• 제목/요약/키워드: Esthetic eye

검색결과 14건 처리시간 0.024초

상악골, 하악골 및 이부의 외과적 동시 이동술 (SIMULTANEOUS SURGICAL REPOSITIONING OF THE MAXILLA, MANDIBLE, AND CHIN)

  • 이재휘;이호준;황병남;이정근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제18권2호
    • /
    • pp.184-199
    • /
    • 1996
  • The challenges to achieve three dimensional facial proportionality and occusal stability in many patients with complex dentofacial deformity have been met by the development and use of the maxilla, mandible, and chin surgery techniques in combination with efficient orthodontic treatment. There is a clinical, biological, and biomechanical foundation for simultaneous surgical repositioning of the maxilla, mandible, and chin in a significant proportion of adult and adolescent patients. A combination of the surgical and orthodontic approach may provide increased treatment efficiencies and optimal esthetic results. Art and science to determine the treatment objectives, specifically, the desired soft tissue changes are firstly established by using the clinician's "esthetic sense" of the facial beauty and proportion aided to a few cephalometric guidelines. In this sense, the dependence on the clinician's "esthetic eye" by Dr. Bell is more important in analyzing the facial proportion than the satisfaction of rigid cephalometric norms. The purpose of this article was to elucidate the indication for simultaneous surgical repositioning of the maxilla, mandible, and chin, and to describe the clinical cephalometric analysis for orthognathic surgery. Representative 6 case reports were presented and discussed to illustrate the esthetic, orthodontic, and surgical treatment objectives with long-term follow-up.

  • PDF

총체적 심미 악안면 성형수술 : I. 상하악 악교정 수술을 위한 새로운 연조직 심미기준선 (TOTAL ESTHETIC ORTHOGNATHIC SURGERY : I. NEW ESTHETIC LINES AND INTER-ESTHETIC LINE ANGLE)

  • 정필훈;송민석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권4호
    • /
    • pp.329-337
    • /
    • 1993
  • Improvement of orthognathic surgical techniques make it possible to design esthetic surgical correction for total esthetic face. In order to find the esthetic line which guide esthetic surgical correction in patients of orthognathic surgery, cephalometric soft tissue analysis of esthetic faces were performed. In esthetic Korean young adults, 25 males and 25 females who were within 1 S.D. of E-line, ANB, P/A facial height ratio, were analyzed in natural position keeping their face eye level. 1. Sn position is constant in males and females. The Sn-N'-N' Vertical plane angle is $5.3^{\circ}$ in both sexes. Sn is positioned in front of 5 mm in female 7 mm in male from the N' vertical plane. 2. The Sn-Ls line make constant angle to horizontal plane with $72.5^{\circ}$ in both sexes, which is called "upper esthetic line". The Ls-Pg' line makes constant angle to $72.4^{\circ}$ (range $72.2^{\circ}$ in female to $72.6^{\circ}$ in male), which is called "lower esthetic line". 3. When inter-esthetic line angle (the Sn-Ls line to Ls-Pg' line) has $144.9^{\circ}$, lower third face has esthetic upper and lower lip. 4. In treatment planning, Sn is first corrected in proper position, and then upper and lower esthetic line are established with the angle of 144.9. The maxilla is moved to tangent Ls to the upper esthetic line, and mandible is moved to tangent Li and Pg' to the lower esthetic line, according to the "y"-shaped esthetic lines, then lower third face showes esthetics.

  • PDF

Review on Historical Assessment and Perception of Dziga Vertov

  • Jeon, Pyoung-Kuk
    • International Journal of Contents
    • /
    • 제4권4호
    • /
    • pp.24-29
    • /
    • 2008
  • In 1920s, Soviet silent films enjoyed unprecedentedly great prosperity throughout world film history. Particularly, Dziga Vertov could develop 'montage' in collaboration with Sergei Eisenstein and thereby could work as the engines behind development and leap of Soviet films toward 'new concepts' of 'new films' worldwide. However, Vertov's original reputations - the best film theorist and avant-gardist as well as great cineaste in his contemporary age - have been misunderstood or underestimated, so that he has been still misestimated or distorted as radical formalist and documentary propagandist. In regard to these points, this study aims to take Gilles Deleuze's modal esthetic approaches to further considering and historically re-highlighting D. Vertov's film theories that are based on the principle of 'film-reality' and the concept of 'Life As It Is' according to 'kino-eye' method and 'interval' theory as a part of futurism and constructivism breaking down any attribute of traditional narrative films.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.219-225
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

ShadepilotTM을 이용한 색조 선택 (Clinical Color Match using ShadepilotTM)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.131-137
    • /
    • 2007
  • The ability of a dentist to select and communicate an acceptable shade match to a dental laboratory may be the most important factor in esthetic restorative dentistry. However, shade matching is a very complex situation. In this study, an attempt was made to compare and evaluate the conventional visual assessment and colorimetric analysis in clinical shade matching. 20 patients were selected and their maxillary central incisors shade were measured by Vita classic shade guide, using $Shadepilot^{TM}$ and ShadeEye $NCC^{(R)}$. The results indicate that there is much variation in the shade selection by visual and instrumental methods.

색조 선택 시스템을 이용한 shade guide의 색조 분석 (Evaluation of shade guide using digital shade analysis system)

  • 이승택;이종혁;신수연
    • 대한치과보철학회지
    • /
    • 제47권1호
    • /
    • pp.1-11
    • /
    • 2009
  • 연구목적: 심미 수복을 위한 색상 결정 방법으로는 색견본 (shade guide)과 치아를 눈으로 직접 비교하는 기존의 비색법과 최근 소개되기 시작한 색상 측정용 기기를 사용하는 방법이 있다. 비색법은 치과의사들과 기공사들 간의 색조 선택에 일관성이 결여되어 있는 등 많은 문제점이 지적되고 있지만 아직도 이러한 방법에 의한 색상 결정과 결정 색상에 대한 표현 방식이 임상 치의학에 적용되고 있다. 본 연구의 목적은 진료실과 기공소에서 사용하고 있는 색견본이 같은 값을 가지는지 ShadeEye - $NCC^{(R)}$ dental chroma meter (Shofu Inc., Kyoto, Japan)로 확인하고 또한 이 측정 기기의 두 가지 모드가 동일한 shade tab을 같은 값으로 인식하는지 확인하고자 하였다. 연구재료 및 방법: 첫 번째 실험에서는 모두 8개의 Vita Lumin Vacuum shade guide (Vident Inc., California, USA)를 모아 그 중 A1과 B1 shade tab을 각각 5회씩 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 하였고 두 번째 실험에서는 치과 진료실과 기공소에서 실제 사용하고 있는 Vita Lumin Vacuum shade guide를 각각 12개씩 모아 역시 A1과 B1 shade tab을 색상 측정용 기기인 ShadeEye-$NCC^{(R)}$의 tooth mode와 porcelain mode로 나누어 색조 분석을 실시하였다. 결과: 첫 실험에서 8개의 색견본의 A1과 B1의 5회씩 측정에서 두 가지 mode에서 모두 채도 (shade), 명도 (value), 색상 (hue)에서 유의한 차이를 보였다(P<.05). 두 번째 실험에서는 진료실에서 사용하는 색견본과 기공소에서 사용하는 색견본 사이에는 통계적으로 유의한 차이를 보이지 않았으나, A1의 porcelain mode 에서 채도가 유의한 차이를 보여 (P<.05), 같은 shade tab이라 할지라도 채도에서 차이가 날 수 있음을 보였다. 결론: ShadeEye-$NCC^{(R)}$의 mode에 따라 동일한shade tab을 다른 값으로 인식하는 것으로 나타나 진료실과 기공소 간에 동일한 mode로 사용하는 것이 필요할 것으로 사료된다.

열가압성형도재 코어의 가시광선 투과율에 관한 연구 (A study on the visible wave of transmittance pressable ceramic core)

  • 정인호;이상덕;남상용
    • 대한치과기공학회지
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the transmittance differences of pressable ceramic core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 2 groups (0.6mm, 0.8mm) which have each 3 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness(0.6mm, 0.8mm) and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown. Also, When making all ceramic core with dead pulp (nervous treatment tooth) when used as a restorative esthetic think is more efficient to improve.

Radiation Therapy for Primary Eyelid Cancers in Tunisia

  • Belaid, A;Nasr, C;Benna, M;Cherif, A;Jmour, O;Bouguila, H;Benna, F
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권7호
    • /
    • pp.3643-3646
    • /
    • 2016
  • Management of eyelid cancers is based on surgery and/or radiotherapy (RT). The treatment objective is to control tumors with acceptable functional and esthetic outcomes. The aim of this study was to evaluate the results of radiation therapy in management of epithelial eyelid cancers, reviewing retrospectively the clinical records of patients treated in our institution from January 1989 to December 2013. We focused on clinical and histological features, treatment characteristics, tolerance and disease control. One hundred and eight patients (62 men and 46 women) were enrolled, with a mean age of 61 years [ranges 15-87]. The most frequent tumor location was the inner canthus (42.6%). Median tumor size was 21 mm [ranges 4-70]. Histological type was basal cell carcinoma in 88 cases (81.5%), squamous cell carcinoma in 16 (14.8%) and sebaceous carcinoma in 4 (3.7%). Radiation therapy was exclusive in 67 cases (62%) and post-operative for positive or close margins in the remaining cases. Kilovoltage external beam radiotherapy (KVRT) was used in 63 patients (58.3%) and low-dose-rate interstitial brachytherapy in 37 (34.3%). Eight (7.4%) were treated with cobalt or with a combination of KVRT-cobalt, KVRT-electron beams, KVRT-brachytherapy or cobalt-electron beams. The total delivered radiation doses were 70 Gy (2 Gy/fraction) in 62 patients (57.4%), 66 Gy (2 Gy/fraction) in 37 (34.3%) and 61.2 Gy (3.4Gy/fraction) in 9 (8.3%). After a median follow-up of 64 months, we noted 10 cases of local recurrences(9.2%): 7 after exclusive and 3 after post-operative RT. No local recurrence occurred in patients treated with brachytherapy. Actuarial 5-year local recurrence-free rate, disease-free survival and overall survival were respectively 90%, 90% and 97%. T-stage was found to be a significant factor for recurrence (p=0.047). All acute radiation-related reactions were scored grade I or II. Delayed effects were eye watering in 24 cases (22.2%), eye dryness in 19 (17.6%), unilateral cataract in 7 (6.4%) and ectropion in 4 (3.7%). Radiation therapy and especially brachytherapy is an efficient treatment of eyelid cancers, allowing eye conservation and functional preservation with good local control rates and acceptable toxicity.

ShadeEye$^{(R)}$ NCC system을 이용한 Vita CAD/CAM Ceramic Block의 크기에 따른 색조 일치성 비교연구 (Comparative Study of Color Correspondence According to Size of Vita CAD/CAM Ceramic Block Using ShadeEye-Ncc$^{(R)}$ System)

  • 김재홍;김혜영;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제33권3호
    • /
    • pp.203-210
    • /
    • 2011
  • Purpose: The purpose of this study was to compare color correspondence of different sizes of Vita Mark II$^{(R)}$ and TriLuxe$^{(R)}$ Feldspar blocks. Methods: The three commercially available shades(1M2, 2M2, 3M2) of Mark II & TriLuxe blocks for the CEREC$^{(R)}$ CAD/CAM system were examined. For each of three colors, three different sizes were tested, 5 blocks each. The measurements were made using a spectrophotometer equipped with an integrating sphere using the CIE $L^*$, $a^*$, $b^*$ colorimetric system. Results: The $L^*$, $a^*$, $b^*$ value of Vita Mark II$^{(R)}$ ceramic block showed significantly higher than TriLuxe$^{(R)}$ ceramic block(p<0.05). In comparing the Vita Mark II$^{(R)}$ specimen of the three different shade, color differences between materials(${\Delta}E^*$) showed the lowest value of 2.09, and the highest was 2.24. ${\Delta}E^*$ values of the materials of Vita Mark II$^{(R)}$ were higher than 2. As the size of ceramic block differed, the color correspondence of Vita Mark II$^{(R)}$ showed statistically significant difference but, this result is clinically acceptable. Conclusion: All the different sizes of the different shades of Vita TriLuxe$^{(R)}$ blocks for the CEREC$^{(R)}$ system showed the high degree of color correspondence necessary in industrially prefabricated CAD/CAM blocks. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

Hinge Axis Point에 관한 연구 (A Study of the Hinge Axis Point)

  • 정금태
    • 대한치과보철학회지
    • /
    • 제22권1호
    • /
    • pp.72-78
    • /
    • 1984
  • The notion that the axis of the shaft of the articulator must coincide the patient's mandibular transverse axis tells us the importance of locating the axis precisely. When using kinematic axis to transfer a cast to an articulator, the anatomic asymmetry of the contralateral points will result in certain distortion when the axis transferred to an articulator where the mechanical axis produces symmetry. In this study, after locating the true hinge axis point with Denar hinge axis locator, the discrepancies between true hinge axis point and arbitrary hinge axis point that was 13mm anterior from the posterior margin of center of trangus to the outer canthus of eye were measured. And the discrepancies between left and right true hinge axis point in the superoinferior and anteroposterior directions were measured. For this study, 20 dental students who have no missing teeth and no difficulties of mandibular movement were selected. Upper and lower cast of subjects were mounted on Denar Mark II articulator uisng Denar Slidematic face-bow and centric relation record for the measurement of discrepancies between left and right true hinge axis points. The results obtained as follows. 1. The mean distance from the arbitrary hinge axis point to the true hinge axis point was as follows. Right: horizontal distance; 1.99mm, vertical distance; 2.12mm, linear distance; 3.36 mm. Left: horizontal distance; 1.39mm, vertical distance; 2.06mm, linear distance; 2.09mm. Total: horizontal distance; 1.69mm, vertical distance; 2.09mm linear distance; 3.06 mm. 2. The 87.5% of true hinge axis points were within 5mm of the arbitrary hinge axis point. 3. The mean discrepancies between the right and left hinge axis point were 2.92mm in superoinferior direction and 4.74mm in anteroposterior direction. 4. When transferring the axis to the articulator, anatomic asymmetry between right: and left axis point produces in dislocation of cast on the articulator, and undesirable shift in esthetic tooth position will be resulted.

  • PDF