• 제목/요약/키워드: Evaluation Chart

검색결과 272건 처리시간 0.027초

Investigation on Regional Distribution of Potential Energy Production with Agricultural By-Products in Agricultural Sector

  • Park, Woo-Kyun;Lee, Sun-Il;Shin, Joung-Du;Kim, Gun-Yeob;Kim, Yi-Hyun;So, Kyu-Ho
    • 한국토양비료학회지
    • /
    • 제46권5호
    • /
    • pp.343-350
    • /
    • 2013
  • The objectives of this study were to estimate the potential biomass yield by using the biomass conversion index and evaluate the potential energy production by using the energy conversion index of biomass. Estimating the total biomass yield in Korea showed 9,646.3 thousand tons produced in 2012. Subsequent evaluation of the potential energy production using the estimated biomass yield in 2012 indicated that the calorific values were varied from 3,800 to 4,500 kcal $kg^{-1}$ for crop- and from 4,100 to 4,300 kcal $kg^{-1}$ for woody-based biomass, respectively. Among the examined biomass materials, the pruned branch of a nut tree appeared to be the greatest in bio-energy production showing 6,300 kcal $kg^{-1}$ in calorific value. Total potential energy production from agricultural by-products was estimated approximately at 3,966,000 TOE. Among the agricultural by-products examined, rice straw showed the greatest energy production potential being at 2,321,000 TOE. Furthermore, it might contribute to establishing the countermeasures of biomass utility in agricultural sector based on regional distribution chart of the potential biomass and energy yields in Korea.

급성 진정제 중독 추정 환자에서 플루마제닐의 투여: 위험도/이익 재평가 (Flumazenil administration in suspected patients with acute hypnotics and sedatives poisoning: risk-benefit re-evaluation)

  • 허재홍;최상천;임용균;샘슨램포탕;박은정
    • 대한임상독성학회지
    • /
    • 제14권2호
    • /
    • pp.92-99
    • /
    • 2016
  • Purpose: The use of flumazenil administration in the emergency department is still controversial because of concerns about adverse effects. The present study was conducted to re-evaluate the risk-benefit ratio associated with flumazenil administration to patients suspected of having acute hypnotics and sedatives poisoning in the emergency department. Methods: A retrospective chart review study was conducted for patients whose final diagnoses were "poisoning" and "benzodiazepine" or "sedatives-hypnotics" from Mar. 2006 to Feb. 2015. The basal characteristics of the patients, including past medical history, ingredients and dose of ingested drug and co-ingested drugs were investigated. For patients administered flumazenil, responsiveness and time from admission to flumazenil administration were investigated with supplement. All collected data were analyzed in aspect terms of risk/benefit. Results: A total of 678 patients were included in our study. Benzodiazepine was the most common sedative/hypnotic drug prescribed, and the frequency of prescription continuously increased. The proportion of TCA as co-ingestion decreased from 13.1% to 3.9% in patients with acute sedative/hypnotic poisoning. Flumazenil was administered to 55 patients (8.1%), of which 29 patients (52.7%) were applied to contraindications. Fifty-three patients (96.4%) showed positive responsiveness, including partial responsiveness after flumazenil administration. No severe adverse events were identified. Conclusion: Based on the current trends in prescription patterns for sedative/hypnotic drugs, increased use of non-TCA antidepressants, and responsiveness to administration of flumazenil, benefit seemed weighted more in this study, although the observed benefits were based on limited results. Further prospective multicenter studies will be needed to optimize benefit-risk ratio.

Evaluation of Kinetic Parameters and Thermal Stability of Melt-Quenched BixSe100-x Alloys (x≤7.5 at%) by Non-Isothermal Thermogravimetric Analysis

  • Ahmad, Mais Jamil A.;Abdul-Gader Jafar, Mousa M.;Saleh, Mahmoud H.;Shehadeh, Khawla M.;Telfah, Ahmad;Ziq, Khalil A.;Hergenroder, Roland
    • Applied Microscopy
    • /
    • 제47권3호
    • /
    • pp.110-120
    • /
    • 2017
  • Non-isothermal thermogravimetry (TG) measurements on melt-quenched $Bi_xSe_{100-x}$ specimens (x=0, 2.5, 7.5 at%) were made at a heating rate ${\beta}=10^{\circ}C/min$ in the range $T=35^{\circ}C{\sim}950^{\circ}C$. The as-measured TG curves confirm that $Bi_xSe_{100-x}$ samples were thermally stable with minor loss at $T{\leq}400^{\circ}C$ and mass loss starts to decrease up to $600^{\circ}C$, beyond which trivial mass loss was observed. These TG curves were used to estimate molar (Se/Bi)-ratios of $Bi_xSe_{100-x}$ samples, which were not in accordance with initial composition. Shaping features of conversion curves ${\alpha}(T)-T$ of $Bi_xSe_{100-x}$ samples combined with a reliable flow chart were used to reduce kinetic mechanisms that would have caused their thermal mass loss to few nth-order reaction models of the form $f[{\alpha}(T)]{\propto}[1-{\alpha}(T)]^n$ (n=1/2, 2/3, and 1). The constructed ${\alpha}(T)-T$ and $(d{\alpha}(T)/dT)-T$ curves were analyzed using Coats-Redfern (CR) and Achar-Brindley-Sharp (ABS) kinetic formulas on basis of these model functions, but the linearity of attained plots were good in a limited ${\alpha}(T)-region$. The applicability of CR and ABS methods, with model function of kinetic reaction mechanism R0 (n=0), was notable as they gave best linear fits over much broader ${\alpha}(T)-range$.

웨이블릿을 이용한 주기 신호 데이터의 이상 탐지에 관한 연구 (A Study on Fault Detection of Cycle-based Signals using Wavelet Transform)

  • 이재현;김지현;황지빈;김성식
    • 한국시뮬레이션학회논문지
    • /
    • 제16권4호
    • /
    • pp.13-22
    • /
    • 2007
  • 주기 신호 데이터를 가지는 공정의 이상 탐지를 위해 대표값을 사용하는 단변량 SPC 차트나 PCA, PLS 등과 같은 다변량 통계방법들이 사용되고 있다. 이러한 방법들은 주기 신호 데이터의 다양한 정보를 분석하는데 한계가 있다. 본 연구에서는 Haar 웨이블릿 변환을 이용하여 주기 신호의 형태를 반영하는 웨이블릿 계수를 구하고, 이 계수들에 SPC 차트를 적용하여 공정 이상여부를 탐지하였다. 본 논문에서는 보다 효율적인 이상 신호 탐지를 위해 웨이블릿을 이용한 잡음 제거 기법과 Haar 웨이블릿 계수의 분산 차이를 이용한 중요 계수 선택 방법을 제안하였다. 다양한 이상 상황에 대하여 시뮬레이션을 통하여 제안한 알고리즘의 효율성을 확인하였다.

  • PDF

인터넷 의류 쇼핑몰에 대한 소비자 만족도 평가 -의류 치수체계를 중심으로 - (Evaluation of Customer Satisfaction on the Internee Apparel Shopping Mall - Focused on Apparel Sizing System -)

  • 이경화;조재희
    • 복식
    • /
    • 제51권3호
    • /
    • pp.129-139
    • /
    • 2001
  • The purpose of this study is to suggest the standard size specification of the apparel item as finding out apparel products'sizing problem in the domestic and foreign interned shopping malls. Though that, to suggest basic data of web page offered sizing system given to consumer higher satisfaction and based on ISO (International Organization For Standardization), domestic industry standard and service related size. The summarized findings are as follow. 1. The result of size description research, the size description system between internet site were very different, in addition in the department shopping malls it was different by manufacturing industry. Also in domestic and foreign shopping malls, It was not correspond to ISO and domestic industry standard, used Numeric and Alphabetical size. In the foreign shopping mall it distinguish body type and age group. 2. The result of consumer's satisfaction, the superior fashion malls were Samsung, LG, Fashionpia in the domestic shopping mall, were Gap, JCPenny, Jcrew in the foreign shopping malls. In the total group, 1-5 grades were ranked in the foreign shopping malls. 3. Satisfaction of the foreign fashion mall was higher than that of the domestic fashion malls. Exactly, foreign fashion mall described size chart, size description, product size and body size measuring method but domestic fashion malls didn't describe that. Domestic fashion malls need sizing system development given to consumer higher satisfaction. In addition sizing system based on ISO and domestic industry standard and subdivided to body type and ale group must be studied. Aloe, fashion information, coordination information and product explanation must be reinforced.

  • PDF

족관절 삼과 골절에 대한 치료 후 결과 비교 (Comparison of the Results after the Surgical Treatments of the Trimalleolar Ankle Fractures)

  • 라종득;박현수;임창석;장영수;박상원;정태원;전용수
    • 대한족부족관절학회지
    • /
    • 제8권1호
    • /
    • pp.86-91
    • /
    • 2004
  • Purpose: To evaluate the methods and results of the surgical treatment in the trimalleolar fracture of the ankle. Materials and Methods: We analysed the results of the ankle trimalleolar fracture which were treated with open reduction and internal fixation from January 1999 till September 2003. There were 45 patients who had at least six months follow up, 16 men, and 29 women. We have analysed the mechanism of injury, methods of operation and postoperative complications. Results: The results were assessed on ankle AP, lateral and mortise X-rays and retrospective chart review. There were 30 supination-external rotation, 13 pronation-external rotation, 2 pronation-abduction in the mechanism of injury by Lauge-Hansen classification. Cases of the posterior malleolar fracture which involved more than 25% of the weight bearing surface were 7 (15.6%). Medial malleolar mono-fixation was done in 5 cases, fibular mono-fixation in 2 cases, bimalleolar fixation in 32 cases, trimalleolar fixation in 6 cases. 38 cases (84.4%) were good or excellent in clincal assessment and 39 cases (86.7%) were good or excellent in radiological assessment according to the criteria of the Meyer. There was no difference of results among the surgical treatment methods. Conclusion: The results of our study indicate that the rigid fixation with early ankle motion and weight bearing is needed in ankle trimalleolar fracture. But minimal fixation is not bad in slight displaced fracture. Both anterior approach and posterior approach were useful methods to stabilization the posterior malleolar fracture. And pre-operative evaluation to detect the hidden soft tissue injuries and fracture mechanism is very important to avoid the failure.

  • PDF

Image J 프로그램을 이용한 격자집속거리와 격자비에 따른 영상비교평가 (Using Image J program, compared of focusing distance and grid rate)

  • 서원주;서정범;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.37-42
    • /
    • 2012
  • Pediatric head and neck phantom, using the rate by focusing distance and grid images, Image J using the Quality Assessment and Dose Area Product compared. X-ray laboratory equipment due to the Philips Digital DIAGNOST a 110 cm FFD set and using ACE Non-grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Focused grid, Acryl Phantom (Fluke Model 76-2 Series Phantom) 15.24 cm, by resolution chart image acquisition, image evaluation program (Image J Ver. 1.4.3.67, USA) imaging experiments were analyzed using. Dose Area Product in the Non Grid 0.028 $mGy{\cdot}cm^2$, focusing distance 110 cm (12 : 1), the 0.129 $mGy{\cdot}cm^2$, 140 cm (12 : 1), the 0.135 $mGy{\cdot}cm^2$, 180 cm (8 : 1) was measured with a 0.110 $mGy{\cdot}cm^2$ Non Grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Image obtained when grid using the image J program focusing distance 110 cm with grid based on the measured SNR and PSNR Non Grid if the SNR the 17.307 dB, PSNR of the 20.002 dB, if the SNR 28.755 dB, PSNR was measured by the 31.451 dB. Image J image analysis through the streets, rather than focusing on grid by the rate that could see an increase in dose. Select the grid by a small dose rate reduction is possible.

  • PDF

유리 생비골 및 생비골 피부편 이식 후 공여부의 평가 (The Evaluation of Donor Site after Transfer of Free Osseous and Osteocutaneous Flap of Fibula)

  • 이광석;한승범;황인철;송형석
    • Archives of Reconstructive Microsurgery
    • /
    • 제10권2호
    • /
    • pp.75-80
    • /
    • 2001
  • Purpose : We have evaluated the morbidity of donor site after transfer of free fibular osseous and osteocutaneous flap to defect site of bone and soft tissue due to chronic osteomyelitis of long tubular bone, open fracture with bony defect, bone or soft tissue tumor and congenital anomaly. Materials and methods : The 54 cases of 79 cases to be carried out from May, 1982 to May, 2001 which could be followed up were reviewed. There were forty nine in male and five in female. The mean age was 35(4 to 66)years old and mean follow up period is 21.3 month(12 to 72). We have retrospectively analyzed the various postoperative complications such as compartment syndrome, donor site infection, skin defect, hypesthesia, hammer toes, ankle instability and activity of daily living by help of questionnaire, telephone, physical examination, follow up x-ray study and chart. Results : In the total 54 cases the medication period for pain control after operation were classified into three groups under 2 weeks(49 cases), from 2 weeks to 6 weeks(3 cases) and over 6 weeks(2 cases). The postoperative morbidity were occurred in total 12 cases(compartment syndrome: 0, infection : 2, skin defect: 1, hypesthesia: 5, hammer toe: 2 ankle pain: 2 discomfort in activity of daily living: 0), and also the morbidity rates of donor site were 23.5% in osseous flap and 21.6% in osteocutaneous flap were occurred. There was no statistical significonce in morbidity between osseous and osteocutaneous free fibular flap transfer(P>0.05). Discussion : In general the morbidity of free fibular flap transfer was relatively high but it did not have any effect on daily activity of living. We think that the meticulous operation technique, detailed wound care and early range of motion exercise will reduce the morbidity of donor site of flap.

  • PDF

부항요법에 의한 배수혈 혈색소 변화의 정량적 측정 시스템 개발 및 유의성 평가 (Evaluation of Significance & Development of Quantitative Measurement System for Acupoint Pigmentation by Cupping Therapy)

  • 김수병;이나라;정병조;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제28권3호
    • /
    • pp.63-71
    • /
    • 2011
  • Objectives : The aim of this study is to develop the system and evaluate the optical analytical technique that reflects acupoint pigmentation and extravasated blood by cupping. Methods : We designed the system able to express XYZ coordinate on local skin color. To evaluate measurement-accuracy, we compared with 24 Color Checker Chart by standardized Commission Internationale de l'Eclairage. After confirming the performance of system, we experimented with cupping which was 80 kPa negative pressure for 1 minute on left/right BL13. The X, Y and Z values were converted to R, G and B, $L^*$, $a^*$ and $b^*$, Erythema Index (E.I.), and Melanin Index (M.I). We compared and analyzed two cases on before/after cupping. Results : The R, G and B values which were converted by X, Y and Z values had high linearity as a high level of R-square (R: 0.969, G: 0.996, and B: 0.992). Moreover, we confirmed that it was possible to quantitatively analyzed the change in skin color by cupping using R, G, B, $L^*$, $a^*$, $b^*$, E.I., and M.I. Conclusions : Therefore, we proposed the new analytical technique for objectifying the oriental medical diagnostic method using cupping and optical sensing technique.

HMI 기능 시뮬레이션 기반 개인용 휴대전자제품의 가상시작 (Virtual Prototyping of Portable Consumer Electronic Products Based on HMI Functional Simulation)

  • 박형준;배채열;문희철;이관행
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2005년도 춘계공동학술대회 발표논문
    • /
    • pp.854-861
    • /
    • 2005
  • The functional behavior of a portable consumer electronic (PCE) product is nearly all expressed with human-machine interaction (HMI) tasks. Although physical prototyping and computer aided design (CAD) software can show the appearance of the product, they cannot properly reflect its functional behavior. In this paper, we propose a virtual prototyping (VP) system that incorporates virtual reality and HMI functional simulation in order to enables users to capture not only the realistic look of a PCE product but also its functional behavior. We obtain geometric part models of the product and their assembly and kinematics information with the help of CAD and reverse engineering tools, and visualize them with various display tools. We adopt state transition methodology to capture the HMI functional behavior of the product into a state transition chart, which is later used to construct a finite state machine (FSM) for the functional simulation of the product. The FSM plays an important role to control the transition between states of the product. The proposed VP system receives input events such as mouse clicks on buttons and switches of the virtual prototype model, and it reacts to the events based on the FSM by activating associated activities. The VP system provides the realistic visualization of the product and the vivid simulation of its functional behavior. It can easily allow users to perform functional evaluation and usability testing. Moreover, it can greatly reduce communication errors occurring in a typical product development process. A case study about VP of an MP3 player is given to show the usefulness of the proposed VP system.

  • PDF