysteresis curve. The slope of the tangent of the hysteresis curve (${\Delta}f/{\Delta}x$) is defined as stiffness of the muscle being measured and the distance between the two parts of the curve as its elasticity. To determine inter-examiner reliability, all the measurements were performed by the two examiners A and B, respectively and the same examination were repeated with an interval of 2 days for intra-examiner reliability. The results from this study demonstrated high reliability in measuring stiffness and elasticity of anterior temporalis, masseter and upper trapezius muscles using a tactile sensor system. It is suggested that the tactile sensor system can be a highly reproducible and effective instrument for quantitative evaluation of the muscle in head and neck region.