• Title/Summary/Keyword: Escape Room

Search Result 44, Processing Time 0.035 seconds

A Case Study on the Passengers' Evacuation Times according to the Fire Smoke Density On a Ship (선박 화재 시 선내의 연기농도가 승객의 피난시간에 미치는 영향)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, You-Jin;Youn, Jeong-Ha;Lee, Sang-Il;Hong, Won-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.336-343
    • /
    • 2009
  • Because ships are very isolated and independent objects when sailing on the ocean, if a fire and smoke occurs, nobody can be sure to escape safely from ship at the moment. On the focus of the relationship between the sight transmissivity by fire smoke density and the life safety, this study performs simulations and experiments, respectively. To evaluate the theoretical evacuation time, CFAST software which is known as a 2 zone model analysis tool is used, and the result is 54 seconds from ECR(Engine Control Room) exit to upper deck exit and 34 seconds from bosun store to upper deck exit. And totally 12 types of experiments are performed with other 10 persons per experiment. As the result, it is cleared that the low sight transmissivity leads to the low life safety and the obstruction which can be happen unexpectedly on the evacuation way on fire makes it worse. At the condition of the smoke density 0%, over 90% people arrive at upper deck exit safely. But with the transmissivity of 8%, 70%(from ECR) and 30%(from bosun store) among experiment persons of each can survive, and with same density and unexpected obstruction, the survival ratio goes down to only 20% and 10%.

An Experimental Study on PWR Nuclear Fuel Assembly Vibration (경수로 핵연료집합체 진동의 실험적 고찰)

  • 장영기;김규태;조규종
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.82-87
    • /
    • 2003
  • Nuclear fuel with a big slenderness ratio is susceptible to flow-induced vibration under very severe conditions of high temperature, high flow and exposure to irradiation in nuclear reactor. The fuel assembly should, therefore, be designed to escape any resonance due to the vibration during the reactor operation, in particular, in case of the design changes. In addition, the amplitudes due to the grid vibration, the fuel rod vibration and the fuel assembly vibration should be minimized to reduce the grid-to-rod fretting wear. Fuel assembly vibration tests in air at room temperature and in water at high temperature have been performed to investigate fuel vibration behaviors. The frequency and damping during the test in air have been compared to those in water. Through the hydraulic test, the advanced assembly has been evaluated not to be susceptible to any resonance. In addition, the test data from the tests can be used to make fuel model and to evaluate grid-to-rod fretting wear.

  • PDF

Development of Potential Function Based Path Planning Algorithm for Mobile Robot

  • Lee, Sang-Il;Kim, Myun-Hee;Oh, Kwang-Seuk;Lee, Sang-Ryong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2325-2330
    • /
    • 2005
  • A potential field method for solving the problem of path planning based on global and local information for a mobile robot moving among a set of stationary obstacles is described. The concept of various method used path planning is used design a planning strategy. A real human living area is constructed by many moving and imminence obstacles. Home service mobile robot must avoid many obstacles instantly. A path that safe and attraction towards the goal is chosen. The potential function depends on distance from the goal and heuristic function relies on surrounding environments. Three additional combined methods are proposed to apply to human living area, calibration robots position by measured surrounding environment and adapted home service robots. In this work, we proposed the application of various path planning theory to real area, human living. First, we consider potential field method. Potential field method is attractive method, but that method has great problem called local minimum. So we proposed intermediate point in real area. Intermediate point was set in doorframe and between walls there is connect other room or other area. Intermediate point is very efficiency in computing path. That point is able to smaller area, area divided by intermediate point line. The important idea is intermediate point is permanent point until destruction house or apartment house. Second step is move robot with sensing on front of mobile robot. With sensing, mobile robot recognize obstacle and judge moving obstacle. If mobile robot is reach the intermediate point, robot sensing the surround of point. Mobile robot has data about intermediate point, so mobile robot is able to calibration robots position and direction. Third, we gave uncertainty to robot and obstacles. Because, mobile robot was motion and sensing ability is not enough to control. Robot and obstacle have uncertainty. So, mobile robot planed safe path planning to collision free. Finally, escape local minimum, that has possibility occur robot do not work. Local minimum problem solved by virtual obstacle method. Next is some supposition in real living area.

  • PDF

Experimental Study on Features of Air Egress Velocity in Vestibule Pressurization System (특별피난계단 부속실 제연설비의 방연풍속 기류특성에 관한 실험적 연구)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Yoon, Myong-O;Choi, Keum-Ran;Park, Jae-Hyun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.79-86
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system which is installed in vestibule of smokeproof stairway in domestic high-rise building becomes back-flow into the vestibule not into the livingroom when the doors open to escape in case of fire by actual measurement. It concerned that fire smoke inflow into the vestibule of smokeproof stairway. so, reflux symptoms were developing the condition does not occur by creating an area of $2m^2$ and a model. if it‘s area is less, airflow in upper area was severely reflux. in the case upward 45 gradient of supply damper’s angle of blade, The results that reflux symptoms include upper door but bottom has some reflux. also vestibule of smokeproof stairway‘s area of $4m^2$ in the living room door in the direction of the flow distributon was normal. if a vestibule of smokeproof stairway is smaller, it designed to be performance-based design should be.

Characteristics of Air Egress Velocity in Vestibule Pressurization System Using the Fire Dynamics Simulator (FDS를 이용한 특별피난계단 부속실 제연설비의 방연풍속 기류특성)

  • Ryu, Sung-Ho;Lee, Su-Kyung;Hong, Dae-Hwa;Choi, Keum-Ran
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.153-159
    • /
    • 2010
  • In this study, we confirmed the fact that air egress velocity of pressure differential system installed at vestibule of smokeproof stairway in domestic high-rise building becomes back-flow to stair-lobby at upper vestibule. Rather it do not back-flow to the livingroom. when fire occur and the door opens to escape from fire zone. so we carry out actual and computational fluid dynamics measurement. In the case upward 45 gradient of supply damper's blade, The simulation results that air flow of upper vestible is steady but back-flow phenomenon occurred at the bottom. However, in the case of $4m^2$, direction of the flow was ideal to living room. If a vestibule’s area is smaller, it must be designed and built according to performance-based design.

A Study on Design Improvement for Smoke-Control System Using the Pressurization of the Elevator Shaft (승강로 가압 제연설비의 설계개선에 관한 연구)

  • Kim, Il-Young;Kim, Kyung-Jin;Hong, Ji-Hwan;Kwon, Chang-Hee;Yoo, Chul-Kwon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.74-83
    • /
    • 2019
  • In the U.S., the pressurization of elevator shaft was developed in 1972 to allow vulnerable people, such as the elderly and weak who could not use escape stairs in case of fire, to evacuate. It is an advantage in terms of space saving by not using vertical ducts. This study drew the problem of the pressurization of elevator shaft based on the existing domestic patents and proposed improvements. The smoke control volume calculation method is proposed by using vertical modeling. Leakage gaps in elevator doors need to be reviewed through experimental data or actual data. The evacuation floor was divided, the openings in the elevator machine room were automatically closed to the fire signal and the relief damper was installed to improve the performance. The improved method functions as the smoke control damper supplying the air flow rather than maintaining the differential pressure. To increase reliability of the research results, the procedure was performed to verify by using Contam.

A Study for Pressure Difference and Critical Velocity by Pressurization of Elevator Shaft at High Rise Apartment (고층 공동주택의 승강로가압을 이용한 차압 및 방연풍속에 관한 연구)

  • Park, Kyung-Hwan;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.89-93
    • /
    • 2011
  • It is not recommended that elevator use for egress at (super) high rise buildings because elevator shaft main roles to spread of fire smoke. But in North America used to protect this area by elevator shaft pressurization. These tests are performed at high rise apartment to verify that elevator shaft pressurization can protect to spread of fire smoke or not. and verify to used for egress at fire. Pressurization at elevator shaft make pressure difference of 50 Pa all floor at 150 CMM because this method have low friction loss from air flow. Also when dwelling door and elevator door are opened that critical velocity is performed to protect of back-layering from fire room for escape routs by 180 CMM. Therefore through out these pressurization tests by elevator shaft are estimated to have less overpressure because supply air difference are low between to satisfy critical velocity at one door opened and maintain to pressure difference all doors closed. Finally we verified that disable or residual people can use elevator for egress at fire by elevator shaft pressurization.

Developing a first-person horror game using Unreal Engine and an action camera perspective (언리얼엔진과 액션 카메라 시점을 활용한 1인칭 공포 게임 개발)

  • Nam-Young Kim;Young-Min Joo;Won-Whoi Huh
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.1
    • /
    • pp.75-81
    • /
    • 2024
  • This paper focuses on developing a first-person 3D game to provide extreme fear to players through realistic camera direction utilizing the features of action cameras. As a new camera production technique, we introduce perspective distortion using a wide-angle lens and camera shake when moving to provide higher immersion than existing games. The theme of the game is horror room escape, and the player starts with a firearm, but in order to overcome the concern that the game's difficulty is low due to the use of firearms, the player is asked to control the use of firearms by imposing burdens such as chasing monsters and reducing the number of magazines. The significance of this paper is that we developed a new type of 3D game that maximizes the fear effect of players through realistic production.

Psychological Stability Color for The Fire Escape Mobile App (심리적 안정감을 주는 화재 피난 모바일 앱(App) 컬러연구)

  • Lee, Sang ki;Park, Hae Rim
    • Journal of Service Research and Studies
    • /
    • v.12 no.2
    • /
    • pp.106-116
    • /
    • 2022
  • As part of the Fire Evacuation Service scenario using mobile applications, this study aims to find the appropriate colors to be used in the interface of the application and to define and apply colors that can positively and reliably affect human unstable psychology in the course of evacuating the room in case of fire. In the situation of fire, proper design and placement of the colored escape guidance interface is important, taking into account the psychology of the occupants. However, literature and previous research have shown that colors used to induce evacuation are not suitable for effective evacuation in case of fire. In this study, the purpose of the study was to provide a color that would provide psychological stability in the event of a evacuation in consideration of the psychological issues of those who are still in need of shelter, and to use it to help induce an efficient evacuation in the event of a disaster. Using the image evaluation method, the form and color of images have been derived through frequency analysis to a number of unspecified people, and the main and secondary colors of images were analyzed through KSCA color analysis. Finally, the final application color was constructed through mutual verification between the results by comparing and analyzing the colors obtained through the image evaluation analysis results and the KSCA color analysis results. The results of the study showed that the green line can help stabilize the human mind through comparative analysis with prior research. Therefore, the main color for guiding calm and calm applications in case of fire escape is proposed in the green line. In this study, the experiment with image evaluation cannot accurately measure the effect of factors on color among complex factors. A subsequent study of this will help quantify images if it allows the subject matter of color and image to be defined to some extent through factor analysis.

Safety Evaluation of Evacuation in a Dormitory Girls' High School based on PAPS (PAPS에 기반한 여자고등학교 기숙사생의 피난 안전성 평가)

  • Jeon, Seung-duk;Kong, Ha-sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.1
    • /
    • pp.469-481
    • /
    • 2022
  • This study is for increasing evacuation safety by analyzing RSET(the required safe escape time) through the arrangement of personnel by floor and by room while evacuating in a Girls' High School Dormitory. For this study, PAPS(Physical Activity Promotion System) results that have not been studied so far were analyzed and reflected in evacuation simulations on the premise that individual student's physical strength can affect evacuation. Based on the PAPS results, four scenarios were applied. In addition, evacuation simulation using the pathfinder program was conducted in two situations: the evacuation route was assigned or not. Scenario 4 was the fastest at 168.5 seconds of RSET in assigning evacuation routes among scenarios. As a result of this study, the arrangement of students focusing on improving their academic ability and student life guidance excluding student physical strength has problem. In order to solve this problem, it is effective to place C group students(low grade on PAPS) on low floors and A group students(high grade on PAPS) on high floors and to assign evacuation routes in each room. In the future, the following ways need to be more studied. A study on how to increase evacuation safety through practical evacuation training, the way of assessing evacuation safety reflecting the lifestyle and physical strength of girls, the evacuation route assignment according to the fire occurrence point, and the method to secure evacuation routes in the event of a fire near stairs or entrances should be conducted.