• 제목/요약/키워드: Evaluation Equation

Search Result 1,437, Processing Time 0.032 seconds

Assessing the Unit Load Reduction Equation of Drainage Outlet Raising Management in Paddy Fields (논 물꼬관리 기법 적용에 따른 원단위 삭감부하량 산정식 평가)

  • Kim, Dong-Hyeon;Oh, Heung-Keun;Jang, Taeil;Ham, Jong-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.2
    • /
    • pp.35-45
    • /
    • 2023
  • The DOR (Drainage outlet raising) in the paddy field has been suggested as one of the most important best management practices for the TMDL (Total maximum daily load) management in the technical guidelines by the NIER (National institute of environmental research). However, this method is underestimated and is not well adopted by local governments for the TMDL. The purpose of this study is to evaluate the unit load reduction equation according to the application of DOR in order to expand this equation. The original equation in the guideline was derived using the HSPF (Hydrological Simulation Program-Fortran) model for 1 year in Changnyeong. We analyzed the reduction effect of the original equation application by collecting additional long-term monitoring data from the Buan, Icheon, Iksan, and Jeonju. When comparing the reduction loads between the original equation and monitoring results, the evaluation results of the original equation were 11% of the monitoring analysis results, which was underestimated. This means that the original equation needs to be improved. For assessing the equation, the HSPF Paddy-RCH model was established according to the NI ER guideline and evaluated for applicability. The performance results of the model showed a reasonable range by the statistical criteria. Modified equations 1 and 2 were proposed based on the monitoring and modeling results. Modified equation 1 was the method of modifying the original equation's main factors, and modified equation 2 was the method of applying the non-point pollution reduction efficiency according to the rainfall class using the long-term modeling results. At the level of 58.6~64.6% of monitoring data, the difference between them could be further reduced compared to the original equation. The suggested approach will be more reasonable and practicable for decision-makers and will contribute to the TMDL management plans.

Verification of Proposed Design Equation for Stress Evaluation of Unbonded Tendons (비부착 긴장재의 응력을 평가하기 위해 제안된 설계식의 타당성검증)

  • Lim, Jae-Hyung;Moon, Jeong-Ho;Lee, Li-Hyung
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.127-137
    • /
    • 1999
  • In the previous study in relation to the current study, a test program for the verification of the proposed design equation was carried with fourteen prestressed concrete beams with unbonded tendons. Experimental results were compared with the computed results by the proposed design equations. The previous design equations are ACI code, AASHTO LRFD code, the analysis equation with the strain compatibility, Harajli/Kanj' design equation, Chakrabarti' design equation. As a result of comparative studies, it turned out that the proposed design equation could predict the ultimate tendon stress with comparatively high accuracy.

Coupling loss factor evaluation using loss factor based on the SEA (SEA에 기초를 둔 손실계수를 이용한 결합계수의 평가)

  • 안병하;황선웅;김영종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.568-571
    • /
    • 1997
  • The overall aim of this paper is to determine coupling loss factor using loss factor and structural loss factor. For this purpose, two kinds of loss factor were adopted. One is loss factor of each sub structure, another is structural loss factor based on the complex welded or assembled structure. Using these two parameters, it is possible to derive the coupling loss factor which represent characteristic condition of SEA theory. Coupling loss factor of conjunction in complex structure was expressed as power balance equation. The derived equation for a coupling loss factor has been simplified on the assumption of one directional power flow between two sub structures. Using these conditions, it is possible to find the coupling loss factor equation. The comparison between theory of power transmission on conjunction and above equation, show a good agreement in simple beam structure. To check the effectiveness of above equation, it was adopted rotary compressor. Rotary compressor has three main conjunctions between shell and internal vibration part. This equation was applied to find out the optimum welding point with respect to reduce the noise propagation. It shows the effective tool to evaluate the coupling loss factor in complex structure.

  • PDF

Improvement Scheme of Simplified Liquefaction Potential Evaluation for a Dredged and Reclaimed Ground (준설매립지반의 액상화 간편예측 개선에 관한 연구)

  • Jung, Min-Hyung;Kim, Ju-Hyun;Jeong, Sang-Guk;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.8
    • /
    • pp.47-57
    • /
    • 2007
  • In this study, the analysis of density characteristics of some dredged and reclaimed ground sites, which is necessary for liquefaction evaluation of a dredged and reclaimed ground, was conducted. From analyzing a simplified liquefaction potential evaluation using SPT-N values which have been applied as domestic earthquake-resistant design criterion, improvement scheme is suggested. Based on the analysis result of density characteristics, it was found out that the relative density and the intial N-value ranged respectively $40{\sim}50%\;and\;5{\sim}8$. In the case of applying Liao & Whitman's equation to correct effective overburden pressure, liquefaction resistance of the upper ground that is relatively weaker than that of lower ground is overestimated. So, Skempton's equation is recommended. And the N value with depth which is applied for design process should be estimated by the exponential equation, $N=1.35{\sigma}'^{0.75}$.

A three-dimensional patent evaluation model that considers the factors for calculating the internal and external value of a patent: Arrhenius chemical reaction kinetics-based patent lifespan prediction (특허의 내적.외적 가치산정요인을 고려한 입체적 특허평가모델: 아레니우스 화학반응속도론 기반의 특허수명예측)

  • Choi, Yong Muk;LEE, JAEWON;Cho, Daemyeong
    • Journal of Digital Convergence
    • /
    • v.19 no.6
    • /
    • pp.113-132
    • /
    • 2021
  • This study is a new evaluation using the Arrhenius equation, which is known as the chemical reaction rate estimation equation, to evaluate the intrinsic and extrinsic value elements of patents as a model. The performance of the evaluation model was superior to the SVM, Logistic reg. and ANN models that were used as patent evaluation models in prior studies. In addition, there was a strong correlation between the predicted lifespan of the patent and the actual lifespan of the patent. These evaluation models may be used for evaluation purposes only, or if an evaluation is required, including a commercialization entity or technical characteristics.

Put English Title Here (새마을열차 환경소음 예측식 성능 비교에 관한 연구)

  • Cho, Jun-Ho;Koh, Hyo-In;Kim, Jae-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.105-108
    • /
    • 2007
  • Recently, due to the high interests for well being life, claims about noise ad vibration are increased very rapidly. Therefore more reliable and exact evaluation of noise impact has been required. Until now in Korea, only one prediction equation for the assessment of railway environmental noise was used. But that equation has many limits and weak points because of the update was not performed from 1993. So in this study, the performance of another equation proposed by authors was compared to the former. As a result, proposed prediction equation may be used to evaluate the impact of railway noise in the future.

  • PDF

Turbulent flow fields analysis using CFDS scheme (CFDS기법을 이용한 난류 유동장 해석)

  • Moon S. M.;Lee J. S.;Kim C.;Rho O. H.;Hong S. K.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.51-59
    • /
    • 2001
  • An evaluation of one zero-equation and two one-equation eddy viscosity-transport turbulence closure models as implemented CFDS(Characteristic Flux Difference Splitting ) code is presented herein. Comparisons of Baldwin-Lomax model as zero-equation and Baldwin-Barth and Spalart-Allmaras model as one-equation are presented for three test cases, first inlvolving the 3 dimensional supersonic flow at M=1.98 over tangent ogive cylinder, second involving the 2 dimensional transonic flow at M=0.79 over RAE 2822 airfoil, third involving the 3 dimensional transonic flow at M=0.84 over ONERA M6 wing. The numerical results of CFDS code will also examined through direct comparison with experimental data.

  • PDF

Error Evaluation of the Linearized Equation of Servo Valve in Hydraulic Control Systems (유압 서보 제어계에서 밸브 선형화 방정식의 오차 평가)

  • Kim, Tae-Hyung;Lee, Ill-Yeong
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.501-506
    • /
    • 2001
  • In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.

  • PDF

Bursting Force Equation for Design in Unbonded Post-Tensioned Anchorage Zone (비부착 포스트텐션 정착구역 설계를 위한 파열력 산정 방법)

  • Ro, Kyong Min;Lee, Young Hak
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.21-26
    • /
    • 2018
  • For evaluating equations of bursting force in different codes, comparative study of the formulas was conducted. Because the equations does not consider variables such as shape of anchorages and duct, a relation between the bursting forces and the variables has to be analyzed. In this paper, the bursting forces equation was proposed by finite element analysis. As evaluation through comparison of the proposed equation with the previous ones and an experiment, it was figured out that bursting force computed by the proposed equation could be used for design of reinforcement in the anchorage zone.