• Title/Summary/Keyword: Evacuation Characteristics

Search Result 209, Processing Time 0.029 seconds

An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101 (NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석)

  • Cho, Ji-Eun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.331-337
    • /
    • 2020
  • The study analyzes the appropriate number of people per a household by applying an evacuation simulation to a 27-floor apartment in accordance with the NFPA 101 standard. The results of the analysis are as follows. First, if there are three people residing in each household, there would be 156 households in total, of which 85.25% were evacuated within 5 minutes. Second, 208 households with 4 residents were evacuated within 5 minutes. Third, if there are five people residing in each household, there would be a total of 260 households and 71.92% of residents were evacuated within 5 minutes. Lastly, 62.82% of the 312 households, each consisting of 6 people, were evacuated within 5 minutes. Measures to reduce evacuation time include determining the width of the stairs according to the number of people indoors, the number of floors in the building, the slope of stairs, and the users' characteristics, the design reflecting the ventilation conditions of the stairs, the installment of outdoor evacuation stairs, two-way stairs, evacuation lift, and the installation of an evacuation safety zone for people to evacuate outside of the building in the middle floors. In addition, measures, such as the mandatory installation of automatic emergency door open-close device to the rooftop, are required to facilitate rooftop evacuation.

A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses (공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구)

  • Kim, Hak Kyung;Choi, Doo Chan;Lee, Doo Hee;Hwang, Hyun Soo;Kim, Hee Moon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.38-50
    • /
    • 2022
  • Purpose: The goal of this research is to create a numerical analytic database that may assist fire prevention managers and building officials in prioritizing items that need to be addressed in order to improve evacuation safety performance while working within a constrained budget and time frame. Method: It was carried out utilizing the CFD Tool, a quantitative evaluation approach, to assess evacuation safety. One direct staircase-type apartment houses and one corridor-type apartment were chosen to make it. Result: In the fire compartment category, Apartment A's evacuation time was around 130 percent longer than that of sprinkler facilities. Conclusion: Fire prevention managers and building officials feel that starting with a single level and implementing "dwelling unit separations" will increase evacuation safety, and that maintaining fire compartments and sprinkler systems at all times will be effective. Because of the limited characteristics of smoke propagation in corridor-type apartments compared to direct staircase-type flats, it is thought that fire extinguishing equipment should be addressed.

Demonstration of Disaster Information and Evacuation Support Model for the Safety Vulnerable Groups (안전취약계층을 위한 재난정보 및 대피지원 모델 실증)

  • Son, Min Ho;Kweon, Il Ryong;Jung, Tae Ho;Lee, Han Jun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.3
    • /
    • pp.465-486
    • /
    • 2021
  • Purpose: Since most disaster information systems are centered on non-disabled people, the reality is that there is a lack of disaster information delivery systems for the vulnerable, such as the disabled, the elderly, and children, who are relatively vulnerable to disasters. The purpose of the service is to improve the safety of the disabled and the elderly by eliminating blind spots of informatization and establishing customized disaster information services to respond to disasters through IoT-based integrated control technology. Method: The model at the core of this study is the disaster alert propagation model and evacuation support model, and it shall be developed by reflecting the behavioral characteristics of the disabled and the elderly in the event of a disaster. The disaster alert propagation model spreads disaster situations collected using IoT technology, and the evacuation support model uses geomagnetic field-based measuring technology to identify the user's indoor location and help the disabled and the elderly evacuate safely. Results: Demonstration model demonstration resulted in an efficient qualitative evaluation of indoor location accuracy, such as the suitability of evacuation route guidance and satisfaction of services from the user's perspective. Conclusion: Disaster information and evacuation support services were established for the safety vulnerable groups of mobile app for model verification. The disaster situation was demonstrated through experts in the related fields and the disabled by limiting it to the fire situation. It was evaluated as "satisfaction" in the adequacy of disaster information delivery and evacuation support, and its functional satisfaction and user UI were evaluated as "normal" due to the nature of the pilot model. Through this, the disaster information and evacuation support services presented in this study were evaluated to support the safety vulnerable groups to a faster disaster evacuation without missing the golden time of disaster evacuation.

A Study of Heat St Smoke Evacuation Characteristics by the Changing of Operational Method of Tunnel Fan Shaft Ventilation System for Fire on Subway Train Vehicle (지하철 화재시 본선터널 환기시스템에 따른 열 및 연기배출특성)

  • 이동호;유지오
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.62-69
    • /
    • 2003
  • The smoke control system in subway platform is not only using for smoke exhaust facility but also using ventilation system. For this reason, smoke vent effectiveness is depending on its position, ventilating volume capacity and the vent method. In this study, the passenger's evacuation time was calculated for the case of fire on sloped subway train vehicle in subway platform. In order to recommend the mechanical smoke exhaust operation mode, SES (Subway Environmental Simulation) was used to predict the airflow of the inlet and outlet tunnel for the subway station. Fire dynamics Simulator(FDS) was used the SES's velocity boundary conditions to calculate the smoke density and temperature under the condition of fire on stopped subway train vehicle at the platform. We compared smoke density and temperature distributions for each 6 types of smoke exhaust systems to clarify the characteristics of smoke and hot air exhaust effectiveness from the result of fire simulation.

Steady and Unsteady Operating Characteristics of Supersonic Exhaust Diffuser for Altitude Simulation (고도모사용 초음속디퓨져의 정상 및 천이작동특성)

  • Park, Byung-Hoon;Ki, Wan-Do;Lim, Ji-Hwan;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.344-352
    • /
    • 2006
  • Evacuation performance, starting transient, and plume blowback at diffuser breakdown of a straight cylindrical supersonic exhaust diffuser with no externally supplied secondary flow are investigated. Pressure records in the transitional periods are measured by a small-scale cold-gas simulator. Flow-fields evolving in the diffuser-type ejector are solved by preconditioned Favre-averaged Navier-Stokes equations with a low-Reynolds number $k-{\varepsilon}$ turbulence model edited for turbulence compressibility effects. The present RANS method is properly validated with measured static wall pressure distributions and evacuation level at steady operation as well as the pressure records during the transition regime.

  • PDF

Optimization for Ventilation Capacity of Large Enclosure Considering Fire Load (화재하중을 고려한 대공간 제배연 용량 최적화 연구)

  • Ahn, Chan-Sol;Kim, A-Ram
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.478-481
    • /
    • 2011
  • This study is intended to evaluate and optimize the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard, which has been currently applied to the buildings in Korea. Using the heat release per unit weight of the combustibles, a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out at the several different shopping malls. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

A Study on Network Analysis of Flooded Roads (홍수범람에 따른 도로침수 네트워크 분석에 관한 연구)

  • Kim, Kyong-Hoon;Kim, Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.241-242
    • /
    • 2016
  • Recently, the interests in safety and prevention from disaster are increasing. In particular, lifeline networks such as water line and sewerage, electricity, gas, and road would be damaged from a disaster. If the lifeline networks do not work in normal, national public service will not properly function. Researches in social network analysis have been conducted for analyzing the interdependency between individuals since 1970s. These network analysis are utilized to investigate a spread of information and disease. However, it is hard to discover the analyzed cases including characteristics of nodes of networks in the area of transportation and disaster. Therefore, this study conducts network analysis of flooded road with flooding scenarios, investigates safe evacuation routes in flooded road network, and suggests efficient approaches for preventing damages from a flooding.

  • PDF

Study on Heat and Smoke Exhaust Characteristics for Different Operating Modes of Platform and Tunnel Fans during a Passenger Train Fire (전동차 화재시 승강장 및 터널 환기실의 팬 작동에 따른 열 및 연기 배출 특성 연구)

  • Chang, Hee-Chul;Kim, Tae-Kuk;Son, Bong-Sei;Park, Won-Hee
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • This study is focused on the numerical predictions of heat and smoke exhaust characteristics in an underground subway station stopping a fire train. Various ventilation operating modes with the fan equipped the platform and tunnels are considered. Distributions of temperature, carbon monoxide and visibility at a height of 1.7 m(breath height) above the platform are analysed for different ventilation fan operation mode. The numerical results show that smoke and heat is rapidly removed through tunnel by operating the tunnels fans. We suggested that during evacuation of passengers is not completed, the ventilation system in the platform is activated. After completion of passenger evacuation tunnel fans are activated but the fans in the platform are stopped.

Cause Analysis and Improvement Suggestion for Flood Accident in Dorimcheon - Focused on the Tripping and Isolation Accidents (도림천에서 발생한 고립 및 실족사고의 원인분석을 통한 개선방안 도출에 관한 연구)

  • Lee, Kyung-Su;Jeon, Jong-Hyeong;Kim, Tai-Hoon;Kim, Hyunju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.25-36
    • /
    • 2021
  • This study analyzed the causes of flood accidents, such as isolation and lost footing accidents in Dorimcheon, to provide legal and institutional improvements. For cause analysis, Field Investigation, Stakeholder Interview, Report, manual, Law et al. Review, Analysis of water level change characteristics, automatic alarm issuance standard level analysis, and evacuation time according to river control were evaluated. Dorimcheon has the characteristics of a typical urban river, which is disadvantageous in terms of water control. In addition, the risk of flood accidents is high because the section where fatal accidents occur forms sharply curved channels. Tripping and isolation accidents occur in the floodplain watch and evacuation stage, which is the stage before the flood watch and warning is issued. Because floodplain evacuation is issued only when the water level rises to the floodplain, an immediate response according to the rainfall forecast is essential. Furthermore, considering that the rate of water level rise is up to 2.62 cm/min in Sillimgyo 3 and Gwanakdorimgyo, sufficient evacuation time is not secured after the floodplain watch is issued. Considering that fatal accidents occurred 0.46 m below the standard water level for the flood watch, complete control is very important, such as blocking the entry of rivers to prevent accidents. Based on these results, four improvement measures were suggested, and it is expected to contribute to the prevention of Tripping and Isolation Accidents occurring in rivers.