• Title/Summary/Keyword: Evaluation Instrument

Search Result 664, Processing Time 0.03 seconds

Development and Validation of the Core Competency Evaluation Tool for New Graduate Nurse's Preceptor (신규간호사 프리셉터의 핵심역략 평가도구 개발)

  • Kwon, In-Gak;Jung, Kyoung-Hee;Cho, Hye-Sool;Hwang, Ji-Won;Kim, Ji-Young;Jeon, Kyoung-Ok;Sung, Young-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.8 no.4
    • /
    • pp.535-549
    • /
    • 2002
  • Purpose : The purpose of this study was to develop a core competency evaluation tool of the preceptors training new graduate nurses and to determine the validity of the developed instrument. Method : This study was conducted in 2 phases. In phase I, preceptor's core competency list was developed through literature review, focus group interview, and review by nursing directors and nurse managers. In phase II, 60 preceptors were evaluated with the developed instrument and categorized into excellent, good & poor core competency groups. For validation of the instrument, new graduates' clinical performance improvement and satisfaction with preceptor were compared between excellent and poor group. Result : The data were analyzed by SPSS P.C and the results were as follows. 1) Preceptor's core competencies were classified into three domains; Role model(10 items), Socialization facilitator(8 items), and Educator(16 items), and each item had four point system of "strongly agree" to "strongly disagree". Cronbach'${\alpha}$ of the instrument was.9416. 2) Comparison of clinical performance improvement and satisfaction with preceptor of the new graduates trained by excellent and poor preceptors revealed that new graduates' clinical performance improvement(p=.015) and satisfaction with the preceptor(p=.005) were significantly higher in the excellent core competency preceptor group than the poor core competency preceptor group. Conclusion : The validity of the preceptor's core competency evaluation tool developed in this study was confirmed. Therefore, this tool can be effectively utilized for education and evaluation of new graduates' preceptors in clinical settings.

  • PDF

A Study of Evaluation Index Development of Healthcare Rehabilitation Device Design (헬스케어 재활훈련기 디자인 평가 요소 개발에 관한 연구)

  • Cho, Jae Sang;Kwon, Tae Kyu;Hong, Jung Pyo
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.129-142
    • /
    • 2014
  • Due to the increase of the aged population and population of the disabled today, there is a growing demand for rehabilitation medical instruments. Furthermore, there is a growing demand for evaluation indices for services that should be provided for uses of the rehabilitation medical instruments. In order to evaluate rehabilitation medical instrument designs in this study, the basic index for design evaluations shall be identified to search for assessment plans. Through this, new evaluation indices will be deduced through discussions and analysis of rehabilitation medical experts, biomedical engineers, and designers. The results of this study are summarized as follows. First, the existing design evaluation indices were collected and analyzed to construct 10 rehabilitation medical instrument design evaluation indices and 44 sub-evaluation items. These will be important evaluation standards for designing rehabilitation medical instruments in the future. Second, the design evaluation indices that must be taken into consideration when developing health care rehabilitation medical instruments are the 10 design evaluation indices of usability, cognition, safety, learning, motility, durability, economic feasibility, space, aesthetics and environmental aspects. Third, design evaluation indices of environment, space, cognition, usability, economic feasibility and aesthetics are indices that must be taken into consideration for product design, while learning, safety, motility and durability are factors that must be given special consideration for rehabilitation medical instrument design evaluation indices. Fourth, if existing product design evaluation indices placed importance on environment, space, cognition, usability, economic feasibility and aesthetics of products for design evaluation indices, rehabilitation medical instrument design evaluation indices placed importance on learning, safety, motility and durability on top of usability and economic feasibility, which are the differences between the design evaluation indices of rehabilitation medical instrument and other product designs. The 10 rehabilitation medical device design evaluation indices and 44 sub-evaluation items were carried out in this study. This research is only on the overall rehabilitation medical device design evaluation indices. In future research, the evaluation indices will be applied in the actual rehabilitation medical design device through production of prototypes, while making revisions and supplementations where necessary.

Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator (저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발)

  • Lee, Young Seob;Jung, Jae Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device (전원용 SPD의 건전성 평가 장치 개발)

  • Chang, Sughun;Kim, Youngjin;Kim, Sungju;Kim, Jaehyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.

Standardized Design of the Transmitting Coils in Inductive Coupled Endoscope Robot Driving Systems

  • Ke, Quan;Jiang, Pingping;Yan, Guozheng
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.835-847
    • /
    • 2017
  • A transmitting coil with an optimal topology and number of turns can effectively improve the performance of the wireless power transfer (WPT) systems for endoscope robots. This study proposes the evaluation parameters of the transmitting coils related to the performance of the WPT system to standardize the design of the transmitting coils. It considers both the quality factor of transmitting coils and the coupling factor between the two sides. Furthermore, an analytical model of transmitting coils with different topologies is built to exactly estimate the evaluation parameters. Several coils with the specified topologies are wound to verify the analytical model and the feasibility of evaluation parameters. In the case of a constant power received, the related evaluation parameters are proportional to the transfer efficiency of the WPT system. Therefore, the applicable frequency ranges of transmitting coils with different topologies are determined theoretically. Then a transmitting coil with a diameter of 69 cm is re-optimized both theoretically and experimentally. The transfer efficiency of the WPT system is increased from 3.58% to 7.37% with the maximum magnetic field intensity permitted by human tissue. Finally, the standardized design of the transmitting coil is achieved by summing-up and facilitating the optimization of the coils in various situations.

A Survey of Teaching Effectiveness and the Development of an Evaluation Instrument for Clinical Education (임상실습지도자의 효율성 조사와 임상평가도구 개발)

  • Kwon, Mi-Ji
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.1
    • /
    • pp.177-186
    • /
    • 2002
  • The purpose of this study was to contribute to the development of clinical instruction by students ratings of teaching effectiveness in clinical education. The instrument used in this study was teaching effectiveness of clinical nursing by Yu and modified evaluation method by Kern and Mickelson. The results were are follows 1. Among the 12 categorial components of clinical teaching effectiveness, the highest satisfaction was 'encouraging to think for themselves' and the lowest was 'attitude of teacher and evaluation' 2. To compare teaching effectiveness between sex, 'resource for student' and 'professional competence' showed statistical significance. 3. To compare teaching effectiveness among clinical practice stage, 'encouraging' 'role model', 'professional competence', 'organization of subject mater' and 'attitude of teacher and evaluation' showed statistical significance. 5. Interrater ICCs for evaluation method did not showed statistical significance and interitem ICCs showed statistical significance. This article presents goal of clinical education, development of clinical instructor's educational program and a standardized method to measure clinical performance.

  • PDF

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

Evaluation of BSR Noise Properties of Instrument Panel in a Vehicle (자동차 계기판 BSR 소음특성 평가)

  • Shin, Su-Hyun;Cheong, Cheol-Ung;Kim, Duck-Whan;Jung, Sung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.330-331
    • /
    • 2010
  • In this paper, BSR noise from an instrument panel of a vehicle are investigated with integrated experimental methods. First, potential source regions of the instrument panel for BSR are localized by using the module-excitor and near-acoustic field visualization system. Then, subjective evaluation of BSR nosie from the detected potential noise source regions is made with the Zwicker's loudness and time-varying loudness methods.

  • PDF

Development of an Evaluation Instrument for Subjects Related to Death (죽음 관련 교과목의 교과내용 평가 도구개발)

  • Jo, Kae-Hwa;Lee, Hyun-Ji;Lee, Yun-Joo
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.1
    • /
    • pp.74-83
    • /
    • 2006
  • Purpose: The purpose of this study was to develop an evaluation instrument integrated and interdisciplinary death education for the human service areas such as nursing, social welfare, and education and to test the reliability and validity of it. Method: The subjects used to verify the instrument's reliability and validity were 407 students who were enrolled in the departments of nursing, social welfare, and education in universities located in Seoul, Pusan, Daegu, and Daejeon. The data was collected from April to May, 2005, and was analyzed by SPSS/WIN 12. Result: A factor analysis was conducted. Items with over a .40 factor loading and over a 1.0 eigen value were selected. Nine identified factors were learning about death, role of professionals, personal attitudes, hospice care, ethics and legal issues, death and dying, spiritual aspect of' death, transcultural aspect of death, and multidisciplinary theory of death. The instrument consisted of 44 items and the reliability was a cronbach's of .953 Conclusion: Based on the study results, the content scale developed in this study was identified as a tool with a high degree of reliability and validity.

THE EFFECT OF GUTTA-PERCHA REMOVAL USING NICKEL-TITANIUM ROTARY INSTRUMENTS (엔진 구동형 니켈 티타늄 파일을 이용한 거터퍼쳐의 제거 효과)

  • Jeon, Jeong-Hun;Min, Jeong-Beom;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.212-218
    • /
    • 2004
  • The purpose of this study was to quantify the amount of remaining gutta-percha/sealer on the walls of root canals when three types of nickel-titanium rotary instruments (Profile. ProTaper and $K^3$) and a hand instrument(Hedstrom file) used to remove these materials. The results of this study were as follows: 1. In the total time for gutta-percha removal. Profile group was the fastest and followed by $K^3$, Protaper, Hedstrom file group. 2. In case of the evaluation of the volume of remained gutta-percha from radiograph. $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. 3. In case of the evaluation of the volume of gutta-percha remained from stereomicroscope, $K^3$ group got the highest score and followed by Protaper. Hedstrom file. Profile group in the apical 1/3. These results showed that instrumentation using nickel-titanium rotary instrument groups was faster than that using hand instrument group. The effect of gutta-percha removal using Profile group was better than that using Protaper and $K^3$ group in the nickel-titanium rotary instrument groups.