• Title/Summary/Keyword: Estimation of the adequacy

Search Result 77, Processing Time 0.024 seconds

A study of Determination of Frost penetration Depth in incheon Area (인천지역의 동결깊이산정에 관한 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.5-6
    • /
    • 2015
  • Recently, freezing index of frost penetration depth estimation used in Korea is applied according to the standard, published by MOLIT in 2003. However, it is difficult to consider can not be determined to standard reflects weather conditions in accordance with the current climate warming or abnormally high temperature. Also the temperature should be considered local variables because heavy local gap. Therefore, this study is through the freezing index presented in MOLIT's code by calculating the frost penetration depth determining whether the adequacy and conducted a study to apply in the field. As a result, when the Elevation 100m to standard in Incheon frost penetration depth is found to be 50.8cm.

  • PDF

Nutritional Status and Dietary Quality in the Low-income Elderly Residing at Home or in Health Care Facilities (사회복지시설과 자택거주 저소득층 노인의 영양섭취상태와 식사의 질 평가)

  • Kwak, Kyung-Soon;Bae, Yun-Jung;Kim, Mi-Hyun
    • Journal of the Korean Dietetic Association
    • /
    • v.14 no.4
    • /
    • pp.337-350
    • /
    • 2008
  • The principal objective of this study was to assess the nutritional status and dietary quality in low-income elderly individuals residing at home (LH) or in health care facilities (LHCF) with dietitian. This study was conducted via anthropometric measurements, questionnaire interviews, and dietary surveys using a 24 hr recall method with 120 low-income elderly individuals (LHCF=46, LH=74). The average ages of the LH and LHCF group were 76.3 years and 78.6 years, respectively. The LH group evidenced a significantly higher frequency of skipping meals than the LHCF group. The average energy intakes of the LHCF and LH group were 1921.0 kcal and 1443.9 kcal, with a significant difference (p<0.001). Most of the nutrient intake and intake rates for recommended intake were significantly higher among the LHCF group as compared with the LH group. The LHCF group showed significantly higher values for the nutrient adequacy ratio (NAR), the mean adequacy ratio (MAR), nutrient density (ND), and the index of nutritional quality (INQ) by dietary qualitative estimation than in the LH group. The Korean diet diversity scores (KDDS) were 3.66 for LH group and 4.93 for the LHCF group, thus were significantly higher in the LHCF group than in the LH group. The results of the present study demonstrate that the LH group appeared to experience more dietary problems than the LHCF group. It was suggested that nutritional education is needed for low-income elderly individuals living at home, in order for them to learn proper dietary management. This can be achieved via educational programs in social welfare institutions, incentives toward employment as a dietitian, and implementation of community-based support.

  • PDF

Dietary Quality Estimation of Military Foodservice Menu (군 급식 제공 메뉴 분석에 의한 식사의 질 평가)

  • Baek, Seung-Hee;Kim, Soo-Yeon
    • The Korean Journal of Food And Nutrition
    • /
    • v.23 no.4
    • /
    • pp.641-648
    • /
    • 2010
  • This study attempted to estimate the dietary quality and the food diversity by analyzing the military foodservice menu. To evaluate the dietary quality, an analysis of NAR(Nutrient Adequacy Ratio) and MAR(Mean Adequacy Ratio) were carried out. DDS(Dietary Diversity Score), DVS(Dietary Variety Score) and DMGFV(Dairy Product, Meat, Grain, Fruit, Vegetable group) were used for assessment of food diversity. A Can-pro 3.0 and an excel were used for dietary data analysis and SPSS 12.0 program was used for statistical analysis. The results were as follows. The NAR of the 9 nutrients was above the RDAs and MAR was $1.71{\pm}0.19$. For 19 days(61.3%), DDS was 5 and for 12 days(38.7%), DDS was 4. The average of DDS was $4.6{\pm}0.25$. The Fruit & vegetable groups were not often served compared to other groups and especially fresh fruit were not given enough. The average of DVS and DVSS were $22.48{\pm}0.61$ and $29.26{\pm}0.66$ each. The most frequent food pattern was 'DMGFV=11111' which was served for 19 days(61.3%) and second frequent pattern 'DMGFV=11101' was served for 12 days(38.7%). DDS was significantly associated with Vit. C intake and DVS and DVSS was significantly related to Vit. $B_1$ and Vit. $B_2$ intakes. The MAR was significantly correlated with only DVSS. It could be interpreted that DVSS is a useful parameter for evaluating nutrient intakes as previous studies verified. Based on these findings, it can be said that military foodservice was provided with adequate nutrition and diversity. Menu was well composed of various foods which met the nutrition standards, but should provide more fresh fruits for adequate provision of vitamins and minerals.

Bayesian Curve-Fitting in Semiparametric Small Area Models with Measurement Errors

  • Hwang, Jinseub;Kim, Dal Ho
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.4
    • /
    • pp.349-359
    • /
    • 2015
  • We study a semiparametric Bayesian approach to small area estimation under a nested error linear regression model with area level covariate subject to measurement error. Consideration is given to radial basis functions for the regression spline and knots on a grid of equally spaced sample quantiles of covariate with measurement errors in the nested error linear regression model setup. We conduct a hierarchical Bayesian structural measurement error model for small areas and prove the propriety of the joint posterior based on a given hierarchical Bayesian framework since some priors are defined non-informative improper priors that uses Markov Chain Monte Carlo methods to fit it. Our methodology is illustrated using numerical examples to compare possible models based on model adequacy criteria; in addition, analysis is conducted based on real data.

Analysis of the Adequacy of Nurse Staffing Level through the Estimation of Nursing Activity Hours and Implementation of Focus Group Interviews in a Tertiary Hospital: Using a Mixed-Method Design (일 상급종합병원 병동간호사의 업무량 측정 및 간호사 배치수준의 적절성 연구: 혼합연구 설계 적용)

  • Kim, Hyun-Joo;Lee, Sun-Hee;Lee, Jai-Jung;Seong, Sun-Suk;Yang, Hee;Lee, Hyang-Yuol
    • Journal of Korean Academy of Nursing
    • /
    • v.54 no.2
    • /
    • pp.237-249
    • /
    • 2024
  • Purpose: This study aimed to examine the adequacy of current nurse staffing levels by identifying nursing activities and workload. Methods: The study used a mixed-method design. A nursing activity survey was conducted using the work sampling method over 2 working days with 119 general ward nurses. A focus group interview was conducted with 12 nurses. Quantitative and qualitative data were analyzed using SPSS 20.0 and content analysis, respectively. Results: The most amount of time was spent on medication (in direct nursing) and electronic medical record documentation (in indirect nursing). The appropriate nurse-to-patient ratio is 1:7.7 for the day shift, 1:9.0 for the evening shift, and 1:11.9 for the night shift. However, the current nurse-to-patient ratio is 1:9.4, 1:11.0, and 1:13.8 for the day, evening, and night shifts, respectively. Therefore, the current nurse staffing level is insufficient for the workload. In the focus group interview, the main reasons cited for being unable to complete tasks within working hours were communication and coordination, and the nursing electronic medical record. The essential nursing activities of basic nursing and emotional support were overlooked owing to a heavy workload. Therefore, an adequate nurse staffing level should be higher than the measured quantitative workload. Conclusion: These results suggest the general wards of tertiary hospitals should evaluate the adequacy of their current nurse staffing and allocate sufficient nurses to improve patient safety and nursing care quality.

A Study on Correlation between Compressive Strength and Rebound Hardness of Urban Underground Structures (도시철도 지하구조물 압축강도와 반발경도의 상관관계에 관한 연구)

  • Choi, Jung-Youl;Lee, Soo-Jae;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.655-661
    • /
    • 2020
  • In this study, the correlation between concrete core compressive strength and rebound hardness of urban railway underground structures was analyzed. The equations for the range of rebound hardness were derived and compared with the measured concrete core strengths for each range of rebound hardness to confirm the adequacy of the estimated compressive strength. As the result, the linear regression analysis results of the average compressive strength by the Gaussian probability density function (representative compressive strength estimation formula) and the estimation formula by the rebound hardness range were founded to match well within 3% of the experimental concrete core compressive strength test results. Therefore, the stochastic statistical analysis using the rebound hardness measurement results suggested in this study could be help to secure the confidence level of the correlation between the rebound hardness and the concrete compressive strength which are relatively large deviation according to the estimation equations.

Discrete Event Simulation based Equipment Combination Optimization Method - based on construction equipment performance estimation of the Construction Standard Production Rate - (이산형 이벤트 시뮬레이션 기반 최적의 건설장비 조합 도출 방법 제시 - 표준품셈 건설기계 시공능력 산식을 기반으로 -)

  • Ko, Yongho;Ngov, Kheang;Noh, Jaeyun;Kim, Yujin;Han, Seungwoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.6
    • /
    • pp.21-29
    • /
    • 2022
  • Productivity estimation of construction operations is crucial to successful project delivery. Especially in the preconstruction phase, the adequacy and effectiveness of plans directly affect the actual performance of operations. Currently, productivity estimation is conducted by referring to existing references such as the Construction Standard Production Rate. However, it is difficult to promptly apply changing conditions of operations when using such references. Moreover, it is difficult to deduce the optimal combination of construction machinery for the given condition. This paper presents a simple simulation model that can be used to generate productivity data that considers site conditions and construction equipment combination. The suggested method is expected to be used as a decision making assisting tool for practitioners who rely on estimations using the Construction Standard Production Rate when establishing construction plans using heavy machinery such as backhoes, loaders and dumptrucks.

An Empirical Study on Estimation model of Suhyup Bank's Risk-Weighted Assets, related Basel III (Basel III 관련 수협은행의 위험가중자산 추정모형에 관한 실증연구)

  • Choi, Kye-Jung;Kim, Byung-Ho
    • The Journal of Fisheries Business Administration
    • /
    • v.47 no.1
    • /
    • pp.87-100
    • /
    • 2016
  • Suhyup Bank became to be subject to regulation of capital ratio by Basel III which was introduced in order to enhance stability of the financial institution. Accordingly, Suhyup Bank will require recapitalization. It is important to estimate the risk-weighted assets in calculating of Suhyup Bank's recapitalization scale. Therefor, this study aimed to present a scientific model as estimated the risk-weighted assets. Risk-weighted assets are calculated by applying different risk weights for loans, may have a certain relationship with the loans. Results show that the risk-weighted assets is affected by the previous year's risk-weighted assets and influenced the increase in loans during the year. Since the required basic capital adequacy ratio was specified, the risk-weighted assets should be predicted reasonably. Accordingly, on this study it was tried to derive the accounting equation to predict the risk-weighted assets based on management data of a bank since introduction of Basel III. As the risk-weighted assets were weighted differently according to the type of loans, if the accounting equation is derived by using the type of loans, then it would be helpful for the risk management of banks in the long-term. According to this, the increase of loan would be predicted on the basis of past management performance of Suhyup Bank, and for this reason, the future risk-weighted assets of Suhyup Bank were predicted. The result of this study was showed that 98.3% of risk-weighted assets of the previous year, 62.4% of the secured loan changes and 95.1% of the credit loan changes affected risk-weighted assets.

FAIR-Based Loss Measurement Caused by Personal Information Breach of a Company (FAIR를 통한 개인정보 유출에 따른 기업의 손해금액 산출에 대한 연구)

  • Kim, Jeong-Gyu;Lee, Kyung-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.1
    • /
    • pp.129-145
    • /
    • 2017
  • This study proposes a methodology to estimate the financial damages by personal information breach of a company and to analyse risk systematically through a case study of a company which experiences private information breach. Using FAIR(Factor Analysis of Information Risk) model, estimate the loss amount and to analyse risk objectively of a company by personal information breach. This study estimates adequacy and importance of corresponding factors applying AHP(Analytic Hierarchy Process) on each factors for assessing loss amount. By adopting proposed methodology in this study, the person in charge of actual work can assess and prove the loss amount though the latest risk estimation methodology. In addition, the person in charge can select the proper parameters for the corresponding company and can obtain the objective quantitative estimation. Hence it can be reported to the management by accurately assessing loss amount caused by personal information breach.

Critical Length Estimation of Counterpoise Subjected to Lightning Stroke Currents

  • Lee, Bok-Hee;Yoo, Yang-Woo;Kim, Jong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.106-113
    • /
    • 2011
  • The conventional grounding impedance of a counterpoise is calculated as a function of the length of the counterpoise by use of the distributed parameter circuit model with an application of the EMTP(Electromagnetic Transient Program). The adequacy of the distributed parameter circuit model is examined and verified by comparison of the simulated and the measured results. The conventional grounding impedance of the counterpoise is analyzed for the first short stroke and subsequent short stroke currents. As a result, the simulated results show that the minimum conventional grounding impedance gives at a specified length of the counterpoise. The shorter the time taken to reach the peak of injected currents, the shorter the length of the counterpoise having the minimum conventional grounding impedance. We also present the critical lengths of the counterpoise for short stroke currents as a function of soil resistivity. Based on these results, it is necessary to compute the length of the counterpoise in a specified soil resistivity which satisfies both the low conventional grounding impedance requirement whilst also providing a suitable ground resistance in order to obtain an economical design and installation of the counterpoise.